Gefen EXT-DP-441 Specification

  • Hello! I am an AI chatbot trained to assist you with the Gefen EXT-DP-441 Specification. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
®
T
echnical Su
pp
or
t
:
Telephone
(
818
)
772-910
0
(
800
)
545-690
0
Fax
(
818
)
772-912
0
T
echnical Su
pp
ort Hours
:
8
:00 AM to 5:00 PM Monda
y
thru Frida
y
.
Write To
:
G
e
f
en LL
C
o
ustomer
ervic
2
0600
Nordho
ff
S
t
C
hatsworth,
C
A 9131
1
www.
g
e
f
en.com
s
upport
@g
e
f
en.com
Notic
e
G
e
f
en LL
C
reserves the ri
g
ht to make chan
g
es in the hard ware, packa
g
in
g
and
an
y
accompan
y
in
g
doc u men ta tion without prior written notice.
4
x1 Displa
y
Port Switcher is a trademark o
f
G
e
f
en LL
C
©
2011
G
e
f
en LL
C
, All Ri
g
hts Reserve
d
All trademarks are the propert
y
o
f
their respective owners
ASKING FOR ASSISTANC
E
R
ev
A1
CONTENT
S
1 Intr
oduc
ti
on
2
O
peration Notes
3
Features
4 Front Panel La
y
ou
t
5
Front Panel Descriptions
6
Back Panel La
y
ou
t
7 Back Panel Descriptions
8
IR Remote
C
ontrol
U
ni
t
8
La
y
out and Descriptio
n
9
Installin
g
the Batter
y
10
C
on
g
urin
g
the IR Remote
C
ontrol Uni
t
11
C
onnectin
g
the 4x1 Displa
y
Port
S
witcher
11 Wirin
g
Dia
g
ram
12
O
peratin
g
the 4x1 Displa
y
Port
S
witcher
12 Fr
o
nt P
a
n
e
l B
u
tt
o
n
s
a
n
d
LED In
d
i
ca
t
o
r
s
12
S
witchin
g
sources usin
g
the
f
ront-panel buttons
12
S
witchin
g
sources usin
g
the IR Remote
C
ontrol Uni
t
13
S
witchin
g
sources usin
g
R
S
-23
2
13
S
witchin
g
sources usin
g
Telne
t
14 R
S
-2
3
2
C
ontrol
1
5
R
S
-2
3
2
C
ommands
15 IP
C
on
g
uratio
n
2
0
G
eneral
C
ommands
23 Routin
g
and Extender
C
ommands
24 Telnet
C
ontrol
26
S
peci
cations
27 Warrant
y
1
INTRODUCTIO
N
C
on
g
ratulations on
y
our purchase o
f
the 4x1 Displa
y
Port
S
witcher. Your complete
s
atis
f
action is ver
y
important to us.
G
efen
G
e
f
en is a unique product line caterin
g
to the
g
rowin
g
needs
f
or innovative home
theater solutions. We specialize in total inte
g
ration
f
or
y
our home theater, while
also
f
ocusin
g
on
g
oin
g
above and be
y
ond customer expectations to ensure
y
ou
g
et the most
f
rom
y
our hardware. We invite
y
ou to explore our distinct product
l
ine and hope
y
ou
nd
y
our solutions. Don’t see what
y
ou are lookin
g
f
or here
?
Please call us so we can better assist
y
ou with
y
our particular needs.
T
he Gefen 4x1 Displa
y
Port Switcher
Easil
y
switch between
f
our computers usin
g
Displa
y
Port with the 4x1 Displa
y
Port
S
witcher.
The rack-mountable 4x1 Displa
y
Port
S
witcher o
ff
ers an economical solution
f
or
s
witchin
g
between
f
our di
ff
erent computers to one displa
y
location at the touch o
f
a
bu
tt
o
n.
Eliminatin
g
the need to purchase man
y
displa
y
s in a studio or pro
f
essional en-
vironment, this versatile solution saves mone
y
, supports both Mac and P
C
-t
y
pe
c
omputers, and o
ff
ers uncluttered and increased desktop space.
This
S
witcher can be controlled usin
g
f
ront-panel discrete switchin
g
, the included
IR Remote control, or the R
S
-232 port
f
or switchin
g
automation.
The 4x1 Displa
y
Port
S
witcher is compatible with all operatin
g
s
y
stems usin
g
Displa
y
Port.
How It Works
C
onnect
f
our 6-
f
oot Displa
y
Port cables between the computers and the
S
witcher
inputs.
C
onnect the
S
witcher output to the monitor usin
g
a Displa
y
Port cable.
C
onnect the included 5V D
C
lockin
g
power suppl
y
to the 4x1
S
witcher and con-
n
ect the A
C
power cord to an available electrical outlet. The currentl
y
selected
s
ource will be displa
y
ed.
READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE 4X1 DISPLAYPORT SWITCHER
The 4x1 Displa
y
Port
S
witcher supports Pass-throu
g
h EDID. The
S
witcher
will use the EDID
f
rom the currentl
y
active input.
Dual Link resolutions up to 2560 x 1600 are supported.
H
D
C
P content is not supported.
• This
S
witcher does not support DH
C
P.
• The de
f
ault IR channel
f
or both the
S
witcher and the IR Remote
C
ontrol
U
ni
t
is channel 0.
S
ee pa
g
e 10
f
or more in
f
ormation.
OPERATION NOTE
S
2
3
FEATURE
S
Features
S
witches a sin
g
le Hi-De
f
displa
y
between
f
our Displa
y
Port-equipped
sources
.
S
upports HD resolutions up to 1080p Full HD
S
upports VE
S
A resolutions up to 2560 x 160
0
S
upports R
G
B and Y
C
b
C
r color spaces
RS
-2
3
2 control
• IR r
e
m
o
t
e
co
ntr
o
l
J
ack
f
or external IR Receiver
S
aves space on
y
our deskto
p
Rac
k-m
ou
nt
ab
l
e
P
acka
g
e Includes
(
1
)
4x1 Displa
y
Port
S
witcher
(
1
)
IR Remote
C
ontrol Uni
t
(
1
)
5V D
C
Lockin
g
Power
S
uppl
y
(
1
)
S
et o
f
Rack Ears
(
1
)
User Manual
4
FRONT PANEL LAYOU
T
Front Panel
4
2
1
3
5
FRONT PANEL DESCRIPTION
S
1
Input Indicators
(
1 - 4
)
Each o
f
these LED indicators
g
lows bri
g
ht blue accordin
g
to the input selection
(
see
I
nput Button
s
, below
)
2
I
R
R
eceives IR si
g
nals
f
rom the included IR Remote
C
ontrol Unit.
3
Input Buttons
(
1 - 4
)
Pressin
g
each o
f
these buttons selects the desired input source
(
1-4
)
.
4 Powe
r
This LED indicator will
g
low bri
g
ht red when the unit is powered.
6
BACK PANEL LAYOU
T
Back Panel
6
2
3
5
4
1
7
BACK PANEL DESCRIPTION
S
1
5V D
C
C
onnect the included 5V D
C
lockin
g
power suppl
y
to this receptacle.
2
In
1
- In
4
Each o
f
these ports will accept a standard Displa
y
Port source device.
3
DP Ou
t
This port will accept a sin
g
le standard Displa
y
Port output device. The currentl
y
s
elected Displa
y
Port input source will be output via this port.
4 Ext I
R
C
onnect an IR extender cable to this port.
5 RS-232 Serial Por
t
This port is used
f
or serial communication usin
g
an R
S
-232 control device. For
details, re
f
er to pa
g
e 14.
6
Etherne
t
C
onnect the
S
witcher to a network in order to communicate via Telnet.
IR REMOTE CONTROL UNI
T
8
2
1
Activity Indicato
r
This LED will be activated momentaril
y
each time a button is pressed.
2
S
ource Selection Buttons
(
1 - 4
)
Th
ese
bu
tt
o
n
s
a
r
e
used
t
o
se
l
ec
t whi
c
h
sou
r
ce
i
s
r
ou
t
ed
t
o
a
m
o
nit
o
r.
L
a
y
out and Description
1
NOTE: An Activit
y
Indictor that
ashes quickl
y
while holdin
g
down
an
y
one o
f
the
f
our buttons indicates a low batter
y
. Replace th
e
IR Remote
C
ontrol batter
y
as soon as possible.
IR REMOTE CONTROL UNI
T
9
Installin
g
the RMT-4IR Batter
y
1.
R
emove the batter
y
cover on the back o
f
the IR Remote
C
ontrol Unit.
2. Insert the included batter
y
into the open batter
y
slot. The positive
(
+
)
side o
f
the batter
y
should be
f
acin
g
up.
3
.
R
eplace the batter
y
cover.
The Remote
C
ontrol unit ships with two batteries.
O
ne batter
y
is required
f
or
operation and the other batter
y
is a spare.
WARNING
:
Risk o
f
explosion i
f
batter
y
is replaced b
y
an
incorrect t
y
pe. Dispose o
f
used batteries accordin
g
to the
in
s
tr
uc
ti
o
n
s
.
Batter
y
S
lo
t
IR REMOTE CONTROL UNI
T
10
C
orresponding DIP
S
witch
S
ettings
f
or each IR
C
hannel
It is important that the IR channel on the Remote
C
ontrol unit, matches the IR
c
hannel set on the 4x1 Displa
y
Port
S
witcher. For example, i
f
both DIP switches
on the IR Remote
C
ontrol unit are set to IR channel 0
(
both DIP switches down
)
,
then the 4x1 Displa
y
Port
S
witcher must also be set to IR channel 0.
S
ee pa
g
e
21 on how to chan
g
e the IR channel on the 4x1 Displa
y
Port
S
witcher.
IR
C
hannel
0
(
de
f
ault
)
1 2
ON
How to Resolve IR Code Con icts
In th
e
e
v
e
nt th
a
t IR
co
mm
a
n
ds
f
r
o
m
o
th
e
r r
e
m
o
t
e
co
ntr
o
l
s
int
e
r
fe
r
e
with th
e
s
upplied IR Remote
C
ontrol unit, chan
g
in
g
the IR Remote
C
ontrol’s IR channel
will
x the problem. The IR Remote
C
ontrol unit has a bank o
f
DIP switches used
f
or settin
g
the IR channel. The DIP switch bank is located underneath the batter
y
co
v
er
.
L
eft: Pi
c
t
u
r
e
of
th
e
opened rear batter
y
c
ompartment o
f
the IR
r
emote showin
g
the
e
xposed DIP
S
witch
ba
nk
be
tw
ee
n th
e
batter
y
chambers.
IR
C
hannel
2
1 2
ON
IR
C
hannel
3
1 2
ON
IR
C
hannel
1
1 2
ON
1 2
CONNECTING THE 4X1 DISPLAYPORT SWITCHER
1
1
How to Connect the 4x1 Displa
y
Port Switcher
1
C
onnect up to
f
our
(
4
)
Displa
y
Port source devices to the Displa
y
Port inputs
on the back panel o
f
the
S
witcher usin
g
Displa
y
Port cables.
2
C
onnect a Displa
y
Port-supported displa
y
to the Displa
y
Port output on the
back panel o
f
the
S
witcher.
a
O
PTI
O
NAL: To use the R
S
-232 communication
f
eature, connect a
n
RS
-2
3
2 cable between the
S
witcher and R
S
-2
3
2 host controller.
b
O
PTI
O
NAL: To communicate with the
S
witcher usin
g
Telnet, connec
t
an Ethernet cable
f
rom the Ethernet
j
ack on the back o
f
the
S
witcher
to the network.
S
ee pa
g
e 24
f
or more in
f
ormation on usin
g
the Telnet
fea
t
u
r
e
.
c
O
PTI
O
NAL: To extend the ran
g
e o
f
the IR control, connect an IR
Extender
(G
e
f
en part no. EXT-RMT-EXTIR
)
to the back o
f
the
S
witcher.
3
C
onnect the included 5V lockin
g
power suppl
y
to the power receptacle on
the 4x1 Displa
y
Port
S
witcher
4
C
onnect the opposite end o
f
the power suppl
y
to an open wall socket power
source
.
Wirin
g
Dia
g
ram for the 4x1 Displa
y
Port Switcher
RS-232 Controller
EXT-DP-441
Computer
Computer
Computer
Computer
DisplayPort Display
DISPLAYPORT CABLE
RS-232 CABLE
DisplayPort Switcher
ATTENTION: This product should alwa
y
s be connected to a
g
rounded electrical socket.
OPERATING THE 4X1 DISPLAYPORT SWITCHER
12
Front Panel Buttons and LED Indicators
The
f
ront panel o
f
the 4x1 Displa
y
Port
S
witcher has a set o
f
f
our
(
4
)
LED
indicators, displa
y
in
g
which input
(
source
)
is bein
g
displa
y
ed. Each o
f
these LED
indicators corresponds to one o
f
the push-buttons on the
f
ront panel.
Switchin
g
sources usin
g
the front-panel buttons
Example:
S
witch to input 3 using the
f
ront-panel buttons
:
1 Press button 3 on the
f
ront panel o
f
the 4x1 Displa
y
Port
S
witcher.
2 The LED indicator
f
or input 3 will
g
low bri
g
ht blue on the
f
ront panel.
Switchin
g
sources usin
g
the IR Remote Control
Example:
S
witch to Input 1 using the IR Remote
C
ontrol
:
1 Press button 1 on the IR Remote
C
ontrol Unit. The Activit
y
Indicator on
the IR Remote
C
ontrol Unit will
g
low
y
ellow, indicatin
g
that a button was
p
ressed.
2 The LED indicator
f
or input 1 will
g
low bri
g
ht blue.
1
2
1
2
1
3
OPERATING THE 4X1 DISPLAYPORT SWITCHER
Switchin
g
sources usin
g
RS-232
C
on
g
ure the
S
witch
f
or use with R
S
-232
(
see pa
g
e 14
f
or details
)
.
Example:
S
witch to input 4 using R
S
-23
2
1
U
se the command
r
4 to route the
S
witcher to Input 4.
S
ee pa
g
e 14 - 15
f
or important in
f
ormation on R
S
-232 commands. R
S
-232 commands are
case
-
se
n
s
itiv
e
.
2 The LED indicator
f
or Input 4 will
g
low bri
g
ht blue on the
f
ront panel.
Switchin
g
sources usin
g
Telne
t
C
on
g
ure the
S
witch
f
or use with Telnet.
S
ee pa
g
e 24
f
or details.
Example:
S
witch to Input 2 using the Telnet protocol
1
U
se the command
r
2
to route the
S
witcher to Input 2.
2 The LED indicator
f
or Input 2 will
g
low bri
g
ht blue.
2
t
erm
i
na
l
rea
d
y..
.
r
4
R
oute to Input 4
1
2
T
ype Cmd: r
2
R
oute to Input
2
1
RS-232 CONTROL
1
4
O
nl
y
pins 2
(
Receive
)
, 3
(
Transmit
)
, and 5
(G
round
)
are used
f
or communication.
A null-modem adapter should not be used with this product.
54321
9876
12345
6789
Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface
Serial Port Settin
g
s
Bits per second ............................................................................................ 19200
Data bits ...............................................................................................................
8
Parit
y
............................................................................................................. Non
e
S
top bits ................................................................................................................
1
Flow
C
ontrol .................................................................................................. Non
e
NOTE
:
O
nl
y
pins 2
(
Receive
)
, 3
(
Transmit
)
, and 5
(G
round
)
are
u
sed
f
or communication. A null-modem adapter should n
ot
be
t
u
sed with this product.
RS-232 COMMAND
S
15
Command S
y
nta
x
All R
S
-2
3
2 commands are case-sensitive and must be entered in lowercase.
Each command must be preceded b
y
the
‘#
character. A carria
g
e return must
also be appended to
every
command.
y
Example
p
:
#
set
_
http
_
port
80
[
CR
]
IP Con
g
uration
Command
D
escri
p
tion
#
get_pas
s
Prompts
f
or the Telnet passwor
d
#
get_user_name Prompts
f
or the Telnet usernam
e
#
ipcon
g Displa
y
s all T
C
P
/
IP settin
g
s
#
rstip
S
ets IP con
g
uration to de
f
ault settin
g
s
#
set_http_por
t
S
ets the Web server listenin
g
por
t
#
set_pas
s
S
ets the Telnet passwor
d
#
set_telnet_por
t
S
ets the Telnet listenin
g
por
t
#
set_user_name
S
ets the Telnet user nam
e
#
sgatewa
y
S
peci
es the new
g
atewa
y
#
sipad
d
S
peci
es a new IP address
#
snetmask
S
peci
es a new net mas
k
#
use_telnet_pas
s
To
gg
les Telnet password promp
t
#
GET_PASS Command
The
#G
ET_PA
SS
command prompts
f
or the Telnet password.
Syntax
y
:
#
get_pas
s
Pa
r
a
m
e
t
e
r
s
:
N
o
n
e
1
6
RS-232 COMMAND
S
#
GET_USER_NAME Command
The
#G
ET_U
S
ER_NAME command prompts
f
or the Telnet username.
Syntax
y
:
#
get_user_nam
e
Pa
r
a
m
e
t
e
r
s
:
N
o
n
e
#
IPCONFIG Command
The
#
IP
CO
NFI
G
command displa
y
s all T
C
P
/
IP settin
g
s.
Syntax
y
:
#
i
p
con
g
Pa
r
a
m
e
t
e
r
s
:
N
o
n
e
#
RSTIP Command
The
#
R
S
TIP command resets the IP con
g
uration to the de
f
ault settin
g
s.
Syntax
y
:
#
rsti
p
Pa
r
a
m
e
t
e
r
s
:
N
o
n
e
17
RS-232 COMMAND
S
#
SET_HTTP_PORT Command
The
#S
ET_HTTP_P
O
RT command sets the Web server listenin
g
port.
Syntax
y
:
#
set_http_port param
1
Pa
r
a
m
e
t
e
r
s
:
p
aram
1
Port [0 - 255]
#
SET_PASS Command
The
#S
ET_PA
SS
command sets Telnet password.
Syntax
y
:
#
set_pass param
1
Pa
r
a
m
e
t
e
r
s
:
p
aram
1
S
trin
g
N
o
t
es
:
The maximum len
g
th o
f
the password strin
g
is 20 characters.
#
SET_TELNET_PORT Command
The
#S
ET_TELNET_P
O
RT command sets the Telnet server listenin
g
port.
Syntax
y
:
#
set_telnet_port param
1
Pa
r
a
m
e
t
e
r
s
:
p
aram
1
Port [0 - 255]
/