GE AEM06LMG1 Owner's manual

Type
Owner's manual
ge.com
©
Safety Instructions. ............ 2, 3
Operating Instructions
Control I_lob Models ........... 6, 7
Touch Pad Models .............. 4, 5
Care and Cleaning
Air Filter ........................ 7
Outdoor Coils ................... 7
Installation Instructions ....... 8-11
Troubleshooting Tips ........... 1'2
Normal Operating Sounds ........ 12
Consumer Support
Consumer Support ....... Back Cover
Ownership Registration fi)r
Customers in Canada only ..... 13, 14
Warranty for Customers
in Canada ...................... 16
Warranty fi)r Customers
in the U.S.A ..................... 15
AEM 05 *
AEM06*
AEM08*
A_:QO5
A_:&6
_:QOS
AEV05
Climadseur
La section fran(aise commence ?_la page 17
Acondicionador
de aire
*ENERGY STAR ® labeled product
ENERGYSTAR
As an ENERGY STAR ® partner, GE has
determined that this product meets
the ENERGYSTAR®guidelines for
energy efficiency.
Writethemodelandserial numbershere:
Model #
Serial #
Find these numbers on a label on the
side of the air condifioneL
In Canada, contact us at:
xs_s_u.GEAppliances.c a
La secci6n en espa'_,ol empieza en la pdgina 33
494605 12-08JR
IMPORTANTSAFETYINFORMATION.
READALLINSTRUCTIONSBEFOREUSING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury.
SAFETYPRECAUTIONS
}}Use this appliance only for its intended }}
purpose as described in this Owner's
Manual.
iii}i}i
iii}i}}li_
iii}i}}li_
This air conditioner must be properly
installed in accordance xdth the Installation
Instructions before it is used.
Never unplug your air conditioner by pulling
on the power cord. Always _ip plug frmly
and pull straight out flom the receptacle.
Replace immediately 'allelectric ser\@e
cords that have become flayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained flom the manufhcturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its len_h
or at either the plug or connector end.
iii}i}i
iii}i}}li_
iii}i}}li_
Turn the unit OFFand unplug your air
conditioner before making any repairs
or cleaning.
NOTE: Westronglyrecommendthatanyservicing
be performedbya qualified individual.
For your satety...do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the x,icinity
of this or any other appliance.
All air conditioners contain refligerants,
which under federal law must be removed
prior to product disposal. If you are getting
rid of an old product with refligerants,
check with the company handling disposal
about what to do.
If the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
HOWTOCONNECTELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this appliance must be
properly grounded.
DONOT use anadapterplug with this appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall
outlet to minimize the possibility of electric
shock hazard flom this appliance.
Power cord includes a current intermpmr
dex,ice. A test and reset button is prox,ided on
the plug case. The dex,ice should be tested on a
periodic basis by first pressing the rESrbutton
and then the RESErbutton while plugged into
the outlet. If the TESTbutton does not trip
or if the RESETbutmn will not stay engaged,
discontinue use of the air conditioner and
contact a qualifed ser\,ice technician.
Have the wall outlet and circuit checked by
a qualified electrician to make sure the outlet
is properly _ounded.
Where a 2-prong wall outlet is encounmred,
it is your personal responsibility and obligation
to have it replaced with a properly grounded
3-prong wall outlet.
The air conditioner should always be plugged
into its own indix,idual electrical outlet which
has a voltage rating that matches the rating
plate.
This prox,ides the best performance and also
prevents overloading house xdring circuits
which could cause a fire hazard flom
overheated xdres.
See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
2
WARNING!
USEOFEXTENSIONCORDS--115-Voltmodelsonly
Because of potential safety hazards under certain
conditions, we strongly recommend against the
use of an extension cord.
However, if you must use an extension cord,
it is absolumly necessa U that it be a UL-listed,
14 gauge, 3:wire grounding type appliance
extension cord ha\,ing a _ounding type plug
and outlet and that the electrical rating of the
cord be 15 amperes (minimum) and 125 vohs.
-4,CAUTION:
DO NOT usean extension cord with any ofthe
230/208 voltmodels.
ge.com
READANDFOLLOWTHISSAFETYINFORMATIONCAREFULLY.
SAVETHESEINSTRUCTIONS
3
Aboutthe controlsontheair conditionermmodelswith touchpads.
Features and appearance will van
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
Thedisplayalwaysshowsthe room
temperatureexceptwhensettingthe
Settemperatureor theDelaytimer.
Light indicatesthe unit
is in the temperatureor
delaytime Set mode.
,m Auto
_, High !- Fan Only
,m Ned ,m Energg Saver
Low _ Cool
Lightindicates the
delaytimer is set.
Delay
O Delaytimer --
Decrease J
O o e eeo'--y
O an speed
Decrease
Temperature --
set hlcrease
and Decrease
Delaytimer Increase
Auto Fanon/off
FanspeedIncrease
Unit poweron/off
AirConditionerControls
Remote Control
Contro/s
O ower Pad
Turns air conditioner on _md off. _rhen
turned on, tile display will show tile room
temperature.
0 Display
Shows tile room temperature or time
remaining on the Del W fimeL Shows the Set
mmperature while setting the mmperature in
Coolor Energy Saver modes. The Set light will
mrn on while setting.
NOTE:The display will change to show file
room temperature after settings have been
made. To recall the Set mmpemture, press the
TempIncrease or Decrease pads.
O empIncrease •/Decrease Pads
Use to set temperature when in Coolor Energy
Savermode. The Setlight will mrn on while
setting.
O Delay fimerlncrease (+)/Decrease (-)
Pads
Each touch of the Increase •/Decrease
pads on the unit or the Increase +/Decrease -
pads on the remote control will set the delay
time when using tlle Delay1-24hr diner (_).
The Setlight will mrn on while setting.
O an Speed Pads
Use to set the fan speed to LOW,Med, High
or Auto on the unit. NOTE:On the remote
control, use the fan speed Increase +/
Decrease - pads to set the fan speeds to LOW,
Med or High. Use the Auto pad to turn Auto
fan on.
O ode Pad
Use to set tl_eair conditioner to Cool,Energy
Saveror FanOnlymode.
0
Delay Pads
Delay ON--When the air conditioner is off, it
can be set to automatically come on in 1 to 24
hems at its previous mode and fan settings.
Delay OFF--When the air conditioner is on,
it can be set to automatically mrn offin 1 to
24 hems.
How toset:
Press file Delay 1-24hrpad on the trait or
file _ pad on file remora conuol. Each touch
of the Increase •/Decrease pads on the
unit or the Increase+/Decrease- pads on
die remote conuol will set die timer in
1-hour intervals. The Set light will mrn on
while setting.
To review die remaining time on die Delay
1-24hrtimei; press the Delay 1-24hr pad on the
unit or the @ pad on the remote control. Use
the Increase •/Decrease pads on the unit
or the Increase +/Decrease-pads on the
remote control to set a new time if desired.
Tocancel the timer, press tt_e Delay 1-24hr pad
until tile light on the Delay 1-24hr pad goes off:
4
ge.com
Do Not Operate in Freezing Outdoor Conditions
This cool<rely air conditioner was not designed for
fleezing outdoor conditions. It illust not be used in
fleezing outdoor conditions.
Remote Control
To ensure proper operation, aim file remora
conuol at the signal receiver on the air
condifioneL
Tile remote conuol signal has a range of
up m 20 feet.
Make sure riDdling is between die air conditioner
and the remora conuol that could block the
sigmal.
Make sure batteries are flesh and instaUed
correctly _tsindicated on the remora conuol.
CoolMode
Use file Coolmode at Low,Med,Highor AutoFan
Speedfor cooling. Use tile TemperatureIncrease /
Decrease pads to set tile desired temperature
between 64°F and 86°F in 1°F increments.
An electronic fllemlostat is used to maintain file
room temperature. Tile compressor will cycle on
and off to keep file room at file set level of comfort.
Set file themlostat at a lower number and file indoor
air will become cooleL Set die fllelInostat at a higher
number and file indoor air will become wamleL
NOTE:If theairconditionerisoffandisthenturnedon
whilesettoa Coolsettingorif turnedfromafansetting
toa Coolsetting,it maytakeapproximately3minutes
forthecompressortostartandcoolingtobegin.
Cooling Descriptions
For Normal Cooling--Select the Coolmode and
High or Med fan with a middle set temperature.
For Maximum Cooling--Select tile Cool mode
and High fan with a lower set temperature.
For Quieter & Nighttime Cooling--Select tile
Cool mode and LOWfan with a middle set
tempemtme.
Energy Saver Mode
Controls tile fan.
ON--The fan will cycle on and offwifll file
compressoL This results in wider variations of room
temperature and humidity. Normally used when tile
room is unoccupied. NOTE: The fan may continue to run
fora short time after the compressorcycles off.
OFF--The tim runs all tile time, while file
compressor cycles on and off:
Fan OnlyMode
Use the FanOnlyModeat Low,Medor Highfan
speed to provide air circulation and filtering
without cooling. Since fan only settings do not
provide cooling, a Set mmperamre camlot be
enmred. Tile room mmpemmre will appear
in tile displW.
NOTE:AutoFanSpeedcannotbeusedwheninthe
FanOnlyMode.
Auto Fan Speed
Set to Autofan speed for tile fan speed to
automatically set m tile speed needed m provide
optimum comfort settings wifll tile set temperature.
If the room needs more cooling, the fan speed
will automatically incre_tse. If the room needs less
cooling, the fan speed will automatically decrease.
NOTE:AutoFanSpeedcannotbeusedwheninthe
FanOnlyMode.
Power Outage Recovery Feature
In tile case of a power outage or interruption, tile
unit will automatically re-start in the settings last
used after tile power is restored. If tile Delay 1-24hr
feature was set, it will resume countdown. You may
need to set a new time if desired. 5
Aboutthecontrolsontheair conditionermmodelswith controlknobs.
Features and appearance will var}4.
MODE
High
Cool.
Cool
OFF
High
MODECONTROL
TEMP
Coolest
TEMPERATURECONTROL
Contro/s
0
Mode Control
HighCool,Med Cooland LowCool
provide cooling with (liff_rent fan speeds.
Fan settings provide Mr circulation and
filtering Mfllout cooling.
NOTE:If youmovethemodecontrolfroma cool
settingtoOFFortoa fansetting,waitatleast
3 minutesbeforeswitchingbacktoa coolsetting.
Cooling Descriptions
ForNormal Cooling--Select HighCoolor Med Cool
with tile TEMPERATURE control at midpoint.
ForMaximum Cooling--Select High Coolwith tile
TEMPERATURE control at the highest number
available on your knob.
ForQuieterandNighttimeCooling--Select Low
Coolwith tile TEMPERATURE control at
midpoint.
O
TEMP Control
Tile TEMP control is used to maintain the
room tempe_mre. Tile compressor will cycle
on and off"m keep tile room at tile same level
of comfolt. _r]len you mrn the knob to a
higher numbe_; the indoor air will become
cooleL Turn the knob m a lower number mid
tile indoor air will become warmeL
6
Additional important information.
Air Direction
Use die lever to adjust file air direction left and
right only.
Appearancemayvary.
ge.com
Careand cleaning oftheair conditioner.
Grille and Case
Turn the air conditioner off and remove the plug To clean, use water and a mild detergent. Do not
flom tile wall oudet before cleaning, use bleach or ab_sives.
Air Filter
The air filter behind the front grille should be
checked and cleaned at least eve_T 30 days or
more often if necessary.
Toremove:
Push on one side of the filter edge and pull it out
the other side.
Glean tlle filter widl warm, soapy wateL Rinse and
let the filter dry before replacing it. Do not clean
the filter in a dishwasheL
CAUTION:DoNoToperatetheair
conditionerwithouta filterbecausedirtandlintwillclog
it andreduceperformance.
Appearancemayvary.
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly: If flley are clogged
with dirt or soot, they may be professionally cleaned.
How to Insert the Batteries in the Remote Control
[-_ Remove the batte D,cover by sliding it
according to the arrow direction.
Insert new batteries, making sure that the (+)
and (-) of battery are installed correcdy.
[-_ Reatmch the cover by sliding it back
into position.
NOTES:
Use 2 "AAA" (1.5 volt) alkaline batteries. Do not
use rechargeable batm_ies.
Remove the batteIies flom the remora control if
the sysmm is not going m be used for a long time.
7
ilnsta,,at,onnsttuct,onsIAirC°ndit'°nerl
I F_ Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: ge.com I
I
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
I
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT - Savethese
instructions for local inspector's use.
IMPORTANT - Observeall
governing codes and ordinances.
Note to Installer- Be sure to leave these
instructions with the Consumer.
Note to Consumer- Keep these
instructions for future reference.
Skill level - Installation of this appliance
requires basic mechanical skills.
Completion time- Approximately 1 hour
We recommend that two people install
this product.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
You MUST use all supplied parts and use
proper installation procedures as described
in these instructions when installing this air
conditioner.
(_ ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC,
60 Hz grounded outlet protected with a
15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
©
Some models require 230/208-volt AC,
protected with a time delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for
best performance and to prevent
overloading house or apartment wiring
circuits, which could cause a possible
fire hazard from overheating wires.
- CAUTION:
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
problemsmconsult a qualified electrician.
TOOLS YOU WILL NEED
Phillips head screwdriver
Flat-blade screwdriver
Pencil Ruler or tape measure
Level Scissors or knife
8
Power cord includes a current interrupter
device. A test and reset button is provided on
the plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button while plugged into
the outlet. If the TEST button does not trip or
if the RESET button will not stay engaged,
discontinue use of the air conditioner and
contact a qualified service technician.
Installation Instructions
PARTS INCLUDED
(Appearance may vary)
Top mou_
Air
conditioner
\
Window
eal
vv,_a_;_
Left
accordion
panel
Right
accordion
panel
- /
Top mo "_
seal strip
Type A (6) Type B (3) Type C (5)
Window locking
bracket (1)
9
Installation instructions
[i] WINDOW REQUIREMENTS
These instructions are for a standard
double-hung window. You will need to
modify them for other types of windows.
The air conditioner can be installed
without the accordion panels if needed
to fit in a narrow window. See the
window opening dimensions.
All supporting parts must be secured
to firm wood, masonry or metal.
The electrical outlet must be within
reach of the power cord.
Follow the dimensions in the table and
illustration for your model.
Models A B
AEQ05, AEQ06, AEV05 13" min. 24 1/2"-38 1/8"
AEM05, AEM06,
AEM08, AEQ08 13 5/8" min. 24 1/2"-38 1/8"
!
B====8
t
A
(With accordion panels)
_] STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly.
To adjust for this, attach a piece of wood to
the sill.
WOOD PIECES
WIDTH: 2"
LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness, place
a piece of wood on the sill to make it 1/2"
higher than the top of the storm window
frame or the vinyl frame.
Attach securely with nails or screws provided
by the installer.
1/2" higher
than vinyl frame
1/2" higher _ _ (on some windows)__.
Wood
Tn P,,_-,/_1
than
storm
window _---pi =1=II _/,r-
frame _ Sill FT _
Storm window
frame _ r_ Vinyl frame [ [
10
[] ATTACH THE TOP MOUNTING
RAIL SEAL STRIP
Remove the backing from the top mounting
rail seal strip and attach the seal strip to the
bottom of the top mounting rail, along the
front edge.
Top mounting rail
Remove
backing
from seal
strip
FRONT VIEW
o.o*, o ..,, . . . ** ,, ,... ,
/
Seal strip
Top mounting rail
1
[] PREPARE THE AIR CONDITIONER
['_ Install the top mounting rail with 3 Type B
screws from the outside of the case.
Bottom mounting rail
[] Slide the left and right accordion panels
into the top and bottom mounting rails.
Top right
Top left
Installation instructions
r41 PREPARE THE AiR CONDiTiONER
(cont.)
FC-]Attach the accordion panels to the case
using 3 Type A screws on each side.
Top mounting rail
Accordion
panel
Type
screws
BACK
Bottom mounting rail
F5qPREPARE THE WINDOW
Cut the window sash seal to the proper
length. Peel off the backing and attach the
seal to the underside of the window sash.
11
[]
[]
iNSTALL THE AIR CONDiTiONER
IN THE WINDOW
Place the air conditioner on the sill with
the bottom mounting rail against its back
edge, Center it and close the window
securely behind the top mounting rail,
It should be level or slightly tilted to the
outside, Use a level; about a 1/3 bubble
will be the correct case slant to the outside,
Type C screws
FB7Extend the left and right accordion panels
to the vertical window sashes and attach,
through the holes in the panels, with 4
Type C screws, as appropriate.
[] INSTALL SUPPORT BRACKET AND
FOAM TOP WINDOW GASKET
-&CAUTION:
To prevent broken glass
or damage to windows,
on vinyl or other
similarly constructed
windows, attach the
support bracket to the
window side jam.
Vinyl
Attach the support
bracket with one
Type C screw,
Wood
[]
Fcq
Cut the foam top window gasket to the
window width.
Stuff the foam
between the
glass and the
window to
prevent air and
insects from
getting into the room.
NOTE: If the gasket supplied does not fit
your window, obtain appropriate material
locally to provide a proper installation seal.
TroubleshootingTips.
Airconditioner
doesnotstart
Possible Causes What ToDo
The air conditioner
is tmplugged.
The fuse is blown/circuit
breaker is tripped.
Power failure.
Make sure the air conditioner plug is pushed
completely into tile outlet.
Check tile house fixse/circuit breaker box and replace
tile flxse or reset tile breakeL
Tile unit will automatically re-start in tile settings last
used after the power is restored.
There is a protective time del W (approximately
3 minutes) to prevent tripping of tile compressor
overload. Fox this reason, tile unit may not start
normal cooling for 3 minutes after it is turned
back on.
The current interrupter Press the RESETbutton located on the power cord plug.
device is tripped. If tile RESETbutton will not stay engaged, discontinue
use of tile air conditioner and contact a qualified
service technician.
Air conditioner does Airflow is restricted. Make sure there are no curtains, blinds or fiuniture
not coolas it should blocking the flont of the air condifioneL
The temp control may On models wifll touch pads: In tile Cool mode, press tile
not be set correctly. Decrease pad.
On models with control kalobs, mrn tile temperature
knob m a higher numbeL
The air filter is dirty. Glean tile filter at least every 30 days.
See tile Care and Cleaning section.
The room may have been hot. • When tile air conditioner is filst turned on, you need
to allow time for file room to cool down.
Cold air is escaping. Gheck for open fiunace regfiste_ and cold air returns.
Cooling coils have iced up. See "Air conditioner freezing up" below.
Air conditioner
freezingup
Ice blocks the air flow
and stops the air conditioner
from cooling the room.
On models widl conUol knobs, set die mode conuol at
HighFanor HighCoolwitb the rempat I or 2.
On models with touch pads, set tile controls at HighFan
or High Cooland set the tbemlosmt m a higher
tempex_mxre.
Theremote control The batteries are inserted *Check tile position of tile batteries. They should be
is not working incorrectly, inserted in tile opposite (+) and (-) direction.
The batteries may be dead. =Replace the batteries.
Waterdrips outside Hot, humid weather. This is normal.
Waterdrips indoors The air conditioner is not Fox proper water disposal, make sure tile air conditioner
tilted to the outside, slants slightly from the case flont to the real
Watercollects in Moisture removed from air This is normal for a short period in areas with little
basepan and drains into base pan. humidiD,; hernial for a longer period in very humid areas.
72
Normal Operating Sounds
You may hear a pinging noise caused by water
being picked up and thrown against tile
condenser on rainy dws or when the humidity
is high. This design feature helps remove
moisture and improve efficiency.
}_You may hear tile thernlosmt click when tile
compressor cycles on and off:
Water Mll collect in die base pan during
high humidity or on rainy days. Tile wamr
may overflow and drip flom tile outdoor side
of tile unit.
}_Tile fan may run even when tile compressor
does not.
For Canadian
Customers
Pour les
Consommateurs
Canadiens
Z I
"rl
ZI
ral
LUI
Zl
I
II
l.-I
Z I
Peaseregisteryourproducttoenableustocontactyou
intheremoteeventasafetynonceisissuedforthisproduct
andtoallowforefficientcommunicationundertheterms
ofyourwarranty,shouldtheneedarise.
REGISTERON-UNE: wwvv,geappJiances,ca MAILTO:,
ENREGISTREMENTSURJNTERNET_,:vvvvw,eiectremenagersqe,ca POSTERA:
[][] MJSS/NLLE.MR'/M[][] Ms.MRS'/MME"F1RSTNAME/PRt_NOM LASTNAME/NOM
STREETNO/N° RUE STREF NAME/RUE
CITY/VlLLE
AREACODE/IND.Rt_G.[TELEPHONE [E-MAIL
DiDYOUPURCHASEASERVICECONTRACTFORTHISAPPLIANCE?
AVEZ-VOUSACHETEUN CONTRATDESERVICEPOURCETAPPAREIL?
VeuiUezenregistrerv_eproduitafindenouspermet/_ede
communiqueravecvoussijamaisunavisdes6curi_concemant
ceproduit_ait6misetdecommuniquerfacibmentavecvousen
vertudev_e gara_e,sib besoinsenfairsentk.
RO.BOX1780,MISSISSAUGA
ONTARIO,L4Y461
YES/OUI[]
NO/NON[]
APT.NO/APP./RR#
PROVINCE POSTALCODE/POSTAL
IFYES/SiOUI:EXPIRATION
Y/A M D/J
NAMEOFSELUNGDEALER/ NOMDU MARCHAND MODEL / MOD_:LE
INSTALLATIONDATE/ DATED'INSTALLATON]
Y/A M D/J CORRESPONDENCE [] ENGLISH
CORRESPONDANCE [] FRANC,,AIS SERmALiSERmE
[] Ido notwishtoreceiveanypromotionaloffersregardingthisproduct.
[] Jenedesirepasrecevoird'offTespromotionnellesconcemantceproduit.
14
GEAir Conditioner--One-YearLimitedWarranty.(For customers in the U.S.A.)
All warranty service provided by our Factory Service Centers,
or an authorized Customer Care_ technician. Toschedule service
visit us on-line at ge.com, or call 800.GE.CARES (800.432.2737).
Have serial number and model number available when calling
for service.
Staple yourreceipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
Fromthedateof the
originalpurchase
GE Will Replace:
Anypartof file air conditioner which fails due to a defect m materials or workmanship.
During this limited one-year warranty, GE will also provide, free of charge, all labor and relamd
sexMce to replace the defective part.
Service trips to your home to teach you how to
use the product.
Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You are responsible
for providing adequate electrical connecting facilities.
Failure of the product resulting from modifications to
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.
In commercial locations, labor necessary to move the
unit to a location where it is accessible for service
by an individual technician.
Replacement of house fuses or resetting of circuit
breakers.
Failure due to corrosion on models not corrosion-
protected.
Damage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by possible
defects with this air conditioner.
Damage caused after delivery.
EXCLUSION OFIMPLIED WARRANTIES--Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortestperiod allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. If the product is located in an area where service by a GEAuthorized Servicer is not available,
you may be responsible for a trip charge or you may be required to bring the product to an Authorized GEService
location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. Toknow what your
legal rights are, consult your local or state consumer affairs office or your state's Attorney General
Warrantor: General Electric Company.Louisville, KY 40225
15
GEAir Conditioner--One-YearLimitedWarranty. ForcustomersintheCanada
All warranty service provided by our Factory Service Centers,
or an authorized Customer Care_ technician. For service, call
1.800.561.3344.Please have serial number and model number
available when calling for service.
Staple yourreceipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
Fromthedate Ofthe
originalpurchase
Mabe Will Replace:
Anypartof file air conditioner which fails due to a defect in materials or workmanship.
During this limitedone-yearwarranty,Mabe will also provide, free of charge, all labor and
related service to replace the defective part.
Service trips to your home to teach you how to
use the product.
Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You are responsible
for providing adequate electrical connecting facilities.
Failure of the product resulting from modifications to
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.
In commercial locations, labor necessary to move the
unit to a location where it is accessible for service
by an individual technician.
Replacement of house fuses or resetting of circuit
breakers.
Failure due to corrosion on models not corrosion-
protected.
Damage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by possible
defects with this air conditioner.
Damage caused after delivery.
EXCLUSION OFIMPLIED WARRANTIES--Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortestperiod allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased in Canada
for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed
reasonable by Mabe toprovide.
Some provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from
province toprovince. Toknow what your legal rights are in your province, consult your local or provincial consumer
affairs office.
Warrantor: Mabe Canada Inc.,
Burlington, Ontario
16
For Canadian
Customers
Pour les
Consommateurs
Canadiens
z
Z
rr"
rr"
C3
Z
uJ
Z
..-1
_9
Z
I
I
I
I
I
I
I
Pleaseregisteryour product to enableusto contact you
in theremoteeventasafetynolJceisissuedforthis product
andtoallow for efficientcommunicaOonunderthe terms
ofvour warranty,shouNthe need arise.
REGISTERON-LINE: wwvv,geappJiances,ca MAILTO:
ENREGISTREMENTSURINTERNED_,:_.electtemenaqersge.ea POSTER_,:
[][]MISS/MLLE.MR'/M[][]Ms.MRS'/MME'FIRSTNAME/PRENOM LASTNAME/NOM
STREETNO/ N°RUE STREETNAME/RUE
crrY/VILLE
Veuilbzenregis_ervolreproduitafindenouspermet_ede
communiqueravecvoussijamaisunavisdes6cur_ concemant
ceproduit6tait_misetdecommuniquerfacibmentavecvousen
ver_devo_egaranlJe,silebesoins'enfairsen_r.
p.o.BOX1780,MISSISSAUGA
ONTARIO,L4Y461
A_. NO/APP./RR#
PROVINCE POSTALCODE/POSTAL
AREACODE/IND.RE_G.[TELEPHONE JE-MAIL
DIDYOUPURCHASEASERVICECONTRACTFORTHISAPPLIANCE? YES/OUI El IFYES/ SlOUI:EXPIRATION
Y/A M D/J
AVEZ-VOUSACHETI_UN CONTRATDESERVICEPOURCETAPPAREIL? NO/NON []
NAME OFSELLINGDEALER/ NOMDU MARCHAND MODEL /MODt _LE
SERIAL/St_RIE
INSTALLA11ONDATE/DATED'INSTALLA11ON
Y/A M D/J CORRESPONDENCE [] ENGLISH
CORRESPONDANCE [] FRAN(_AIS
[] Ido notwishtoreceiveanypromotionaloffersregardingthisproduct.
[] Jened6sirepasrecevoird'offrespromotionnellesconcemantceproduit
I ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
L
30
ConsumerSupport.
GEAppliancesWebsite In the U.S.A.ge.com
Have a question or need assistance with your appliance? TD, the GE Appliances Website 24 hours a day,
any day of the year! Fox greater convenience and fi,tster service, you can now download Owner's Manuals,
order parts or even schedule sexMce on-line. In Canada: www.GEAppliances.ca
ScheduleService /, the U.S.A.ge.com
Expert GE repair service is only one step away from your dooL Get onqine and schedule your service at your
convenience 24 hours any day of the year[ Or call 800.GE.CARES (800.432.2737) during nomml business hems.
In Canada, call 1.800.561.3344
RealLifeDesignStudio In the U.S.A.ge.com
GE supports the Universal Design concept--products, services and environments that c_m be used by people of all
ages, sizes and capabilities. We recognize the need m desigm for a wide range of physical and mental abilities and
impaimmnts. Fox derails of GE's Univexsal Design applications, including kitchen design ideas for people with
disabilities, check out our Website today. Fox the hearing impaired, please call 800.TDD.GEAC (800.833.4322).
In Canada, contact: Managex; Consumer Relations, Mabe Canada Inc.
Suim 310, 1 Factory Lane
Moncmn, N.B. El(; 9M3
ExtendedWarranties
In the U.S.A.ge.com
Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still
in eff>ct. You can purchase it on4ine anytime, or call 800.626.2224 during nomml business hems. GE Consumer
Home Services will still be there after your warranty expires. In Canada, call 1.888.261.2133
PartsandAccessories
In the U.S.A.ge.com
IndMduMs quMified m sexMce dleir own appliances can have parts or accessories sent directly m their homes
(VISA, MasmrCard and Discover cards are accepted). Order on4ine today, 24 hours evexy day or by phone at
800.626.2002 during nomml business hems.
Instructionscontainedinthis manualcoverprocedurestobeperformedbyanyuser.Otherservicing generallyshouldbe
referredtoqualifiedservicepersonnelCautionmustbeexercised,since improperservicing maycauseunsafeoperation.
Customers in Canada should consult the yellow pages for the nearest Mabe service centex; or call 1.800.561.3344.
ContactUs
/n the U.S.A.ge.com
If you are not satisfied Mill die sexMce you receive flom GE, contact us on our Website Mill all die derails
including your phone numbex; or write to: GenerM Managex; Customer Relations
GE Appliances, Appliance Park
Louisville, KY40225
In Canada: www.GEAppliances.ca, or write to: Directox; Consumer Relations, Mabe Canada Inc.
Suite 310, 1 Facmxy Lane
Moncmn, N.B. E1C 9M3
RegisterYourAppliance /n the U.S.A.ge.com
Register your new appliance on-line--at your convenience! Timely product registration will allow for enhanced
communication and prompt service under the temls of your warranty, should the need arise. You may also mail
in the we-.printed registration card included in the packing material. In Canada: www.GEAppliances.ca
Printed in China
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

GE AEM06LMG1 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI