ENGLISH USERS MANUAL SOLADIN 600
Product description and application
Congratulations for choosing the Mastervolt Soladin
600. The Soladin 600, further mentioned as
“Soladin”, is a grid connected solar inverter, used for
the conversion and feed back into the utility grid of
the power generated by photovoltaic modules.
The Soladin is equipped with extensive safety
measures to ensure that it switches off immediately
as soon as the AC plug is removed from the wall
socket or the public grid fails in operation
The Soladin is only suitable for the feed back of
solar power into the public grid, not as a stand-alone
inverter.
Unpacking
The delivery consists of the following parts:
• The Soladin with mounting bracket
• This user’s manual
After unpacking, check the Soladin for possible
damage. Do not use the Soladin if it is damaged. If
in doubt, contact your supplier.
Safety
• Install the Soladin according to the instructions
stated in this manual.
• Be sure that the Soladin is disconnected from the
grid during installation. This can be done by
removing the AC-plug from the wall socket.
• Connections and safety features must be
executed according to the locally applicable
regulations
• The Soladin must be used in accordance with the
specifications as stated on page 30
• Never open the housing as high voltages may be
present inside!
PV modules and strings
A solar system consists of several photovoltaic
(solar) modules, further mentioned as “PV
modules”. The PV-modules are connected in series
to form a so called “string”. These strings consist of
a positive (+) and a negative (–) connection which
can be connected directly to the Soladin. The
voltages present on these strings are not safe to
touch and cannot be switched off
Therefore the solar system should meet the
following specifications:
• Maximum open circuit string voltage at lowest
possible temperature of the PV modules: 155
VDC. See table 3 for typical configurations for the
Soladin.
• Double isolated PV-wiring
• All cables of the string should have double
isolation and must be fitted with pre-assembled
MultiContact connectors (Ø4mm). Consult an
installer for the availability of such cable
assemblies. Do not assemble these yourself!
• Depending on local applicable regulations the
use of additional DC switch may be mandatory
Contact an installer if the solar-system does not
comply with the above mentioned stipulations. Due
to possible high voltages installation and
modification may only be carried out by a qualified
electrician who is familiar applicable regulations and
standards.
Things you need to install the Soladin
Make sure you have all the parts you need to install
the Soladin:
• The Soladin (included)
• Two screws (with plugs) to mount the Soladin.
Maximum diameter: 4.5 mm. Use mounting
materials which are suitable to carry the weight of
the Soladin.
• Tools to fix the screws / bolts with plugs into the
wall (screwdriver, drilling machine, a set of drills,
a pencil)