Operating and installation instructions
Outer wall fan
fr
Notice de montage et d’utilisation
Ventilateur sur mur extérieur
nl
Gebruiks- en montageaanwijzing
Buitenmuurventilator
it
Istruzioni per l’uso e l’installatione
Ventola murale esterna
es
Instrucciones de uso y montaje
Soplador para paredes externas
pt
Instruções de Serviço e de Montagem
Turbina para paredes exteriores
el
δηγίες ρήσης και τπθέτησης
Φτερωτή εωτερικύ τιώµατς
sv
Bruks- och monteringsanvisning
Ytterväggsfläkt
no
Bruks- og monteringsveiledning
Vifte på utsiden av veggen
fi
Käyttö- ja asennusohjeet
Ulkoseinään asennettava tuuletinmoottori
da
Brugs- og monteringsanvisning
Ydervægventilator
de
en
fr
nl
it
es
pt
el
sv
no
da
7
Important information
This appliance conforms to the relevant
safety regulations.
Repairs should only be carried out by
qualified specialists.
Improperly executed repairs can give
rise to significant hazards for the user.
Note down the type designation of the
external fan in the extractor hood operating
instructions.
Check whether this fan may be
combined with the extractor hood.
The licensed type HBD-MX10-8 must be
indicated in the operating and installation
manuals for the extractor hood.
The appliance should only be
connected up to the mains and taken into
use by a qualified specialist.
Before carrying out repairs or
maintenance, isolate the fan.
To do this, disconnect the plug-and-socket
connection of the electric cable which is
connected to the extractor hood or
disconnect the extractor hood power cord
from the power supply.
If the connecting cable for this
appliance is damaged, the cable must be
replaced by the manufacturer or his
customer service or a similarly qualified
person in order to prevent serious injury to
the user.
Old appliances are not worthless
rubbish. If they are disposed of in an
environment-friendly manner, valuable raw
materials can be recovered for use again.
Before you dispose of an old appliance,
make sure that it has been rendered
inoperative.
This appliance conforms to the relevant
safety regulations.
Repairs should only be carried out by
qualified specialists.
Improperly executed repairs can give
rise to significant hazards for the user.
Your new appliance was protected on
its way to you by the packaging. None of
the materials cause pollution to the environ-
ment and all can be recycled for use again.
Please help to protect the
environment and dispose of the packaging
in an environment-friendly manner.
You can obtain information about the best
method disposing of old appliances and
packaging from your dealer or local
municipal council.
8
Prior to installation
D
If the extractor hood is operating in
exhaust-air mode at the same time as a
flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
there must be an adequate air supply
which the fireplace requires for combusti-
on.
Safe operation is possible if the partial
vacuum in the installation room of the fire-
place does not exceed 4 Pa (0.04 mbar).
This can be achieved if the combustion air
is able to flow through non-lockable ope-
nings, e.g. in doors, windows and in con-
junction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.
If the air supply is inadequate, there is a
risk of poisoning caused by combustion
gases being drawn back into the room.
Note: When assessing the air supply,
always take into account the entire ventila-
tion system in the house. This rule does
not apply when using cooking appliances,
e.g. hob or gas cooker.
The fan must be attached at least 2 m
from the extractor hood.
Do not attach the outer wall fan near
windows, doors or patios.
When attaching the outer wall fan,
ensure that
–residents and neighbours are not
disturbed by noise and odours,
–it is accessible for maintenance and
repairs.
The plug-and-socket connections of
the electric cables must be located inside
the building.
Do not reduce the 150 mm diameter of
the pipes connected to the extractor hood.
An additional silencer for 150 mm l pipes
is available as an optional accessory from
specialist outlets.
Preparing the wall
The wall must be flat and perpendicular.
Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.
Weight: 7,0 kg.
We reserve the right to construction changes within the
context of technical development.
9
Installation
2. Shorten the cable conduit to the wall
thickness and insert.
Insert the telescopic tube:
flush with the outside wall,
overhanging by 30 mm on the inside.
Cable conduit:
Z 3° gradient to the outside.
Telescopic tube:
Z 1° gradient to the outside.
Secure and seal the cable conduit and
telescopic tube.
3. Hold the fan on the wall.
Ensure that the pipe connection of the
fan has been inserted into the telescopic
tube.
Air outlet downwards.
Mark a mounting borehole at top left.
4. Remove the fan.
5. Drill the 8 mm l 8 mm mounting bore-
hole at top left, insert a wall plug, hold
the fan in position and screw to the wall.
1. Wall opening
Drill at least a 160 mm l hole for the
telescopic tube and at least an
18 mm l hole for the cable conduit.
Distance to the floor at least 1 m to
ensure unrestricted air outlet.
6. Ensure that the fan is level and centred
on the telescopic tube.
Mark mounting boreholes at top right
and bottom middle.
Remove the fan again.
10
Installation
8. Detach the plug from the cable.
9. Feed the cable through the cable
conduit.
11. Re-attach the plug to the cable.
Ensure that the wires are connected to
the correct terminals.
10. Hold the fan in position and screw to
the wall.
The fan is connected to the extractor
hood with the Z 5 m extension cable
enclosed with the extractor hood.
If an additional extension cable is required,
the exterior of the fan housing must be
earthed by an electrician before the
housing is screwed into position.
The parts used for earthing must not come
into contact with the fan impeller.
7. Drill the 8 mm l mounting boreholes at
top right and bottom middle.
Insert wall plugs.
The wall plugs must be suitable for the
brickwork.
11
User information
Safety instructions
Regularly check that air can flow freely
out of the fan.
Do not obstruct the air outlet grille or cover
with plants.
If the connecting cable for this
appliance is damaged, the cable must be
replaced by the manufacturer or his
customer service or a similarly qualified per-
son in order to prevent serious injury to the
user.
Cleaning and care
Use a mild non-abrasive stainless steel
cleaner.
Do not use any of the following to clean
stainless steel surfaces: abrasive sponges,
cleaning agents containing sand, soda, acid
or chloride!
Apply a little stainless steel cleaner from
time to time in order to maintain the
appearance of the appliance.
Installation
12. Connect the pipe and cable from the
fan to the extractor hood.
The additional cover on the plug
must always be attached and closed for
safety reasons.
5750 201 635
Printed in Germany 0404 Es.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56