Allied Telesis GS970M/28 Installation guide

Category
Network switches
Type
Installation guide

This manual is also suitable for

613-002439 REV A
CentreCOM
®
GS970M Series
MANAGED GIGABIT ETHERNET SWITCH
GS970M/10
GS970M/10PS
GS970M/18
GS970M/18PS
GS970M/28
GS970M/28PS
Installation Guide
Copyright 2017 Allied Telesis, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or
other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior
written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any
incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this
manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility
of such damages.
i
Electrical Safety and Emissions Standards
This product meets the following standards.
Radiated Energy
EMC EN 55022 Class A
EN 55024
EN 61000-3-2
EN 61000-3-3
EN 62311
FCC Part 15 (CFR 47) Class A
VCCI Class A
CISPR 22 Class A
ICES-003
Warning: In a
domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
Environmental RoHS
Compliance WEEE
Electrical Safety EN 60950-1 (edition 2)
IEC 60950-1 (edition 2)
UL 60950-1
Laser Safety EN 60825
(edition 2)
Regulatory RCM
Compliance CE
C-UL-US
UL-EU
U.S. Federal Communications Commission
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15
of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate
this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
ii
Translated Safety Statements
Important: The indicates that a translation of the safety statement is available in a PDF
document titled Translated Safety Statements posted on the Allied Telesis website at
www.alliedtelesis.com.
iii
Contents
Preface............................................................................................................................................................... 1
Symbol conventions ..................................................................................................................................... 2
Contacting Allied Telesis.............................................................................................................................. 3
Chapter 1: Overview .......................................................................................................................................... 5
Features....................................................................................................................................................... 6
Twisted pair ports .................................................................................................................................. 6
SFP slots ............................................................................................................................................... 6
LEDs...................................................................................................................................................... 7
Installation options................................................................................................................................. 7
Power conservation ............................................................................................................................... 7
MAC address table ................................................................................................................................ 7
Package contents for the GS970M/10 and GS970M/10PS Switch.............................................................. 8
Package contents for GS970M/18 and GS970M/18PS Switches................................................................ 9
Package contents for the GS970M/28 Switch............................................................................................ 10
Package contents for the GS970M/28PS Switch....................................................................................... 11
Front and back panels on the GS970M/10 Switch..................................................................................... 12
Front and back panels on the GS970M/10PS Switch ................................................................................14
Front and back panels on the GS970M/18 Switch..................................................................................... 16
Front and back panels on the GS970M/18PS Switch ................................................................................18
Front and back panels on the GS970M/28 Switch..................................................................................... 20
Front and back panels on the GS970M/28PS Switch ................................................................................22
Management software................................................................................................................................ 24
Twisted pair ports....................................................................................................................................... 25
Cable requirements for non-PoE ports ................................................................................................ 25
Power over Ethernet (PoE) ........................................................................................................................ 27
PoE standards ..................................................................................................................................... 27
Powered device classes ...................................................................................................................... 28
Cable requirements ............................................................................................................................. 28
Power budget ...................................................................................................................................... 29
Port prioritization.................................................................................................................................. 30
Wiring implementation ......................................................................................................................... 31
LEDs ...........................................................
............................................................................................... 32
POWER and FAULT LEDs.................................................................................................................. 32
10/1000BASE-T/100BASE-TX Link/Activity/Speed LED and PoE status LED ................................... 34
10/1000BASE-T/100BASE-TX Link/Activity/Speed LED and Duplex/Collision LED ........................... 36
SFP LEDs............................................................................................................................................ 38
SD card LED........................................................................................................................................ 39
ecofriendly button....................................................................................................................................... 41
Power supply.............................................................................................................................................. 42
Fans ........................................................................................................................................................... 43
Chapter 2: Installation ...................................................................................................................................... 45
Reviewing safety precautions .................................................................................................................... 46
Selecting a site for the switch..................................................................................................................... 48
Cable specifications ................................................................................................................................... 49
Unpacking the switch:GS970M/10 and GS970M/10PS ............................................................................. 50
Unpacking the switch: GS970M/18 and GS970M/18PS ............................................................................ 51
Unpacking the switch: GS970M/28 ............................................................................................................ 52
Unpacking the switch: GS970M/28PS ....................................................................................................... 53
Installing the switch on a table or a desktop .............................................................................................. 54
Removing the feet from a switch before installing it in an equipment rack or on a wall ............................. 55
iv
Installing a GS970M/10 switch in an equipment rack.................................................................................56
Installing a GS970M/10PS switch in an equipment rack ............................................................................59
Installing a GS970M/18, GS970M/18PS or GS970M/28 switch in an equipment rack .............................. 61
Installing a GS970M/28PS switch in an equipment rack ............................................................................63
Installing a GS970M/10 switch on a wall .................................................................................................... 65
Installing a GS970M/18, GS970M/28 or AT-GS970M PS Series switch on a wall.....................................67
Cabling the switch ......................................................................................................................................69
Powering on the switch............................................................................................................................... 71
Starting a local management session......................................................................................................... 73
Monitoring the initialization processes........................................................................................................75
Installing optional SFP transceivers ........................................................................................................... 78
Chapter 3: Troubleshooting .............................................................................................................................81
Appendix A: Technical Specifications .............................................................................................................. 85
Physical specifications................................................................................................................................ 85
Dimensions .......................................................................................................................................... 85
Weight..................................................................................................................................................85
Environmental specifications ...................................................................................................................... 86
Power specifications...................................................................................................................................86
Electrical safety and electromagnetic certifications ....................................................................................87
Connectors and port pinouts ......................................................................................................................88
v
Figures
Figure 1: GS970M/10 and GS970M/10PS packaging ........................................................................................................... 8
Figure 2: GS970M/18 and GS970M/18PS packaging ........................................................................................................... 9
Figure 3: GS970M/28 packaging......................................................................................................................................... 10
Figure 4: GS970M/28PS packaging .................................................................................................................................... 11
Figure 5: GS970M/10 front panel ........................................................................................................................................ 12
Figure 6: GS970M/10 back panel........................................................................................................................................ 13
Figure 7: GS970M/10PS front panel ................................................................................................................................... 14
Figure 8: GS970M/10PS back panel ................................................................................................................................... 15
Figure 9: GS970M/18 front panel ........................................................................................................................................ 16
Figure 10: GS970M/18 back panel...................................................................................................................................... 17
Figure 11: GS970M/18PS front panel ................................................................................................................................. 18
Figure 12: GS970M/18PS back panel ................................................................................................................................. 19
Figure 13: GS970M/28 front panel ...................................................................................................................................... 20
Figure 14: GS970M/28 back panel...................................................................................................................................... 21
Figure 15: GS970M/28PS front panel ................................................................................................................................. 22
Figure 16: GS970M/28PS back panel ................................................................................................................................. 23
Figure 17: POWER LED on a GS970M Series Switch........................................................................................................ 32
Figure 18: FAULT LED on a GS970M Series Switch .......................................................................................................... 33
Figure 19: Link/Activity/Speed and PoE LEDs..................................................................................................................... 34
Figure 20: Link/Activity/Speed and Duplex/Collision LEDs.................................................................................................. 36
Figure 21: SFP Link/Activity LEDs on a GS970M Series Switch......................................................................................... 38
Figure 22: SD card slot LED on a GS970M Series Switch.................................................................................................. 39
Figure 23: ecofriendly button on a GS970M Series Switch ................................................................................................. 41
Figure 24: Attaching the rubber feet to a switch .................................................................................................................. 54
Figure 25: Removing the rubber feet from a switch............................................................................................................. 55
Figure 26: Fitting handles to rack mount brackets............................................................................................................... 56
Figure 27: Fitting brackets to the mounting ......................................................................................................................... 56
Figure 28: Attaching cable tray brackets ............................................................................................................................. 57
Figure 29: Mounting a GS970M/10 Switch in the brackets.................................................................................................. 57
Figure 30: Mounting a GS970M/10 Switch in the rack ........................................................................................................ 58
Figure 31: Securing cables to the cable tray ....................................................................................................................... 58
Figure 32: Attaching rack mount brackets to a GS970M/10PS ........................................................................................... 59
Figure 33: Mounting a GS970M/10PS switch in an equipment rack ................................................................................... 60
Figure 34: Attaching rack mount brackets to the GS970M/18, GS970M/18PS or GS970M/28 switch................................ 61
Figure 35: Mounting a GS970M/18, GS970M/18PS or
GS970M/28 switch in an equipment rack ............................................................................................................................ 62
Figure 36: Attaching rack mount brackets to the GS970M/28PS switch ............................................................................. 63
Figure 37: Mounting a GS970M/28PS switch in an equipment rack ................................................................................... 64
Figure 38: Ridges on the AT-BRKT-J23 that the switch rests on when installed with the front panel facing up ................. 65
Figure 39: Securing the GS970M/10 switch to the wall with the front panel facing up ........................................................ 66
Figure 40: Securing the GS970M/10 switch to the wall with the front panel facing right ..................................................... 66
Figure 41: Attaching wall mount brackets to the side of the switch ..................................................................................... 67
Figure 42: Securing the switch to the wall .......................................................................................................................... 68
Figure 43: Lifting the AC power cable hook on a GS970M Series Switch........................................................................... 71
Figure 44: Plugging in the AC power cord on a GS970M Series Switch............................................................................. 71
Figure 45: Connecting the management cable to the console port of a GS970M Series Switch ........................................ 73
Figure 46: Switch initialization messages............................................................................................................................ 75
Figure 47: Switch initialization messages (continued) ......................................................................................................... 76
Figure 48: Switch initialization messages (continued) ........................................................................................................ 77
Figure 49: Removing the dust plug from an SFP slot............................................................................
.............................. 78
Figure 50: Inserting an SFP transceiver into an SFP slot.................................................................................................... 79
Figure 51: Positioning the SFP handle in the upright position ............................................................................................ 79
Figure 52: Ejecting an SFP transceiver after lowering the SFP handle to the downwards position .................................... 80
Figure 53: RJ45 connector and port pin layout.................................................................................................................... 88
vi
vii
Tables
Table 1. Twisted pair cable requirements for the non-PoE ports........................................................................................ 25
Table 2. IEEE powered device classes............................................................................................................................... 28
Table 3. Twisted pair cable requirements for the 10BASE-T and 100BASE-TX ports at 10 or 100Mbps........................... 28
Table 4. Twisted pair cable requirements for the 10/1000BASE-T and 100BASE-TX ports at 1000Mbps......................... 29
Table 5. POWER LED functional descriptions................................................................................................................... 33
Table 6. FAULT LED functional descriptions....................................................................................................................... 33
Table 7. Link/Activity/Speed and PoE LED descriptions..................................................................................................... 35
Table 8. Link/Activity/Speed and Duplex/Collision LED descriptions.................................................................................. 37
Table 9. SFP Link/Activity LED functional descriptions....................................................................................................... 39
Table 10. SD card LED functional descriptions................................................................................................................... 40
Table 11. Twisted pair cabling and distances..................................................................................................................... 49
Table 12. Chassis dimensions............................................................................................................................................. 85
Table 13. Chassis weight..................................................................................................................................................... 85
Table 14. Environmental specifications............................................................................................................................... 86
Table 15. Input supply voltage............................................................................................................................................. 86
Table 16. Power specifications............................................................................................................................................ 86
Table 17. Safety and electromagnetic emissions certifications........................................................................................... 87
Table 18. MDI pin signals (10BASE-T or 100BASE-TX)..................................................................................................... 88
Table 19. MDIX pin signals (10BASE-T or 100BASE-TX)................................................................................................... 88
Table 20. RJ-45 1000BASE-T connector pinouts................................................................................................................ 89
viii
GS9790M Series Switch Installation Guide
1
Preface
This guide contains the installation instructions for the following GS9790M
Series Switches:
GS970M/10
GS970M/10PS
GS970M/18
GS970M18PS
GS970M/28
GS970M/28PS
This preface contains the following sections:
“Symbol conventions” on page 2
“Contacting Allied Telesis” on page 3
Preface
2
Symbol conventions
This document uses the following conventions:
Note
Notes provide additional information.
Caution
Cautions inform you that performing or omitting a specific action
may result in equipment damage or loss of data.
Warning
Warnings inform you that performing or omitting a specific action
may result in bodily injury.
Warning
Warnings inform you that an eye and skin hazard exists due to the
presence of a Class 1 laser device.
GS9790M Series Switch Installation Guide
3
Contacting Allied Telesis
If you need assistance with this product, you may contact Allied Telesis
technical support by going to the Support & Services section of the Allied
Telesis web site at
www.alliedtelesis.com/support. You can find links for
the following services on this page:
24/7 Online Support - Enter our interactive support center to
search for answers to your questions in our knowledge database,
check support tickets, learn about RMAs, and contact Allied
Telesis technical experts.
USA and EMEA phone support - Select the phone number that
best fits your location and customer type.
Hardware warranty information - Learn about Allied Telesis
warranties and register your product online.
Replacement Services - Submit a Return Merchandise
Authorization (RMA) request via our interactive support center.
Documentation - View the most recent installation guides, user
guides, software release notes, white papers and data sheets for
your product.
Software Updates - Download the latest software releases for your
product.
For sales or corporate contact information, go to
www.alliedtelesis.com/how-to-buy and select your region.
Preface
4
GS9790M Series Switch Installation Guide
5
Chapter 1: Overview
This chapter provides descriptions of the GS970M/10, GS970M/10PS,
GS970M/18, GS970M/18PS, GS970M/28, and GS970M/28PS Gigabit
Ethernet Switches and contains the following sections:
“Features” on page 6
“Package contents for the GS970M/10 and GS970M/10PS Switch”
on page 8
“Package contents for GS970M/18 and GS970M/18PS Switches”
on page 9
“Package contents for the GS970M/28 Switch” on page 10
“Package contents for the GS970M/28PS Switch” on page 11
“Front and back panels on the GS970M/10 Switch” on page 12
“Front and back panels on the GS970M/10PS Switch” on page 14
“Front and back panels on the GS970M/18 Switch” on page 16
“Front and back panels on the GS970M/18PS Switch” on page 18
“Front and back panels on the GS970M/28 Switch” on page 20
“Front and back panels on the GS970M/28PS Switch” on page 22
“Twisted pair ports” on page 25
“Power over Ethernet (PoE)” on page 27
“LEDs” on page 32
“ecofriendly button” on page 41
“Power supply” on page 42
“Fans” on page 43
Chapter : Chapter 1: Overview
6
Features
This section describes the hardware features of the GS970M Series
Gigabit Ethernet Switches.
Twisted pair
ports
Here are the basic features of the 10/100/1000Mbps twisted-pair ports:
GS970M/10, GS970M/18 or GS970M/28 switches: 8, 16 or 24
non-PoE ports per switch
GS970M/10PS, GS970M/18PS, or GS970M/28PS switches: 8, 16
or 24 PoE ports per switch
10BASE-T (IEEE 802.3i), 100BASE-TX (IEEE 802.3u) and
1000BASE-T (IEEE 802.3ab) compliant
IEEE 802.3u Auto-Negotiation compliant
Auto-MDI/MDIX
PoE Plus
Full wire-speed non-blocking
IEEE 802.3x Flow Control in 10BASE-T/100BASE-TX full-duplex
operation
IEEE 802.3x Back Pressure in 10BASE-T/100BASE-TX half-
duplex operation
IEEE803.3z 1000BASE-T Flow Control
Support for jumbo packets up to 10KB
One RJ45 connector on front panel for RS232 console purposes.
SFP slots Here are the basic features of the SFP ports:
GS970M/10, GS970M/10PS,GS970M/18 and
GS970M/18PS switches: 2 SFP ports per switch
GS970M/28 and GS970M/28PS switches: 4 SFP ports per switch.
Available for 100Mbps or 1000Mbps of fiber, and 1000Mbps of
copper
Support 100BASE-FX and 1000BASE-SX/LX transceivers.
You need to purchase SFP transceivers separately. For a list of supported
transceivers, contact your Allied Telesis distributor or reseller.
Note
See the product data sheets for the specific ATI SFP modules
supported by the GS970M Series switches.
GS9790M Series Switch Installation Guide
7
LEDs Here is a brief description of the port LEDs:
POWER and FAULT LEDs; refer to “POWER and FAULT LEDs”
on page 32.
Link/Activity/Speed/PoE LEDs for the PoE twisted pair ports; see
“10/1000BASE-T/100BASE-TX Link/Activity/Speed LED and PoE
status LED” on page 34.
Link/Activity/Speed/Duplex/Collision LEDs for the non-PoE twisted
pair ports; see “10/1000BASE-T/100BASE-TX Link/Activity/Speed
LED and Duplex/Collision LED” on page 36.
Link/Activity LEDs for the SFP slots; see “SFP LEDs” on page 38.
SD card LED: refer to “SD card LED” on page 39.
Note
The ecofriendly button turns off the LEDs (excluding the POWER
LED and SD card LED) to conserve electricity. See “ecofriendly
button” on page 41.
Installation
options
The switches can be installed in the following ways:
Rack mounted in a 19-inch equipment rack
Mounted on a desk or tabletop
Wall mounted
Power
conservation
The switches implement Eco-Switch Green Power saving features and
use less power than the METI specification. The switches have the
following power conservation features:
ecofriendly button to turn off the port LEDs when the system is not
being monitored
High efficiency power supply
Power scaling based on traffic loads on ports operating at
1000Mbps (port power scaling not available at 10 or 100Mbps)
Power shutdown on unused ports
MAC address
table
Here are the basic features of the MAC address table:
Storage capacity up to 16K MAC address entries
Automatic learning and aging
Chapter : Chapter 1: Overview
8
Package contents for the GS970M/10 and GS970M/10PS Switch
Figure 1 illustrates the package contents for the GS970M/10 and
GS970M/10PS Gigabit Ethernet Switch.
FIGURE 1. GS970M/10 AND GS970M/10PS PACKAGING
1 Power cable hook
GS970M/10 or
GS970M/10PS
1 Power cable (1.8m)
1 Console cable (2m)
C
O
N
SO
L
E
R
S-2
3
2
SD
F
AU
LT
PO
W
ER
S
D
10
00
L
I
N
K
A
C
T
1
0/
1
0
0
L
I
N
K
AC
T
P
D
O
N
PD
E
R
R
M
A
X
C
U
R
R
E
N
T
S
F
P
9
1
0
2
4
6
8
13
57
MA
C Addre
s
s
L
a
be
l
GS9790M Series Switch Installation Guide
9
Package contents for GS970M/18 and GS970M/18PS Switches
Figure 2 illustrates the package contents for the GS970M/18 and
GS970M/18PS Gigabit Ethernet Switches.
FIGURE 2. GS970M/18 AND GS970M/18PS PACKAGING
1 Power cable hook
GS970M/18 or
GS970M/18PS
1 Power cable (1.8m)
1 Console cable (2m)
M
AC
Ad
d
r
es
s
La
b
e
l
Chapter : Chapter 1: Overview
10
Package contents for the GS970M/28 Switch
Figure 3 illustrates the package contents for the GS970M/28 Gigabit
Ethernet Switch.
FIGURE 3. GS970M/28 PACKAGING
2 x Brackets
6 x Screws
1 Power cable (1.8m)
1 Console cable (2m)
GS970M/28
1 Power cable hook
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Allied Telesis GS970M/28 Installation guide

Category
Network switches
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI