Grandstream Networks UCM6208, UCM6200 series Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Grandstream Networks UCM6208 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Grandstream Networks, Inc.
126 Brookline Ave, 3rd Floor
Boston, MA 02215 USA
Tel : +1 (617) 566 – 9300
Fax: +1 (617) 249 – 1987
www.grandstream.com
For Warranty and RMA information, please visit www.grandstream.com
UCM6208 IP PBX Appliance
Quick Installation Guide
1 2
The UCM6208 is not pre-congured to support or
carry emergency calls to any type of hospital, law
enforcement agency, medical care unit (“Emergency
Service(s)”) or any other kind of Emergency Service.
You must make additional arrangements to access
Emergency Services. It is your responsibility to pur-
chase SIP-compliant Internet telephone service, prop-
erly congure the UCM6208 to use that service, and
periodically test your conguration to conrm that it
works as you expect. If you do not do so, it is your re-
sponsibility to purchase traditional wireless or landline
telephone services to access Emergency Services.
GRANDSTREAM DOES NOT PROVIDE CON-
NECTIONS TO EMERGENCY SERVICES VIA THE
UCM6208. NEITHER GRANDSTREAM NOR ITS
OFFICERS, EMPLOYEES OR AFFILIATES MAY BE
HELD LIABLE FOR ANY CLAIM, DAMAGE, OR LOSS.
YOU HEREBY WAIVE ANY AND ALL SUCH CLAIMS
OR CAUSES OF ACTION ARISING FROM OR RE-
LATING TO YOUR INABILITY TO USE THE UCM6208
TO CONTACT EMERGENCY SERVICES, AND YOUR
FAILURE TO MAKE ADDITIONAL ARRANGEMENTS
TO ACCESS EMERGENCY SERVICES IN ACCOR-
DANCE WITH THE IMMEDIATELY PRECEDING
PARAGRAPH.
PACKAGE CONTENTS:
EN
• Do not attempt to open, disassemble, or modify the device.
• Do not use a third party power adapter.
Do not expose this device to temperatures outside the range of 0 °C to +40 °C for
operating or -10 °C to +60 °C for storage.
Do not expose this device to environment outside of the following humidity range:
10-90% RH (non-condensing).
• Do not power cycle the device during system boot up or rmware upgrade. You
may corrupt rmware images and cause the unit to malfunction.
1x UCM6208 1x RJ45 Cable
1x 12V Power Adapter
OVERVIEW:
UCM6208 is an innovative IP PBX appliance designed for small to medium busi-
ness. Powered by an advanced hardware platform with robust system resources,
the UCM6208 offers a highly versatile state-of-the-art Unied Communication
(UC) solution for converged voice, video, data, fax and video surveillance ap-
plication needs. Incorporating industry-leading features and performance, the
UCM6208 offers quick setup, easy deployment and unrivaled reliability all at an
unprecedented price point.
6x Screws2x Wall Mounts
PRECAUTIONS:
1x Quick Installation Guide
1x GPL License
12V
3 4
CONNECTING THE UCM6208:
1. Connect one end of an RJ-45 Ethernet cable into the WAN port of the
UCM6208.
2. Connect the other end of the Ethernet cable into the uplink port of an Ether-
net switch/hub.
3. Connect the 12V DC power adapter into the 12V DC power jack on the back of
the UCM6208. Insert the main plug of the power adapter into a surge-protected
power outlet.
4. Wait for the UCM6208 to boot up. The front LCD display will show the UCM’s
hardware information when the boot process is completed.
5. Once the UCM6208 is successfully connected to a network, the Network LED
indicator will be lit green, and an IP address will be shown on the LCD display.
6. (Optional) Connect PSTN lines from the wall jack to the FXO ports, connect
analog devices (phone and fax) to the FXS ports.
2x FXS Port
WAN Port
Reset
8x FXO Port
SD Card Slot
USB
Port
Ground
USING THE UCM6208 KEYPAD MENU:
CONFIGURING THE UCM6208 VIA WEB GUI:
1. Connect the computer to the same network as the UCM6208.
2. Ensure the UCM6208 is properly powered on and displays the IP address on
the LCD screen.
3. Open a web browser on the computer and enter the displayed IP address into
the search bar in the following format: http(s)://ipaddress:portnumber.
The default protocol is HTTPS and the default port number is 8089.
4. The web portal should be shown (see gure below). Enter the default admin-
istrator credentials:
Username: admin
Password: admin
Note: Units manufactured from January 2017 onwards have unique default pass-
words printed on their stickers. Older units have “admin” as the default password.
5. For more detailed information on how to congure SIP extensions, PSTN con-
nections, SIP trunks, and other system settings via the web UI, please download
the UCM6208 user manual here: http://www.grandstream.com/support/
1. Press “Down” or “OK” key to start browsing menu options.
2. Press “Down” to browse different menu options. Press “OK” to select an entry.
3. In the menu option, select “Back” to go back to previous menu.
4. The LCD will return to default display after being idle in menu for more than 20
seconds.
LCD
Navigation
Keys
LED Indicators
This product is covered by one or more of the U.S. patents (and any
foreign patent counterparts thereto) identied at www.cmspatents.com.
DC 12V
LAN Port
ACT
SD
USB
Phone1
Phone2
Network
DC IN
RESET
LAN
WAN
37 38
FCC Caution:
Any Changes or modications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a resi-
dential installation. This equipment generates, uses and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Regulatory Information
U.S. FCC Part 68 Statement
This equipment complies with Part 68 of the FCC rules and the requirements
adopted by the ACTA. The unit bears a label on the back which contains among
other information a product identier in the format US: GNIIS01BUCM6208. If
requested, this number must be provided to the telephone company.
This equipment uses the following standard jack types for network connection:
RJ11C.
This equipment contains an FCC compliant modular jack. It is designed to be
connected to the telephone network or premises wiring using compatible modular
plugs and cabling which comply with the requirements of FCC Part 68 rules.
The Ringer Equivalence Number, or REN, is used to determine the number of
devices which may be connected to the telephone line. An excessive REN may
cause the equipment to not ring in response to an incoming call. In most areas,
the sum of the RENs of all equipment on a line should not exceed ve (5.0).
In the unlikely event that this equipment causes harm to the telephone network,
the telephone company can temporarily disconnect your service. The telephone
company will try to warn you in advance of any such disconnection, but if advance
notice isn’t practical, it may disconnect the service rst and notify you as soon as
possible afterwards. In the event such a disconnection is deemed necessary, you
will be advised of your right to le a complaint with the FCC.
From time to time, the telephone company may make changes in its facilities,
equipment, or operations which could affect the operation of this equipment. If
this occurs, the telephone company is required to provide you with advance no-
tice so you can make the modications necessary to obtain uninterrupted service.
There are no user serviceable components within this equipment. See Warranty
yer for repair or warranty information.
It shall be unlawful for any person within the United States to use a computer or
other electronic device to send any message via a telephone facsimile unless
such message clearly contains, in a margin at the top or bottom of each transmit-
ted page or on the rst page of the transmission, the date and time it is sent and
an identication of the business, other entity, or individual sending the message
and the telephone number of the sending machine or of such business, other
entity, or individual. The telephone number provided may not be a 900 number or
any other number for which charges exceed local or long distance transmission
charges. Telephone facsimile machines manufactured on and after December 20,
1992, must clearly mark such identifying information on each transmitted mes-
sage. Facsimile modem boards manufactured on and after December 13, 1995,
must comply with the requirements of this section.
This equipment cannot be used on public coin phone service provided by the
telephone company.
Connection to Party Line Service is subject to state tariffs. Contact your state
public utility commission, public service commission, or corporation commission
for more information.
/