Manitowoc CVD1375 User manual

Category
Ice cube makers
Type
User manual

This manual is also suitable for

Thank you for selecting a Manitowoc Ice Machine, the dependability leader in ice making equipment and related products.
With proper installation, care and maintenance, your new Manitowoc Ice Machine will provide you with many years of
reliable and economical performance.
Q Model
QuietQube® Ice Machines
with CVD® Technology
Models Q1400C
Installation
and
Owner/Operator
Use and Care Manual
Part Number 000001528
8/2006
We reserve the right to make product improvements at any time.
Specifications and design are subject to change without notice.
Safety Notices
As you work on a QuietQube®-Series Ice Machine, be
sure to pay close attention to the safety notices in this
manual. Disregarding the notices may lead to serious
injury and/or damage to the ice machine.
Throughout this manual, you will see the following types
of safety notices:
Procedural Notices
As you work on a QuietQube®-Series Ice Machine, be
sure to read the procedural notices in this manual.
These notices supply helpful information which may
assist you as you work.
Throughout this manual, you will see the following types
of procedural notices:
NOTE: Text set off as a Note provides you with simple,
but useful, extra information about the procedure you
are performing.
Read These Before Proceeding:
!
Warning
PERSONAL INJURY POTENTIAL
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
!
Warning
Text in a Warning box alerts you to a potential
personal injury situation. Be sure to read the
Warning statement before proceeding, and work
carefully.
!
Caution
Text in a Caution box alerts you to a situation in
which you could damage the ice machine. Be sure
to read the Caution statement before proceeding,
and work carefully.
Important
Text in an Important box provides you with
information that may help you perform a procedure
more efficiently. Disregarding this information will
not cause damage or injury, but it may slow you
down as you work.
!
Caution
Proper installation, care and maintenance are
essential for maximum ice production and trouble-
free operation of you Manitowoc Ice Machine.
Read and understand this manual. It contains
valuable care and maintenance information. If you
enounter problems not covered by this manual, do
not proceed, contact Manitowoc Ice, Inc. We will be
happy to provide assistance.
Important
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
Part Number 000001528 1
Table of Contents
Section 1
General Information
Model Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
How to Read a Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Remote Condensing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Ice Cube Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
CVD1476 Water Cooled Condensing Unit . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Bin Caster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Ice Bagger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Ice Deflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Water Filter System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Manitowoc Cleaner and Sanitizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Dispenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Aucs® Automatic Cleaning System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
GSI200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Model/Serial Number Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Owner Warranty Registration Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Warranty Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Labor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Exclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Authorized Warranty Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Service Calls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Section 2
Installation Instructions
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Ice Machine Installation Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
CVD1476 Condenser Water Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Q1400C Head Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Ice Machine Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Q1400C Ice Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Condensing Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
CVD1475
Air-Cooled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
CVD1476
Water-Cooled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Ice Storage Bin Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Ice Machine Head Section Clearance Requirements . . . . . . . . . . . . . . . . . . . 2-4
Stacking Two Ice Machines on a Single Storage Bin . . . . . . . . . . . . . . . . . . . 2-4
Location of CVD Condensing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Condensing Unit Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Condensing Unit Heat of Rejection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Leveling the Ice Storage Bin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Air-Cooled Baffle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Table of Contents (continued)
2 Part Number 000001528
Electrical Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Fuse/Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Minimum Circuit Ampacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
QuietQube® Ice Machine Head Section Electrical Wiring Connections . . . . 2-8
QuietQube® Ice Machine Head Section
115/1/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
QuietQube® Ice Machine Head Section
230/1/50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
For United Kingdom Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Remote Electrical Wiring Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
CVD Condensing Unit 208-230/1/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
CVD Condensing Unit 208-230/3/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
CVD Condensing Unit 230/1/50 (CVD1475 Only) . . . . . . . . . . . . . . . . . . . . 2-9
Ice Machine Head Section Water Supply and Drains . . . . . . . . . . . . . . . . . . . 2-10
Potable Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Potable Water Inlet Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Drain Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Water Cooled Condenser Water Supply and Drains . . . . . . . . . . . . . . . . . . . . 2-10
Condenser Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Water Cooled Condenser Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Condensing Unit Drain Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Water Supply and Drain Line Sizing/Connections . . . . . . . . . . . . . . . . . . . . 2-11
Refrigeration System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Usage With Non-Manitowoc
Condensing Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Refrigeration Line Set Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
A. Line Set Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
B. Line Set Rise or Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
C. Suction Line Oil Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Before Starting the Ice Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
AuCS® Automatic Cleaning System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
Section 3
Ice Machine Operation
Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Ice Machine Head Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
CVD Condensing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Ice Making Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Initial Start-Up or Start-Up After Automatic Shut-Off . . . . . . . . . . . . . . . . . . 3-3
Freeze Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Harvest Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Automatic Shut-Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Operational Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Water Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Water float valve check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Ice Thickness Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Table of Contents (continued)
Part Number 000001528
3
Section 4
Maintenance
Interior Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Cleaning and Sanitizing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Ice Machine Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Cleaning the Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Water-Cooled Condenser and Water Regulating Valve . . . . . . . . . . . . . . . 4-9
Removal from Service/Winterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
CVD 1476 Water Cooled Condensing Unit . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
AuCS Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Section 5
Before Calling For Service
Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Safety Limit Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Table of Contents (continued)
4 Part Number 000001528
Part Number 000001528 1-1
Section 1
General Information
Model Numbers
This manual covers the following models:
For 3 phase electrical option: add the number “3” to the
end of model number (CVD14753).
How to Read a Model Number
Remote Condensing Unit
Ice Cube Sizes
Ice Machine Head Section CVD® Condensing Unit*
QD1472C
QY1474C
CVD1375
CVD1475
CVD1476
!
Warning
PERSONAL INJURY POTENTIAL
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
!
Warning
When installing with non-Manitowoc ice storage
systems or Manitowoc F & B style bins. Manitowoc
QuietQube® ice machines require the ice storage
bin, to incorporate an ice deflector.
Prior to using a non-Manitowoc ice storage system
with Manitowoc ice machines, contact the
manufacturer to assure their ice deflector is
compatible with Manitowoc ice machines.
Dice
7/8" x 7/8" x 7/8"
2.22 x 2.22 x 2.22 cm
Half Dice
3/8" x 1-1/8" x 7/8"
0.95 x 2.86 x 2.22 cm
Important
The ice machine sequence of operation for QuietQube®
ice machines will differ. Verify the correct sequence of
operation is followed for the model you are working on.
Q Y 0674 C
ICE MACHINE
MODEL
ICE CUBE SIZE
D DICE
Y HALF DICE
# CUBE SIZE
2 DICE
3 DICE
4 HALF-DICE
5 HALF-DICE
CONDENSER TYPE
AIR-COOLED
WATER-COOLED
AIR-COOLED
WATER-COOLED
A SELF-CONTAINED AIR-COOLED
W SELF-CONTAINED WATER-COOLE
D
N REMOTE AIR-COOLED
C CVD REMOTE AIR-COOLED
9 REMOTE
AIR-COOLED
CONDENSER TYPE
ICE MACHINE
SERIES
SV3106
CVD 0675 3
CONDENSING
UNIT MODEL
3 PHAS
E
CONDENSING
UNIT SERIES
SV3107
SV3105
General Information Section 1
1-2
Part Number 000001528
Accessories
Contact your Manitowoc distributor for these optional accessories:
CVD1476 WATER COOLED CONDENSING UNIT
(With High Pressure Water Regulating Valve)
A special order condensing unit is available that allows
condenser water inlet pressure up to 350 psig
(2413 kPA).
BIN CASTER
Replaces standard legs.
ICE BAGGER
Maximize profits from bagged ice sales with this
convenient accessory. This sturdy unit rests on the bin
door frame, and adapts for left or right side filling.
ICE DEFLECTOR
Q1400C ice machines mounted on an ice dispenser do
not require an ice deflector.
Q1400C ice machines mounted on an ice storage bin
(Manitowoc or non-Manitowoc) require the use of an ice
deflector.
Two Q1400C ice machines can be mounted side by side
on a Manitowoc 60” F & B Style bin.
Contact your sales representative or the factory sales
department to determine the proper kit for bin
applications.
WATER FILTER SYSTEM
Engineered specifically for Manitowoc ice machines,
This water filter is an efficient, dependable, and
affordable method of inhibiting scale formation, filtering
sediment, and removing chlorine taste and odor.
MANITOWOC CLEANER AND SANITIZER
Manitowoc Ice Machine Cleaner and Sanitizer are
available in convenient 16 oz. (473 ml) and 1 gal (3.78 l)
bottles. These are the only cleaner and sanitizer
approved for use with Manitowoc products.
DISPENSER
A counter-top dispenser is ideal for cafeterias and many
types of self-service facilities. Manitowoc auto-fill, floor-
standing ice dispensers meet the strict sanitary
requirements of the food service, lodging and health
care industries.
AUCS® AUTOMATIC CLEANING SYSTEM
This accessory reduces equipment cleaning expense.
The AuCS® accessory monitors ice making cycles and
initiates cleaning procedures automatically.
GSI200
This accessory releases chlorine dioxide on a controlled
basis to inhibit the growth of bacteria and slime.
!
Warning
Manitowoc Q1400C ice machines require the ice
storage bin to incorporate an ice deflector.
The deflector kit is not included with the ice machine
and must be ordered separately.
Prior to using a non-Manitowoc ice storage system
with Manitowoc ice machines, contact the
manufacturer to assure their ice deflector is
compatible with Manitowoc ice machines.
Cleaner Part Number Sanitizer Part Number
16 oz. 94-0456-3 16 oz. 94-0565-3
1 Gallon 94-0580-3 1 Gallon 94-0581-3
Section 1 General Information
Part Number 000001528 1-3
Model/Serial Number Location
Record the model and serial number of your ice machine
and bin or dispenser in the space provided below.
These numbers are required when requesting
information from your local Manitowoc distributor,
service representative, or Manitowoc Ice, Inc.
Condensing Unit
Q1400C
The model and serial number are listed on the OWNER
WARRANTY REGISTRATION CARD. They are also
listed on the MODEL/SERIAL NUMBER DECAL affixed
to the ice machine head section and condensing unit.
Both model/serial numbers must be referenced to obtain
warranty or service information.
Back of Ice Machine
CVD1476 Condensing Unit
Model/Serial Number Location
SV1746
MODEL / SERIAL NUMBERS DECAL
(CVD CONDENSING UNIT)
MODEL / SERIAL
NUMBERS DECAL
(RIGHT SIDE OF
ICE MACHINE
ELECTRICAL
CONTROL BOX)
SV1770A
SV1768A
MODEL /
SERIAL
NUMBERS
DECAL
(ICE
MACHINE)
MODEL /
SERIAL
NUMBERS
DECAL
(BIN)
SV3077
MODEL / SERIAL
NUMBERS DECAL
(CVD CONDENSING
UNIT)
Ice Machine Bin or Dispenser CVD Condensing Unit AuCS Accessory
Model Number
Serial Number
General Information Section 1
1-4
Part Number 000001528
Owner Warranty Registration Card
GENERAL
The packet containing this manual also includes
warranty information. Warranty coverage begins the day
the ice machine is installed.
If the OWNER WARRANTY REGISTRATION CARD is
not returned, Manitowoc will use the date of sale to the
Manitowoc Distributor as the first day of warranty
coverage for your new ice machine.
Warranty Coverage
GENERAL
The following Warranty outline is provided for your
convenience. For a detailed explanation, read the
warranty bond shipped with each product.
Contact your local Manitowoc Distributor or Manitowoc
Ice, Inc. if you need further warranty information.
PARTS
1. Manitowoc warrants the ice machine against defects
in materials and workmanship, under normal use
and service for three (3) years from the date of
original installation.
2. The evaporator and compressor are covered by an
additional two (2) year (five years total) warranty
beginning on the date of the original installation.
LABOR
1. Labor required to repair or replace defective
components is covered for three (3) years from the
date of original installation.
2. The evaporator is covered by an additional two (2)
year (five years total) labor warranty beginning on
the date of the original installation.
EXCLUSIONS
The following items are not included in the ice machine’s
warranty coverage:
1. Normal maintenance, adjustments and cleaning as
outlined in this manual.
2. Repairs due to unauthorized modifications to the ice
machine or use of non-standard parts without prior
written approval from Manitowoc Ice, Inc.
3. Damage caused by improper installation of the ice
machine, electrical supply, water supply or drainage,
or damage caused by floods, storms, or other acts of
God.
4. Premium labor rates due to holidays, overtime,
etc.; travel time; flat rate service call charges;
mileage and miscellaneous tools and material
charges not listed on the payment schedule.
Additional labor charges resulting from the
inaccessibility of equipment are also excluded.
5. Parts or assemblies subjected to misuse, abuse,
neglect or accidents.
6. Damage or problems caused by installation,
cleaning and/or maintenance procedures
inconsistent with the technical instructions provided
in this manual.
7. This product is intended exclusively for commercial
application. No warranty is extended for personal,
family, or household purposes.
AUTHORIZED WARRANTY SERVICE
To comply with the provisions of the warranty, a
refrigeration service company qualified and authorized
by a Manitowoc distributor, or a Contracted Service
Representative must perform the warranty repair.
NOTE: If the dealer you purchased the ice machine from
is not authorized to perform warranty service; contact
your Manitowoc distributor or Manitowoc Ice, Inc. for the
name of the nearest authorized service representative.
SERVICE CALLS
Normal maintenance, adjustments and cleaning as
outlined in this manual are not covered by the warranty.
If you have followed the procedures listed in this manual,
and the ice machine still does not perform properly, call
your Local Distributor or the Service Department at
Manitowoc Ice, Inc.
Important
Complete and mail the OWNER WARRANTY
REGISTRATION CARD as soon as possible to
validate the installation date.
Important
This product is intended exclusively for commercial
application. No warranty is extended for personal,
family, or household purposes.
Part Number 000001528 2-1
Section 2
Installation Instructions
General
These instructions are provided to assist the qualified
installer. Check your local Yellow Pages for the name of
the nearest Manitowoc distributor, or call Manitowoc Ice,
Inc. for information regarding installation and start-up
services.
Ice Machine Installation Options
CVD1476 CONDENSER WATER PRESSURE
Water pressure at the condenser cannot exceed 150
psig (1034 kPA) with the standard water-regulating
valve. Contact your distributor if your water pressure is
greater than 150 psig (1034 kPA). A special order
condensing unit is available that allows water pressure
up to 350 psig (2413 kPA).
Q1400C HEAD SECTION
The ice machine head can be installed with the electrical
inlet, water supply inlet and refrigeration tubing entering
from the back or top of the ice machine.
The ice machine water drain must exit the back of the
ice machine.
Cut the top cover for top routing of electrical inlet, water
supply inlet or refrigeration lines.
1. Prior to cutting, mount top cover onto ice machine.
2. Locate the area that will need to be cut and mark the
top cover.
3. Using a tin snips, cut top cover as needed:
A. Do not cut out entire area! Cut up to 1/8 inch to
marked line.
B. Cut out only what is needed. (If routing only
refrigeration lines out the top, cut just enough to
route these lines.)
Do not cut out the entire corner area.
Important
Failure to follow these installation guidelines may
affect warranty coverage.
TUBING CAN BE
ROUTED OUT TOP
SV1769A
TUBING CAN BE
ROUTED OUT
BACK OF THE ICE
MACHINE WITH
PROVIDED 90
°
ELL’S
TRIM TOP COVER
IN THIS AREA
SV1768B
Installation Instructions Section 2
2-2
Part Number 000001528
Ice Machine Dimensions
Q1400C ICE MACHINES
Condensing Unit Dimensions
CVD1475
Air-Cooled
SV1766
30”
(76.2 cm)
24.5”
(62.23 cm)
24”
(60.96 cm)
21.5”
(54.6 cm)
2.02”
(5.13 cm)
20.96”
(53.24 cm)
14.77”
(37.52 cm)
5.37”
(13.64 cm)
6.87”
(17.45 cm)
3.24”
(8.23 cm)
SV1758
10.75”
(27.3 CM)
14.5”
(36.8 CM)
9.5”
(24.1 CM)
FRONT VIEW
14.5”
(36.8 CM)
25.75”
(65.4 CM)
34”
(86.4 CM)
24.13”
(53.7 CM)
SV3076
21.87”
(55.5 CM)
24.53”
(62.3 CM)
20.64”
(52.4 CM)
4.26”
(10.8 CM)
8.70”
(22.1 CM)
8.54”
(21.6 CM)
12.6”
(32 CM)
CVD1476
Water-Cooled
Important
Failure to follow these installation guidelines may
affect warranty coverage.
Section 2 Installation Instructions
Part Number 000001528 2-3
Ice Storage Bin Dimensions
S970 ICE STORAGE BIN
Large Capacity Ice Storage Bin Dimensions
30 INCH (76 CM)
48 INCH (122 CM) & 60 INCH (152 CM)
!
Warning
All Manitowoc ice machines require the ice storage
system (bin, dispenser, etc.) to incorporate an ice
deflector.
The Manitowoc Q1400C ice machines require
adding Manitowoc Ice Deflector Kit when installing
with non-Manitowoc ice storage systems or 60”
Manitowoc F & B style bins.
Prior to using a non-Manitowoc ice storage system
with other Manitowoc ice machines, contact the
manufacturer to assure their ice deflector is
compatible with Manitowoc ice machines.
!
Caution
30” large capacity ice storage bins must be
attached to the wall with the bracket provided with
the bin.
SV1610
Bin Model Dimension A (Width)
Dimension B
(Height)
B750 30 in. (76.2 cm.) 58 in. (147.3 cm.)
B1050 30 in. (76.2 cm.) 78 in. (198.1 cm.)
The bin drain is exactly in the center of the bin.
Bin Model
Dimension A
(Width)
Dimension B
(Height)
B1100 48 in. (121.9 cm.) 55.0 in. (139.7 cm.)
B1400 60 in. (152.4 cm.) 55.0 in. (139.7 cm.)
The bin drain is exactly in the center of the bin.
34” (86.4 cm)
25.25”
(64.1 cm)
6”
(15.2 cm)
A
B
43.6”
(110.81 cm)
A
34” (86.4 cm)
25.25”
(64.1 cm)
6”
(15.2 cm)
B
43.6”
(110.81 cm)
Installation Instructions Section 2
2-4
Part Number 000001528
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must not obstruct airflow through or
around the ice machine. Refer to the chart below for
clearance requirements.
Ice Machine Head Section Clearance
Requirements
Q1400C:
Top/Sides 5” (127 mm) is recommended for efficient
operation and servicing. There is no minimum clearance
required.
Back 1” (25.4 mm) required when routing electrical inlet,
water inlet and refrigeration tubing out of the top of the
unit.
5” (127 mm) required when routing all connections out
the back.
Stacking Two Ice Machines on a Single
Storage Bin
Q1400C:
Q1400C ice machines cannot be stacked. However an
adapter is available that allows two Q1400C ice
machines to be placed side by side on 60” Manitowoc
F & B style bins.
Location of CVD Condensing Unit
The location selected for the CVD Condensing Unit must
meet the following criteria. If any of these criteria are not
met, select another location.
CVD1475 - The air temperature must be at least -
20°F (-28.9°C) but must not exceed 130°F (54.4°C).
CVD1476 - The air temperature must be at least
50°F (10°C) but must not exceed 110°F (43°C).
The location must not allow exhaust fan heat and/or
grease to enter the condenser.
The location must not obstruct airflow through or
around the condensing unit. Refer to the chart below
for clearance requirements.
Condensing Unit Clearance Requirements
Top/Sides
There is no minimum clearance required, although 6”
(152 mm) is recommended for efficient operation and
servicing only.,
Front/Back
48” (122 cm)
CVD1476 ONLY
Top - 5” (127 mm) is recommended for efficient
operation and servicing only.
Front/Back/Sides - 12” (305 mm)
Condensing Unit Heat of Rejection
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing
air conditioning equipment where self-contained air-
cooled ice machines are installed.
This information is also necessary when evaluating the
benefits of using water-cooled or CVD® Condensing
Units to reduce air conditioning loads. The amount of
heat added to an air-conditioned environment by a
QuietQube® ice machine head section is negligible.
!
Caution
The ice machine head section must be protected if it
will be subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
“Removal from Service/Winterization”.
Series
Condensing Unit
Heat of Rejection*
B.T.U./Hour
Air Conditioning**
Because the heat of rejection varies during the ice making cycle,
the figure shown is an average.
Peak
CVD1475
24,000 35,500
CVD1476
Section 2 Installation Instructions
Part Number 000001528 2-5
Leveling the Ice Storage Bin
1. Screw the leveling legs onto the bottom of the bin.
2. Screw the foot of each leg in as far as possible.
3. Move the bin into its final position.
4. Level the bin to assure that the bin door closes and
seals properly. Use a level on top of the bin. Turn
each foot as necessary to level the bin.
NOTE: An optional caster assembly is available for use
in place of the legs. Installation instructions are supplied
with the casters.
Leveling Leg and Foot
Air-Cooled Baffle
The air-cooled baffle prevents condenser air from
recirculating. To install:
1. Remove the back panel screws next to the
condenser.
2. Align the mounting holes in the air baffle with the
screw holes and reinstall the screws.
Air Baffle
!
Caution
The legs must be screwed in tightly to prevent them
from bending.
SV1606
THREAD LEVELING
LEG INTO BASE OF
CABINET
THREAD ‘FOOT’ IN AS
FAR AS POSSIBLE
SV1607
AIR
BAFFLE
SCREWS
Installation Instructions Section 2
2-6
Part Number 000001528
Electrical Service
GENERAL
VOLTAGE
For both the Ice Machine Head Section and the CVD®
Condensing Unit, the maximum allowable voltage
variation is ±10% of the rated voltage at ice machine
start-up (when the electrical load is highest).
FUSE/CIRCUIT BREAKER
The ice machine head section and condensing unit are
wired independently from each other.
Ice Machine Head Section
The ice machine head section does not require a
dedicated circuit breaker.
CVD® Condensing Unit
A separate fuse/circuit breaker must be provided for
each condensing unit. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the
wire size of the electrical supply. (Minimum circuit
ampacity is not the ice machine’s running amp load.)
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
GROUND FAULT CIRCUIT INTERUPTER
Ground Fault Circuit Interupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power,
presumably to ground. Manitowoc Ice, Inc. does not
recommend the use of a GFCI/GFI circuit protection with
our equipment. If code requires the use of a GFCI/GFI
then you must follow the local code. The circuit must be
dedicated, sized properly and there must be a panel
GFCI/GFI breaker. We do not recommend GFCI/GFI
outlets as they are known for more intermittent nuisance
trips than panel breakers.
!
Warning
All wiring must conform to local, state and national
codes.
!
Warning
The ice machine and condensing unit must be
grounded in accordance with national and local
electrical codes.
Section 2 Installation Instructions
Part Number 000001528 2-7
Electrical Requirements
QuietQube® Ice Machine Head Section
CVD® Condensing Unit
Ice Machine
Voltage
Phase
Cycle
Maximum Fuse/
Circuit Breaker
Total Amps
Q1400C
115/1/60
208-230/1/60
230/1/50
15 amp
15 amp
15 amp
1.1
0.6
0.6
Important
The QuietQube® Ice Machine Head Section and
CVD Condensing Unit are wired independently from
each other.
Condensing Unit
Voltage Phase
Cycle
Maximum Fuse/Circuit
Breaker
Minimum Circuit Amps
CVD1475
208-230/1/60
35 19.6
208-230/3/60
25 14.1
230/1/50 35 19.8
CVD1476
208-230/1/60 30 15.3
208-230/3/60 20 10.8
Installation Instructions Section 2
2-8
Part Number 000001528
QuietQube® Ice Machine Head Section Electrical Wiring Connections
QUIETQUBE® ICE MACHINE HEAD SECTION
115/1/60
QUIETQUBE® ICE MACHINE HEAD SECTION
230/1/50
!
Warning
These diagrams are not intended to show proper
wire routing, wire sizing, disconnects, etc., only the
correct wire connections.
All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes.
Though wire nuts are shown in the drawings, the ice
machine field wiring connections may use either
wire nuts or screw terminals.
L
1
L
1
N=115V
OR
L2=208-230V
GROUND
GROUND
ICE MACHINE
CONNECTIONS
SV1258
L
1
L
1
N
N
GROUND
GROUND
ICE MACHINE
CONNECTIONS
TO SEPARATE
FUSE/BREAKER.
DISCONNECT ALL
POLES.
SV1191
For United Kingdom Only
As the colours of the wires in the mains lead of the appliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
The wire which is coloured green and yellow
must be connected to the terminal in the plug which is marked with
the letter E or by the earth ground symbol or coloured green or green and yellow.
The wire coloured blue
must be connected to the terminal which is marked with the letter N or coloured black.
The wire coloured brown
must be connected to the terminal which is marked with the letter L or coloured red.
Section 2 Installation Instructions
Part Number 000001528 2-9
Remote Electrical Wiring Connections
CVD CONDENSING UNIT
208-230/1/60
CVD CONDENSING UNIT
208-230/3/60
CVD CONDENSING UNIT
230/1/50 (CVD1475 ONLY)
!
Warning
These diagrams are not intended to show proper
wire routing, wire sizing, disconnects, etc., only the
correct wire connections.
All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes.
Though wire nuts are shown in the drawings, the ice
machine field wiring connections may use either
wire nuts or screw terminals.
L
1
L
1
L2
GROUND
GROUND
CONDENSING UNIT
CONNECTIONS
TO SEPARATE
FUSE/BREAKER
SV1258
L
1
L
1
GROUND
GROUND
CONDENSING
UNIT
CONNECTIONS
TO SEPARATE
FUSE/BREAKER
L
2
L
3
L
2
L
3
SV1190
L
1
L
1
N
N
GROUND
GROUND
CONDENSING UNIT
CONNECTIONS
TO SEPARATE
FUSE/BREAKER.
DISCONNECT ALL
POLES.
SV1191
Installation Instructions Section 2
2-10
Part Number 000001528
Ice Machine Head Section Water Supply
and Drains
POTABLE WATER SUPPLY
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
POTABLE WATER INLET LINES
Follow these guidelines to install water inlet lines:
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
If water pressure exceeds the maximum
recommended pressure, obtain a water pressure
regulator from your Manitowoc distributor.
Float Valve - 80 psig (551.5 kPA)
Install a water shut-off valve for ice making potable
water.
Insulate water inlet lines to prevent condensation.
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:
Drain lines must have a 1.5 inch drop per 5 feet of
run (2.5 cm per meter), and must not create traps.
The floor drain must be large enough to
accommodate drainage from all drains.
Run separate bin and ice machine drain lines.
Insulate them to prevent condensation.
Vent the bin and ice machine drain to the
atmosphere. The ice machine drain requires an 18”
vent.
Water Cooled Condenser Water Supply and
Drains
CONDENSER WATER SUPPLY
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
WATER COOLED CONDENSER LINES
Follow these guidelines to install water lines:
Contact your distributor if your water pressure is
greater than 150 psig (1034 kPA). A special order
condensing unit is available that allows water
pressure up to 350 psig (2413 kPA).
Install a shutoff valve (inlet and outlet on cooling
tower or closed loop circuits) to allow isolation of the
water system.
Water entering the condenser must not exceed 90°F
(32.2°C).
Water flow through the condenser must not exceed 5
gallons (19 liters) per minute.
Allow for a pressure drop of 8 psig (55 kPA) between
the condenser water inlet and outlet.
Water exiting the condenser must no exceed 110°F
(43.3°C).
CONDENSING UNIT DRAIN CONNECTIONS
The condensing unit drain is provided to remove any
condensate produced by the suction accumulator.
Condensate amounts will vary depending on
temperature and humidity.
The condensing unit must be level front to back and
side to side to allow the condensate to drain.
Drain lines must have a 1.5-inch drop per 5 feet of
run (2.5 cm per meter), and must not create traps.
Drain termination must meet applicable costs.
Important
If you are installing a Manitowoc water filter system,
refer to the Installation Instructions supplied with the
filter system for ice making water inlet connections.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Manitowoc CVD1375 User manual

Category
Ice cube makers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI