ATTENTION: SERVICE MANAGER - PARTS MANAGER
SERVICE BULLETIN – SB1011
DATE:
14 July 2011
TO:
VULCAN AND WOLF CONTRACTED PARTS AND SERVICE AGENCYS
HOBART BRANCHES AND AGENCYS
FROM:
Ronald Arrington
SUBJECT:
Preventive Maintenance – Convection Ovens
Model Numbers Affected
All VC and SG series convection ovens.
Problem:
The air intake perforations located in the lower left corner of the back panel assembly
may become clogged with grease or debris. This restricts both cooling and combustion
air causing possible component failure and intermittent ignition failures.
Tools
Not required.
Action
As a quarterly maintenance procedure and after each service, use a damp rag and
clean blockage from air intake.