Essick 427 300 Care & Use Manual

Category
Dehumidifiers
Type
Care & Use Manual

Essick 427 300 is an evaporative humidifier that adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Thanks to that, there is no messy mist or spray, just clean and invisible moist air. It has two speed or variable fan speed allowing you to use the low setting for the quietest operation or a high setting for maximum output.

Essick 427 300 is an evaporative humidifier that adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Thanks to that, there is no messy mist or spray, just clean and invisible moist air. It has two speed or variable fan speed allowing you to use the low setting for the quietest operation or a high setting for maximum output.

OWNER’S
CARE
&
USE
MANUAL
EVAPORATIVE
HUMIDIFIER
READ AND SAVE THESE INSTRUCTIONS
MODELS:
427 300 OAK BURL 2 SPD
696 400 LT OAK VARIABLE SPD
697 500 CHERRY VARIABLE SPD
• Automatic Humidistat
• Automatic Shutoff
• Quiet Setting for Nighttime use
• Easy to clean, removable power pack
SAVE THE ENVIRONMENT
RECYCLE APPROPRIATE MATERIALS
Patents: 5,037,583; 5,110,511; 5,133,904
Other Patents Pending
To order parts and accessories call
1-800-547-3888
696 400
697 500 427 300
French and Spanish
Instructions included.
Se incluyen instrucciones
En Español y Francés.
Directives en Français et en
espagnol compris
IMPORTANT SAFEGUARDS
READ BEFORE USING YOUR HUMIDIFIER
1. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric
shock, this plug is intended to fit into a polarized 120-volt AC, 15 amp outlet, and only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
Do not attempt to defeat this safety feature. If an extension cord must be used, it should also accept
the wide blade plug and meet this electrical rating.
2. Do not place the cord under rugs, near loose draperies, in traffic areas, nor near heat sources or
combustible materials.
3. Do not use the humidifier if the cord is damaged.
4. Always unplug the power cord before filling, cleaning, servicing, or when the unit is not in use.
5. This humidifier is UL/CUL listed with Essick Air brand evaporative wicks in place.
6. It is very important that cleaning solutions such as bleach, anti-bacteria treatment or descaler, which
could be used to clean the cabinet, are not sprayed or applied to the chassis assembly. These
solutions can cause serious electrical malfunction of the humidifier.
INTRODUCTION
Your Essick Air evaporative humidifier adds invisible moisture to your home by moving dry inlet air through
a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any
white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is no
messy mist or spray, just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate
water decreases. We recommend changing the wick at the beginning of every season. In hard water
areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.
Use only Essick Air brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-
800-547-3888. The 400 and 600 Series humidifiers use Essick Air wick # 1041 and accommodate air filter
#1051. Only the Essick Air evaporative wick guarantees the certified output of your humidifier. Use of wicks
other than Essick Air brand will void your warranty as well as the certification of output and may reduce the
efficiency of your humidifier.
CAUTION: Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on
soft carpet.
HOW YOUR HUMIDIFIER WORKS
Dry air is drawn into the
humidifier though the
back and moisturized
as it passes through the
evaporative wick. It is
then fanned out into the
room.
LEGEND:
1. Water bottle
2. Chassis/power pack
(motor/fan assembly)
3. Evaporative wick
4. Water reservoir
5. Dry room air intake
6. Moist air output
ASSEMBLY
UNPACKING AND SETTING UP THE UNIT
1. Remove the two inserts from the top of the humidifier.
2. Lift off the water bottle covers. Remove the water bottles, lift off the chassis/power pack and then
remove the humidifier cabinet from the carton.
3. Remove the evaporative wick and all of the remaining packaging materials from the cabinet. Check to
see that you have all of the following items removed from the boxes, accessory kit, and cabinet before
discarding the packaging:
Filler Hose Evaporative Wick
Caster kit Two end covers
Bacterial treatment sample
Two Water Bottles
Optional Air Care ® filter (included on 697 and
427 models; sold separately on 696 model
CASTERS
4. Turn the emptied cabinet upside down. Insert each caster stem into a caster hole on each corner of the
humidifier bottom. The casters should fit snugly and be inserted until the stem shoulder reaches the
cabinet surface.
5. Turn the cabinet right side up.
EVAPORATIVE WICK
6. Insert the 1041 wick into the unit. The wick has a mounting
rib on the top edge which hooks over a rib at the inside back
of the cabinet. This allows the wick to hang in the water
channel (see cutaway illustration for details). Hang wick into
cabinet as shown.
OPTIONAL AIR CLEANING FILTER
(included on 427 and 697 models; sold separately on 696)
7. If available, install the 1051 AirCare® filter at the back of the
unit. The filter has tangs that engage into four keyhole
slots that mount the AirCare® filter onto the outside of the back of the cabinet.
FILLING INFORMATION
8. Your humidifier is equipped with two water bottles. On the 696 and 697 models each bottle holds 2.6
gallons. The 427 model bottles hold 2.75 gallons each.
9. A fill hose that fits most faucets is provided with your humidifier. Fill the bottles with cool, fresh
(preferably unsoftened) water. If you only have softened water available in your home, you can use it,
but mineral buildup will occur more quickly.
NOTE: For optimum running time, fill each water bottle, tighten the cap, and place inside unit. Do not fill the
reservoir bucket, as overfilling will result in water damage. Use only the bottles provided. One bottle will
drain until the reservoir is filled. Remove the partially emptied bottle and refill it. Place back in humidifier
cabinet.
CAUTION: When filling, be careful not to pressurize the bottle by overfilling it. Bottle damage can result
from this, and will not drain properly.
NOTE: On initial fill up, it will take approximately 20 minutes for the reservoir to fill because the dry wick has
to absorb water. Subsequent fillings will take approximately 12 minutes, since the wick is already saturated.
10. After the filling process is complete, insert the water bottles into the humidifier, placing them with the
valve cap end down, so that the groove in the water bottle faces the inside.
11. After filling, replace the water bottle cover and place the chassis/power pack unit into the cabinet, so it
fits without tipping or rocking.
1041 WICK
1041 WICK
CONTROLS AND OPERATION
1. Plug cord into wall receptacle. Your humidifier is now ready for
use. The humidifier should not be near any heat registers. Place
the unit at least FOUR inches away from any walls. Unrestricted
airflow into the unit will result in the best efficiency and
performance.
2. Access the control panel by opening the panel door (427 Model).
Depending on which model, you may have a choice of 2 speed or
variable fan speed allowing you to use the low setting for the
quietest operation or a high setting for maximum output.
NOTE: When excessive condensation exists, a lower speed setting
is recommended.
NOTE: Each model has an automatic humidistat. The humidistat will
turn the humidifier on when the relative humidity in your home is
below the humid- stat setting and will turn the humidifier off when the
relative humidity reaches the humidistat setting.
3. For initial operation, set the humidistat at its midpoint “comfort
zone” setting and adjust up or down from there to achieve the
desired humidity level. Turning the Humidity Control knob all the
way counterclockwise will turn the unit off regardless of the
relative humidity. This must be turned on again before the unit will work.
4. One bottle is designed to empty first. The refill light will indicate when the respective bottle is out of
water. When the unit is completely out of water, the motor will shut off.
OPTIONAL AIRCARE® FILTER
The optional Aircare® filter is a excellent means of cleaning the air while using your humidifier. The first
stage of the air filter is a high-efficiency, electrostatically charged filter media which traps dust, pollen, and
airborne pollutants. The second stage is an activated carbon media which absorbs odors from cooking, pets,
or tobacco smoke.
We recommend replacing the AirCare® filter at least once a year and more often if necessary. When the white
filter media is coated with a layer of dust and dirt, it is time to replace the AirCare® filter. The certified water
output of your humidifier will be reduced when using the AirCare® filter. AirCare® filters are optional and are
not required for normal operation of the humidifier. AirCare® is registered trademark of Essick Air Products.
CARE AND MAINTENANCE
Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household
bleach is a good disinfectant and can be used to wipe out the humidifier base and bottle/reservoir after
cleaning. We recommend cleaning your humidifier at least once every two weeks to maintain optimum
environmental conditions for your home.
We also recommend using Essick Air Bacteriostat Treatment each time you refill your humidifier to eliminate
bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800-547-3888 to
order Bacteriostat Treatment reference part number 1970.
1. Turn off unit completely counterclockwise and unplug from outlet.
2. Lift out the water bottle and the power pack.
3. Carry bottle and base to cleaning basin. Lift wick from the base allowing the water to drain. Rinse wick
under fresh water only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to
drain.
REMOVING SCALE
4. Empty the water from the reservoir and water bottle. Fill reservoir and each water bottle ½ full with water
and add 8 oz. (1 cup) of white vinegar to each. Let stand 20 minutes. Then empty solution.
5. Dampen a soft cloth with white vinegar and wipe out reservoir to remove scale. Rinse the water bottle and
reservoir thoroughly with fresh water to remove scale and cleaning solution before disinfecting.
DISINFECTING UNIT
6. Fill each water bottle and reservoir ½ full with water and add 1 teaspoon of bleach to each. Wipe cabinet
and bottle surfaces with this solution. Let solution stay for 20 minutes, then rinse with water until bleach
smell is gone. Dry with clean cloth. The outside of the unit and water bottle may be wiped down with a
soft cloth dampened with fresh water.
7. Refill unit and re-assemble per ASSEMBLY instructions.
SUMMER STORAGE
1. Clean unit as outlined in Care & Maintenance section.
2. Discard used wick and any water in the reservoir or bottle and allow to dry thoroughly before storage. Do
not store with water inside reservoir or bottle.
3. Do not store unit in an attic or other high-temperature area.
4. Install new filter at beginning of season.
ESSICK AIR PRODUCTS
HUMIDIFIER WARRANTY POLICY
EFFECTIVE APRIL 1, 2008
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE
FOR ALL WARRANTY CLAIMS.
This product is warranted against defects in workmanship and materials for one year
from the date of sale except for motors, which are warranted for two years. This
warranty does not apply to filters or wicks which are customer-replaceable parts.
This warranty applies only to the original purchaser of the product when it is purchased
from a reputable retailer/dealer.
This warranty does not apply to damage from accident, misuse, alterations,
unauthorized repairs, unauthorized use, mishandling, unreasonable use, abuse,
including failure to perform reasonable maintenance, normal wear and tear, nor where
the connected voltage is more than 5% above the nameplate voltage, nor to the
equipment or products being improperly installed or wired or maintained in violation of
this Owner’s Manual.
Alterations include the substitution of name brand components including, but not limited
to wicks and bacteria treatment.
THIS PRODUCT IS NOT INTENDED FOR COMMERCIAL USE. THIS IS THE SOLE
AND EXCLUSIVE WARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO
THE PRODUCTS AND, TO THE MAXIMUM EXTENT PERMITTED BY LAW, IS IN
LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS,
EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW OR OTHERWISE,
INCLUDING WITHOUT LIMITATION, MERCHANTABILITY AND/OR FITNESS FOR A
PARTICULAR PURPOSE.
No employee, agent, dealer or other person is authorized to give any warranties or
conditions on behalf of the manufacturer. The customer shall be responsible for all
costs incurred in the removal or reinstallation and shipping of the product for repairs.
Within the limitations of this warranty, purchaser with inoperative units should
contact customer service @ 800-547-3888 for paperwork and instructions on the
return of the unit for repair. A copy of the sales receipt is required before
authorization to return a unit for repair is approved. The manufacturer will repair or
replace the product, at its discretion, at no charge to the customer with return freight
paid by the manufacturer. It is agreed that such repair or replacement is the exclusive
remedy available from the manufacturer and that TO THE MAXIMUM EXTENT
PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR
DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL
DAMAGE OR LOSS OF PROFITS OR REVENUES.
This warranty will be null & void if purchaser attempts to repair or replace any
parts which are mechanical or electrical.
The warranty gives the customer specific legal rights, and the customer may also have
other rights which vary from province to province, or state to state.
MANUAL
DE
CUIDADOS
Y
USO DEL
PROPIETARIO
LEA Y GUARDE ESTAS INSTRUCCIONES
HUMIDIFICADOR
VAPORIZADOR
427 300, NUDO DE ROBLE – 2 velocidades
696 400, ROBLE – Velocidad variable
697 500, CEREJEIRA – Velocidad variable
Humidistato Automático
Apagado automático
Funcionamiento silencioso para uso nocturno
Fácil de limpiar, unidad de fuerza removible
CUIDE EL MEDIOAMBIENTE
RECICLE LOS MATERIALES APROPIADOS
Patentes: 5,037,583; 5,110,511; 5,133,904
Otras patentes pendientes
Para encomendar piezas y accesorios,
llame al 1-800-547-3888
French and Spanish
Instructions included.
Se incluyen instrucciones
en español y francés.
Directives en Français et en
espagnol compris
696 400 427 300
697 500
1B71817 4/08
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Essick 427 300 Care & Use Manual

Category
Dehumidifiers
Type
Care & Use Manual

Essick 427 300 is an evaporative humidifier that adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Thanks to that, there is no messy mist or spray, just clean and invisible moist air. It has two speed or variable fan speed allowing you to use the low setting for the quietest operation or a high setting for maximum output.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages