16 | Technical guide WPL 09/17 ICS/IKCS www.stiebel-eltron.com
Inverter air|water heat pumps
WPL 09/17 ICS/IKCS
Specification
WPL 09 ICS
classic
WPL 17 ICS
classic
WPL 09 IKCS
classic
WPL 17 IKCS
classic
236375 236376 236377 236378
Heat output
Heating output at A7/W35 (min./max.) kW 1,3/4,5 2,5/9,0 1,3/4,5 2,5/9,0
Heating output at A2/W35 (min./max.) kW 1,3/4,5 2,7/9,0 1,3/4,5 2,7/9,0
Heating output at A-7/W35 (min./max.) kW 1,3/4,2 2,9/8,0 1,3/4,2 2,9/8,0
Output at A10/W35 (EN 14511) kW 1,98 4,34 1,98 4,28
Output at A7/W35 (EN 14511) kW 2,06 4,27 2,06 4,22
Output at A7/W55 (EN 14511) kW 2,10 3,81 2,10 3,75
Output at A2/W35 (EN 14511) kW 2,64 5,02 2,62 4,95
Output at A2/W55 (EN 14511) kW 2,39 4,42 2,37 4,34
Output at A-7/W35 (EN 14511) kW 4,23 8,02 4,18 7,80
Output at A-7/W55 (EN 14511) kW 3,93 3,14 3,89 3,03
Output at A-15/W35 (EN 14511) kW 3,64 6,29 3,45 6,21
Heating output at A-20/W35 (EN 14511) kW 3,16 5,24 2,99 5,13
Cooling capacity at A35/W18 max. kW 3,00 6,00 3,00 6,00
Cooling capacity at A35/W18 partial load kW 1,85 3,60 1,85 3,60
Cooling capacity at A35/W7 max. kW 3,00 5,25 3,00 5,25
Cooling capacity at A35/W7 partial load kW 1,44 3,27 1,44 3,27
Heating output in silent mode at A-7/W35 (70 %) kW 3,12 5,14 3,12 5,14
Power consumption
Power consumption at A10/W35 (EN 14511) kW 0,40 0,83 0,40 0,85
Power consumption at A7/W35 (EN 14511) kW 0,44 0,90 0,44 0,92
Power consumption at A7/W55 (EN 14511) kW 0,80 1,48 0,80 1,49
Power consumption at A2/W35 (EN 14511) kW 0,69 1,31 0,70 1,34
Power consumption at A2/W55 (EN 14511) kW 1,03 1,94 1,04 1,96
Power consumption at A-7/W35 (EN 14511) kW 1,34 3,03 1,36 3,02
Power consumption at A-7/W55 (EN 14511) kW 1,83 1,58 1,84 1,56
Power consumption at A-15/W35 (EN 14511) kW 1,36 2,55 1,31 2,56
Power consumption at A-20/W35 (EN 14511) kW 1,26 2,25 1,27 2,26
Power consumption, emergency/booster heater kW 5,9 5,9 5,9 5,9
Coefficient of performance (COP)
Coefficient of performance at A10/W35 (EN 14511) 4,95 5,20 4,95 5,04
Coefficient of performance at A7/W35 (EN 14511) 4,68 4,74 4,68 4,60
Coefficient of performance at A7/W55 (EN 14511) 2,64 2,58 2,64 2,51
Coefficient of performance at A2/W35 (EN 14511) 3,83 3,83 3,76 3,70
Coefficient of performance at A2/W55 (EN 14511) 2,33 2,27 2,28 2,21
Coefficient of performance at A-7/W35 (EN 14511) 3,16 2,63 3,07 2,58
Coefficient of performance at A-7/W55 (EN 14511) 2,15 1,99 2,11 1,94
Coefficient of performance at A-15/W35 (EN 14511) 2,68 2,47 2,63 2,43
COP at A-20/W35 (EN 14511) 2,50 2,33 2,35 2,27
SCOP (EN 14825) 4,53 4,25 4,45 4,13
Cooling capacity factor at A35/W18 max. 2,22 1,83 2,02 1,63
Cooling capacity factor at A35/W18 partial load 3,96 2,78 3,76 2,58
Cooling capacity factor at A35/W7 max. 2,11 1,56 1,91 1,36
Cooling capacity factor at A35/W7 partial load 2,61 2,00 2,41 1,80
Sound data
Sound power level indoor installation (EN 12102) dB(A) 45 51 45 50
Sound power level, indoor installation max. dB(A) 53 59 51 56
Sound power level for indoor installation in silent mode 70 % dB(A) 52 56 50 55
Max. sound power level for indoor installation in silent mode dB(A) 45 51 45 49
Sound power level indoor installation, air intake/discharge (EN 12102) dB(A) 30/32 43/48 29/32 40/44
Max. sound power level, indoor installation, air intake/discharge dB(A) 46/51 48/52 43/48 47/50
Sound power level for indoor installation at air intake/discharge in silent mode 70 % dB(A) 45/49 49/50 43/48 44/48
Max. sound power level for indoor installation at air intake/discharge in silent mode dB(A) 30/32 43/48 29/32 40/44