Whirlpool 1172397 User manual

Category
Split-system air conditioners
Type
User manual
Part No. 1172397
Pieza N” 1172397
Pike no
1172397
Table of Contents
Introduction
Page 2
Requirements
Page 3
Preparation
Page
4
Installation
Pages
4
and
5
Important:
. Installer: Leave Installation
Instructions with the homeowner.
l
Homeowner: Keep Installation
Instructions for future reference.
l
Save Installation Instructions for local
electrical inspector’s use.
lndice
Introducch
Pigina 2
Requerimientos
Pigina 3
Preparacih
P@ina
4
Etapas de la lnstalacih
P;iginas
4 y 5
Importante:
l
Instalador: Dewelva 1%
instrucciones de instdlaci6n al
propietario.
l
Propietario: Consen~e estas
instrucciones de instdlacidn para
referencia futurd.
l
Conserve las instrucciones de
instaldcicin para uso del inspector
ektrico
local.
Table des matibres
Introduction
Page 2
Exigences
Page 3
Preparation
Page
4
Installation
Pages
4
et
5
Important :
. Installateur : Remettre les
instructions d’installation au
propri&tire.
l
PropriCtaire : Conserver les
instructions d’installation pour
r6fkrence ulttrirure.
l
Conserver les instructions
d’instdllation pour utilisation par
I‘inspecteur local des installations
dlectriques.
1
1
L
I
Window opening measurements
Medidas de la abertura de la ventana
Dimensions de I’ouverture dans la fen&e
Excessive Weight Hazard
Use two or more people to move
and install air conditioner.
Failure to do so can result in
back or other injury.
Important: Observe all governing codes
and ordinances.
Check location where air conditioner will be
installed. Proper installation is your
responsibility. Make sure
you
have everything
necessary for correct installation.
l’he location should provide:
l
Grounded electrical outlet within 4 feet
(122 cm) of the left bottom corner of the
window. Do not use an extension cord.
l
Free movement of air to rooms to be
cooled.
l
A large
enough
opening for
the
air
conditioner. Installation parts are
supplied for double-hung windows up to
38 inches
(96.5
cm)
wide. A special. Wide
Window Kit is available from your dealer
or service center for windows 38”
(96.5
cm) to 54” (137.2 cm) wide. Use Kit SOS.
115585 1 and 485676. (Curtains must be
removed *and replaced with tiller boards.)
. Adequate wall support for weight of ‘air
conditioner. Air conditioner weighs
behveen 80 and 100 pounds (36.3
to
45.4
kg).
Peligro de Peso Excesivo
Se necesitan dos personas o m8s
Importante: Obserave todos 10s c6digos y
reglamentos aplicables.
Verifique el lugar donde se instalarj el
acondicionador de airc. La insvdlacicin correcta
es su responsahilidad. Ascgilrcse de que usted
tiene todo lo necesai-io
pard iina
instalaci6n
correcta.
El kigar debe proporcionar:
l
Tomacorriente puesto a tierra a cuatro
pies (122 cm) de la esquina inferior
izquierda de la ventana. Yo use cable de
extensi6n.
l
Libertad de movimiento del aire a las
hahitaciones que desea enfriar.
l
IYna abertura con la amplitud sulkiente
para el acondicionador de aire. Se
incluyen piezls de instdlaci6n
para ventanas
de guillotina de
Iiasta .1X pulgadas
(96,5 cm)
de ancho. IIn Juego para Ventana Ancha
especial esd disponihle de su distrihuidor o
cenlro de scrvicio para ventanas de 38” (96,s
cm) a
54” (I 37,2
cm)
de ancho. llse Juegos
No. 115585 1 y 4X5676. (Dehc @tar IZLS
cortiiias y reemplazarhs por tdblas de
relleno).
l
Soporte adecuado en la pared para el
peso del acondicionador de aire. El
acondicionador de aire pesa entre X0 y 100
lihras (de 36,s a 45.4 kg).
Risque du poids excessif
Utiliser deux ou plus de
personnes pour dkplacer et
installer le climatiseur.
Le non-respect de cette
instruction peut causer une
blessure au dos ou d’autres
blessures.
Important: Respecter les prescriptions de
tous les codes et rtiglements eo rigueur.
Inspecter I’emplacemeiit
oii
le climatiseur sera
install& c’est au propri6talre qu‘iiicomhe la
responsahihtd
d’une
installation correcte.
Verifier que tout Ic matCricl ii6cessaire pour
uw
installation corrccte est dlsponihle.
L‘emplacement d’installalion
devrdit fournir:
l
Prise de courant klectrique reliCe B la
terre sit&e B moins de 122 cm (4 pi) de
l’emplacement d‘installation (feni%!). lie
pzi utiliscr une
i-dllonge pour
I‘alimentation
Clectriqiie de I’appareil.
l
Circulation libre de I’air jusqu’aus pi&s
g refroidir.
l
Ouverture de taille suffrsante pour
l’installation du climatiseur. Les pi&s
d‘installation sont fournies pour line fen@tre g
guillotine
de largeur maximale de
96,5
cm
(38 po). Pour line EenCtre de
grande
largeur.
de 96,i cm ($3 1101 B 137.2
cm
(54 po), commander I’ensemble sp6cial
pour grande fen& auprtis du
concessionnairc
011 du service d‘entrctien.
Uiliser les necessaires
no 11 j 585 1 et
485676. (Les rideaus doivent Etre enlevh et
remplac6s par dcs
~planches
dc rcmplissage.)
l
Support mural adkquat pour le poids du
climatiseur. Le poids du climatiseur est de
363 i 45.4 kg (80 1 100 lirres),
Do not install the air conditioner in an
area where the front panel will be exposed to
heat sources that will raise the panel surface
temperature above 120°F (50°C).
Remove storm window or any item that would
not allow proper installation
No instale el acondicionador de aire en
nn
lrea donde el panel delantero est6 expuesto a
fuentes de
calor
que aumenten
la
temperatura
de la superficie del panel a
on
nivel superior a
10s 120°F (50°C).
Quite el
guar&dveiitana o cu;dqiiier otro
objet0
que pueda impedir la dehida instalaci6n de1
aFdKtt0.
Ne pas installer le climatiseur :d
II~
emplacement oil le
panneau avant
strait expos6
?I des sources de chaleur susceptiblcs de porter
la temp@rature superfrcielle du panneau avant 1
plus
de 50°C (120” F).
Enlever la fen@tre coupe-vent et tout article qui
emp6cherait unc installation correcte.
A. electric drill
D. level A. taladro elktrico D. nivel
A. perceuse D. niveau
and 3/32” or
smaller bit
B. utility knife
C. flat-blade
screwdriver
E. tape measure
F. gloves
G. safety glasses
y una broca
de 3/32” o mb
E. cinta para medir
pequeiia
F. guantes
B. cuchillo de uso
G. Anteojos
general
protectores
C. desarmador de
hoja plana
electrique et foret E.
m&e-ruban
de 3/32 po ou
plus petit
F. gants
B. couteau utilitaire
G. lunettes de
sCcurit6
C. tournevis 2 lame
plate
Saque 1:~s piezas de 10s paquetes. Verifique que
parts were included.
est6n incluidas todas 1,~ piezas.
prCsence de toutes Irs pieces
A. window-lock D. 3, #8 x 314” hex-
A. soporte de C. obturador del riel
A. bride de blocage C. joint pour tringle
head. metal
seguridad para la de la ventana
de la fen&e
d’appui de la
B. gum-type sealer
screws
ventana
D. 3 tornillos B. mastic
fen@tre
C. window rail seal
B. sellador tipo hexagonales para
d’Ctanch&tC
D. 3 vis g mktaux
goma
metales, #8 x 3/4”
no 8 x 3/4 poA&te
hex.
2
Electrical Shock Hazard
Plug into a grounded 3 prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these
instructions can result in
death, fire, or electrical shock.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
Check with a qualified electrician if you are not
sure the air conditioner is properly grounded.
A three-wire, single-phase, 60-Hz, AC-only,
electrical supply is required
011 a separate
circuit.
A
I5-amp
time-delay
fuse
or circuit
breaker is required. Copper wire (#I4
gauge) is required. The fuse size must not
exceed the
circuit rating specified on the
model and serial label.
The model and serial ]abcl (A) is
kdted
behind the front panel above the coil area.
This label lists Lhe HTLT capacity, amperage,
voltage and refrigerant charge requirements.
Recommended grounding
m -
method
m
B
----a
aI
0
II
0
For your personal safe@ this air conditioner
must be grounded. This air conditioner is
equipped with
a power supply
cord (8) with a
.I-prong ground plug (C). ‘To minimize
possible electrical shock hazard, the cord must
be plugged into a mating, 3-prong grounding-
type wall receptacle (D), grounded in
accordance with all local codes ;uld
ordinances. If a mating ?-prong grounding-
type
wall
receptacle is not available, it is the
consumer’s responsibility to have a properly
grounded. .i-prong wall receptxle installed by
a licensed installer.
It is the customer’s responsibility:
l
To contact a quahEed electrical installer.
l
To assure that the electric~al installation is
adequate and in confornwce with liational
Electrical Code, ANSL/NFPA 70 - latest
edition.* and all local codes and ordinances.
Copies of the standards listed may he obtained
from:
* National Fire Protection Association
Batterymarch Park
Quincy. Massachusetts
02269
Specific electrical requirements are listed
below. Follow the requirements for the rating
on the model and serial rating label.
. 1 I5 volt - 103.5~ min., 126.5~ max
l
7.5.amp ratmg or less - a double outlet is
acceptable.
l
7.6 - through 12.amp ratings - use only a
single outlet *and a separate circuil.
l
l+uge copper wiring
Peligro de Choque Ekictrico
Conecte a un contacto de pared
de conexi6n a tierra de 3
terminales.
No quite el terminal de conexi6n
a tierra.
No use un adaptador.
No use un cable elCctrico de
extensi6n.
No seguir estas instrucciones
puede ocasionar la muerte,
incendio o choque el&trico.
S610
en
10s EEJI’.:
Si 10s c6digos lo
permiten y se utiliza un alambre de
puesta a tierra separado, se recomienda
que un electricista calitkado determine si
la trqectoria de la puesta a tierra es
adecuada.
Consuhe con tin electricista calificado
pard
asegurdrse de que el acondicionador de aire
csta debidamenle pueslo a tierra.
Se requiere un suministro ektrico monofhico
de tres alambres,
de 60 Ilz, scilo de CA, en tm
circuit0 separado.
Se requiere un fusible de retard0 o nn disyntor
de I j amperes. llse sohmentc alambre de
cobre (calibre #la). t;l tamaiio de1 fusible
no
debe
exceder II clasificaci6n del circuito
especificada en
la
eliqueta de model0
y serie.
kd
etiqueta de modelo y serie (A) se encuentra
dctris del panel delantero, sobre el irea del
serpentin. Esta etiqueta indica la capacidad
BTU, el amperaje, el volbje )’ Ios requerimientos
de carga refrigerante.
Metodo recomendado para
la puesta a tierra
Para
su
seguridad personal, este
acondicionador de aire debe ser puesto a tierra.
Este acondicionador de aire esG equipado con
un cord6n electrlco
(B)
provislo de un enchufe
con clavija tripolar (C) de conexi6n a ticrra.
Para reducir a
un
minim0 el riesgo posible de
un choyie cl&-ice. el cord6n debe enchufarse
en un tomacorriente mural pai-a clavija con
3 terminates (D), puesto a Lierra de acuerdo
con todos 10s ccidigos y reglamentos locales. Si
no se disponc de un lomacorricntc para clavija
tripolar. es rcsponsabihdad de1 cliente hater
instalar un tomacorricnte para clavija con tres
Lerminales debidamence puesto a tierra por
un
electi-icisla con hcencia.
Es responsabilidad de1 clienle:
l
Llamar a un instalador eklrico cahficado
l
Asefiurarse de que la instalacicin el&crica es
adecuada y de acuerdo con el C6digo Kacional
de Energi?. .4W&FPA 70, tiltima edicSn*. y
todos 10s ccidigos y reglamentos locales
Puedcn obtrnersc copias de las normas seiialadas
del:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts
02269
Los requerimicnlos elCclricos especificos se
indic,an ahajo. Siga 10s requerimienlos de 1a
clasificacicin en
la
e@ueta de modelo y
clasificaci6n de serie.
l
115 voltios (IO?,5 min. 126.5 m&x,)
l
cktiificaci6n de 7,5 amperes o menos - es
aceptable un lomacorrlente doble.
l
clasificaciones de 7,6 a 12 amperes - use
tinicamenle un solo tomacorriente y tin
circuit0
separddo.
l
cableado de cobre de calibre 14
Risque de choc dlectrique
Brancher I’appareil uniquement
sur une prise 2 3 alv6oles reli6e B
la terre.
Ne pas enlever la broche de
liaison 5 la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un c5ble de
rallonge.
Le non-respect de ces
instructions peut causer un
d&&s, un incendie ou un
choc 6lectriaue.
Si un conducteur distinct
de
liaison k la
terre est utilisk lorsque les codes le
permettent, on recommande qu’un
Clectricien qualifik krifie la qualit de la
liaison g la terre.
En cas de doute quant B
la
qualit de la liaison g
la terre de cet apparcil, conkxter un &ctricien
qualifiC.
L’appareil doit 6tre aliment6 par un circuit
indkpendanc a trois Ells (monophase, 60
117, CA
seulenient). Le circuit doit i?ti-e protCg6 par un
disjoncleur
ou 1111
fusible tempo& de 15
amp&es.
Ih
fit de cnivre (cahbre 14 est requis).
L‘amp&ge du fusible
ne
doit pas esceder Ic
maximum prescril sur la plaque signalfitiquc.
On trouvc le num6ro de modtile et le num6ro de
serie sur la plaque signal&clue
(A)
derriere le
panneau avant au-dessus des serpentins. La
plaque signal&ique indique 1a capacitc thermique
(BTLI), les cara&ristiques Clectriques et la
charge de r6frig6rant B utiliser.
Mbthode recommandke
de liaison ti la terre
Pour
Ia
s&twit6 personnellc dcs uMisateurs, il
faut que ce climatiscur soit reliil i la terre. Ce
climatiseur est ,alimcnL@ par
uii cordon
6lectrique
(B)
comportant nne fiche de
branchcmcnt (C) a trois broches, pour liaison
I
la
terre. Pour mmimiser le risque de choc
Clectriquc, bran&r le cordon d‘ahmcntation
sur
unc prise de courant murak
(D)
compatible
I
trois ah6oles. reliee 1 la terre
conformCment aus prescriptions de tous les
codes et rcglemcnts
locaus en vigucur. Si unc
prise de conrant compatible avec la fiche de
brdnchement n‘est pas disponible, c’est au
client qu’incombe I’obligation de faire inslaller
une prise de courant murale j 3 alvColes
convenablement reh&e a
kd
terre, par un
eleclricien qualifiC.
C’est au client qu’incombe la responsabiM de:
l
Contacler
un
eleclricien qualifiC
l
Veiller g ce que I’jn>tallacion ClecWique soit
r6alis6e adCquatement et
cn
conformit@ avec
les prescriptions du Code national des
installations &triques, ANSl/VFP,2 70
(derni6re edition*), et de tous les codes et
r?glemcnts
locaiis en vigueur.
On peat obtenir un exemplaire des normes
mention&es B I’adresse suivante:
*National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts
02.269
Le Lableau ci-dessous indique les
cara&rishques Gctriques spdcifiques 1
respecler. Respecter les eUgcnces indiqu6es
wr
la
plaque signal&ique.
l
1
I5 voks 103,Sr
min.,
126,5v max.
l
7.5 amp
OII
moins une double prise cst
acceptable.
l
7.6 i I2 amphres inclusivement n’utiliser
qu‘une prise simple et tin circuit dislincl.
l
tiblage de calibre 14 (cuivre)
3
Handle air conditioner with care.
Watch out for sharp metal fins on the
front and rear coils.
Remove screw from top of front panel.
Push down on front panel ;uid pull panel
towards
you to remove from cabinet.
Important: Do
not
reliiove
any gray
expanded polystyrene from inside the air
conditioner. It is not packing material.
Remove the Energy
kdbel
and Consumer
Checklist. To remove any remaining glue,
soak area with liquid hand-dishwashing
detergent before removing with a damp
cloth. Do not use sharp instruments,
flammable fluids, or abrasive cleaner.
These can damage the air conditioner
finish.
Trate el acondicionador de aire con
cuidado. Tenga cuidado con las aletas
de metal filosas de 10s serpentines
delanteros y traseros.
(&Ii
te 10s tornillos dcl panel delantero.
Empuje et panel delantero y jdek) para
separarlo del gabinete.
Importante:
no quite la espuma
de goma
de pohestireno gris extendida de1 interior
del acondicionador de aire. Esto no es
material dc enipaque.
Quite
ka Ctiqieta
de
hergid y bd Chid
del
Comprador.
Pdra
ehminar cuakpiier resto
de goma, vierta sohre la superficie
detergente tiquido para knw
pkdtos y
lfmpiela co
11n paiio
hlimedo. No use
instrumentus Aados, liquidos inflamables
o limpiadores abrasives. Ilstos pueden
tlaliar el acabado del acondicionador de
aire.
Manipuler prudemment le climatiseur.
Les ailettes des Cchangeurs de chaleur
avant et arriilre sont acCr6es.
6ter la vis situ&
au
sammet du
panneau
avant. Appuy vers le has
au
sommet du
pannraii avant, et tire2 le paniicau vers
I’mant poiir le s6parer tie la cdisse.
Important : Nc
jamais cnlever mi
c~uelconquc Mment
de polysty+ne ewpans6
gris qu’on peut troinrr pi I’int6ricur
tlii
climatiseur. Cc n‘est pas on mat&au
d’emballage.
Enlever I’&iquctte d’information
(consommation d’6ncrgie) et la liste de
contrfile du consommateur. Pour Climiner
tout r&Au de colle, mouiller la
zone
affect6e avec
11~
d&t-gent 2 wisselle Iiquide
puis fretter WCC
un
chiffon humide. Se
jamais utiliser d‘instruments x&&s, fluides
inflammables ou produits de nettoydge
abrasifs susceptibles de dbt&iorer la finition
du climatiseur.
Be sure your air conditioner does not
fall out of the opening during
installation.
Air conditioner shauld be placed no more
thw 4 feet (122
cm)
from a grounded
outlet.
Center air conditioner in window. Check
that lower rail of air conditioner is behind
and against back side of window seal. Lower
window sash (A) behind top mounting
channel (B) to hold cabinet in pk~e.
Do not block louvers in air
conditioner cabinet.
Aseghrese de que el acondicionador de
aire no se caiga de la abertura durante
la instalacibn.
I:1 acondicionador de tire debe colocarse a
no mk
de 4 pies (122 cm) de
un
tomacorriente puesto a tierra.
Ccntre el acondicionador de aire en la
ventana.
Venfiqne
qw
el riel inferior del
acondicionador de tire se encuentre detris y
contra la parte posterior del obturador de la
ventana. Baje
el marco de la ventana (A)
d&s de1 canal superior de montaje (B)
pa’” sostener el gabinete en
sii hgar.
No bloquee las rejillas en el gabinete
del acondicionador de aire.
Check that air conditioner cabinet is
tilted to the outside so that water will
run to the outside.
Place level (C) on the top, right side of air
conditioner cabinet. There should be a tilt
to the outside of about t/2 bubble (D).
place level
on
left side of air conditioner
and check that cabinet is tilted properly. If
cabinet is
not
properly positioned,
reposition or shim cabinet to provide the
proper tilt.
DO NOT drill a hole in the bottom of
the metal base and condensate pan.
The water that collects in the condensate
pan
is routed back to the condenser. This
makes the air conditioner run efflcicntly.
Verifique que el acondicionador de aire
estC inclinado hacia el exterior de
manera que el agua corra hacia afuera.
Coloque el nivel (C) en la parte superior
derecha dcl gabinete del acondicionador de
aire. El gabinete debe inclinarse hacia afuera
aprosimadamente l/2 nivel (D). Coloquc cl
nivel al lade izquicrdo de1 acondicionador de
aire y verifiquc qur cl gabinete est6
debidamente inclinado. Si et gabincte no esti
debidamente inclinado, inclinelo
correctamcnte o coloque
SKI
planchita de
relleno debajo de1 gabinete
pard asegurdr la
debida inchnaci6n.
NO perfore ninglin orificio en la parte
inferior de la base de metal y el colector
de condensado. El agrla que se
acumula en
cl colector de codensado welve al
condensador. Esto pennite
que
el
acondicionador de tire funcione
eficientcmente.
Veiller 2 ce que le climatiseur ne
puisse tomber hors de I’ouverture
pendant I’installation.
Le climatiseur ne doit pi Ctre plac6 g
plus
de 122 cm (quatre pieds) d’une prise de
coin-ant retike h la lcrre.
Centrer le climatiseur
dans la fen3re.
Wifier que le rail inf&ur du climatiseur
est placC derri@re la partic arricre
tlii join1
de la fen&e et
en
contact avec cclu-ci.
Faire descendre le chSssis de fenctre (A)
derriere le profil de
montage suphieur
(B)
pour immobiliser la caissc
cn place.
Ne pas obstruer les claires-voies dans
la caisse du climatiseur.
Veiller g ce que la caisse du
climatiseur soit inclinCe vers
I’extCrieur, pour que I’eau puisse
s’Ccouler vers I’extkrieur.
Placer
le niveau (C)
au sommet
de la caisse,
du c8t6 droit. 1.a caisse devrait Ctre inchn6c
\ers l’est6rieur (environ l/2 longueur de la
bulle (D). Placer le nivcau sur le cAt6
gauche et v6rifier que la caisse est
correctenient
inclink Si la caisse n’est pa
en
position con\-enable,
la
repositionnrr ou
utiliser unc tale pour I‘ajuster.
NE PAS perter un trou au fond de la
base mCtallique et du plateau i
condensat.
L’eau qui s’accumnlc ddns le
phteau P
condensat est renvoy&! au
condenseur. Ccci masimise I’efficacit6 de
fonctionnenient du climatiscur.
conlinuedJi-om page 4
~‘iene de Iu p@nu 4
Pull
left curtain (E) out until it fits into the
window channel (F). Repeat with right
curtin.
COrra kd
COrhI
izqliierda (E)
h&d qiie
cncajc en el canal de la ventana (F). Ilaga lo
mismo
con
la cortina derecha.
Top view
Vue du dessus
Insert One of the round-head screws (G)
through left curtain and into the window
ch~mel or through alternate hole (H) at the
top of the curtain and into the window
channel to fasten the curtain to the window.
Repeat for right curtain.
Inserte
ii110
de 10s tornillo cdbeza redonda
(C) a travbs de la cortina izquierda, en el
canal de la ventana o a trav4s de im orificio
alterno (H) en la parte superior de la cortina,
en cl canal de la Wnlaua pard slljetar la
cortina a la ventana. IIagd lo mismo con la
cortina derecha.
Tenir Ic ddeau de
gauche
(E) jusqu‘i son
logcment correct
ddllS Ia rainure de la
fcnCtre (F). RCp6ter pour le ridcau
de
droite.
Ins6rer l’une des vis i t@te ronde (G)
ddns le ridcau
de gauche et dam la
rainure de la fen&e ou perccr
un troo
alternatif (H) au sommct du rideau et
ddns Ia railtim
de la f&tre pour fixer le
rideau B la fenttre. RCphr pour
le rideau
de
droite.
NOTE: Instd window-lock
bracket to
prevent air conditioner from kdlling out of
window.
Place window-lock bracket (A)
on
top of
lower window ;uid against upper window
sash (B). Use a 3/W drill bit to drill a
starter hole through the hole in the bracket.
Attach window-lock bracket.
NOTA: Instde
iin
soporte de seguridad para
la ventana pard wilar
que
cl acondicionador
de aire se caiga de la
ventana.
Coloque cl soporte de seguridad de la
ventana (A) en la parte superior de la
ventana inferior y contra la vidriera de la
ventma
superior (B). Ltilice una broca dc
barrena
de
3/32” para pcrforar cl primer
orificio a trav6s de1 orificio en el soporte. Fije
cl soporte de seguriddd de la ventana.
NOTE: Instdkr la hritk de bhcage
ddns h
fenCtre pour emp&her lc climatiseur de
tomber hors de la fen&-e.
Placer la bride de blocage
de
la fenctre (A)
CII hut
du ch&sis inf&eur, et contre lc
chbsis sup6rieur de la fenCtre (B). Pcrcer
un avant-lrou dans lr cadre i trdwrs le trou
de la bride, avec un forct de
j/.12
po. Fixer
la bride de blocage de la f&tre.
Insert window rail seal (C) behind the top of
the lower
window sash
(D)
and against the
glass of the upper window.
Seal small openings arnund window with
gum-type
scaler.
Place bottom edge of front pane1 on clips and
push down.Then push panel into cabinet until
panel
snaps
in place. Replace screw
Inserte cl obturador del riel de la ventana
(C) d&s de la partc superior de la vidriera
de la vcntana inferior (D) y contra el cristal
de la ventana superior.
Selle las aberturas pequciias alrcdedor de la
ventma con un
sellador tipo goma.
Coloque el borde inferior de1 panel delantero
en los sujetadores y empuje hacia abajo.
Luego empuje el panel en cl gabinete h&a
que encaje en su lugdr. Vuelva a
colocar 10s
tornillos.
Ins&w 1e joint d’CtanchM (C) dans
l’espace, entre le sommet du ch%ssis dc
fenltre infkrieur (D) et la vitre
(III
ch&sis
sup&cur.
Cdlfcutrer les petites ouwtures aulour de la
fenetre, avec un calfcutrdnt en p%e.
Engager Ic bord infcrieur du
pa~mc~u avant
dans les agrafes et appuyr vers lc has.
Pousser ensuite le pauncau contrc la caisse
pour l’cmbt,iter en place. I&staller la vis.
Congratulations!
You
hatle successfully installed your
new air conditioner. To get the most
efficient use from your new air
conditioner, read the Use and Care
Guide section
of this
book.
ifelicitaciones!
Usted ha instalado con &to su
nuevo acondicionador de aire. Para
obtener el uso mds eficiente de su
nuevo acondicionador de aire, lea la
seccidn de Guia de Use y Cuidado de
este folleto.
Fklicitations!
Vous acez rthssi ti installer wtre
nouveau climatiseur. Pour une
utilisation la plus efficace de votre
climatiseur, rleuillez lire le Guide
d’utilisation et d’entretien dans
cette documentation.
5
q
Use and Care Guide
q
Manual de Uso y Cuidado
q
l
Guide d’utilisation et d’entretien
1. Front panel 1. Panel Delantero 1. Panneau avant
2. Air louvers 2. Rejillas del Aire 2. Jalousies
3. Air direction tab
3. Tablilla de Direccih
3. Bouton de rkglage de
4. Control panel
de Aire
la circulation de I’air
5. Side curtains 4. Panel de Control 4. Tableau de commande
6. Slide-out filter 5. Cortinas laterales 5. Rideaux lathaux
6. Filtro deslizable 6. Filtre amovible
ROOM AIR
CONDITIONER
ACONDICIONADOR
DE AIRE
CLIMATISEUR
1172397
0 1997 Whirlpool Corporation
Printed in U.S.A.
lmpreso en 10s EE,UU.
Imprime aux E.-U.
q
Contents
Page
Page
A Note To You .................................................................
3
Performing Annual
Maintenance .................................
17
Air Conditioner Safety
....................................................
5
Troubleshooting
............................................................
20
Important Safety Instructions
........................................
5
Ordering Accessories
...................................................
26
Operating Your Air Conditioner..
...................................
8
Requesting Assistance or Service in the U.S.A..
...... .27
Starting your air conditioner
................................... 8
Requesting Assistance or Service in Canada..
......... .29
Changing air direction
............................................. 9
Warranty.. .......................................................................
31
Saving energy
...........................................................
9
Using the Filter Monitor
........................................... 9
Normal operating sounds
........................................
9
Caring for Your Air Conditioner..
.................................
14
Cleaning the front
panel ........................................
14
Cleaning the air filter
..............................................
14
Repairing paint damage..
.......................................
14
q
Contenido
Paginti
Paging
Una Nota para Usted ......................................................
3
Reparation
de la pintura dafiada ..........................
15
Seguridad del acondicionador de aire
.........................
6
Mantenimiento
anual ....................................................
18
lnstrucciones importantes de seguridad
.....................
6
Diagnostico de
problemas ...........................................
22
Coma usar su acondicionador de
aire.. ......................
10
Coma ordenar
accesorios ............................................
26
Coma poner en marcha su
Coma solicitar ayuda
o servicio tecnico
.................... 28
acondicionador de
aire ..........................................
10
Garantfa
.........................................................................
32
Coma cambiar la direction
del aire.. ....................
11
Ahorro de energia
..................................................
11
Coma usar el monitor
del filtro .............................
11
Ruidos normales de
operation .............................
11
Coma cuidar su acondicionador de aire..
...................
15
Limpieza del panel
delantero ................................
15
Limpieza del filtro
de aire ......................................
15
q
l
Table des matikes
Page
Page
Note a I’utilisateur ...........................................................
4
Entretien annuel
............................................................ 19
Instructions de securite
- climatiseur ...........................
7
Diagnostic ......................................................................
24
Importantes instructions
de securite ............................
7
Commande d’accessoires
............................................
26
Utilisation du climatiseur
.............................................
12
Demande d’assistance ou de service au Canada
..... .30
Mise en marche du climatiseur
.............................
12
Garantie.. ........................................................................
33
Modification de la direction des jets d’air..
..........
13
konomie d’energie
...............................................
13
Utilisation du controleur de filtre
......................... 13
Sons du fonctionnement normal
.........................
13
Entretien du climatiseur
...............................................
16
Nettoyage du panneau
avant
................................ 16
Nettoyage du filtre
a air .........................................
16
Reparation de la peinture
......................................
16
2
q
A Note To You
Thank you for buying this appliance.
To ensure you enjoy years of trouble-free operation, we
developed this Use and Care Guide. It contains valuable
information about how to operate and maintain your
appliance properly and safely. Please read it carefully.
Also, please complete and mail the Product Registration
Card provided with your appliance. This card helps us
notify you about any new information on your appliance.
Model Number
Serial Number
Please record your model’s information.
Whenever you call to request service on your appliance,
you need to know your complete model number and
serial number. You can find this information on the model
and serial number label. (See Installation Instructions for
model and serial number location.)
Please record the model and serial number information
below. Also, record the purchase date of your appliance
and the store’s name, address, and telephone number.
Store Name
Store Address
Purchase Date
Store Phone
Keep this book and the sales slip together in a safe place for future reference.
q
Una Nota para Usted
Gracias por seleccionar este aparato.
Para asegurar que este aparato funcione durante muchos
arias sin problemas, hemos diseiiado este Manual de Uso
y Cuidado. Contiene valiosa information sobre coma
operar y dar mantenimiento a su aparato debidamente
y sin peligro. Por favor, lealo detenidamente. Asimismo,
llene por favor y envie por correo la Tarjeta de Registro
del Product0 que viene con su aparato. Esta tarjeta nos
ayudara a notificarle cualquier information nueva sobre
su aparato.
Numero del modelo
Numero de serie
Fecha de compra
Por favor anote la informacibn sobre su
modelo.
Siempre que llame para solicitar servicio del aparato,
necesitara saber el numero del modelo y el numero de
serie completes. Esta information la encuentra en la placa
de numero del modelo y numero de serie.(Ver la ubicacion
del numero del modelo y del numero de serie en las
lnstrucciones de Instalacion.)
Por favor anote la information sobre el numero del
modelo y el numero de serie que se incluye abajo.
Anote tambien la fecha de compra del aparato, asi
coma el nombre, la direction y el telefono de la tienda.
Nombre de la tienda
Direction de la tienda
Telefono de la tienda
Guarde este manual y la nota de compra juntos, en un lugar seguro para referencia futura.
3
q
Air Conditioner Safety
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This is the safety alert symbol.
This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER” or
“WARNING.” These words mean:
You will be killed or seriously injured if you don’t
follow instructions.
You can be killed or seriously injured if you don’t
follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen
if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To reduce the risk of fire, electrical shock, injury, or sickness when using your air conditioner, follow
these basic precautions:
l
Plug into a grounded 3 prong outlet.
l
Unplug air conditioner before servicing.
l
Do not remove ground prong.
l
Use two or more people to move or install air
l
Do not use an adapter.
conditioner.
l
Do not use an extension cord.
l
Do not drink water collected inside the cabinet,
- SAVE THESE INSTRUCTIONS-
Help us help you
Please:
l
Install your air conditioner in a window that will hold the
weight, and secure the air conditioner according to the
Installation Instructions.
l
Connect the air conditioner to the proper kind of outlet
with the correct electrical supply and ground. (See the
Installation Instructions.)
l
Make sure the air conditioner is the correct size for the
area you want to cool
l
Use the air conditioner only to do what a window air
conditioner is designed to do.
l
Make sure the air conditioner is not used by anyone
unable to operate it properly.
l
Maintain the air conditioner properly.
Also, remove the Energy Label. Use a damp cloth to take
off any glue residue. DO NOT use sharp instruments,
5
q
Operating Your Air Conditioner
Operating your air conditioner properly enables you to obtain the best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
l If you turn the air conditioner off, wait at least 3 minutes before turning it back on. This prevents the air conditioner
from blowing a fuse or tripping a circuit breaker.
l Do not try to operate your air conditioner when outside temperature is below 65°F (18°C). The inside evaporator coil
will freeze up and the air conditioner will not operate properly.
Starting your air conditioner
1. Set the VENT Control to CLOSED for maximum cooling. The vent control
allows you to draw stale or smoky air from the room.
OPEN - to exhaust room air to the outside.
CLOSED - to circulate room air.
The VENT Control will function only when MODE Control is operating.
2. Set the MODE Control to the desired setting.
When the air conditioner is operating at LOW COOL,
MED COOL, or HIGH COOL, the fan circulates air
continuously.
HIGH COOL - for maximum cooling
MED COOL - for normal cooling
LOW COOL - for sleeping comfort
FAN ONLY MODE
When the FAN ONLY setting is selected, the fan will run
continuously to move air, but the air will not be cooled.
POWER SAVER MODE
When the air conditioner is operating on POWER
SAVER, the fan runs only when cooling is needed. The
fan stops circulating air when the room temperature
matches the TEMP Control setting.
NOTE: The POWER SAVER MODE is designed to save
energy. Since the fan does not circulate the room air
continuously, less energy is used but the room air is not
circulated as often. Use POWER SAVER when you are
away from home or asleep. Use LOW COOL, MED
COOL, or HIGH COOL for your best comfort.
3. Turn the TEMP Control to a mid-setting. Adjust the air
conditioner’s performance by turning the TEMP Control
clockwise (3) for maximum cooling. For less cooling,
turn the TEMP Control counterclockwise (3).
Experiment and find the setting that suits you best.
8
Changing air direction
The louvers in the top of the front panel allow you to
control the direction of the cooled air. Use the tabs to
direct the air up, down, right, left, or straight ahead.
Saving energy
Along with using the POWER SAVER MODE, there are many things you can do to help save energy.
l Improve your home’s insulation. Seal doors and
l Ventilate your attic. High temperatures in the attic add to
windows. Close fireplace flue.
the air conditioner’s cooling load.
l Close blinds or drapes on the sunny side of your house.
l Try not to use heat-producing appliances during the
Add awnings.
hottest part of the day.
l Make sure drapes or furniture do not block airflow from
l Keep heat registers and cool-air returns closed.
your air conditioner.
l Use exhaust vent fans while cooking, doing laundry, or
l Turn lights and appliances off when they are not
bathing.
needed.
Using the Filter Monitor
The Filter Monitor tells you when the filter needs to be
IMPORTANT: The MODE Control must be set to HIGH
1
cleaned. When the amount of dirt
COOL for the Filter Monitor to work. If the MODE Control
on the filter reaches a level that
FILTER
is set to a lower fan speed, turn the setting to HIGH
would affect cooling perfomance, a
COOL to check the filter. Then return the MODE Control
MONITOR
red flag appears under the words
to your desired setting.
0
“FILTER MONITOR” on the control
panel.
I
I
Normal operating sounds
When your air conditioner is operating normally, you may hear sounds such as:
l Droplets of water hitting the condenser, causing a
l Clicks from the thermostat cycle.
“pinging” or “clicking” sound. The water droplets
l Vibrations or noise due to poor wall or window
help cool the condenser.
construction.
l Air movement from the fan.
l A high-pitched hum or pulsating noise caused by the
modern high-efficiency compressor cycling on and off.
9
q
Caring for Your Air Conditioner
Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean
and care for your air conditioner properly. Call your local authorized dealer for an annual checkup. Remember... the cost
of this service call is your responsibility.
Cleaning the front panel
1.
2.
3.
4.
5.
6.
7.
Unplug air conditioner or disconnect power.
Remove the air filter and clean it separately.
(See “Cleaning the air filter,” below).
Remove the screw from top of the front panel. Press
down on top of the front panel and tilt forward. Lift panel
up and away from the cabinet.
Clean front panel with warm water and mild soap or
detergent. Use a soft cloth. Rinse and dry thoroughly.
Wipe control panel with a soft, dry cloth.
Set bottom of panel on cabinet spring clips. Push panel
down and forward into cabinet. Replace screw.
Plug in air conditioner or reconnect power.
Cleaning the air filter
The air filter is removable for easy cleaning. A clean filter
helps remove dust, lint, and other particles from the air
and is important for best cooling and operating efficiency.
Check the filter every 2 weeks to see if it needs cleaning.
Do not operate the air conditioner without the filter in
place.
1. Unplug air conditioner or disconnect power.
2. Slide the air filter up and out the top of the front panel.
3. Clean the filter using a vacuum cleaner. If the filter is
very dirty, wash it in warm water with mild detergent.
Do not wash the air filter in the dishwasher or use any
chemical cleaners.
Air dry filter thoroughly before
replacing to ensure maximum efficiency.
4. Slide the air filter back down into opening in the top of
the front panel.
5. Plug in air conditioner or reconnect power.
Repairing paint damage
Check once or twice a year for paint damage. This is
NOTE:
To reduce paint damage during the winter, install
very important, especially in areas near oceans or where
a heavy-duty cover over air conditioner cabinet. For
rust is a problem. If needed, touch up with a good grade
information on ordering a heavy-duty cover, see page 26.
enamel paint.
14
q
Performing Annual Maintenance
Electrical Shock Hazard
Disconnect power before doing any maintenance.
Do not drink water collected by the air
conditioner.
Failure to follow these instructions can result in
death, electrical shock, or sickness.
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
Your air conditioner needs annual maintenance to help
ensure steady, top performance throughout the year.
Call your local authorized dealer to schedule an annual
checkup. The expense of an annual inspection is your
responsibility.
OR
If you are familiar with electrical appliances, you can do
the cleaning and maintenance yourself. If you choose to
do so, follow these steps:
NOTE: Do not lift, push, or pull on any expanded gray
polystyrene from inside the air conditioner.
1. Unplug air conditioner or disconnect power.
2. Remove the air conditioner from the window.
3. Remove the front panel (See “Cleaning the front panel”
on page 14.)
4. Remove the side curtains. Slide curtains out to fullest
width. From the back side, remove the Phillips-head
screws which attach the curtain to the cabinet (A).
5. Remove slotted-hex head screws (B) holding top
channel.
6. Remove slotted-head screws (C) on sides of cabinet.
7. Holding the cabinet on both sides, carefully lift cabinet
off base. Watch out for the sharp metal fins on the front
and rear coils.
8. Wrap the fan motor(D), capacitor terminals (E),
electrical control box (F), and compressor terminals (G)
in plastic film and make sure no water or other liquid
gets inside any of these parts. It could damage the
insulation and cause serious mechanical problems.
9. Carefully clean and hose out the base (H), condenser
coil (I), evaporator coil (J), and condensate pan (K).
Clean at least once a year or more often if the
condenser and evaporator coils and pan collect dirt,
sand, leaves, insects, or algae. Also, clean if you detect
an odor coming from the air conditioner.
10. Remove the plastic film from the motor and electrical
parts.
11. Replace the cabinet on the air conditioner and reattach
the front panel, top channel and side curtains. Tighten
all screws.
NOTE: It is a good idea to wait 24 hours before starting
the air conditioner again. This allows time for all areas to
dry out.
12. Plug in air conditioner or reconnect power.
17
q
Troubleshooting
You can solve many common air conditioner problems easily, saving you the cost of a service call. Try the suggestions
below to see if you can solve your problem without outside help.
Air conditioner will not operate
1 Check if . . .
1 Then . . .
I
The power supply
cord is unplugged.
A household fuse
has blown or circuit
breaker has triooed.
Firmly plug the power supply cord into a live outlet with proper voltage.
Replace the fuse or reset the circuit breaker. Make sure the air conditioner is plugged into a
properly grounded outlet as described in the Installation Instructions.
The MODE Control is
turned to the OFF
position.
Turn the MODE Control to an active setting.
The local power has
failed.
Wait for power to be restored.
Air conditioner blows fuses or trips circuit breakers
Check if . . .
Then . . .
Too many appliances
Unplug or relocate appliances that share the same circuit.
are being used on the
same circuit.
Time-delay fuse or
Replace with a 15-amp time-delay fuse or circuit breaker of the correct capacity. See
circuit breaker of the
“Electrical requirements” in the Installation Instructions for the correct capacity.
wrong capacity is
being used.
An extension cord is
Do not use an extension cord with this or any other appliance.
being used.
You are trying to
Wait at least 3 minutes after turning MODE Control off before trying to restart the air
restart the air
conditioner.
conditioner too soon
after turning MODE
Control off.
Air conditioner seems to run too much
Check if . . .
The current air
conditioner replaced
an older model.
Then . . .
The use of more efficient components may cause the air conditioner to run longer than
an older model, but the total energy consumption will be less. Newer air conditioners do not
emit the “blast” of cold air you may be accustomed to from older units, but this IS NOT an
indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER) and
capacity rating (in BTUs/hr.) marked on the air conditioner.
The air conditioner
is in a heavily
occupied room or
heat-producing
appliances are in
use in the room.
Use exhaust vent fans while cooking or bathing and try not to use heat-producing appli-
antes during the hottest part of the day. A higher capacity air conditioner may be required
depending on the size of the room being cooled.
20
Air conditioner on and off too much, or does not cool room
Check if . . .
Then . . .
MODE Control is set to
Use POWER SAVER only when you are away from home or asleep, since the fan
POWER SAVER.
does not circulate the room air continuously. Use LOW COOL, MED COOL or HIGH
COOL for your best comfort.
The air conditioner is not
Check the cooling capabilities of your room air conditioner. Room air conditioners are
properly sized for your room.
not designed to cool multiple rooms.
The filter is dirty or
Clean the filter. See page 14.
obstructed by debris.
The inside evaporator and
Clean the inside evaporator and outside condenser coils. See page 17.
outside condenser coils are
dirty or obstructed by debris.
There is excessive heat or
Use a fan to exhaust heat or moisture from the room. Try not to use heat-producing
moisture (open container
appliances during the hottest part of the day.
cooking, showers, etc.)
in the room.
The louvers are blocked.
Install the air conditioner in a location where the louvers are free from curtains, blinds,
furniture, etc.
The outside temperature is
Do not try to operate your air conditioner when the outside temperature is below
below 65°F (18°C).
65°F (18%).
The temperature of the room
Allow extra time for the air conditioner to cool off a very hot room.
you are trying to cool
is extremely hot.
Windows or doors to the
Close all windows and doors.
outside are open.
The VENT Control is
Set the VENT Control to CLOSED for maximum cooling.
set to OPEN.
The TEMP Control is not at a
Adjust the TEMP Control to a cooler setting by turning the knob clockwise. Turn MODE
cool enough setting.
Control to HIGH COOL.
The air conditioner is
Install your air conditioner in a more shaded window.
installed on the sunny
side of your house.
Water drips from cabinet into your house
Check if . . .
1 Then . . .
The air conditioner is not
properly leveled. The air
conditioner should slope
slightly downward toward
the outside.
Level the air conditioner to provide a downward slope toward the outside (‘/2 bubble
on a carpenter’s level) to ensure proper drainage. See the Installation Instructions.
Reposition or shim the cabinet as necessary.
NOTE: Do NOT drill a hole in the bottom of the metal base and condensate pan.
21
q
Ordering Accessories
You can order the following accessories for your air
Installation kits
conditioner from your local authorized dealer or by calling
l-800-253-1301 from anywhere in the U.S.A. You will
hear a recording. Follow the instructions to place an order.
In Canada, see an authorized dealer or see “Requesting
Assistance or Service in Canada” on page 29.
A standard installation kit is included with your air condi-
tioner. These special installation kits are available:
l Outside Sill Bracket Kit
l Wide-Window Kit
Replacement air filters
Heavy-duty cover
A good, clean air filter is important for best cooling with
If you decide to leave your air conditioner installed during
least energy consumption. Your air filter should be cleaned
the winter, a heavy-duty cover will help protect your air
regularly. See page 14 for cleaning instructions. We
conditioner and reduce drafts. The cover protects against
suggest you replace your air filter once a year.
cold drafts through the unit’s air passages and protects the
cabinet from snow, rain, sleet, rust, and dust.
For a heavy-duty cover sized to fit your air conditioner,
order part #484069.
q
C6mo ordenar accesorios
Usted puede ordenar 10s siguientes accesorios para su
acondicionador de aire en la tienda de aparatos electro-
domesticos de su localidad.
Filtros de aire de reemplazo
Un filtro de aire limpio y de buena calidad es importante
para obtener el mejor enfriamiento con el menor consume
de energia. Limpie regularmente el filtro de aire. Vea las
instrucciones de limpieza en la pagina 15. Le recomen-
damos cambiar su filtro de aire una vez al aiio.
Juego de accesorios de instalacih
Se incluye un juego de accesorios de instalacion estandar
con su acondicionador de aire. Estan disponibles 10s
siguientes juegos de instalacion especiales:
l Juego de sopotte para instalacion en el marco de una
ventan
l Juego para instalacion en ventana ancha
Cubierta resistente
Si usted decide dejar instalado su acondicionador de aire
durante el invierno, una cubietta resistente ayudara a
proteger su aparato y reducir las corrientes de aire. La
cubierta protege contra las corrientes de aire frio a traves
de 10s orificios de paso de aire de la unidad y protege el
gabinete contra la nieve, la Iluvia, el agua nieve, la
oxidation y el polvo.
Para obtener una cubierta resistente del tamaho adecuado
para su acondicionador de aire, ordene pieza #484069.
Commande d’accessoires
II est possible de commander les accessoires suivants pour
le climatiseur, d’un magasin local d’appareils menagers. Voir
un marchand autorise ou voir “Demande d’assistance ou de
service au Canada” a la page 30.
Filtre 5 air de remplacement
Un filtre a air propre et en bon &at joue un role important
pour I’obtention du meilleur refroidissement et de la plus
basse consommation d’energie. II convient de nettoyer le
filtre a air a intervalles reguliers. Voir les instructions de
nettoyage a la page 16. On suggere que le filtre a air soit
remplace une fois par an.
Ensembles d’installation
Un ensemble d’installation standard est fourni avec le
climatiseur. Des ensembles d’installation speciaux sont
disponibles :
l Ensemble de brides pour appui exterieur
l Ensemble pour fenetre large
Housse (service rigoureux)
Si on choisit de laisser le climatiseur install4 pendant
I’hiver, une housse de protection pour service rigoureux
le protegera et eliminera les courants d’air. La housse
protege contre le passage de I’air froid a travers I’appareil,
et protege le climatiseur contre neige, pluie, givre, rouille
et poussiere. Pour obtenir une housse (service rigoureux)
de dimensions adaptees a celle du climatiseur, com-
mander la piece no 484069.
26
q
Requesting Assistance or Service
To avoid unnecessary service calls, please check the “Troubleshooting Guide” section. It may save you the cost of a
service call. If you still need help, follow the instructions below.
If you need assistance or service in the U.S.A.
Call the Consumer Assistance Center telephone
number. Dial toll-free l-800-253-1301. Our consultants
are available to assist you.
When calling: Please know the purchase date, and the
EJ
complete model and serial number of your
w
appliance (see the “A Note to You” section).
Thus rnformation will help us better respond to
your request.
Our consultants provide assistance with:
l
Features and specifications on our full line of appliances
l
Installation information
l
Use and maintenance procedures
l
Accessory and repair parts sales
l
Specialized customer assistance
(Spanish speaking, hearing impaired, limited vision, etc.)
l
Referrals to local dealers, service companies, and repair
parts distributors
Our service technicians are trained to fulfill the product
warranty and provide after-warranty service, anywhere in
the United States.
To locate the authorized service company in your area,
you can also look in your telephone directory Yellow
Pages.
If you need replacement parts
If you need to order replacement parts, we recommend
To locate factory-authorized parts in your area, call our
that you only use factory-authorized parts. These parts will
Consumer Assistance Center telephone number, your
fit right and work right, because they are made to the same
nearest authorized service center, or Factory Service at
exacting specifications used to build every new appliance.
l-800-442-1 111.
For further assistance
If you need further assistance, you can write to ask
any questions or tell us about your concerns to:
Consumer Assistance Center
c/o Correspondence Dept.
2000 North M-63
Benton Harbor, Ml 49022-2692
Please include a daytime phone number in your
correspondence.
27
q
Requesting Assistance or Service
Before calling for assistance or service, please check the “Troubleshooting” section. It may save you the cost of a service
call. If you still need help, follow the instructions below.
If you need assistance or service in Canada
1. If the problem is not due to one of the
items listed in “Troublshooting+ . . .
w
Contact the dealer from whom you
w purchased your appliance, or call the lnglis
Limited Consumer Assistance Centre
toll-free, 8:30 a.m. - 6 p.m. (EST), at
l-800-461 -5681.
2. If you need service+ . . .
Contact your nearest lnglis Limited Appliance Service
branch or authorized servicing outlet to service your
appliance. (See list below.) Make sure the service
company you contact is authorized to service your
appliance during the warranty period.
f When asking for assistance or service, please
provide a detailed description of the problem, your
appliance’s complete model and serial numbers, and
the purchase date. (See the “A Note to You” section.)
This information will help us respond properly to your
request.
Direct service branches:
BRITISH COLUMBIA
1-600-665-6766
ALBERTA
l-800-661-6291
ONTARIO
Ottawa area
l-600-267-3456
(except 807 area code)
Outside the Ottawa area
1-800-807-6777
MANITOBA, SASKATCHEWAN and 807 area code in ONTARIO
l-600-665-1 663
QUEBEC
Montreal (except South Shore)
l-600-361 -3032
South Shore Montreal
l-800-361 -0950
Quebec City
l-600-463- 1523
Sherbrooke
l-600-567-6966
ATLANTIC PROVINCES
i-800-565-1598
For further assistance
If you need further assistance, you can write to
lnglis Limited with any questions or concerns at:
Please include a daytime phone number in your
correspondence.
Consumer Relations Department
lnglis Limited
1901 Minnesota Court
Mississauga, Ontario L5N 3A7
29
LENGTH OF WARRANTY WE WILL PAY FOR
FULL ONE-YEAR
Replacement parts and repair labor to correct defects in materials or workmanship.
WARRANTY
Service must be provided by an authorized service company.
FROM DATE OF
PURCHASE
FULL FIVE-YEAR
WARRANTY
FROM DATE OF
PURCHASE
Replacement parts and repair labor to correct defects in materials or workmanship in the
sealed refrigeration system. These parts are:
1. Compressor
4. Drier-Strainer
2. Evaporator 5. Connecting Tubing
3. Condenser
Service must be provided by an authorized service company.
WE WILL NOT PAY FOR
A. Service calls to:
1. Correct the installation of your air conditioner.
2. Instruct you how to use your air conditioner.
3. Replace house fuses or correct house wiring.
4. Clean or replace the air filter.
B. Pickup and delivery. Your air conditioner is designed to be repaired in the home.
C. Damage to your air conditioner caused by accident, misuse, fire, flood, acts of God, or use of products not
mentioned in this manual.
D. The removal and reinstallation of your air conditioner if it is installed in an overhead or other inaccessible location
or is not installed in accordance with published Installation Instructions.
E. Repairs to parts or systems resulting from unauthorized modifications made to the appliance.
F. In Canada, travel or transportation expenses for customers who reside in remote areas.
1297
WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some
states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so this exclusion or
limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state or province to province.
Outside the United States and Canada a different warranty may apply. For details, please contact your authorized
dealer.
If you need service, first see the ‘Troubleshooting” section of this book. After checking ‘Troubleshooting,” additional
help can be found by checking the “Requesting Assistance or Service” section, or by calling the Whirlpool Corporation
Consumer Assistance Center telephone number, l-800-253-1301, from anywhere in the U.S.A. For service in Canada,
see the “Requesting Assistance or Service in Canada” on page 29.
31
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Whirlpool 1172397 User manual

Category
Split-system air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI