077Z7

Danfoss 077Z7 Installation guide

  • Hello! I've reviewed the provided Danfoss installation guide for the 077Z7 series thermostats. These thermostats have adjustable cut-in and cut-out temperatures and are designed for use with R290 and R600a refrigerants. The guide includes specifications for various models, including capillary lengths and minimum sensor requirements. I'm ready to answer your questions about these devices.
  • What refrigerants are these thermostats designed for?
    What is the operating range for these thermostats?
    Do all the thermostats have the same capillary length?
Service thermostats 077Z7010
Service thermostats 077Z7012
Service thermostats 077Z7011
Service thermostats 077Z7013
Length of capillary (in): L = 39
(airsensor)
Length of capillary (in): L = 42
Min. sensor length mounted on evaporator (in):
LS = 4
(Used as airsensor min. 2 x LS)
Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in):
LS = 6
(Used as airsensor min. 2 x LS)
Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in):
LS = 6
(Used as airsensor min. 2 x LS)
16 – 96 A
EBD
3 4
16 – 96 A
EBD
3 4
Cut-in
+9
+38
+28
+19
Off Warm Middle
Setting pos.
Cold
Cut-out
°F
Cut-in
+17
+41
+29.5
+23.5
Off Warm Middle
Setting pos.
Cold
Cut-out
°F
Cut-in
+3
-14
+36
+26
+9
+21.5
Off Cold
Cut-out
°F
Warm Middle
Setting pos.
Cut-in
+3
-14
+36
+26
+9
+21.5
Off Cold
Cut-out
°F
Warm Middle
Setting pos.
16 – 96 A
EBD
3 4
16 – 96 A
EBD
3 4
Info for UK customers only: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB
Імпортер:ТОВ з іі "Данфосс ТОВ" 04080, Київ 80, п/с 168, Україна 077R0704
077R0704
Installation Guide
Service thermostats
Type 077Z7
© Danfoss | Climate Solutions | 2022.10 AN216286431722en-000103 | 1
The 077Z….EBD, 077Z….L EBD can be applied on systems with R290 and R600a as the working fluid.
Always adhere to local codes and safety guidelines. For countries with no conformity certification (UL, CE, CCC, CSA, EAC, etc.)
requirements on new systems, Danfoss recommends third party apporval for systems containing flammable refrigerants.
Note: All temperatures at 760 mm Hg
Service thermostats 077Z7014
Service thermostats 077Z7016
Service thermostats 077Z7015
Service thermostats 077Z7017
Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in): LS = 5
(Used as airsensor min. 2 x LS)
Length of capillary (in): L = 42
Min. sensor length mounted on evaporator (in):
LS = 4
(Used as airsensor min. 2 x LS)
Length of capillary (in): L = 66
Min. sensor length mounted on evaporator (in):
LS = 4
(Used as airsensor min. 2 x LS)
Cut-in
+25.5
+10
+47
+36.5
+25
+37.5
Off Cold
Cut-out
°F
Warm Middle
Setting pos.
Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in):
LS = 5
(Used as airsensor min. 2 x LS)
Cut-in
-18.5
-29
+9.5
+3
-11
-3
Off Cold
Cut-out
°F
Warm Middle
Setting pos.
16 – 96 A
EBD
3 4
16 – 96 A
EBD
36
4
16 – 96 A
EBD
3 4
16 – 96 A
EBD
3 4
Cut-in
-11
-25.5
+16.5
+7
-7.5
+4
Off
Cold
Cut-out
°F
Warm Middle
Setting pos.
Cut-in
-18.5
-29
+9.5
+3
-11
-3
Off Cold
Cut-out
°F
Warm Middle
Setting pos.
© Danfoss | Climate Solutions | 2022.10 AN216286431722en-000103 | 2
/