Fantec TC-650RVN2 is a 2U redundant power supply with N+1 architecture, providing reliable power for mission-critical applications. It features universal AC input, active power factor correction, and protections against over-power, over-voltage, and short circuits. The front panel LED indicates power status, and power fault alarm signals alert users to any issues. With a 100% burn-in test, this power supply ensures reliability and peace of mind.

Fantec TC-650RVN2 is a 2U redundant power supply with N+1 architecture, providing reliable power for mission-critical applications. It features universal AC input, active power factor correction, and protections against over-power, over-voltage, and short circuits. The front panel LED indicates power status, and power fault alarm signals alert users to any issues. With a 100% burn-in test, this power supply ensures reliability and peace of mind.

TC-650/700
RVN2
2U Type N+1 Redundant Power Supply
Features
Universal AC input/Full range
Active power factor Correction
Protections:Over Power/Over Voltage/Short Circuits
Current Sharing design on +3.3V, +5V and +12V
Front panel LED to Indicate Power Status
Power Fault Alarm Signals
Alarm Reset
100% burn-in test
Electrical Specifications:
Model No.
TC-650/700RVN2
Input Voltage 100~240VAC,±10%
Input Frequency 47Hz ~ 63Hz
Power Factor 0.96@230VAC/50Hz,full load
Output Ratings
+5V
+3.3V
+12V
REMARKS:
Short Circuit Shut down o/p voltage, re-power on to recover
Over Voltage +5V→5.7V~6.5V,+3.3V→3.7V~4.1V,+12V→12.8V~13.9V
1A 32A 1A 32A 5% 1% 50mV
3A 46A 3A 52A 5% 1% 70mV
1A 25A 1A 25A 5% 1% 50mV
1.Total Max output of +5V AND +3.3V not exceed 200W
2.Power module Total output power not exceed 650W for
TC-650RVN2 and 700W for TC-700RVN2.
3.Noise bandwidth is from DC to 20MHz.
-12V 0A 1A 0A 1A 5% 1% 70mV
Output
Voltage
Output Current
Min. Max. Min. Max.
+5VSB 0.1A 3A 0.1A 3A 5% 1% 50mV
Protections
Efficiency 72% Typical at full load
Hold up Time 16m sec. minimum, at full load
Over Power 110% ~ 150% rated output power
Function
Operating Temperature 0°C to 45°C
Power Good Signal 100ms~500ms, TTL compatible signal
Power Fail Delay 1msec. ,TTL compatible signal
PS-ON Power off:PS-ON = 2V min. ;Power on:PS-ON = 0.8V max.
Environmental
Storage Temperature -20°C to +70°C
Operating Humidity 20% to 90%,non-condensing
Storage Humidity 5% to 95%, non-condensing
Safety & EMI/RFI
Others
MTBF 100,000 hours
Coolings 38x38x28mmx4 DC FANS
Safety Standards UL,cUL,TUV,CB
EMI/RFI Standards CISPR22(EN55022) Class B, FCC Part15 Class B
Harmonic EN61000-3-2
Dimension(DxWxH) 300x101x84mm
Input Current 12A For 115VAC, 6A For 230VAC
TC-650RVN2 TC-700RVN2
Regulation
LOAD LINE
Output Ripple &
Noise Max.(p-p)
Input Ratings
300.0
84.0
308.0
314.0
15.5
58.0
38.0
56.5
12.0
37.5
6#-32(X3)
101.0
101.0
111.0
121.0
9.0
9.0
66.083.084.0
0.5
6#-32(x4)
6.0
SING
DATE
REVISIONS
REV
DESCRIPION
MODEL NO
PART NO
mm
OF
DATE
SHEET
DRAW NO
UNITS
DRAW BY
CHECK BYAPPROVE BY
PROJECTION:
MATERIAL
± .2
± .1
± .025
.X=
.XX=
.XXX=
TOLEANCES:
JACKY
2007,7,19
COMPUTER
/ /
SPPC T1.0
TC-650_700RVN2
84.0
5.0
DIMENSION:300(D) x 101(W) x 84(H)mm
15.0
20.0
4.0
4.0
7.0
0.4
20.0
20.0
15.0
19.8
4.0
20.0
4.0
15.0
12.0
6.0
4.0
60.0
24.0
4.0
218.0
12.8
  • Page 1 1
  • Page 2 2

Fantec TC-650RVN2 Specification

Category
Power supply units
Type
Specification
This manual is also suitable for

Fantec TC-650RVN2 is a 2U redundant power supply with N+1 architecture, providing reliable power for mission-critical applications. It features universal AC input, active power factor correction, and protections against over-power, over-voltage, and short circuits. The front panel LED indicates power status, and power fault alarm signals alert users to any issues. With a 100% burn-in test, this power supply ensures reliability and peace of mind.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI