14
V 01/18
High Ventilation: for the first 30 minutes the medium and high ventilation alternate every 10 seconds, for the
following 30 minutes the unit works at a medium ventilation, after one hour the unit works at low ventilation
until switching off.
Medium Ventilation: For the first 30 minutes the medium and low ventilation alternate every 10 seconds,
following that the unit keeps working at a low ventilation speed until switching off.
Low Ventilation: For the first 10 seconds the unit works at a low ventilation, for the following 5 seconds the
unit stops the ventilation and then resumes ventilation alternating 10 seconds of low ventilation and 5
seconds interrupting it until switching off.
- Nature mode: the unit works according to the following description according to the selected speed:
High Ventilation: The ventilation sequence is as follows: High ventilation for 5 sec. Low ventilation for 5
sec. Medium ventilation for 5 sec. Ventilation switched off for 5 sec. Medium ventilation for 10 sec.
High ventilation for 10 sec. Medium ventilation for 5 sec. Low ventilation for 5 sec. Ventilation
switched off for 5 sec. Medium ventilation for 5 sec. High ventilation for 5 sec. Low ventilation for 5
sec. Ventilation switched off for 5 sec. The unit works this way until it is turned off.
Medium Ventilation: The ventilation sequence is as follows: Medium ventilation for 5 sec. Low ventilation
for 5 sec. Medium ventilation for 5 sec. Low ventilation for 5 sec. Ventilation stops for 5 sec.
Medium ventilation for 10 sec. Low ventilation for 10 sec. Medium ventilation for 5 sec. Low
ventilation for 5 sec. Ventilation off for 5 sec. Medium ventilation for 5 sec. Low ventilation for 5 sec.
Ventilation off for 5 seconds. The unit operates in this mode until it is turned off.
Low Ventilation: The ventilation sequence is as follows: Medium ventilation for 5 sec. Low ventilation for
15 sec. Medium ventilation for 5 sec. Low ventilation for 15 sec. Ventilation stopped for 5 seconds,
Medium ventilation for 5 sec. Low ventilation for 10 sec. Medium ventilation for 5 sec. Low ventilation
for 10 sec. Ventilation off for 5 sec. Medium ventilation for 5 sec. Low ventilation for 20 sec.
Ventilation switched off for 5 sec. The unit works this way until it is turned off.
3. SPEED BUTTON
In power state, press the SPEED button to switch among low medium and high level.
4. COOL AIR BUTTON
Press this button to turn on or turn off the "Cooler/Humidifier" mode: the correspondent LED lights up.
5. TIMER BUTTON
When the button is first pressed, the timer sets to 1/2 hour; the time increases by 30 minutes when the button is pressed
every time, and the timer can be set up to 7.5 hours; if the button is pressed again, and the timer turns off; press the
button again to repeat the cycle.
6. ION BUTTON
Push this button to turn on and off the ION function. The correspondent LED will turn on.
HOW TO INSERT / REMOVE THE REMOTE CONTROL BATTERIES
Open the battery cover on the back of the remote control. Place the battery inside the cover, making sure the polarity is
correct. Slot the cover back into position on the remote control. Use Lithium/Manganese button cells, model no. CR2032 -3V,
compliant with Battery Directive no. 2006/66/EC (supplied with the remote control).
INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE
2006/66/EC
Please replace the battery when its electrical charge has been exhausted: at the end of its useful life, it must not be disposed of
together with unsorted waste. It must be must be delivered to appropriate separated waste disposal plants or to dealers that
provide a similar service. Separate waste disposal of batteries prevents potential negative effects on the environment and human
health resulting from inadequate disposal, and also allows the materials from which it is made to be recovered and recycled in
order to achieve significant savings in terms of energy and resources. The separate disposal obligation is underlined by the
crossed-out dustbin symbol appearing on the battery. Illegal disposal of the product by the user shall result in the application of
administrative sanctions as defined by current regulations.