Dehumidifier
AB-L 220
Operating instructions
EN
the dry solution
- 2 -ALLEGRA Dehumidifier AB-L 220
Dear Customer!
Thank you for choosing a product from ALLEGRA.
Please read the complete instructions for use before putting the appliance into operation. The infor-
mation can help you for a safely and smooth handling of your new device. Keep this manual in a safe
place so that you can refer to it when needed. Please observe all safety instructions and information
on use and maintenance in this manual. This manual should be attached to the device if the latter is
made available to other persons for use.
YOUR ALLEGRA TEAM
Table of contents
1. Important safe instructions. . . . . . . . . . . . . .3
3. Components . . . . . . . . . . . . . . . . . . . . . . . .4
4. Operating Introduction . . . . . . . . . . . . . . . . .4
4.1. Functions of control panel &
key pads . . . . . . . . . . . . . . . . . . . . . . .4
4.2. Operation of key pads . . . . . . . . . . . . . 5
4.3. Automatic defrosting . . . . . . . . . . . . . .6
4.4. Water full . . . . . . . . . . . . . . . . . . . . . . .6
4.5. Continuous drainage . . . . . . . . . . . . . . 6
4.6. Processions of
abnormal compressor . . . . . . . . . . . . .6
4.7. Protection Of Extremely Low &
High Temperature. . . . . . . . . . . . . . . . .6
4.8. Failures of humidity &
temperature sensor . . . . . . . . . . . . . . .7
5. Ambient environment
for operating . . . . . . . . . . . . . . . . . . . . . . . . 7
6. Specification . . . . . . . . . . . . . . . . . . . . . . . .7
7. Maintenances & cleaning. . . . . . . . . . . . . . . 7
8. Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . .8
9. Declaration of conformity. . . . . . . . . . . . . . .8
About these instructions
Maybe there are some pictures, which are different from what you have seen in the real model in this
manual. All are subject to real goods. New specifications are changed for improving quality without
further notice.
WARNING SYMBOL
This symbol introduces a
warning, which can lead to
non-compliance to serious
injury or death and/or proper-
ty damage. Follow the safety instructions in this
manual! Failure to comply can have serious con-
sequences for the health of people and damage
to property and harm to the environment which
might arise.
This manual is part of the dehumidifier and must
be always accessible.
Please read this manual thoroughly and comple-
tely before using the device. Only use the device
in accordance with the instructions contained
herein!
Do not operate the device if there are any unans-
wered questions regarding the use and operati-
on of the device. In this case, please contact the
ALLEGRA customer service.
- 3 -ALLEGRA Dehumidifier AB-L 220
1. Important safe instructions
Do not install and use the unit befo-
re carefully reading this instruction
guide. Please retain this manual for
future reference.
Please be sure your electricity is correct
To protect against electrical shock, do not place
it in near window or in bathroom
Please ensure the unit is not placed closely to
the high temperature appliance, in case of pla-
stic destroying and fire.
Never operate this unit in an explosive or cor-
rosive atmosphere.
Always guide if children operate. Never disas-
semble the unit, and never try to carry out re-
pairs or adjust the unit yourself.
Operate this unit on a horizontal surface to
avoid vibration and noise.
Do not use the unit when slanted. If toppled
over, please pull out the plug at once.
Make sure the inlet and outlet ventilation is not
blocked at all times.
Ensure there is 30 cm of clear space on all si-
des of the unit.
Do not spray water on the unit, spraying water
may cause malfunctioning and electric shock.
Never pull the socket by using damp hands.
Always switch off at the socket before unplug-
ging to avoid electric shock or arcing.
Switch off and unplug the unit, empty the wa-
ter reservoir when not using the unit for a long
time.
Do not pull power wire by force because it will
cause damage to power wire.
Never put fingers or other objects in any
openings of the unit.
Care should be taken when using the unit,
unplug the appliance during cleaning.
If the supply cord is damaged, it must be repla-
ced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a
hazard.
This appliance may not be used by children.
Children must be not allowed to play with the
appliance.
This appliance may be used by people with
reduced physical, sensory or mental capabi-
lities, or who lack sufficient experience and/
or knowledge, provided they are supervised or
have been trained in the safe use of the ap-
pliance and understand the potential dangers.
This marking indicates that this pro-
duct should not be disposed with other
household wastes throughout the EU.
To prevent possible harm to the en-
vironment or human health from uncontrolled
waste disposal, recycle it responsibly to promote
the sustainable reuse of material resources. To
return your used device, please use the return
and collection systems or contact the retailer
where the product was purchased. They can take
this product for environmental safe recycling.
- 4 -ALLEGRA Dehumidifier AB-L 220
3. Components
4. Operating introduction
4.1. Functions of control panel & key pads
Dry air outlet
Control panel
Handle
Humid air inlet
Permanent
drainage tube
Water tank
Sensor
Water pane
POWER:
Switch on/off
the power.
HUMID:
Set Working Humidity Ratio
(40%RH, 60%RH, 80%RH
and continuous operating)
TIMER:
Reserve & turn off hours
settings (1 – 8 hours)
SPEED:
Setting wind speed
high / low.
- 5 -ALLEGRA Dehumidifier AB-L 220
Press SPEED:
3. Press SPEED button to select the fan blower
working at “High speed” level or “Low speed”
level.
TIMER:
4. Press “TIMER” to select the desired hour of
automatic shut off at 1H, 2H, 4H, 8H.
Humidity:
5. Press HUMID to select the desired ambient re-
lative humidity at 40% RH, 60% RH, 80% RH.
4.2. Operation Of Key Pads:
1. When plug into power socket, 3 beep signals
can be heard. Simultaneously all indicator light
will illuminate and the indicator light will turn
off after 1 second.
2. Press the “POWER” button to turn on the unit.
The “RUN” indicator light will illuminate.
The unit is default at automatic high speed
when switched on.
The automatic shut off function is not activa-
ted & the unit is in standby status.
The automatic control of humidity function
is not activated & the unit is in the status of
constant dehumidifying.
Press the “POWER” button again, the unit
will stop working.
The fan blower will automatically switch to
operate at “High speed” level when the am-
bient temperature is higher or equal to 32°C
that detected by the temperature sensor built
in the unit.
Press “TIMER” to select the desired hour of
automatic shut off, the related indicator light
will illuminate. The unit will continue opera-
ting without setting timer, the indicator light
of automatic shut off will not illuminate.
The timer setting will be calculated auto-
matically and the indicator light of automatic
shut off will indicate the hour of remainder.
The unit will switch off automatically & stop
working when the timer setting run out.
Press HUMID …
1 x to select the desired ambient relative
humidity at 40% RH
2 x: to select the desired ambient relative
humidity at 60% RH
3 x: to select the desired ambient relative
humidity at 80% RH.;
4 x: to select the constant dehumidifying
function.
The unit will stop dehumidifying automati-
cally when the ambient relative humidity is
2% RH lower than the setting %RH, the indi-
cator light of “RUN” turn off. The fan blower
will operate at “Low speed” level.
The unit will start to dehumidify automati-
cally when the ambient relative humidify is
2% RH higher than the setting %RH, the in-
dicator light of “RUN” will illuminate. The fan
blower keeps runing as per the setting level.
The unit continue operating without consi-
dering the ambient relative humidity when it
is set to operate under the mode of “CONT-
INUE”, the continue pilot lamp is exhibiting.
- 6 -ALLEGRA Dehumidifier AB-L 220
4.3. Automatic defrosting
1. When the temperature sensor on the copper
pipe detects the surface of the evaporator
dropped down to -1°C, the auto defrost fun-
ction is start up.
2. The frost thawing and the temperature sen-
sor detects the the surface of the evapora-
tor is higher than 3°C, defrost function will
stop and dehumidifying function start up.
When defrosting, indicator light of defrost will
illuminate and the indicator light of dehumi-
difying will turn off.
4.6. Processions of abnormal compressor
During the operation, any malfunction forced
compressor failed, resulting compressor shut
off, it takes 3 minutes to rework for protection
period.
4.7. Protection of extremely
low or high temperature
When sensor detected ambient temperature is
0°C or 40°C,as to protect the unit which will
shut off automatically and beeper continuous
warning with 3 long and 2 short signals.
4.5. Continuous drainage
Remove water plug and connect with PVC hose
with spigot.
Symbol of defrost displayed on LCD, the
compressor is shut off, fan runs at high
speed.
Symbol of dehumidifying displayed on LCD,
the compressor will work, and fan runs at
original set speed.
After water reservoir removed and intend to
reinstate the operation, it takes about 3 mi-
nutes to start the unit again for protection
purpose. To scrub off protection time, you may
remove plug from power socket to restart the
unit.
All function keys are out of functions, you
should plug off to restart the unit.
Any abnormal over heating is greater than
40°C of unit internally, the unit shut off as
well.
PVC hose must be placed on the ground flat-
ly.
Do not tangle the hose.
Do not immerse the end of water outlet into
other receptacle to avoid water flow blocked.
Remove water
reservoir as
arrow direction
4.4. Protection of water full
When condensed water is full, buzzer will alarm
10 times. (about 5 seconds) Whilst, the symbol
of water full exhibited on LCD screen, all other
symbols are disappeared. The water reservoir
must be removed to empty and reinstalled be-
fore the unit operates again. The interval of
dehumidifying takes about 3 minutes, owing to
compressor is under protection.
- 7 -ALLEGRA Dehumidifier AB-L 220
4.8. Failures of humidity or
temperature sensor
When the connect wire of humidity and tem-
perature sensor break off, the continue pilot
lamp will wink, the unit comes into continuous
dehumidifying mode out of humidity control, it
can work after obviating the failure.
When the temperature sensor of evaporator
appears open circuit or short circuit, the de-
frosting pilot lamp will wink, the unit turns into
settled dehumidifying and defrosting mode:
dehumidifying for 20 minutes, then defrosting
for 5 minutes.
1. Before any maintenance or cleaning, please
switch off and unplug the unit.
2. For its casing is made of wood and plastic, do
not place it in direct sunlight.
3. Remove the water tank with care.
4. If not using the unit for a long time. Please
Switch off and unplug the unit, empty the wa-
ter reservoir, and pack it after 2 days, then,
keep it in dry and ventilated place.
5. Only use a soft clean cloth for all cleaning
purpose. Do not use gasoline, paint thinner or
other chemicals to clean the unit.
6. Cleaning mesh filter: Remove the filter. Use a
vacuum cleaner or water to clean, then put it
in ventilated place until it‘s dry.
7. Maintenance & cleaning
6. Specification
Model AB-L 220
Power Rated 220-240 V AC/50Hz
Moisture removal 20 L/D (30°C RH80%)
Dehumidifying Power 400W (35°C RH90%)
Refrigerant R134a / 145 grams
Capacity of Water Tank 3,7 liter
Unit Dimension 390 L × 273 B × 572 H
CAUTION!
The appliance shall be installed in accordance
with national wiring regulations.
5. Ambient environment
for operating
The appliance is designed to provide an opti-
mum performance not recommended to ope-
rate in ambient temperature exceeds 35°C
(Wet ball 30°C) or lower than 5°C
Operate the unit indoors, e.g. Living room, be-
droom, etc. Never use it in wet environment or
outdoors.
Make sure the door and window are closed be-
fore turning on the unit.
Ensure that the unit is placed on a stable and
flat floor surface.If the floor surface is not even
there is a risk that the unit may be unstable
and topple over. Also excessive vibration and
noise may be result.
8. Guarantee
If there is a fault on your device, we ask you to
contact our Technical Hotline at first (+49 / 30 5
111 600) or the dealer to contact from whom you
purchased the product. If we can not solve the
problem in this way, please return the unit back
to the appropriate dealer.
Excluded from the warranty are external visual
defects, beyond damage caused by improper
installation or incorrect operation or mechani-
cal damage. No guarantee if the serial number
has been removed or damaged.
The intervention of unauthorized third parties,
the warranty expires.
The warranty covers the repair or replacement
of the defective part, but not your necessary
expenses.
ALLEGRA Trocknungstechnik Vertriebs GmbH
We point out that we refuse New-appliance,
if it is compared with the correction of faults
associated with disproportionately high costs
(represents the rule).
The defective equipment or part must be re-
turned with an error description in the original
packaging, including accessories and the in-
voice (copy) and in case of warranty with war-
ranty card to the ALLEGRA Trocknungstechnik
Vertriebs GmbH. Shipments without freight
prepaid will not be accepted.
We declare that the product „Dehumidifier AB-L 220“ to which this declaration relates, is compliant
with the following directives and standards:
9. Declaration of conformity
EN60335-1
EN60335-2-30
EN50366
The Management of
ALLEGRA Trocknungstechnik Vertriebs GmbH
Tel. +49 (0) 30 5 111 600
[email protected] www.allegra24.de
Nüßlerstraße 30,
D-13088 Berlin
the dry solution
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Allegra AB-L 220 Operating Instructions Manual

Category
Dehumidifiers
Type
Operating Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI