PSG PF01100 Owner's manual

Category
Stoves
Type
Owner's manual
45391E
08/21/2009
PSG
1700, Léon-Harmel
Québec (Québec)
G1N 4R9
Installation and operating instructions
for the MAX CADDY wood furnace
CERTIFIED ACCORDING TO CAN/CSA B366.1 M91,UL391 4
TH
EDITION 2006, CAN/CSA C22.2 NO.236-05, UL
1995 3
RD
EDITION 2003, CSA B140.4-04 AND UL 727 9
TH
EDITION 2006
FURNACE MODELS INCLUDED IN THIS MANUAL
MAX CADDY WOOD AND COMBINATION FURNACE
20kW/25kW and UH-Max Caddy
Read these instructions carefully before installing
and operating your furnace.
CONGRATULATIONS!
You have purchased one of the finest wood
or combination furnaces available on the market.
We are confident that your furnace will provide years of comfort and safe
operation.
Please keep this document!
READ THE MANUAL THOROUGHLY
BEFORE OPERATING THE FURNACE
1
TABLE OF CONTENT
WOOD OR WOOD/ELECTRIC COMBINATION FURNACES .......................................................... 4
1. CHIMNEY AND DRAFT ....................................................................................................................... 4
2. SAFETY RULES ..................................................................................................................................... 4
GENERAL REQUIREMENTS .................................................................................................................. 4
ODOUR FROM THE PAINT ..................................................................................................................... 5
ASH DISPOSAL ........................................................................................................................................ 5
CREOSOTE BUILD-UP AND REMOVAL .............................................................................................. 5
SMOKE DETECTOR ................................................................................................................................. 6
DOOR GLASS ........................................................................................................................................... 6
GLASS SPECIFICATIONS ....................................................................................................................... 6
ASH DRAWER .......................................................................................................................................... 6
ASH GRATE .............................................................................................................................................. 6
3. APPLIANCE INSTALLATION ............................................................................................................. 7
UNIT LOCATION ..................................................................................................................................... 7
BLOWER INSTALLATION AT THE BACK OF THE UNIT .................................................................. 7
PC BOARD INSTALLATION ................................................................................................................... 7
CLEARANCES TO COMBUSTIBLE MATERIALS ............................................................................... 8
FLUE AND BAROMETRIC DRAFT CONTROL CONNECTION ......................................................... 9
DAMPER .................................................................................................................................................. 10
COMBUSTION AIR ................................................................................................................................ 10
PARALLEL INSTALLATION ................................................................................................................ 12
ELECTRICAL CONNECTIONS ............................................................................................................. 13
MAX CADDY-WOOD ONLY ................................................................................................................ 13
MAX CADDY WOOD/ELECTRIC ....................................................................................................... 14
ELECTRICAL ELEMENT (MAX CADDY WOOD / ELECTRIC) ........................................................ 14
THERMOSTAT ....................................................................................................................................... 15
Wood furnace only ................................................................................................................................ 15
Combination wood-electric or wood-oil furnace ................................................................................. 15
TRIO furnace (wood-oil-electric or wood-electric-oil ) ....................................................................... 15
FAN CONTROL ....................................................................................................................................... 15
DOMESTIC WATER PRE-HEATING OPTION .................................................................................... 15
INSTALLATION OF AN AIR CONDITIONING UNIT ......................................................................... 16
4. OPERATING INSTRUCTIONS ........................................................................................................... 17
PC BOARD (CONTROL SYSTEM) ........................................................................................................ 17
FIRST USE GENERAL INFORMATION ............................................................................................ 17
FIRST USE - SETTTINGS ....................................................................................................................... 17
The use of the “BI-ENERGY” function ................................................................................................ 18
MODES, OPTIONS, AND PROGRAMMING ........................................................................................ 18
The speeds ............................................................................................................................................. 18
System Balancing .................................................................................................................................. 19
2
HEAT Mode (automatic heating) .......................................................................................................... 19
COOL Mode (air conditioning) ............................................................................................................ 19
CIRC (air circulation) .......................................................................................................................... 20
MANU (manual heating) ...................................................................................................................... 20
The Selections ....................................................................................................................................... 21
LIGHTING ............................................................................................................................................... 21
PREHEATING ......................................................................................................................................... 22
HEATING ................................................................................................................................................ 22
EARLY SIGNS OF AN OVERFIRED FURNACE: ................................................................................ 22
WOOD AS HEATING FUEL ................................................................................................................... 22
PROLONGED POWER FAILURE .......................................................................................................... 23
CHIMNEY FIRES .................................................................................................................................... 23
5. MAINTENANCE .................................................................................................................................... 24
MAINTENANCE OF THE EXCHANGERS ........................................................................................... 24
CHIMNEY MAINTENANCE ................................................................................................................. 25
MAINTENANCE OF THE BLOWER MOTOR ...................................................................................... 25
FILTERS .................................................................................................................................................. 25
DOOR GASKET MAINTENANCE ........................................................................................................ 25
6. REPLACEMENT PARTS ..................................................................................................................... 26
DOOR GLASS ......................................................................................................................................... 26
GASKET .................................................................................................................................................. 26
7. GENERAL ELECTRIC DIAGRAM WITH BECKETT OIL BURNER ......................................... 27
8. GENERAL ELECTRIC DIAGRAM WITH RIELLO OIL BURNER ............................................ 28
9. ELECTRIC DIAGRAM WITH OPTIONAL ELECTRICAL ELEMENT ..................................... 29
10. MAX CADDY TECHNICAL DATA .................................................................................................. 30
GENERAL TECHNICAL DATA ............................................................................................................ 30
TECHNICAL DATA ELECTRICAL ELEMENT ................................................................................ 30
11. MAX CADDY BRICKS LAYOUT ..................................................................................................... 31
12. TROUBLE SHOOTING ...................................................................................................................... 31
WOOD/OIL COMBINATION FURNACE ............................................................................................. 33
GENERAL NOTES .................................................................................................................................... 34
1. DRAFT AND CHIMNEY ...................................................................................................................... 34
2. OIL TANK AND PIPING ...................................................................................................................... 34
BURNER PUMP ...................................................................................................................................... 34
3. APPLIANCE INSTALLATION ........................................................................................................... 35
LOCATING THE UNIT ........................................................................................................................... 35
POSITIONING THE APPLIANCE .......................................................................................................... 35
PIPE CONNECTOR AND DAMPER ...................................................................................................... 36
COMBUSTION AIR ................................................................................................................................ 38
ELECTRICAL WIRING .......................................................................................................................... 38
THERMOSTAT ....................................................................................................................................... 38
3
FAN CONTROL ....................................................................................................................................... 38
COMBUSTION SAFETY CONTROL .................................................................................................... 38
COMBUSTION ADJUSTMENT AND VERIFICATION ....................................................................... 39
ELECTRODES SETTING ....................................................................................................................... 40
4- APPLIANCE START-UP ...................................................................................................................... 40
5- PROLONGED CLOSING ..................................................................................................................... 40
6- MAINTENANCE ................................................................................................................................... 41
SERVICE .................................................................................................................................................. 41
MAINTENANCE ..................................................................................................................................... 41
FILTERS .................................................................................................................................................. 42
7- ELECTRICAL DIAGRAMS ................................................................................................................ 42
8- TECHNICAL DATA ............................................................................................................................. 45
LIMITED LIFETIME WARRANTY ...................................................................................................... 46
IMPORTANT NOTE:
THE INSTALLATION OF THIS CENTRAL HEATING SYSTEM MUST BE PERFORMED BY A
QUALIFIED TECHNICIAN. PSG RESERVES ITSELF THE RIGHT TO VOID ITS WARRANTY
OR DENY TECHNICAL ADVICE IF THE FURNACE HAS NOT BEEN SOLD OR INSTALLED
BY A PROFESSIONAL.
REGISTER YOU WARRANTY ONLINE
To receive full warranty coverage, you will need to
show evidence of the date you purchased your
furnace. Keep your sales invoice. We also
recommend that you register your warranty online at
www.psg-distribution.com
Registering your warranty online will help us track
rapidly the information we need on your furnace.
4
SECTION A:
WOOD OR WOOD/ELECTRIC COMBINATION FURNACES
Take note that this furnace operates like an EPA wood burning stove. This applies to the lighting, the ember bed,
and the minimum combustion air intake which was determined based on the use of good seasoned cordwood.
The Max Caddy furnace was tested in spirit of the CSA B415.1-00 Standard.
To optimize the efficiency of your furnace, here is some advice that you should follow when installing or operating
your Max Caddy.
Respect the local codes (when in doubt, consult your local dealer);
Make sure your furnace is installed according to the instructions on the certification label;
All controls and adjustments must be performed by a qualified technician. The blower speed must conform
to the recommendations of local codes and should respect the static pressure ranges in the warm air
plenum of the furnace.
1. CHIMNEY AND DRAFT
This furnace must be connected to a chimney certified for use with wood burning heating appliances. A 7-inch
chimney and connector are recommended for the Max Caddy if it is used as a wood-oil unit or a wood-oil-electric
unit. If an oil option may be installed in the future, we also recommend a 7-inch chimney. If the furnace is to be
used as a wood only unit, then a 6-inch chimney is recommended.
The unit is not to be connected to a chimney flue serving another appliance.
If the chimney draft exceeds 0.06 IN.W.C., a barometric draft control should be installed on the smoke pipe. Never
install a manual damper.
The barometric control must be adjusted so that the maximum draft measured at the furnace outlet does not exceed
-0.06 IN.W.C. Please note that a draft exceeding 0.06 IN.W.C. will reduce the efficiency and could produce an
uncontrollable fire. On the other hand, the minimum draft required is 0.04 IN.W.C. in the evacuation pipe on
the wood side, no matter what type of furnace (WOOD, WOOD / ELECTRIC OR WOOD / OIL).
The adjustment should in no case be modified to increase combustion.
2. SAFETY RULES
GENERAL REQUIREMENTS
Make sure the chimney outlet and the pipes are clean and in good condition.
DO NOT USE CHEMICAL PRODUCTS OR LIQUIDS TO LIGHT THE FIRE.
Do not burn wood coated with paint, glue or chemical products.
DO NOT BURN WASTES OR FLAMMABLE LIQUIDS SUCH AS GASOLINE, NAPHTHA, MOTOR OIL, OR
OTHER UNSUITABLE MATTERS.
Do not install an automatic feeder on this furnace.
Do not store wood in the vicinity of the furnace. Respect the required clearances between combustible materials
and the source of heat.
5
ODOUR FROM THE PAINT
It is normal that smoke and odours emanate from the unit when you first light it. It is recommended to burn it at high
rate and ventilate the building until the odours disappear. The smoke is not toxic.
ASH DISPOSAL
Ashes must be placed in a metal container with a tight fitting lid. The container should be stored outdoors, well away
from combustible materials. This container should not receive any other type of waste. If the ashes are meant to be
buried in soil, wait until all embers have thoroughly cooled before burying.
CREOSOTE BUILD-UP AND REMOVAL
When wood is burned slowly, it produces tar and other organic vapours which, when combined with moisture, form
creosote. The creosote vapours condensate in a relatively cool chimney flue. As a result, creosote residues
accumulate inside the flue lining and the exchangers.
N.B.: To minimize the frequency of the chimney cleaning, buy your firewood at least one year before using it. Store
it in a dry place in order to obtain the minimum moisture rate and optimize the efficiency. Do not store wood or
combustible materials within the installation minimum clearances or the space required to reload the appliance and
remove ashes.
When ignited, creosote produces an extremely hot fire inside the chimney.
In the first year of use, in order to avoid chimney fires, inspect the chimney system at regular intervals to determine a
cleaning cycle. Depending on the type of wood used and its quality, a semi-annual cleaning may be required. A
yearly cleaning is mandatory.
If a significant layer of creosote has accumulated, it must be removed immediately to eliminate the risk of
chimney fire.
Remember that a small, hot fire is preferable to a large smouldering one to prevent creosote build-ups within the
system. Prepare an emergency procedure in case of a chimney fire.
It is recommended to clean the heat exchangers thoroughly at the end of season in order to prevent
corrosion.
W A R N I N G
-THE ASH DRAWER AND EXCHANGERS ACCESS PANEL GET VERY HOT.
-DO NOT MANIPULATE WITH BARE HANDS.
6
SMOKE DETECTOR
We highly recommend the use of a smoke detector. It must be installed at least 15 feet (4,57 m) from the appliance
in order to prevent undue triggering of the detector when reloading.
DOOR GLASS
To maintain a clean and safe installation, do not build your fire too close to the glass or allow logs to lean on the
glass.
Do not operate your furnace at too low a setting. Keep the air inlet opened long enough during the fire start-up to
prevent the fire from smouldering, which could stain the glass.
An intense fire will help keep the glass clean. However, in the event that your glass gets stained, which should not
occur under normal operating conditions, you will have to clean it using a wet cloth and a fireplace glass cleaner.
Clean the glass ONLY when the unit has cooled down. Do not use abrasive cleanser. Fireplace glass cleaners are
available in most home centers and specialty hearth retailers.
WARNING: Avoid knocking or scratching the glass. I could crack or break.
GLASS SPECIFICATIONS
The glass is made of 3/16” (5mm) thick Pyroceram.
Do not operate your wood furnace with a broken glass, as this could seriously damage your furnace.
You can purchase a replacement glass from your PSG dealer.
ASH DRAWER
Your furnace is equipped with an ash drawer to collect ashes produced by the combustion of wood. This drawer
must not be left open during combustion as this may cause over firing and serious damages to the furnace.
The drawer must be emptied regularly.
ASH GRATE
You must replace the ash grate if it is damaged and a replacement may be obtained from your dealer.
It is important that the door and the ash drawer be kept closed while the appliance is in use.
Maintain all gaskets in good condition; in case of deterioration, contact your dealer for a genuine
replacement gasket.
7
3. APPLIANCE INSTALLATION
UNIT LOCATION
The furnace must be installed where outside air supply is sufficient for proper combustion. In airtight houses, it
might be necessary to install an outside air intake. If needed, install
BLOWER INSTALLATION AT THE BACK OF THE UNIT
Once the cold air return box configuration is chosen (cold air ducting support located on top, at the right or at the left
of the cold air return box or the top cold air plenum option)
insert the bend on the bottom of the blower box inside the
opening at the back of the furnace. Slide the edges of the blower box on each side of the furnace’s side panels to
align the holes. Secure it using fastening screws. Use elevator bolts if needed.
PC BOARD INSTALLATION
The PC board can be installed on either side of the furnace. Remove the 4 screws secured on the side of the
furnace where you wish to install the PC board (keep these screws). Remove the lid of the PC board. Secure the PC
board where you removed the screws from the furnace. Once the electrical connections are made on the PC board,
screw the lid back on the PC board.
The furnace must be positioned so that the connector is as short as possible; minimize the use of 90
o
elbows.
The owner must ensure a proper installation to allow for a safe operation of the appliance.
8
CLEARANCES TO COMBUSTIBLE MATERIALS
3/4"
HEAT SHIELD
24"
LEFT WALL
24" IF
UH-MAX
CADDY
72"
1"
24"
HOT AIR PLENUM
8" MIN
6"
STATIC
PRESSURE
CHECK POINT
MIN 0.20" W.C.
18"
45° ELBOW
18"
CEILING
3/4"
HEAT SHIELD
6"
24"
N.B. THE SIZE OF THE AIR RETURN DUCT SHOULD BE AT LEAST EQUAL TO THE SIZE OF THE COLD AIR
PLENUM OPENING.
FIRST 6 FEET OF DUCT INCLUDING WARM AIR PLENUM
*6 in.(150 mm) with a shield at ¾”
PLENUM AFTER THE FIRST 6 FEET
1 in. (25 mm)
REAR (INCLUDING CLEARANCE FOR MAINTENANCE)
24 in. (610 mm)
SIDES (INCLUDING CLEARANCE FOR MAINTENANCE)
24 in.(610 mm)
OIL BURNING UNIT FLUE PIPE
9 in.(230 mm)
WOOD BURNING FURNACE FLUE PIPE
18 in.(455 mm)
** FLOOR
0 in.(0 mm)
* Supplied with the furnace.
**The furnace can be installed on a combustible floor. The us of a floor protector exceeding the furnace by 8
inches on the sides and 18 inches in front is highly recommended.
N.B. This appliance must be installed according to the instructions on the unit’s certification label.
9
FLUE AND BAROMETRIC DRAFT CONTROL CONNECTION
Before connecting the stove pipe, make sure you have removed any accessory from
the flue pipe such as the scraper, shovel, and the poker.
The flue outlet on the Max Caddy furnace is 6” in diameter and the wood only or wood/electric models may be
installed with a 6” chimney approved for use with wood burning heating appliances (2100°F). However, we
recommend the use of a 7” chimney if the retrofit to a wood/oil configuration is probable. In that case, a 6” to 7”
reducer must be installed at the flue outlet of the furnace. If the draft exceeds 0.06 IN.W.C., a barometric control
must installed. Never install a manual damper. Secure the exhaust pipe to the flue adapter with three screws.
For a proper installation, follow the advice below:
1. All the exhaust pipe joints must be secured with three screws. Make sure that each screw goes through the
inner wall of both connectors (male and female). See pictures below showing a male-female coupling.
2. A minimum rise of ¼” per horizontal foot must be respected.
PROPER INSTALLATION IMPROPER INSTALLATION
CAUSES RESTRICTION
WOODONLY
Diameter 6"
WOOD/OIL
Reduce
r
7" to 6"
Diameter 7"
Unit oil
Max Caddy pipe
FLUE
ADAPTER
OIL UNIT’S
OUTLET
10
DAMPER
If the draft exceeds 0.06 INW.C., a barometric damper must installed. The barometric damper must be adjusted so
that the maximum draft measured at the furnace outlet is limited to 0.06 IN.W.C. Please note that a draft higher than
0.06 IN.W.C. will reduce efficiency and could result in an uncontrollable fire. On the other hand, the minimum
draft to be respected is 0.04 IN.W.C. in the evacuation pipe on the solid fuel side, no matter what type of
furnace is use (WOOD, WOOD/ELECTRIC, WOOD/OIL, or WOOD/OIL/ELECTRIC).
COMBUSTION AIR
When the furnace and the chimney are completely cold, it may be necessary to provide fresh air by opening a door
or a window for a few minutes while lighting the fire.
Take note that a house constructed or renovated in order to be airtight may lack the volume of fresh air necessary
for the proper combustion of a solid-fuel heating appliance.
In such a case, when starting up the fire, do not operate appliances that evacuate air outside the house, such as:
- Range hood
- Air exchanger
- Clothes dryer
- Bathroom fan
- Ventilated central vacuum system
A fresh air supply may be necessary to prevent solid fuel units from rejecting products of combustion into the house.
The indications used to determine if an additional fresh air supply is necessary are not appropriate for all the
situations. When in doubt, it is recommended to install a fresh air supply.
A fresh air supply may be needed if:
- Solid fuel units present anomalies, such as irregular draft, smoke return, bad combustion, and/or
reversed draft (whether there is combustion or not);
- Existing solid fuel units such as a stove or fireplace release odours, heat badly, cause smoke returns, or
reversed draft (whether there is combustion or not );
- The opening of a window, even slightly, in calm weather (windless), eliminates every problem mentioned
above ;
- The house is equipped with a tight vapour barrier and adjusted windows, and/or is equipped with an
interior air mechanical evacuation device ;
- There is excessive condensation on the windows in winter; and
- The house is equipped with a ventilation system.
If, according to these symptoms or other similar ones, there is insufficient combustion air, it is necessary to ensure
an additional combustion air supply.
Additional combustion air can be provided following the following methods, provided that they satisfy chapter 4 of the
CSA B365 standard for Canada:
Direct connection: solid fuel units can be connected directly to a source of new combustion air only if they
are certified for this kind of installation, which must respect the manufacturer’s instructions. The MAX Caddy
can be installed with an optional sealed fresh air kit that has been tested with the unit. Consult your dealer.
Indirect method: new combustion air can be brought into a pipe located within approximately 300mm (12
inches) of the unit. If the pipe is too close to the furnace, it may interfere with its operation.
Mechanical ventilation system: if the house is equipped with a ventilation system (air exchanger or heat
recovery), the ventilation system may provide sufficient auxiliary air to the solid fuel unit. Otherwise, the
owner should be informed that the ventilation system may have to be rebalanced by a ventilation technician
after the installation of the solid fuel unit.
11
NOTE:
It is recommended to install an outside air inlet with a diameter of at least 4 inches in the room where the heating
appliance is installed (see drawing below). It is preferable to choose a wall which is not exposed to dominant winds,
depending on the conditions surrounding your house.
N.B. The owner of the furnace is responsible for the room’s air quality in case of negative pressure or
temporary negative pressure.
Insulated pipe (full length)
Fresh air
intake
Exterior
w
all
Free air
entr
y
12
Parallel Installation
The installation of the Max Caddy with another furnace using the same ductwork is not allowed in Canada. This
type of installation is only allowed in the United States. Ideally, the maximum BTU input of the existing oil, gas,
or electric furnace should be equal or higher than the maximum BTU input of the wood furnace. It is mandatory to
respect minimum clearances between the ductwork and combustible material as if the wood furnace was installed as
a standalone unit. The ductwork and furnace should be adjusted in order to reach a static pressure of at least 0.20
IN.WC, but not more than 0.50 IN.WC. A back-flow damper should be installed in the plenum. The back-flow damper
assures that when either unit is operated by itself, the hot air will flow into the home, and not back through the other
furnace. Depending on your installation (see figures examples below), a back-flow damper may be required in each
plenum.
13
ELECTRICAL CONNECTIONS
The following instructions do not supersede the local code.
MAX CADDY-WOOD ONLY
On the Max Caddy, a RTD (resistance temperature detector) is installed on the side of the hot air plenum with the
support provided (two holes are pre-drilled on the edge of the furnace), and connected to the PC board. The RTD is
a sensor (probe type) that reads the temperature inside the hot air plenum.
Then, Install the damper motor on the right hand side of the front of the unit, above the door (use the pre-drilled
holes). The chain that links the air inlet damper to the motor must have a play of 1/8”and must be secured in place
by the hook. When there is no call for heat, the air inlet damper must be completely closed and the chain must be
hooked to the servo-motor at the “8 o’clock” position.
RTD
RTD SUPPORT
TWO HOLES
PRE-DRILLE
D
It is important that the RTD and its support be properly fixed onto the ducting system at the right location.
WARNING: USE WIRING SUITABLE FOR 75
O
C (not supplied)
DAMPER MOTOR
14
MAX CADDY WOOD/ELECTRIC
The high limit control is a manual reset thermostatic sensor that is located inside the electrical unit. The electric unit
must be connected as shown on the diagram (see WIRING DIAGRAM). Install the RTD control on the support
provided, at the determined location (see diagram in previous section). The connections must conform to the
diagram.
Install the damper motor on the right hand side of the front of the unit (see picture in previous section), above the
door (use the pre-drilled holes). The chain that links the air inlet damper to the motor must have a play of 1/8”.
When there is no call for heat, the air inlet damper must be completely closed and the chain must be hooked to the
servo-motor at the “8 o’clock” position.
WARNING: USE WIRING SUITABLE FOR 75
O
C
ELECTRICAL ELEMENT (MAX CADDY WOOD / ELECTRIC)
The WOOD / ELECTRIC combination model uses two thermostats: one thermostat controls the electric heating, and
the other one controls the wood heating. With this system, the electric heating has priority over the wood heating.
When the thermostat activates the electric heating, the air inlet damper closes down (if opened), the blower starts,
and the electric elements are successively activated per block of 5 kW. When the call for electric heating is
satisfied, the wood system will take over if the starting point of the wood system thermostat is superior to that of the
electric system. Therefore, under normal wood-electric combination use, you should set the wood system thermostat
2
o
to 4
o
higher than the electric system thermostat. The bigger the gap, the more the wood heating will contribute to
the overall heating needs.
If the temperature of the electric unit exceeds the high limit , the thermostatic sensor will disengage the elements.
To reactivate, press the red “manual reset” button on the thermostatic sensor ( L-170 Thermodisc) after finding and
fixing the problem that has caused the unit to overheat (static pressure too high, fan breakdown, etc.)
INSIDE VIEW OF THE ELECTRIC ELEMENT
L-170 Thermodisc
RESET
Red button
manual reset
15
THERMOSTAT
Wood furnace only
The thermostat must be installed on an inside wall and located where it is not likely to be affected by the draft
coming from an air outlet. It must be installed at a minimum of 55 inches above the floor.
Combination wood-electric or wood-oil furnace
The combination model uses two thermostats which must be located at the same height from the floor. When the
main thermostat (wood) calls for heat and the demand cannot be satisfied by the furnace with wood as a
combustible, the option (oil burner or electric unit) will take over and maintain the house at the temperature
programmed on the second thermostat (option). If the thermostats use a dry contact, hook-up the main thermostat
(wood) to the WOOD MECH
port on the PC board and the option’s thermostat to the USER MECH port. If the
thermostats send a 24 volt signal to the appliance, hook-up the main thermostat (wood) to the WOOD 24V port on
the PC board and the option’s thermostat to the USER 24V
port.
TRIO furnace (wood-oil-electric or wood-electric-oil )
The trio model also uses two thermostats which must be located at the same height from the floor. When the main
thermostat (wood) calls for heat and the demand cannot be satisfied by the furnace with wood as a combustible, the
first option will take over and maintain the house at the temperature programmed on the second thermostat (option).
Should the first option be unable to satisfy the call for heat, the second option will take over and maintain the house
at the temperature programmed on the second thermostat (option). If the thermostats use a dry contact, hook-up the
main thermostat (wood) to the WOOD MECH
port on the PC board and the option’s thermostat to the USER MECH
port. If the thermostats send a 24 volt signal to the appliance, hook-up the main thermostat (wood) to the WOOD
24V
port on the PC board and the option’s thermostat to the USER 24V port.
FAN CONTROL
We recommend that the HEAT mode be programmed for the MAX Caddy. Under the HEAT mode, the distribution
blower uses various speeds that are controlled by the PC board based on the hot air plenum temperature. The
plenum temperature is read by the RTD temperature probe. The manufacturer’s programmed settings should
provide the most efficient operation for a majority of installations. The PC board also has a manual mode (“MANU” –
consult the MODES section of this manual). Under the manual mode, the MAX Caddy operates as a conventional
furnace. That is, the distribution blower starts at the speed programmed in the PC board (one single speed) based
on only one temperature point read by the RTD probe inside the hot air plenum.
The adjustment of all controls must be performed by a qualified technician. In order to obtain a continuous air
circulation during summer, you simply need to change the PC board mode to “CIRC”. To do so, consult the
MODES section of this manual.
It is not recommended to let the blower run on the continuous mode when heating with wood since the
wood furnace must reach a certain temperature before the blower starts in order to operate efficiently.
DOMESTIC WATER PRE-HEATING OPTION
A water heating loop option is also available to pre-heat domestic water using the energy produced by the Max
Caddy wood furnace. This water loop kit will be inserted between the wood combustion chamber and the heat
exchangers. When heating with wood, the heat from the furnace will pre-heat domestic water that will be stored in a
feed tank before entering your existing water heater. Removable panels are installed on both sides of the furnace for
quick and easy installation of the loop. A 24 volt solenoid valve must be installed at the inlet of the loop and must be
connected to the WATR SOLN
terminal on the PC board; when the plenum temperature reaches 140°F, the valve
opens to allow water circulation. It closes when the temperature drops below 120°F to prevent overcooling the
combustion chamber during low firing rates.
16
The WATR SOLN terminal may also be used to activate the 24 volt relay of a humidifier installed in the system
which, when connected to the PC Board, will be activated and deactivated at the same temperatures as the water
solenoid valve (140°F et 120°F).
COMPLETE INSTALLATION AND OPERATION INSTRUCTIONS FOR THE HOT WATER LOOP KIT ARE
SUPPLIED WITH THE KIT AND CAN BE DOWNLOADED FROM THE PSG WEB SITE AT WWW.PSG-
DISTRIBUTION.COM.
INSTALLATION OF AN AIR CONDITIONING UNIT
The MAX Caddy wood furnace has been tested with an optional air conditioning unit. If this option is chosen, we
recommend an installation as per the graphic provided below. This installation will provide the most efficient and
safe operation of the air conditioning unit using the distribution blower of the MAX Caddy furnace during summer. In
order to complete the installation of an air conditioning unit, the main thermostat must be a “heat/cool” type.
Furthermore, the PC board of the furnace must be in a COOL mode and the desired distribution blower speed must
be programmed (see MODES section for complete instructions). It must be noted that upon thermostatic demand
for cooling, the distribution blower will start immediately.
The capacity and characteristics of the air conditioning unit that has been tested with the MAX Caddy are stated
below. The use of another brand with similar capacity and characteristics is adequate.
Condenser brand: Goodman GSX13048
Capacity: 4 ton
Coil type: Type A, CAUF uncased indoor coil.
A/C coil
Damper
Damper
Recommended Installation
17
4. OPERATING INSTRUCTIONS
PC BOARD (CONTROL SYSTEM)
On the Max Caddy furnace, a new electronic control was developed. This system is more polyvalent. All connections
are done from the PC board. There are connector ports available for all components and options. Under the HEAT
mode, a logic was developed to provide you with the best comfort and efficiency; when you are heating with wood,
the distribution blower starts at speed #1 based on a preselected temperature programmed into the PC board (this
temperature is called the KIP – Kick-in Point). The temperature is read by the RTD probe located inside the hot air
plenum. As the temperature continues to rise inside the hot air plenum, the PC board changes the speed of the
blower to speed #2. This speed should maintain the most efficient temperature (BEP – Best Efficiency Point) inside
the hot air plenum. The BEP has been set at 160F by the manufacturer when wood supplies the energy required for
heat. If the optional oil burner or electrical unit provide the heat, the BEP is set at 150F. Whenever the temperature
inside the hot air plenum continues to rise above the BEP, the PC board selects a higher speed in order to stabilize
the temperature into the ducting system and therefore maintain the BEP.
In the case of the electrical or oil option, the blower starts as soon as that there is a request for heat from the
option’s thermostat. In other words, for security reasons, the distribution blower does not wait for a minimum
temperature to be reached inside the hot air plenum before starting. However, the rest of the logic remains the
same. That is, for as long as there is a heat demand, the PC board will vary the distribution blower’s speed in order
to maintain the BEP inside the hot air plenum.
FIRST USE – GENERAL INFORMATION
The RTD probe reads the temperature inside the hot air plenum and plays the same role as a mechanical fan limit
control found on most conventional wood furnaces. The main difference is that the RTD is connected to a PC board.
It is an electronic fan limit. First, you must configure your PC board. In order to do so, it is important to know which
options are installed on your furnace. During the start-up, the PC board will display some information such as the
name of the company, the version of the program, as well as a four-digit number corresponding to the default
configuration of the furnace.
FIRST USE - SETTTINGS
Using the arrows, you must select the four-digit number corresponding to your installation as per the table below
When your selection is made, push the SELECT button in order to save your setting. Should you need to change
this selection, unplug the electrical power and put it back on. Maintain the MODE button pressed for a few seconds.
You will then be able to select the option corresponding to you installation.
18
Table 1 - Configuration
1 1 1 1 Wood only
2 2 2 2 Wood-oil combo
3 3 3 3 Wood-electric combo
4 4 4 4 Trio: wood followed by oil and electricity
5 5 5 5 Trio: wood followed by electricity and oil
6 6 6 6 Bi-energy
The use of the “BI-ENERGY” function
The bi-energy function is used when a local utility company (Hydro-Quebec for instance) offers a bi-energy program
under which a preferential rate is given, provided that the appliance is equipped with an electronic control that
guaranties the use of a particular source of energy (ex: electricity) based on a given criterion (ex: the outdoor
temperature).
When the MAX Caddy is programmed for bi-energy, a temperature sensor (normally open contact) is connected to
the PC board (see electric diagram – “BIENERGY” port). The contact remains open for as long as the outside
temperature is above a certain value (this reference value is programmed into the system provided by the utility
company). As long as the contact remains open, the electrical unit supplies the heat when the wood is not able to
satisfy the thermostatic demand. If, however, the outside temperature reaches a level below the reference value,
the contact closes and the oil unit is used as the option for heat if the wood is not able to satisfy the thermostatic
demand.
MODES, OPTIONS, AND PROGRAMMING
Your PC board is equipped with four operating modes : HEAT (automatic heating), COOL (air conditioning), CIRC
(recirculation), and MANU (manual heating). You can pass from one mode to the other by pressing on the arrows
buttons. For each mode, some selections are available. A definition is provided below (see : “The Selections”).
The speeds
Your furnace is equipped with a 4-speed blower. Using the PC board, we have created 6 functional speeds. Refer to
Table 2 below for the various speed configurations.
Table 2 – The Speeds
Speed
Corresponding data CFM* Static pressure
1 Blower speed #1 using 98V 600 0.2’’ H2O
2 Blower speed #1 using 115V 760 0.2’’ H2O
3 Blower speed #2 using 98V 840 0.2’’ H2O
4 Blower speed #2 using 115V 950 0.2’’ H2O
5 Blower speed #3 using 115V 1150 0.2’’ H2O
6 Blower speed #4 using 115V 1260 0.2’’ H2O
*These results were measured at exit of plenum during laboratory tests. Results may vary depending of
the configuration and installation.
19
System Balancing
It is important to call upon a professional installer for the installation of the furnace and the ducting system
configuration. Certain check-ups must be performed and certain rules must be respected in order not to damage the
blower. When all components are installed on the furnace and the ducting system is connected to the various rooms
of the house, you must balance the ducting system. In order to do so, start the furnace blower by selecting the
recirculation mode (CIRC). Then, in the FAN section, use the arrows to select speed #4 (refer to Table 2). It is
important to respect the velocity in the main duct, the secondary ducts, as well as the velocity at the room outlets.
The static pressure of your system must be adjusted to at least 0.2 IN.W.C. and must not exceed 0.5 IN.W.C.
Finally, make sure that you never exceed the maximum blower motor full load amperage.
HEAT Mode (automatic heating)
Operation
When the temperature in your house is below the value at which your wall thermostat is programmed, a signal is
sent to your furnace through the PC board, activating the motorized damper located in front of the furnace and thus
allowing more oxygen to the fire. The RTD temperature probe, located inside the hot air plenum of your furnace,
reads the plenum temperature continuously. When the temperature reaches the start-up value selected by the user
(KIP – Kick-in Point), the distribution blower starts functioning at the minimum speed. Thereafter, the blower
increments its speed until it reaches the best efficiency point (BEP) determined by the manufacturer. If the
temperature inside the hot air plenum exceeds the limit determined by the manufacturer, the blower automatically
selects the maximal speed and the motorized damper closes in order to slow down combustion. When the
temperature returns to a safe level, the blower speed gradually returns to the speed required to maintain the BEP.
Programming
Make sure that your wall thermostat is well connected to the PC board. Make sure that the right port has been
selected based on the type of thermostat (e.g. 24VAC or Millivolt).
In the MODE menu, select HEAT by pushing the SELECT button. Then, using the arrows buttons, choose from the
different selections: KIP, TEMP, or UNIT. Consult the “Selections” section in order to obtain a complete definition
of the terms KIP, TEMP, and UNIT.
When your choice is made, press SELECT. Then, use the arrows to make the appropriate adjustment. Press
SELECT to memorize your adjustment. To change the selection ( KIP, TEMP, or UNIT) push an arrow button. To
go back to the main menu (HEAT, COOL, CIRC, MANU), push on the MODE button. After two minutes of inactivity
on the keyboard, the display will shut itself off.
COOL Mode (air conditioning)
Operation
If an air conditioning unit is installed, the PC board will have to be connected to a dual-function wall thermostat (e.g.
“heat/cool”) in order to synchronize the start of the furnace blower with the start of the air conditioning condenser.
Upon receiving the wall thermostat’s signal, the furnace blower will start functioning at the speed selected by the
user.
Programming
Make sure that your wall thermostat is well connected to the PC board. Make sure that the right port has been
selected based on the type of thermostat (e.g. 24VAC or Millivolt).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47