Dormakaba RCI 972 All-in-One Illuminated Installation guide

  • Hello! I've read the installation instructions for the dormakaba 9 Series RCI 972 Illuminated Pushbutton. This document covers installation, LED voltage adjustments, message tag changes, and power requirements. I am ready to answer your questions about the device and its installation procedures. Feel free to ask about the back box requirements, LED connections, or message tag replacement.
  • What back box depth is required?
    How do I change the LED voltage?
    What should I do if the bulb does not light?
    How do I change the message tag?
INSTALLATION
RCI 972
9 SERIES ILLUMINATED PUSHBUTTON
© 2022 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]IS972
PCN2208
R11-22GR
Instruction
A 2-1/4” (57mm) deep back box is required. Match your message color with lens cap color and snap into the housing. Slide connec-
tors onto the terminals as shown.
To change the LED voltage, slightly turn the white lamp holder in a counterclockwise direction to release from the black housing and
pull it out. Change LED cluster as desired and re-turn the lamp holder back into place.
Connect appropriate 12 or 24 VDC supply voltage to the LED terminals on each side of the switch.
Remember that the LED (+) positive and (-) negative terminal is determined by the lamp position in the base.
If bulb does not light, reverse position of leads.
To change the message tag, remove the lamp holder as described above and then pinch the white tabs to release the lens cap. Be
careful not to lose the spring. Insert your thumbnail between the corner of the lens cap and white extension and then slide it along
the edge to separate the cap. Tap the cap to remove the message tag.
NOTE: Overheated / melted components caused by incorrect input voltage not be covered under warranty.
Bulb Voltage Current Draw
LED 12VDC 20mA
LED 24VDC 10mA
Switch Rating
Cycle Rating: 10,000
Contacts Rated 16 amps @ 125VAC
LAMP HOLDER NC TERMINAL
(RED)
NO TERMINAL
(GREEN)
COM TERMINAL
(BLACK)
LAMP TERMINAL
EACH SIDE
(2 X YELLOW)
LED CLUSTER
BUTTON HOUSING
LENS CAP 2" LENS CAP
MESSAGE – 2" SQUARE TAG
Power Requirements
/