Draper 130029 Operating instructions

Category
Projection screens
Type
Operating instructions

This manual is also suitable for

Installation/Operating Instructions
Baronet/HW 110V and 220V Electric Projection Screen by Draper
Wall Installation:
Mount screen through holes in back of endcaps as shown. Installer should
furnish appropriate hardware as re quired.
Recessed Installation:
Recess should permit access for removal of screen if necessary. Screen may
be mounted as in sus pend ed or wall installation. Angles may be used (pro-
vided by others).
Electrical Connections
Screen operates on 110-120V AC, 60 Hz./220V AC, 50 Hz. current, depend-
ing on model ordered. Duty Cycle: On 26 seconds/off 3 minutes.
Junction box is located inside left endcap and cover plate is secured to
endcap with two screws. Junction box contains pigtail leads and grounding
screws, per wiring di a gram on reverse.
Screen is shipped with internal wiring complete and control switch(es) fully
boxed. Wire connecting screen to switch(es) and switch(es) to power supply
should be furnished by installer. Connections should be made in ac cor dance
with attached wiring diagram, and wiring should comply with National and
local electrical codes.
All operating switches should be “off before power is con nect ed. Do NOT wire
motors in parallel.
Hanging Screen
General:
When locating view ing surface and checking clear ance for screen’s op er a-
tion, remember surface is centered in case. Handle case care ful ly to protect
its fi nish.
Regardless of mounting method, screen should be positively and securely
sup port ed so that vibration or even abusive pulling on the viewing surface will
not cause case to work loose or fall. Installer must insure that fas ten ers used
are of adequate strength and suit able for mounting sur face cho sen.
Suspended Installation:
Suspend screens from holes in top of endcaps as shown. "S" hooks, chains
(or cable) and turn buck les should be pro vid ed by installer. “S” hooks should
go through the front holes on the endcaps (see drawing below), and both
ends of the “S” hooks should be crimped for additional safety. Chains should
be at tached to beams or other struc tur al mem bers. Turn buck les should be
adjusted so screen hangs level.
If you encounter any diffi culties installing or ser vic ing your Bar on et/HW screen, call your
dealer or contact Draper, Inc., Spiceland, In di ana, +1 765-987-7999 or fax +1 765-987-1689.
Copyright © 2010 Draper Inc. Form BaronetHW_Inst10 Printed in U.S.A.
Caution
Read instructions through completely before proceeding.
Follow instructions carefully. Installation con trary to instructions in val i-
dates warranty.
Screen should be accessible for complete removal should fabric be-
come damaged or should other ser vice be required.
Screen should be installed level (using a carpenter’s level).
Nothing should be fastened to screen dowel or viewing surface.
Operating switch(es) packed separately in screen carton. Do not dis-
card with packing material.
Screen operates on 110-120V AC, 60 Hz. or 220V AC, 50 Hz. current,
depending on model ordered.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
Operation
Before operating screen remove tape securing fabric and dowel to roller. If
viewing surface hangs out of case 8" or 9" (20-23 cm), tape has prob a bly
been bro ken by rough handling in ship ment, allowing surface to “un wrap”
one turn about the roller. Manually wrap fabric back around the roller without
turning the roller itself.
110-120V/220V Single Station Control — 3-position up-off-down switch
per mits operation to be stopped at any point. Factory adjusted limit
switches au to mat i cal ly stop screen when fully down or fully up. 220V version
is CE certifi ed.
110-120V/220V Multiple Station Control—Switches are similar in ap-
pear ance to 110V/220V Single Station Control. Screen stops when switch
is re leased and may be re start ed in either direction. Factory adjusted limit
switch es stop screen automatically when fully up or fully down.
24V Control — Three-button up-stop-down switch es stop at any point de-
sired, operate in any sequence. Factory adjusted limit switches au to mat i cal ly
stop screen when fully up or fully down.
Key Operated Switching — Two kinds of key-operated switches are op tion-
al ly available with this unit.
The key-operated power sup ply switch controls power to the screen and
switches. When it is “off”, the switch es will not operate screen. Key may
be re moved from the switch in either “on” or “off” position.
A three-po si tion key switch per mits the screen to be operated directly by
key. In this case, the screen’s operator must always have a key.
RS232/Ethernet—Serial communication and network communication
optionally available with wall switches, RF or IR remote.
Adjustments
Screen has been factory set and should not normally require further
adjustment. However, if you desire to change the “up” and “down” stopping
positions, proceed as follows:
“Down” limit switch: Down stopping position can be adjusted by turning
white knob with a screw driver or hex wrench. Turning knob counterclockwise
will allow viewing surface to run farther down. Turning it clockwise will reduce
the amount of exposed viewing surface.
“Up” limit switch: Up stopping position can be adjusted by turning red knob
with a screw driver or hex wrench through the small grommet. Turning knob
counterclockwise will allow surface to run farther into screen case. Turning it
clockwise will allow viewing surface to stop farther out of screen case.
CAUTION: Be sure all switches are in “off” position before adjusting
limit switches. Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
®
Minimum 5 cm wide
slot for passage of
viewing surface if
suspended above ceiling
Example of
suspension
above ceiling.
Ceiling tile
and grid
(by others)
Back hole for wall mounting.
Hardware by others.
Top Hole for
suspended mounting.
Hardware by others.
Mounting angle
and hardware
by others.
Suggested for
recessed
installations.
Crimp
Crimp
These Installation/Operating Instructions are available in the offi cial language
of the country where you purchase the product. Please contact your
distributor to request a copy.
Vous pourriez demander les instructions d’installation et d’opération traduises
dans la langue offi cielle du pays ou vous achetez le produit. Veuillez
demander à votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der
offi ziellen Sprache des Landes, indem Sie das Produkt gekauft haben,
vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.
Baronet/HW 110-120V
AC version is certifi ed by
Underwriters’ Laboratories, Inc.,
for the U.S. and Canada.
Baronet/HW220V AC
version is CE certifi ed.
Baronet/HW by Draper
Page 2 of 2
Fabric width + 5¾" (146 mm)
3¼"
(83 mm)
3¾"
96 mm
Viewing
Surface
3¼"
(83 mm)
Wiring Diagrams
Case Dimensions
www.draperinc.com
(765) 987-799
9
Please Note: Do not wire motors in parallel.
Baronet/HW 220V AC (CE)
Neutral
L1
220v,
50 Hz.
Dashed wiring
by installer
Control
switch
Single Station Control
CE Approved
J
unction box at
eft end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Dashed wiring
by installer
Neutral
Hot
Multiple Station Control
Not CE Approved
Cap off with wire
nut & tape
Red
Red
Red
Blue
Blue
Blue
Black
Black
220v, 50 Hz.
Black
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green (Motor Ground)
Green (Motor Ground)
Baronet/HW 110V AC
Single Station Control
Junction box at
left end of screen
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2-1/8" x 1-7/8" deep
Blue
Black
Red
Location of key
operated on-off
switch if furnished
To 110V AC Line
Multiple Station Control
Junction box at
left end of screen
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2-1/8" x 1-7/8" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110V AC Line
Green (Motor Ground)
Green (Motor Ground)
MC1
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
White or Blue-Common to screen & 110/220V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110/220V AC-Hot
Black-to 110/220V AC-Hot
Green(Ground)
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
Aux Port for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
Dashed wiring by electrician
Low voltage wiring by others
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Location of key
operated on-off
switch if furnished
To
110/220V
Line
Internal
S
creen Wiring
STOP
Control
Switches
24v DC
STOP
Green 110V/
Green/Yellow 220V
(Motor Ground)
Low Voltage, IR Remote or RF Remote (LVC-III)
See separate Serial Communication-RS232 Instruction sheet for
enabling RS232 with the MC1.
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
White or Blue-Common
Red-to Screen (directional)
Black-to Screen (directional)
Brown-Hot to AC
Green/Yellow-Ground
Fuse
Program LED
Eye Port for IR Eye. For RF Receiver or LED
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
Low Voltage Wiring by others
AC Wiring by electrician
MC1
Location of key
operated on-off
switch if furnished
To AC Line
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Internal
S
creen Wiring
Green 110V/
Green/Yellow 220V
(Motor Ground)
3.8 mm (1
1
/2")
3.2 mm (1
1
/4")
8.6 mm
(3
3
/8")
7.8 mm
(3
1
/16")
4.5 mm (1
3
/4")
220V 3-Position, Surface Mount Wall Switch
110-120V 3-Position Wall Switch
UP
DOWN
7 mm (2
3
/
4
")
11.8 mm
(4
1
/
2
")
3"-6" leads
  • Page 1 1
  • Page 2 2

Draper 130029 Operating instructions

Category
Projection screens
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI