For the latest User Installation Guide please visit: www.ergotron.com
User's Guide
888-45-207-W-02 rev.K • 10/14
2 of 23
2
1
1-4 lbs
(0.45-1.8 kg)
6-18 lbs*
(2.7-8.2 kg)
90˚ -10˚
180˚
360˚
20"
(508mm)
5"
(127mm)
25˚
< 50 lbs (22.7 kg)
1.38" - 3.75"
(35-95 mm)
10mm
11 mm
13 mm
7/16"
11mm 1/4"
> 3"
1/4”
Ø 3/8" (10 mm) Ø 1/2" (12.8 mm)
Ø 7/32" (5.6 mm)
ENGLISH
* The Combo Arm can be modi ed to mount displays up to 25 lbs (11.3
kg), however display lift and tilt motion will not be possible if this option
is chosen. Refer to special instructions on page 14.
Important! You will need to adjust this product after installation is complete. Make sure all your equipment is properly
installed on the product before attempting adjustments. This product should move smoothly and easily through the
full range of motion and stay where you set it. If movements are too easy or dif cult or if product does not stay in
desired positions, follow the adjustment instructions to create smooth and easy movements. Depending on your
product and the adjustment, it may take many turns to notice a difference. Any time equipment is added or removed
from this product, resulting in a change in the weight of the mounted load, you should repeat these adjustment steps
to ensure safe and optimum operation.
Tools Needed
Concrete Wall Mounting
HOLLOW WALL
Stud Finder
888-45-207-W-02 rev.K • 10/14
3 of 23
AB C D E
1
2
3
4
5
6
7
8
9
1x
1x
1x
1x
1x
1x
1x
1x
4x
3x
2x
1x
M4 x 10mm
4x
M4 x 10mm
4x
2x
M6 x 10mm
2x
8x
M6 x 70mm M4.2 x 25mm
10x 4x
10x
10x
6 mm
3 mm
10x
M6
2x
2x
2x
4x
1/4-20 x 2"
10x
7x
5x
4x
1x
1x
1x
1x
1x
1x
1x
M8 x 16mm
8x
1x
M4 x 8mm
2x
M4 x 6mm
1x
4x
M10 x 18mm
2x
M10 x 16mm
1x
1x
M3.5 x 8mm
2x
M5 x 15mm
2x
1x
8mm
ENGLISH
Components
Optional Weight Capacity Modi cation Fasteners
Flat Head Pan Head
888-45-207-W-02 rev.K • 10/14
4 of 23
1
6”
(152 mm)
21”
(533 mm)
32.5”
(826mm)
< 31.5”
(800mm)
5’3”-5’9”
(160-175cm)
12.3”
(311mm)
8.1”
(206mm)
8.9”
(226mm)
9.4”
(238mm)
18.8”
(478mm)
28”
(712mm)
16.8”
(425mm)
ENGLISH
Mounting Height for Ergonomic Workstation
This mounting height is a recommendation for an ergonomic workstation that accommodates user heights of 5’3”-5’9” (160-
175cm).
If user heights are di erent than this, you should change mounting height to accommodate user heights. (Change mounting
height one inch for every one inch di erence in user heights).
Mounting height assumes there is a 6” (152 mm)
distance between the center of your monitor
mounting holes and the top of the screen. If your
distance is smaller, you should increase mounting
height accordingly, if your distance is larger, you
should decrease your mounting height accordingly.
Determine mounting location:
Top view showing range of motion when pulled out from the wall.
Front view with arm pushed back against the wall.
888-45-207-W-02 rev.K • 10/14
5 of 23
2
6
8
10x 10x
10x
10x
Ø 3/8" (10 mm) Ø 1/2"
1/4-20 x 2"
10x
M6
≤ 16"
Studs ≥ 25
gauge steel
≥ 5/8"
Sheetrock
Stud spacing
ENGLISH
Concrete Wall Mounting
HOLLOW WALL
WARNING: Because surfaces vary widely and the ultimate mounting method is out of Ergotron’s control, it is imperative that you consult with
appropriate engineering, architectural or construction professional to ensure that your Ergotron mounting solution is mounted properly to handle applied loads.
888-45-207-W-02 rev.K • 10/14
6 of 23
2
a
b
c
3-1/8"
(80 mm)
x 10
x 10
ENGLISH
Concrete Wall Mounting
WARNING:
Mounting holes must be at least 3-1/8” (80mm) deep and must be located within solid
concrete, not mortar or covering material. If you drill into an area of concrete that is
not solid, reposition mounting holes until both anchors can be fully inserted into solid
concrete!
WARNING:
Anchors that are not fully set in solid concrete will not support the applied load
resulting in an unstable, unsafe condition which could lead to personal injury
and/or property damage. Consult a construction professional if you have any
doubt about what this means in regard to your particular situation.
888-45-207-W-02 rev.K • 10/14
7 of 23
10x
123
10x
M6 x 70mm
10mm
10mm
10x
M6
10
3
d
e
ENGLISH
CAUTION: Make sure the wall mount bracket is level,
ush and snug to the wall surface. DO NOT OVERTIGHT-
EN THE BOLTS.
888-45-207-W-02 rev.K • 10/14
8 of 23
2
acb
10x
≤ 16"
Studs ≥ 25
gauge steel
≥ 5/8"
Sheetrock
Stud spacing
ENGLISH
HOLLOW WALL
Requires minimum material thickness of 5/8” (16 mm).
888-45-207-W-02 rev.K • 10/14
9 of 23
10
3
d
e
1234
10x
10x
1/4-20 x 2"
2
ENGLISH
HOLLOW WALL
CAUTION: Make sure the wall mount bracket is level,
ush and snug to the wall surface. DO NOT OVERTIGHT-
EN THE BOLTS.
888-45-207-W-02 rev.K • 10/14
10 of 23
3a
c d
b
M6 x 10mm
6 mm
3 mm
4x
M10 x 18mm
¼"
ENGLISH
NOTE: Fasteners may unwind due to vibration caused by move-
ment of mounting solution over time. Inspect mounting solution
for loose fasteners on a routine basis. If desired, apply a light duty
thread locking adhesive to fasteners before installation to prevent
back-out.
888-45-207-W-02 rev.K • 10/14
11 of 23
4a
6 mm
12x
2x
g
i
h
e f
b c d
M6 x 10mm
3 mm
2x M10 x 16mm
ENGLISH
888-45-207-W-02 rev.K • 10/14
12 of 23
5
6
13 mm
1x
1x
1x
1x
1x
M8 x 16mm
2x M5 x 15mm
3 mm
ENGLISH
888-45-207-W-02 rev.K • 10/14
13 of 23
g
7a
b
h
i
f
c
d
e
4x
ENGLISH
888-45-207-W-02 rev.K • 10/14
14 of 23
2x M4 x 6mm
1x
M4 x 8mm
1x
1x
20˚
a
a c
b
b
i
ii
ENGLISH
Optional Weight Capacity Modi cation for Displays 18 - 25 lbs (8.2 - 11.3 kg) Only!
IMPORTANT: with this option display lift and tilt motion are no longer possible. To accomodate extra weight, the display is  xed at one of three heights (spaced
2.5" (64 mm) apart), and display tilt is  xed at 20°. If mounting a display 18 lbs (8.2 kg) or less, skip to next page.
Flat Head
Pan Head
Optional Weight Capacity Modi cation
888-45-207-W-02 rev.K • 10/14
15 of 23
8
100mm
75mm
4x 4x
M4 x 10mm
9
1x
M3.5 x 8mm
ENGLISH
888-45-207-W-02 rev.K • 10/14
16 of 23
10
edf
g
ij
h
bca
ENGLISH
NOTE: Leave enough slack in cable to allow full range of motion.
Caution:
To avoid the potential to pinch cables it is important to follow the cable routing instructions in this manual. Failure to
follow these instructions may result in equipment damage or personal injury.
888-45-207-W-02 rev.K • 10/14
17 of 23
m
k
l
7x
5x
2x
12
2x
12
11
ENGLISH
NOTE: Make sure cables can slide in and out through
covers and cable channels.
888-45-207-W-02 rev.K • 10/14
18 of 23
13
a
f
cd
ghe
b
M4.2 x 25mm M4.2 x 25mm
M4.2 x 25mm
4x 2x 2x 2x
2x
Ø 7/32" (xx mm)
.21875
Flush with drywal
12 3
4x
2x
1x 1x
2x 2x 2x
ENGLISH
CAUTION: Make sure there is enough clearance between back of mounted component and cable
channel. Failure to allow clearance space may result in personal injury and equipment damage.
888-45-207-W-02 rev.K • 10/14
19 of 23
ik
14 ab
c
d
15 2x
ENGLISH
888-45-207-W-02 rev.K • 10/14
20 of 23
16
a
1/4”
8mm
ENGLISH
Increase Lift Strength
If the mounted weight is too heavy or
this product does not stay up when
raised, then you'll need to increase
Lift Strength:
Decrease Lift Strength
If the mounted weight is too light or
this product does not stay down when
lowered, then you'll need to decrease
Lift Strength:
Lift – Up and down
Adjustment Step
Important! You will need to adjust this product after installation is complete. Make sure all your equipment is
properly installed on the product before attempting adjustments. This product should move smoothly and easily
through the full range of motion and stay where you set it. If movements are too easy or dif cult or if product
does not stay in desired positions, follow the adjustment instructions to create smooth and easy movements.
Depending on your product and the adjustment, it may take many turns to notice a difference. Any time
equipment is added or removed from this product, resulting in a change in the weight of the mounted load, you
should repeat these adjustment steps to ensure safe and optimum operation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Ergotron 45-273-026 Owner's manual

Category
Flat panel wall mounts
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI