GE AEE08ATL1 Owner's manual

Type
Owner's manual

This manual is also suitable for

GEAppliances.corn
I,.,
0_
.t..!
0_
Safety Instructions ........................2,3
Operoting Instructions .................4,s
Care and Cleaning
Air Filter .............................................................5
Grille and Case ...............................................5
Outdoor Coils ..................................................5
Installation Instructions
Through-the-Wall
Installation-Optional ...............................12
Window Installation .............................7-11
Troubleshooting Tips ..............14, 15
Consumer Support
Consumer Support ..................Back Cover
Ownership Registration for
Customers in Canada only ............15, 16
Warranty for Customers
in Canada .......................................................17
Warranty for Customers
in the U.SA.....................................................18
AEE08
AEE12
Climatiseur
La section franqaise commence 8 la page 19
Acondicionador
deaire
Lo secci6n en espahol empieza en la pdgina 35
®
Write the model and serial numbers here:
Model #
Serial #
Find these numbers on a label on the side of
the air conditioner.
In Canada, contact us at:
www.GEAppliances.ca
49-7665-1 10-12 GE
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
A WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric
shock or personal injury.
SAFETYPRECAUTIONS
Use this appliance only for its intended purpose
as described in this Owner's Manual.
This air conditioner must be properly installed
in accordance with the Installation Instructions
before it is used.
TurntheunitOFFand unplugyourairconditioner
before making any repairs or cleaning.
NOTE: We strongly recommend that any
servicing be performed by a qualified
individual.
Never unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and
pull straight out from the receptacle.
Replace immediately all electric service
cords that have become frayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufacturer and not
repaired. Do not use a cord that shows cracks
or abrasion damage along its length or at
either the plug or connector end.
If the receptacle does not match the plug, the
receptacle must be changed out by a qualified
electrician.
Foryour safety...do not store or use combustible
materials, gasoline or other flammable vapors
or liquids in the vicinity of this or any other
appliance.
All air conditioners contain refrigerants, which
under federal low must be removed prior to
product disposal. If you are getting rid of an
old product with refrigerants, check with the
company handling disposal about what to do.
These R410A air conditioning systems require
contractors and technicians to use tools,
equipment and safety standards approved for
use with this refrigerant. DONOTuse equipment
certified for R22 refrigerant only.
HOW TOCONNECT ELECTRICITY
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord. For
personal safety, this appliance must be properly
grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall outlet
to minimize the possibility of electric shock hazard
from this appliance.
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
Where a 2-prong wall outlet is encountered, it is
your personal responsibility and obligation to have
it replaced with a properly grounded 3-prong wall
outlet.
The air conditioner should always be plugged into
its own individual electrical outlet which has a
voltage rating that matches the rating plate.
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case.
The device should be tested on a periodic basis by
first pressing the TEST button and then the ,RESET
button. If the TEST button does not trip or if the
RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
This provides the best performance and also
prevents overloading house wiring circuits which
could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
2
A WARNING!
EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or
death.
,, DO NOT use an extension cord with this Window
Air Conditioner.
,, DO NOT use surge protectors or multi-outlet
adaptors with this Window Air Conditioner.
GEAppliances.com
READAND FOLLOW THISSAFETYINFORMATIONCAREFULLY.
SAVE THESE INSTRUCTIONS
About the controls on the air conditioner.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
NOTE:The display always Light indicates the unit
shows the room temperature is inthe temperature or
except when setting the Set delaytime Setmode.
temperature or the Delay
timer.
O
T__ Delay 1-24hr
Delay timer 0
Decrease
_ o,o_.oo Cv]iz_ @
m High am Cool Mode select
amMed _ Energg Saver
m Low m Fon Only Fan speed
Temperature
set Increase
" and Decrease
Light indicates the delay
timer is set.
Delay timer
Increase
Air Conditioner Controls
Remote Control
Controls
Power Pad
Turns air conditioner on and off.When turned on,
the display will show the room temperature.
Display
Showsthe room temperature or time remaining
on the Delaytimer. Showsthe Settemperature
while setting the temperature in Heat, Cool or
Energy Saver modes.TheSet lightwill turn on
while setting.
Temp Increase A/Decrease T Pads
Useto set temperature when in Heat, Cad or
Energy Saver mode. TheSet lightwill turn on while
setting.
Delay Timer Increase A (+)/Decrease T (-)
Pads
Eachtouch of the Increase A / Decrease T pads
on the unit or the Increase + / Decrease - pads
on the remote control will setthe delay time when
using the Delay 1-24hr timer. TheSetlight will turn
on while setting.
Fan Speed Pads
Useto set the fan speedto Low, Med, High or
Auto on the unit. NOTE:On the remote control, use
the fan speedIncrease + / Decrease - padsto set
the fan speedsto Law, Mealor High. Usethe Auto
pad to turn Auto fan on.
Mode Pad
Useto set the air conditioner to Heat, Coal, Energy
Saver or FanOnly mode.
Delay Pads
Delay ON--When the air conditioner isoff,it can
be set to automatically come on in i to 24 hours
at its previous mode and fan settings.
Delay OFF--When the air conditioner ison,it can
beset to automatically turn off in i to 24 hours.
How to set:
Pressthe Delay 1-24hr pad on the unit or on the
remote control. Eachtouch of the Increase A /
DecreaseT pads on the unit or the Increase + /
Decrease - pads on the remote control will set the
timer in 1-hour intervals.TheSetlight will turn on
while setting.
To review the remaining time on the Delay 1-24hr
timer, pressthe Delay 1-24hr pad on the unit
or on the remote control. Usethe Increase A /
Decrease T padson the unit or the Increase + /
Decrease - pads on the remote control to set a
new time if desired.
Tocancel the timer, press the Delay 1-24hr pad
until the light on the Delay 1-24hr pad goes off.
Note: The default temperature reading on the display isdegree Fahrenheit (°F). Tochange the display to
degree Celcius (°C),pressthe Temp Increase A and Temp Decrease T buttons together and hold for 3
seconds. Repeat the process to change back to degree Fahrenheit (°F)
4
Heat Mode
Usethe Heat mode at Low, Med, High or Auto Fan
Speed for heating. Usethe Temperature Increase A
/ Decrease T pads to set the desiredtemperature
between 61°Fand 86% in I°F increments.
GEAppliances.com
An electronicthermostat isusedto maintain the room
temperature. Theheaterwill cycleon and off to keepthe
room at the set levelof comfort.
Cool Mode
Usethe Cool mode at Low, Med, High or Auto Fan
Speedfor cooling. Usethe Temperature Increase A
/ Decrease T padsto set the desiredtemperature
between 61°Fand 86% in I°F increments.
An electronicthermostat isusedto maintain the room
temperature. Thecompressorwill cycleon and off
to keepthe room at the set levelofcomfort. Setthe
thermostat at a lower number and the indoor air will
become cooler.Setthethermostat at u higher number
and the indoor airwill become warmer.
NOTE:If the air conditioner isoff and isthen turned on
whileset to a Coolsetting or if turned from a fan setting
to a Cool setting,it may take approximately 5 minutes
for thecompressor to start and cooling to 5egin.
Cooling Descriptions
ForNormal Cooling--Select the Cool mode and High or
Madfan with a middle set temperature.
ForMaximum Cooling--Select the Cool mode and High
fan with u lower set temperature.
ForQuieter end Nighttime Cooling-Select the Cool
mode and Low fun with a middle set temperature.
Energy Sever Mode
Controlsthe fan.
ON--The fan will cycleon and off with the compressor.
This results inwider variations of room temperature and
humidity. Normally used when the room isunoccupied.
NOTE:Thefan may continue to run for a short time after
the compressorcyclesoff.
OFF--Thefan runs all the time, while the compressor
cycles on and off.
Fan Only Mode
Usethe FanOnly Modeat Low, Hed or Highfan speed
to provide air circulation and filtering without cooling.
Sincefan-only settings do not provide cooling, a Set
temperature cannot be entered.The room temperature
will appear inthe display.
NOTE:AutoFanSpeedcannot be usedwhen in the Fan
Only Mode.
Auto Fen Speed
Setto Auto fan speedfor the fan speedto
automatically set to the speedneeded to provide
optimum comfort settings with the set temperature.
Ifthe room needs more cooling, the fan speedwill
automatically increase. Ifthe room needs lesscooling,
the fan speedwill automatically decrease.
NOTE:AutoFanSpeedcannot be usedwhen in theFan
Only Mode.
Remote Control
To ensureproper operation, aim the remote control
at the signal receiver on the air conditioner.
Hake sure nothing isbetween the air conditioner
and the remote control that could block the signal.
Theremote control signal hasa range of
up to 20 feet.
Hake sure batteries are fresh and installed correctly
as indicated on the remote control.
Remotecontains a magnet allowing it to attach to
metal surfaces.
Power Outage Recovery Feature
Inthe case of a power outage or interruption, the unit
will automatically re-start in the settings last used after
the power is restored.If the Delay1-24hr feature was
set,itwill resume countdown. You may need to set a
new time if desired.
About the controls on the air conditioner.
Additionalimportant information.
Air Direction
Usethe leverto adjust the air direction left and right
only.
Fingertip pressureon the horizontal louvers adjusts the
air direction up or down.
Care and cleaning of the air conditioner.
Grille and Case
Turnthe air conditioner off and remove the plug from Toclean, usewater and a mild detergent. Donot use
the wall outlet before cleaning, bleach or abrasives.
Air Filter
Theair filter behind the front grille should be checked
and cleaned at least every 30 days or
more often if necessary.
To remove:
Pushon one side ofthe filter edge and pull it out the
other side.
Cleanthe filter with warm, soapy water. Rinseand let
the filter dry before replacing it. Donot clean the filter in
a dishwasher.
A
_kCAUTiON: ooNoToperate theair
conditioner without a filter because dirt and lint
will clog it and reduce performance.
Outdoor Coils
Thecoils on the outdoor sideof the air conditioner
should be checked regularly. Ifthey are clogged with dirt
or soot,they may be professionallycleaned.
Normal Operating Sounds
iiiiiiiiiiii_iii
You may hear a pinging noise caused by
water being picked up and thrown against the
condenser on rainy days or when the humidity is
high. This design feature helps remove moisture
and improve efficiency.
You may hear the thermostat click when the
compressor cycles on and off.
Water will collect in the base pan during high
humidity or on rainy days.Thewatermay overflow
and drip from the outdoor side of the unit.
Thefan may run even when the compressor does
not.
I stall ti
I structi ns
Air Conditio r
BEFORE YOU BEGIN
Readthese instructions completelyand carefully.
. IMPORTANT - Savetheseinstructions
for local inspector's use.
. IMPORTANT - Observeallgoverning
codes and ordinances
, Note to Installer- Be sure to leave these
instructions with the Consumer.
, Note to Consumer - Keep these instructions for
future reference.
, Skill level - Installation of this appliance requires
basic mechanical skills.
, Completion time - Approximately 1 hour
. We recommend that two people install this
product.
. Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the Warranty.
You MUST use all supplied ports and use proper
installation procedures as described in these
instructions, and any separate kit instructions,
when installing this air conditioner.
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt a.c., 60 Hz
grounded outlet protected with a 15-amp time
delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall outlet you
plan to use isonly a 2-prong outlet, it isyour responsibility
to hove it replaced with a properly grounded 3-prong
wall outlet.
(_ Some models require 230/208-volt o.c.,
protected with a time delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for best
performance and to prevent overloading house
or apartment wiring circuits, which could cause
a possible fire hazard from overheating wires.
tkCAUTION:
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems-consult a qualified electrician.
If the sill support bolts do not contact the window
sill, or if you have a window without a sill, you
must order accessory kit RAK87 to properly install
this air conditioner. Call 800.626.2002 or visit
GEAppliances.com.
TOOLS YOU WILL NEED
Phillips-head screwdriver
Adjustable wrench Flat-blade screwdriver
Pencil Ruler or tape measure
Level Scissors or knife
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case.
The device should be tested on o periodic basis by
first pressing the TESTbutton and then the RESET
button. If the TESTbutton does not trip or if the RESET
button will not stay engaged, discontinue use of the air
conditioner and contact a qualified service technician.
Window Installation Instructions
PARTS INCLUDED
(appearance may vary)
Left accordion
panel
. Foa_
window gasket ....
Sill support (2)
Nut (2)
Bolt (2)
Top mounting rail
Case bottom seal
(thin, adhesive-backed)
Right
accordion
panel
Window locking
Type A(6) Type B (7) Type C(6) Type D (3) bracket (2)
8
Window Installation Instructions
l'_ WINDOW REgUIREMENTS
, These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
, CAUTION: If the sill support bolts
do not contact the window sill or if you have a
window without a sill, you must order accessory
kit RAK87 to properly install this air conditioner.
Call 800.626.2002 or visit GEAppliances.com.
, All supporting parts must be secured to firm
wood, masonry or metal.
, The electrical outlet must be within reach of
the power cord.
m
P
1
16.4" min T
27" to 36"
(With accordion ponels)
[_] STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly. To adjust for this,
attach a piece of wood to the stool.
WOOD PIECES-
WIDTH: 2"
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: The top of the wood should be 1/2"
higher than the top of the storm window frame
or the vinyl frame.
Attach securely with nails or screws provided
by the installer.
1/2" higher
than storm
window
frame
1/2" higher
than vinyl frame
_ (on some windows)
Stool
Storm window
frame
Vinyl frame
Wood
9
[] REMOVE THE AIR CONDITIONER FROM
THE CASE
[] Remove and save the 2 screws from the lower
sides of the front grille.
FRONT
r_ Grasp the lower corners of the grille while
pressing in on the case sides with your finger
tips. Pull out to release and lift it up.
NOTE: Do not pull the bottom edge toward you
more than 3" or you may damage the tabs of
the grille.
t t
FRONT
[] When the front grille is removed the control
panel will still be attached by a harness.
Window Installation Instructions
r_ REMOVE THE AIR CONDITIONER
FROM THE CASE (CONT.)
rD'] Slide the air conditioner from the case by
gripping the base pan handle and pulling
forward while bracing the case. Do not pull or
lift on the styrofoam discharge area.
Do not
pull or
lift inthis
damage
to the
unit may
result
FRONT
I_ INSTALL THE BOTTOM CASE SEAL
, Peel the backing from the bottom case seal
and attach it along the bottom of the case in
front of the bottom mounting rail.
Bottom
mounting rail
/
Bottom case seal
10
rs] INSTALL THE TOP MOUNTING RAIL
ONTO THE CASE
Attach the top mounting rail onto the top of the
case with 3 Type B screws.
Press firmly to drive the screws into the gasket
and through the top mounting rail.
_e B
screws
[_ INSTALL THE SIDE ACCORDION
PANELS
[] Slide the left and right accordion panels into
the top and bottom mounting rails.
r_ Attach the accordion panels to the case using 3
Type A screws on each side.
Top mounting rail
TypeA
screws
\\
\\
BACK
Bottom mounting rail
Window Installation Instructions
r_ INSTALL THE CASE IN THE WINDOW
r_ open the window and mark the centerline of the
window stool.
r_ Carefully place the case on the window stool and
align the center murk on the bottom front with the
centerline of the stool.
r_ Pull the window down behind the top mounting rail.
NOTE:Do not shut the window so tightly that movement
of the accordion panels is restricted.
[] Select the position that will place the sill supports
near the outermost point on the sill. Placethe short
sideof the sill supports, on the case bottom, toward
the window. Attach the sill supports to the case track
hole in relation to the selected position using 2 Type
B screws in each support.
A CAUTION: Donotinstallthisair
conditioner in e window if the bolts do not contact
the window sill.
I I
\
Longsideof
sillsupports
OUTSIDE
[] Adjust the bolt and the nut in each support so that
the case is installed with a slight tilt to the outside.
Use a level; no more than 1/2 bubble will be the
correct case slant to the outside.
A CAUTION: _fthesill supportboltsdo
notcontoctthewindow sillorifyou hoveo window
withouto sillyou must orderoccessorykitRAK87 to
properlyinstallthisoirconditioner.Coll800.626.2002
orvisitGEApplionces.com.
171INSTALL THE CASE IN THE WINDOW
(CONT.)
r_ Secure the case to
the window stool
by using ] Type D
screws.
Sill
support
Pullthe accordion
panels to each window
sash track. Attach them
on each side to the
window sash and the
window stool using 4
Type Cscrews.
B1
B]
SECURE THE CASE IN THE WINDOW
AND INSTALL THE FOAM TOP
WINDOW GASKET
CAUTION:
To prevent broken glass Vinyl
or damage to windows,
on vinyl or other similarly
constructed windows,
attach the support bracket
to the window side jam.
Attach the window
locking brackets (on one
each side) with Type C
screws.
Cut the foam top window gasket to the window
width.
Stuff the foam
between the glass
and the window
to prevent air
and insects from
getting into the
room.
NOTE: If the gasket supplied does not fit your
window, obtain appropriate material locally to
provide a proper installation seal.
11
Window Installation Instructions
@
%
INSTALL THE AIR CONDITIONER IN
THE CASE
Slidethe air conditioner into the case by the base
pan. Do not push on the controls, styrofoam air
discharge housing or the finned coils. Make sure the
air conditioner isfirmly seated.
Do not presson
these ureas-
damage to the unit
may result
BasePan
Replace the 2 screws removed earlier, one on each
side of the case.
IMPORTANT: THE GROUND SCREWS MUST BE
REINSTALLED TO ENSURE PROPER GOUND.
[] INSTALL THE AIR CONDITIONER IN
THE CASE (CONT.)
rc] Attach the front grille to the case by inserting the
tabs on the grille into the slots on the front top of
the case. Push the grille in.
@
Secure the front grille to the case by replacing the
2 screws removed earlier. Press on the top of the
grille to help with side screw installation.
r_ Connect power.
12
Through-the-Wall Installation Instructions-Optional
The case may be installed through-the-wall in
both existing and new construction.
Read completely, then follow step-by-step.
NOTE: Obtain all materials locally for mounting
the air conditioner through-the-wall.
1_1IMPORTANT
[]
@
Through-the-wall installation is not appropriate
if any of the side or top louvers in the case will
be obstructed by the wall.
All side and top louvers in the case must project
on the outdoor side of the wall.
The room side of the case must project into the
room far enough to maximize the balance of the
unit.
The case must be installed level from side-to-
side and with a slight tilt from front to rear. Use
a level; no more than a 1/2 bubble will be the
correct case slant to the outside.
Lintel angle is required to support bricks or
blocks above opening.
Flashing is required and should extend the
length of the opening to ensure no inside cavity
leakage occurs.
Remove the air conditioner from the case.
For specific instruction, refer to the Window
Installation Instructions.
Make certain that a wall receptacle is available
close to the hole location or make arrangements
to install a receptacle.
:i
', i÷_.
[] Place the case in the wall opening and place wood
support strips between the case bottom and the
flashing on both sides of the bottom rail. They
should be the same height as the bottom rail and
the same length as the wall opening.
m IMPORTANT (cont.)
r_ Secure with 14 wood screws anchored at least an
inch into the wall support structure.
NOTE: Drill pilot holes, if necessary, for proper
installation. If the frame is oversized, use shims to
prevent case distortion.
13
FINISH THE WALL OPENING
Caulk all four sides on the outdoor side of the case
to prevent moisture from getting through to the
interior wall. Use of flashing (drip rail) will further
prevent water from dripping inside the wall and
down the outside of the building.
Place the air conditioner into the case.
Lintel angle
Plaster line
Caulking Trim molding (if
desired)
OUTSIDE
Air louvers (top j
and sides must/_
projecton thev
outdoor side of
the wall)
INSIDE
Bottom rail
J
Wood filler and
caulking (above an
below the flashinc
Flashing
(Drip rail)
Bottom
rail
Flashing
(Drip rail)
Wood support strips
r_ For specific instruction, refer to the Window
Installation Instructions.
Before you call for service...
Troubleshooting Tips
Save time and money! Review the chart below
first and you may not need to call for service.
Passible Causes What To Do
Air conditioner The air conditioner Hake surethe air conditioner plug ispushed completely
does notstart is unplugged into the outlet.
The fuse isblown/circuit Checkthe housefuse/circuit breaker boxand replace
breaker istripped the fuse or reset the breaker.
Power failure The unit will automatically re-start in the settings last
usedafter the power isrestored.
There is a protective time delay (approximately
3 minutes) to prevent tripping of the compressor
overload. Forthis reason, the unit may not start
normal cooling or heating for 3 minutes after it
isturned back on.
The current interrupter
device is tripped
Pressthe RESETbutton located on the power cord plug.
If the RESETbutton will not stay engaged, discontinue
useof the air conditioner and contact a qualified service
technician.
Air conditioner Ice blocks the air flow Setthe mode control at Fan Only or Hi Coolwith the
freezing up and stops the air conditioner temp control at a warmer setting.
from cooling the room
Air conditioner does not Airflow isrestricted • Hake surethere are no curtains, blinds or furniture
cool as it should blocking the front of the air conditioner.
The temp control may Turn the temperature knob clockwise asfar as possible.
not be set correctly
The air filter isdirty Cleanthe filter at least every 30 days.Seethe Operating
Instructions section.
The room may have been hot • When the air conditioner isfirst turned on you need
to allow time for the room to cool down.
Cold air is escaping Checkfor open furnace floor registersand
cold air returns.
Setthe air conditioner's vent to the closed position.
Cooling coils have iced up See"Air conditioner freezing up" above.
Air conditioner does not Airflow isrestricted • Hake surethere are no curtains, blinds or furniture
warm us itshould blocking the front of the air conditioner.
The temp control moy .Turn the knob counterclockwise as far as possible.
not be set low enough Thelowest setting provides maximum warming.
The air filter isdirty Cleanthe filter at least every 30 days.Seethe Operating
Instructions section.
The room may have been cold When the air conditioner isfirst turned on,you need to
allow time for the room to warm up.
Warm air isescaping Checkfor open furnace floor registersand
cold air returns.
14
Before you call for service...
Troubleshooting Tips
GEAppliances.com
Possible Causes What To Do
Water drips outside Excessively hot and This is normal.
humid weather
Water drips indoors The air conditioner is not For proper water disposal, make sure the air conditioner
tilted to the outside slants slightly from the case front to the rear.
Water collects in
base pan
Moisture is removed from
indoor air and drains into
rear of a cabinet where a fan
blows it against the outdoor
condenser coil
Thisisnormal for a short period in areaswith
little humidity; normal for a longer period in very
humid areas.
15
Notes.
16
GE Air Conditioner--One-Year Limited Warranty. {Forcustomers intheU.S.A.)
All warranty service provided by our Factory Service Centers,
or an authorized Customer Core_ technician. To schedule
service, visit us on-line at GEAppliances.com, or call 800.
GE.CARES(800.432.2737). Have serial number and model
number available when calling for service.
Staple your receipt here.
Proof of the original purchase
date is needed to obtain
service under the warranty.
One Year
From the dU{eOfthe
0rigin0! purchase
GE Will Replace:
Any part of the air conditioner which fails due to a defect in materials or workmanship
Duringthis limited one-year warranty, GEwill also provide, free of charge, all labor and related
serviceto replacethe defective part
Service trips to your home to teach you how to use the
product.
Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner is of
improper cooling capacity for the intended use, contact
your dealer or installer. Youare responsible for providing
adequate electrical connecting facilities.
Failure of the product resulting from modifications to the
product or due to unreasonable use including failure to
provide reasonable and necessary maintenance.
Incommercial locations, labor necessary to move the
unit to a location where it is accessible for service by an
individual technician.
Replacement of house fuses or resetting of circuit breakers.
Failure due to corrosion on models not corrosion-protected.
Damage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by possible
defects with this air conditioner.
Damage caused affer delivery.
EXCLUSION OF IMPLIED WARRANTIES--Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness
for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available,
you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE
Service location for service. In Alaska, the warranty excludes the cost of shipping or service cells to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. To know what your
legal rights are, consult your local or state consumer affairs office or your state's Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
17
GE Air Conditioner--One-Year Limited Warranty. (For customers in the Canada)
All warranty service provided by our Factory Service Centers,
or an authorized Customer Care_ technician. For service, call
1.800.561.3344. Please have serial number and model number
available when calling for service.
Staple your receipt here.
Proof of the original purchase
date is needed to obtain
service under the warranty.
One Year
From the date of the
original purchase
Mabe Will Replace:
Any part of the air conditioner which fails due to a defect in materials or workmanship.
Duringthis limited one-year warranty, Mabewill also provide, free of charge, all labor and
related serviceto replace the defective part.
Service trips to your home to teach you how to use the
product.
Improper installation, delivery or maintenance. If you
hove on installation problem, or if the air conditioner is of
improper cooling capacity for the intended use, contact
your dealer or installer. You ore responsible for providing
adequate electrical connecting facilities.
Failure of the product resulting from modifications to the
product or due to unreasonable use including failure to
provide reasonable and necessary maintenance.
In commercial locations, labor necessary to move the
unit to a location where it is accessible for service by an
individual technician.
Replacement of house fuses or resetting of circuit breakers.
Failure due to corrosion on models not corrosion-protected.
Damage to the product caused by improper power supply
voltage, accident, fire, floods or acts of God.
Incidental or consequential damage caused by possible
defects with this air conditioner.
Damage caused after delivery.
EXCLUSION OF IMPLIED WARRANTIES--Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness
for a particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased in Canada
for home use within Canada. In-home warranty service will be provided in areas where it is available and deemed
reasonable by Mabe to provide.
Some provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above
exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
which vary from province to province. To know what your legal rights are in your province, consult your local or
provincial consumer affairs office.
Warrantor: Mabe Canada Inc.,
Burlington, Ontario
18
Consignes de s6curit6 ............. 20,21
Consignes d'utilisation .............. 22,23
Entretien et nettoyage
Filtre (_air ................................ 23
Retrait du cadre de la grille ............... 23
Serpentins ext#rieurs ..................... 23
Instructions de montage
Instructions de montage pour une
installation (_travers un mur--En option ...... 30
Instructions de montage
dans une fen#tre ..................... 25-29
Conseils de d_pannage .............. 33
Service _ la clientele
Service 5 la clientele ....................... 36
Garantie .................................. 35
Enregistrement du titre
de propri#t# ........................... 3Z, 32
AEE08
AEEf2
Inscrivez ici les num6ros de module et de s6rie:
Num6ro de module:
Num6ro de S6rie:
Vous trouverez ces num6ros sur 1'6tiquette appos6e
sur le c6t# du climatiseur.
Au Canada, visitez-nous au:
www.electromenagersge.ca
19
J
IMPORTANTES CONSIGNES DE SECURITE.
VEUILLEZ LIRE TOUTES LES CONSIGNES AVANT UTILISATION.
20
AVERTISSEMENT !
Pour votre s6curit6, les informotions contenues duns ce manuel doivent @re suivies afin de minimiser
les risques d'incendie, de chocs 61ectriques ou de blessures corporelles.
CONSIGNESDESECURITE
N'utilisez cet opporeil qu'uux fins pr6vues
d6crites dons le manuel d'utilisotion.
Ce climutiseur doit 6tre correctement install6
conform6ment aux Instructions d'lnstollotion
ovont toute utilisotion.
Ne d6brunchezjamuis votre climotiseur en tiront
sur le cordon d'alimentotion. Prenez toujours
fermement Iofiche en main et tirez pour Iosortir
de lu prise.
Remplacezimm6diotementtoutcordon61ectrique
us6 ou endommag6. Un cordon d'alimentotion
endommug6 doit @rerempluc6 par un nouveau
cordon d'ulimentution obtenu du fobricunt.
Ne r6purez pus le cordon endommug6.
N'utilisez pus un cordon fissur6 ou pr6sentunt
des dommuges dus uux frottements soit sur
so Iongueur ou uux extr6mit6s du c6t6
de lu fiche ou du ruccord.
Sila prise de couront est d'un format diff@ent
de la fiche, cette prise doit 6tre chang6e par un
61ectricien quolifi6.
Eteignez votre climatiseur et d6branchez-
le uvont d'effectuer des r6parations ou de
le nettoyer.
REMARQUE: Nous vous recommandons
de faire effectuer la maintenance par un
technicien qualifi_.
Pour votre s6curit6, ne stockez poset n'utilisez
pus de mut@iuux combustibles, d'essence ou
d'outres vopeurs et liquides inflammables duns
les potages de cet opporeil ou de tout outre
opporeil.
Tous les climatiseurs contiennent des
fluides frigorig_nes qui, conform6ment, _ la
16gislation f6d6rale doivent @tre retir6s avant
Io mise au rebut de I'appareil. Si vous mettez
au rebus un ancien opporeil contenant des
fluides frigorig@nes, v6rifiez la proc6dure 6
suivre aupr@sde la compagnie responsable de
1'61imination.
Cessyst@mesde climatisation R410Ademandent
que les contracteurs et les techniciens utilisent
des outils, de 1'6quipement et des mesures de
s6curit6 homologu6s pour une utilisation avec
frigorig_ne. N'UTILISEZ PAS un 6quipement
certifi6 pour fluide R22 refrigerant only.
BRANCHEMENTSI LECTRIOUES
Ne coupez pas ou n'enlevez pas, sous aucun
pr6texte, Io troisi@me broche de mise _ la terre
du cordon d'alimentation. Pour des raisons
de s6curit6, cet appareil doit @re correctement
mis _ la terre.
N'utilisez PASd'adaptateur avec cet appareil.
Le cordon d'alimentation de cet appareil
est 6quip6 d'une fiche _ trois broches (pour
une mise 8 la terre) qui s'adapte 8 la prise
de courant standard _ 3 broches (pour une
mise 8 la terre) pour minimiser les risques
de chocs 61ectriques par cet appareil.
Le cordon d'alimentation est 6quip6 d'un dispositif
d'interruption du courant. Un bouton d'essai et de
r6enclenchement est fourni sur le boYtierde la prise.
Vous devez tester le m6canisme r6guli@ement en
appuyantd'abordsurle boutonTEST(Essai) puis sur le
bouton RESET(R6enclenchement)Iorsque I'appareil
est branch6. Sile bouton TEST(Essai)ne bascule pas
ou si le bouton RESET(R6enclenchement) ne reste
pas enclench6, cessez d'utiliser votre climatiseur
et appelez un technicien de service qualifi6.
Faites v6rifier la prise murale et le circuit
61ectrique par un 61ectricien qualifi6 pour
s'assurer que le syst_me est correctement
mis 6 la terre.
Dans le cos d'une prise biphas6e,
I'instollateur a la responsabilit6 et I'obligation de la
remplocer par une prise triphas6e correctement
mise 5 la terre.
Le climatiseur doit toujours @tre branch6
so propre prise 61ectrique d'une tension
nominale correspondont 5 celle indiqu6e
sur so plaque signal@ique.
Ceci permet d'obtenir un meilleur rendement
du climatiseur et _vite de surcharger les circuits
_lectriques du domicile qui risque d'occasionner un
incendie en surchauffant.
Consultez les Consignes d'lnstallations, dons
la section Exigences Electriques pour les exigences
de branchements _lectriques particuliers.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

GE AEE08ATL1 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI