LG LWA3BP2A Owner's manual

Type
Owner's manual

This manual is also suitable for

04-
AUTO RESTART
In failure of electric power the unit runs as previous setting operat ion when power returns.
How to Insert the Batteries
Remove the cover from the back of the remote
controller.
Slide the cover according to the arrow direction.
Insert the two batteries.
Be sure that the (+) and (-) directions are correct.
Be sure that both batteries are new.
Re-attach the cover.
Slide it back into the position.
Do not use rechargeable
batteries, such batteries differ
from standard dry cells in shape,
dimensions, and performance.
Remove the batteries from the
remote controller if the air
conditioner is not going to be
used for an extended length of
time.
FAN SPEED SELECTOR
Select the fan speed in Three steps Low (F1) / Med. (F2) / High (F3)
ROOM TEMPERATURE SETTING BUTTON
Control the room temperature within a range of 16°C to 30°C.
AUTO SWING
The vertical louver swings horizontally by the automatic system and stops when you press the
button again.
SIGNAL RECEIVER
1
2
3
4
5
6
7
Fan speed in two steps Low (F1) / High (F2) in select models.
Operation modes may vary in select models.
NOTE: SLEEP’ and ‘TIMER function cannot operate at same time.
SLEEP BUTTON
9
AIR PURIFIER (For Plasma Model)
Used to start or stop plasma purification system. Clean filter indication will be 'ON' on panel,
when filter cleaning is required.
8
Sleep function can be set by one hour for a maximum of 7 hours. In the first 30 minutes set
temperature increases by 1°C and in the next 30 minutes temperature increases by another
C, this temperature then remains till the timer function is deactivated. This is how the
sleep function behaves. The fan speed will change to low speed(F1).
ON/OFF TIMER
Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours.
In the first 30 minutes set temperature increases by C and in the next 30 minutes temperature
increases by another C, this temperature then remains till the timer function is deactivated.
3
Type 3
Type 4
-9-
Controls
The Remote Control unit will not function properly if strong light strikes the sensor
window of the air conditioner or if there are obstacles between the Remote Control
unit and the air conditioner.
Precaution:
POWER BUTTON
Operation starts, when this button is pressed and stops when you press the button again.
OPERATION MODE SELECTION BUTTON
Select (a)Cool (b)Energy Saver (c)Fan & (d)Dehumidification (dry) with this button.
Energy saver mode-fan stops when compressor stops cooling. Approximately after 3
minutes fan will turn on to determine it cooling is needed. In dry mode, unit will run at
low fan speed only with compressor ‘ON’.
1
2
Your Panel may look like any
of below mentioned panels.
22
2 3
Mode Timer
4
5
6
1
7
Fan Speed Temp
ON/OFF
Fan
Cool On
Dry Energy Saver
V
V
Type 1
Type 2
22
5
1
Temp Power
Fan
Cool
Timer
V
V
REMOTE CONTROLLER
( )
2 b
3
5
6
2
4
1
DOWN UP
POWER
FAN SPEED
TIMER COOLING/FAN
ENERGY SAVER AUTO SWING
3
5
6
2
4
1
DOWN UP
POWER
FAN SPEED
TIMER COOLING/FAN
ENERGY SAVER AUTO SWING
( )
2 b
REMOTE CONTROLLER
AUTO
SWING
FAN
SPEED
7
Mode Timer
COOL
DRY
FAN
TEMP
88
ENERGY SAVER ON
FAN
SPEED
AUTO
SWING
ON/OFF
(e)
ENERGY SAV ER
5
Temp
42
7
3 6 1
COOL
FAN
TEMP
88
ON/OFF
5
Temp
1
7
V
V
a
e
F p
d
n
S
e
e
S
l p
e
e
d
M
o
m
e
T
i
r
A
u
o
t
i
w
n
g
S
A
r
i
f
i
P
r
i e
r
u
r
P e
o
w
1
4
2
63
9
8
5
V
V
e
F
a
n
S
pe
d
p
S
e
l
e
M
o
d
e
i
T
e
m r
o
u
A
t
S in
g
w
r
w
P
o
e
1
4
2
63
9
5
5
6
2
4
1
TEMP
POWER
FAN SPEED
MODE
AUTO SWING
MODE FAN
TIMER
TEMP
1
2
3
4
5
8
Air
Purifier
(b)
FUZZY
DRY JET
ENERGY
SAVER
INDOOR DESIRED
88 88
CLEAN
FILTER
AIR
PURIFIER
CL
10
7
(a)
MODE FAN
TIMER
TEMP
ON/OFF
1
2
3
4
5
6
AUTO SWING
FUZZY
DRY JET
ENERGY
SAVER
INDOOR DESIRED
88 88
CLEAN
FILTER
AIR
PURIFIER
CL
10
7
9 9
ON/OFF
-10-
Your Panel may look like any of below mentione d panels.
OPERATION MODE SELECTION BUTTON
Select (a) Cool, (b) Energy Saver, (c) Fuzzy & (d) Dry. In dry mode, unit will run at low fan speed only
with compressor 'ON'. When compressor is 'OFF', fan will be off.
During Energy Saver mode, fan stops when compressor stops cooling. Approximately after 3 minutes
fan will turn ON to determine if cooling is needed. If cooling is not needed, the fan turns OFF again.
ON/OFF TIMER
Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours. In case of Auto
Restart, ON/OFF Timer is automatically cancelled.
Used to Start or Stop the Plasma Purification function.
FOR PLASMA MODEL-
AIR PURIFIER
AUTO RESTART
In failure of electric power the unit runs as previous setting operation when power returns.
FAN SPEED SELECTOR
Select the fan speed in Three steps Low / Med / High
ROOM TEMPERATURE SETTING BUTTON
Control the room temperature within a range of 18°C to 30°C.
AUTO SWING
The vertical louver swings horizontally by the automatic system and stops when you press the button again.
SIGNAL RECEIVER
POWER (ON/OFF) BUTTON
Operation starts, when this button is pressed and stops when you press the button again.
1
2
3
4
5
6
7
8
Fan speed in two steps Low (F1) / High (F2) in select models.
Operation modes may vary in select models.
Child Lock is used to prevent children from changing the settings of the unit. It can be activated when the
unit is ON by pressing the Fan Key (4) and the Timer Key (3) simultaneously for 5-10 seconds. When the
Child Lock is active, icon 'CL' lights upon the control panel. Now, the keys on the Control Panel and the
Remote Controller will stop working. To deactivate the Child Lock, press again the Fan Key (4) and the
Timer Key (3) simultaneously for 5-10 seconds. When Child Lock is deactivated icon 'CL' goes off on the
Display Panel.
CHILD LOCK
9
a. In case when CLEAN FILTER indication is 'ON' on the Control Panel, the Plasma Pure Filter (For select
models) needs to be cleaned. Turn 'OFF' the unit and remove Plasma Filter by opening the grill. Then
clean the filter and replace it back to it original position. After this close the grill and turn 'ON' the unit.
The CLEAN FILTER indication goes 'OFF' on the Display Panel. In case it doesn't reset the unit.
CLEAN FILTER
10
b. In case when CLEAN FILTER indication is blinking on the Control Panel, the Anti-Bacteria / Deo-Air Filter
needs to be cleaned. Turn 'OFF' the unit and remove the filter by opening the grill. Then clean the filter
and replace it back to the original position. After this close the grill and turn 'ON' the unit. Then press
the Temperature Down key (5) continuously for 5 seconds. The CLEAN FILTER indication goes 'OFF'
on the Control Panel.
FUZZY
DRY JET
ENERGY
SAVER
INDOOR DESIRED
88 88
CLEAN
FILTER
AIR
PURIFIER
CL
10
9
(c)
TIMER
FAN
SPEED
MODE
AUTO
SWING
TEMP
ON/OFF
1
5
6
4
3
7
2
-12-
The remote control transmits the signals to the system.
Features of the Remote Control- Door Closed
1
START/STOP BUTTON
Operation starts when this button is
pressed and stops when the button is
pressed again.
2
OPERATION MODE
SELECTION BUTTON
Used to select the operation mode.
ROOM TEMPERATURE
SETTING BUTTONS
Used to select the room temperature.
3
4
INDOOR FAN SPEED
SELECTOR
Used to select fan speed in four steps
Low, Medium, High, or CHAOS*.
JET COOL
Used to start or stop the speed
cooling. (Speed cooling operates
high fan speed in cooling mode).
5
AIR SWING BUTTON
Used to stop or start vertical louver
movement.
6
Operation Mode
Cooling Mode
Fuzzy Mode
Dry Mode
(Cooling Model)
- Your unit shall have either Type A,Type B, Type C or Type D Remote Control
* Available in selected models. In other models, CHAOS is same as high speed.
ON
Signal transmitter
Flip-up door
(closed)
2
4
5 1
3
6
1
3
5
4
Flip-up door
(closed)
2
Signal transmitter
ON
Signal transmitter
Flip-up door
(closed)
2
4
5 1
3
JET COOL TEMP A/SWING
FAN SPEED POWER
O L
JET C O
A/SWING
POWER
TEMP
FAN SPEED
MODE
MODE
6
1
3
5
4
Flip-up door
(closed)
2
Signal transmitter
TYPE A TYPE B TYPE C TYPE D
66
About the remote control on the system
The Remote Control unit will not function properly if strong light strikes the sensor window of the air
conditioner or if there are obstacles between the Remote Control unit and the air conditioner.
Precaution:
-13-
ON
OFF
CANCEL
SET
3
4
6
8
10
1
2
7
9
5
Flip-up door
(opened)
Signal
transmitter
Signal
transmitter
ON OFF
PLASMA
SET
CANCEL
4
5
6
7
9
1
2
3
8
Features of the Remote Control- Door Opened
1
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping
operation.
2
TIME SETTING BUTTONS
Used to adjust the time, (See page 21)
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is
obtained and to cancel the Timer operation.
(See page 21)
3
4
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
(See page 21)
FAN MODE BUTTON
Used to circulate the room air without cooling
or heating (turns indoor fan on/off).
(See page 22)
5
ROOM TEMPERATURE
CHECKING BUTTON
Used to check the room temperature.
6
PLASMA (OPTIONAL)
Used to start or stop the plasma-purification
function. (See page 18)
7
PERSONAL MODE
8
Used to run the unit in Personal Mode
(See page 19)
RESET BUTTON
9
Used prior to resetting time or after replacing
batteries.
2nd F Button (Type C or Type D
Remote Control)
10
Used prior to using modes printed in blue at
the bottom of buttons. (See page 20)
3
4
6
8
10
1
2
7
9
5
Flip-up door
(opened)
Signal
transmitter
Signal
transmitter
ON OFF
PLASMA
SET
CANCEL
4
5
6
7
9
1
2
3
8
JET COOL TEMP A/SWING
FAN SPEED POWER
TIMER SLEEP
TIMER
FAN
ROOM
MODE
RESET
PERSONAL MODE
J T COOLE
A/SWING
POWER
TEMP
FAN SPEED
MODE SLEEP CANCEL
TIMERON OFF SET
FAN ROOM
TIMER
PERSONAL MODE
-14-
To raise the temperature
To lower the temperature
Press the Start/Stop button.
The unit will respond with
a beep.
Open the door on the remote control. To select Cooling
Mode, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Close the door on the remote control. Set the temperature
higher than the room temperature. The temperature can be
set within a range of 18°C~30°C in 1°C increments.
Set the fan speed again with the door
of the remote control still closed. You
can select the fan speed in four steps-
low, medium, high or CHAOS*. Each
time the button is pressed, the fan
speed mode is shifted.
Cooling Mode
1
2
3
4
JET COOL TEMP A/SWING
FAN SPEED POWER
MODE
POWER
FAN SPEED
How to use the Operation Mode Selection button
MODE
Cooling Fuzzy Dry
* Available in selected models. In other models, CHAOS is same as high speed.
-15-
To raise the temperature
To lower the temperature
Press the Start/Stop button.
The unit will respond with
a beep.
Open the door on the remote control. To select Fuzzy
Mode, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
The temperature and fan speed are automatically set by the
electronic controls based on the actual room temperature. If
you want to change the set temperature, close the door on
the remote control and press the Room Temperature Setting
buttons. The cooler or warmer you feel, the more times (up to
two times) you should press the button. The set temperature
will be changed automatically.
During Fuzzy Mode :
You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
Fuzzy Mode
1
2
3
JET COOL TEMP A/SWING
FAN SPEED POWER
POWER
MODE
MODE
Cooling Fuzzy Dry
-16-
Press the Start/Stop button.
The unit will respond with
a beep.
Open the door on the remote control. To select Dry Mode,
press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
During Dry Mode :
Unit will run at low fan speed with compressor 'ON'. When compressor is 'OFF', fan will be 'OFF'.
Dry Mode
1
2
JET COOL TEMP A/SWING
FAN SPEED POWER
POWER
MODE
MODE
Cooling Fuzzy Dry
Set temperature cannot be changed.
-17-
or or
NOTE:
During the JET COOL function at any moment, the A/C starts to blow the cool air at
high speed for 30 minutes setting the room temp. automatically to 18°C. It is
especially used to cool the room temp. in the shortest time in a hot summer.
In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, Fan Speed button or temp. setting button
or the JET COOL button again.
Press the Start/Stop button.
The unit will respond with
a beep.
Press the Jet Cool button to operate
the speed cooling mode and the unit
will operate in high fan speed
on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button
again or the fan speed button or the room temperature
setting button or the Fan Mode Button.
Jet Cool Mode
1
2
3
JET COOL TEMP A/SWING
FAN SPEED POWER
POWER
JET COOL
JET COOL
FAN SPEED
TEMP
FAN
or
-18-
PLASMA
PLASMA
PLASMA Purification Operation(Optional)
Press the Start/Stop button.
The unit will respond with a
beep.
1
Open the door on the remote control.
Press the PLASMA air purifying
operation ON/OFF button.
Operation will start when the button is
pressed and stop when the button is
pressed again.
2
Set the fan speed again with door of the remote control
closed. You can select the fan speed in four steps-low,
medium, high or CHAOS*. Each time the
button is pressed, the fan speed mode
is shifted.
Air purifying operation (PLASMA) can be with cooling
or any other operations.
PLASMA Air Purifying Operation only
If you press only the PLASMA button, PLASMA
air purifying operates only.
Then, fan speed is low. You can select the fan
speed in four steps-low, medium, high or
CHAOS*.
Each time the button ( ) is pressed, the fan
speed mode is shifted.
3
JET COOL TEMP A/SWING
FAN SPEED POWER
POWER
FAN SPEED
* Available in selected models. In other models, CHAOS is same as high speed.
-19-
Personal Mode (P1 / P2 / P3)
Press the Start/Stop button.
The unit will respond with a
beep.
1
Open the door on the Remote Control.
Press the Personal Mode operation button.
The last personal mode P1 or P2 or P3,
which was running will be displayed on the
control panel. The unit will start to operate
as per the last saved settings of desired
temperature, fan speed, auto-swing for the
personal mode displayed.
2
JET COOL TEMP A/SWING
FAN SPEED POWER
POWER
PERSONAL MODE
PERSONAL MODE
Settings for desired temperature, fan speed, auto-swing can
be changed for each mode P1/P2/P3 separately after the
particular mode P1/P2/P3 has been selected using the
personal mode key.
3
After the settings have been changed or not changed for
desired temperature, fan speed, auto-swing in a particular
mode (P1/P2/ P3) the temperature setting key, fan speed key
auto-swing key will be locked within 20~25 sec of the last key
pressed during the process of changing the settings. Only
buzzer will sound when these keys are pressed. However, if
the personal mode key is pressed again the keys will be
unlocked.
PERSONAL MODE
When the unit is running in any of the personal modes P1/P2/
P3 and it is turned "OFF" and then turn "ON" using the control
panel, then the unit will start in cooling mode.
Personal Mode can be cancelled using the mode key, fan key
and the jet cool key on the remote controller and mode key on
the control panel.
Personal Mode is used to save the independent setting for the desired temperature, fan speed
and auto-swing for 3 different modes P1, P2, P3. Pressing the Personal Mode key on the remote
control will change the Personal Mode in the sequence P1 – P2 – P3 – P1 on the control panel.
Temperature setting key, fan speed key and auto-swing key on the control panel will be locked as
soon as Personal Mode is selected. Only buzzer will sound when these keys are pressed.
Personal Mode will operate only when the unit is running in cool mode.
4
5
6
-20-
2nd F Operation
1
2
2nd function goes off in a short time automatically or when
the button is pressed again.
3
nd
2 F
nd
2 F
Press the Start/Stop button.
The unit will respond with
a beep.
Open the door of the remote control and press the 2nd
Function button to operate functions printed in blue at bottom
of buttons.
(Check the indication of 2nd function on remote control
display.)
nd
2 F
ON
OFF
CANCEL
SET
ET LJ COO
A/SWING
OWERP
TEMP
FAN SPEED
MODE SLEEP CANCEL
TIMERON OFF SET
FAN ROOM
TIMER
PERSONAL MODE
POWER
ON
OFF
SET
TIMERON OFF SET
TIMER
Delay OFF Timer Delay ON Timer Delay OFF and ON Timer Delay ON and OFF Timer
Additional features
Sleep Mode
Press the Sleep Mode Auto button to set the
time you want the unit to turn off automatically.
The Timer is programmed in one-hour
increments by pressing the Sleep Mode Auto
button 1 to 7 times.
The sleep mode is available for 1 to 7 times. To
alter the time period in steps of 1 hour, press
the Sleep Mode Button while aiming at air
conditioner.
Make sure the Sleep Mode Auto LED lights up.
To cancel the Sleep Mode, press the sleep
Mode Auto button several times until the star
( ) disappears from the operation display.
Note:
IN COOLING MODE : The temperature will
automatically rise by 1°C over the next 30
minutes and by 2°C in 1 hour for comfortable
sleeping.
Setting the Time
Time can be set only when you have pressed
the Reset button. If you have just replaced the
batteries, the Reset button should be pressed
to reset the time.
Press the Start/Stop button.
Press the Time Setting buttons until the
desired time is set.
Press the Timer SET button.
Note: Check the indicator
for A.M. and P.M.
Make sure the time is set correctly on the
remote control display.
Press the ON/OFF Timer
buttons to turn Timer on or off.
Press the Time Setting
buttons until the desired
time is set.
Press the selected on/off setting by
pressing the Timer SET button while
aiming the remote control at the signal
receptor.
To cancel the timer setting
Press the Timer Cancel button while
aiming remote control at the signal
receptor.
(The timer lamp on the air conditioner and
the display will go out.)
Delay Start/Pre-Set Stop
NOTE: Select one of the following four types of operation.
1
1
2
3
2
3
with the unit running
1
2
3
4
ON OFF
SET
SET
CANCEL
1. The Sleep Mode will be operated at
slow fan speed (cooling) or medium
fan speed (heat pump only) for quiet
sleeping.
2. Remote Control will display Fan Speed.
Set before sleep mode although Unit
Fan Speed changes.
SLEEP
POWER
TIMER
TIMER
TIMER
-21-
3. When Sleep Mode is active, display on
the control panel will glow dull.
- In case of Auto Restart, ON/OFF Timer is automatically cancelled.
Fan speed is on low. Fan speed is on medium. Fan speed is on high.CHAOS Air
Fan Mode
Circulates the room air without cooling.
Press the Start/Stop button. the unit will respond with a beep.
Open the door on the remote control. Press the Fan button. Close the door on the
remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is
shifted from low to CHAOS* and back to low again.
2
1
FAN
-22-
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to
operate procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
The compressor will start after 2.5~3 minutes.
* Available in selected models. In other models, CHAOS is same as high speed.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

LG LWA3BP2A Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI