Aquatic 1363BFC2P Operating instructions

Category
Faucets
Type
Operating instructions
— 1 —
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
Items Included
Shower
Tools Needed
ADA/ANSI COMPLIANT BARRIER-FREE SHOWER STALLS
For roll-in showers with a flat threshold, build up or recess the bathroom floor 3/4” less the thickness of the finished floor. For beveled
thresholds, build up or recess the bathroom floor 3/4” less the thickness of the finished floor, ensuring that the finished floor meets the
base of the bevel at the threshold.
It is recommended that the bathroom floor outside ADA clear floor space be designed with a floor drain to alleviate any water over spray
that may escape the shower stall.
Product illustration may not be
representative of your unit.
3/16” Drill Bit
3-1/2” Drill Bit
1” Drill Bit
Phillips Screw Bit
#8 X 1”
Pan Head Screws
100% Mildew Resistant
Silicone Sealant
Square
Notched Trowel
(For use on non-level
floor applications only.)
Level
Hammer
Tape Measure
Drill
Aquatic products may be specified as Lasco Bathware.
— 2 —
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
NOTICE: Please inspect the unit thoroughly before installation to make sure it has not been damaged during transportation.
Under no circumstances should a damaged unit be installed. Neither Aquatic nor the distributor will be responsible for removal or
reinstallation costs should a replacement be necessary due to installation of a damaged unit.
PRE-INSTALLATION PLANNING
1. Unit must be placed within bathroom area before completion of door framing or, if preferred, studs may be omitted or knocked-
out to permit unit placement.
2. Review job print and Aquatic rough-in dimensions; verify all key dimensions against actual job conditions .
3. Make sure framed-in alcove is of proper size, square and plumb; check floor for levelness.
4. If alcove floor is not completely level, foundation materials [non-shrink grout] are mandatory under the bottom of each unit to
solidify for wheelchair support.
5. If fire-rated alcove is required, approved finish material must be in place prior to unit installation to meet fire safety requirements
of local building code and/or FHA/HUD Minimum Property Standards.
NOTE: Finished alcove must have interior dimensions
shown on rough-in diagram to permit installation of unit.
6. Provide 8” x 8” (205mm x 205mm) box out for 2” (50mm) IPS and drain connection.
7. To avoid obstruction, make sure that supply lines and valve plumbing are not strapped to studs and do not project into
alcove. Also, drain pipe must not project above floor level prior to installation.
8. Make sure all plumbing is complete and to code.
9. To prevent scuffing while installing unit, cover the entire bottom of the unit with a piece of cardboard or other protective material.
10. Fasten drain fitting to unit before installing [see manufacturer’s instructions].
Fasteners for wood framing—1
1
2” galvanized roofing nails or #10 x 1
1
2” self-tapping washer head screws;
for concrete or block walls—1” concrete nails and nailing tool;
for steel studs (18 ga.)—drill flanges and studs with
5
32” carbide bit and use #12 x 1 sheet metal screws.
INSTALLATION PROCEDURE
For non-level alcove floor applications, prepare a foundation material mix
(industrial plaster, mortar mix) and spread throughout the alcove floor with a square
notched tile trowel. The foundation materials should spread around the drain and
extend to the perimeter of the shower floor.
8“ x 8”
(205mm x 205mm)
Box Out
Rough In
Rough
Center
Overall Width
Overall
Depth
1
Foundation Material
8” Box Out
Square
Notched Trowel
2
Note: If fire-rated alcove is required, approved finish materials must be in place
prior to unit installation to meet fire safety requirements of local building codes
and/or FHA/HUD Minimum Property Standards.
Check dimension of alcove; make sure walls are square and plumb and floor is
level. For completely level floor, proceed to Step 3.
— 3 —
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
3 4
8” Box Out
5
Mark fitting locations. (Refer to measurements from step 3.) Using a hole saw (fine
tooth or abrasive grit cutting edge), make necessary openings for filler and valves,
drilling from inside (smooth side) out.
If mounting fittings — from stable reference points (back wall studs, floor)
measure the locations of spout and valves. Note measurements.
INSTALLATION PROCEDURE, CONT.
Check for level. Check for proper floor slope (1/4” per foot) by placing level in
locations shown above and measuring slope along the length of the level.
6
7 8
Fasten vertical nailing flanges to studs starting from the floor, moving upward
every 8 inches. Fasten horizontal nailing flanges at every stud.
Cover the entire bottom of the unit with a piece of cardboard or other protective
material. Pre-drill pilot hole and fasten the center of the back nailing flange to
stud to secure unit in place. Once secured proceed by pre-drilling pilot holes
and fastening unit to floor starting in the center of the base flange, moving
outward every 8 inches.
Place the unit directly on level floor (or on top of foundation materials) with drain
fitting over and onto waste pipe with threshold firmly on the floor. A
ssure waste
pipe protrudes well into drain fitting. Maintain proper floor slope towards drain.
Level Placement
— 4 —
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
9. Make final connections to supply lines and waste pipe in accordance with plumbing code requirements. Strap water lines and
valve/s to studs.
10. Water test for proper drainage.
CLEAN-UP
1. Do not remove warranty/maintenance adhered label.
Leave on unit for owner/occupant per code requirement.
2. Prevent staining. Remove all debris before plumbing leak test. Use sponge with warm water and liquid detergent. Rinse, drain and wipe
clean. Do not use abrasive cleansers such as scouring powders, steel wool, metal scrapers, sand paper or anything else that might mar,
dull or scratch the finish.
3. Plaster and latex paint may be removed with warm water, liquid detergent and brittle brush or plastic scraper. Glues, tars and enamels
may be removed with acetone or paint thinner. Do not use turpentine or laquer thinner. Do not use excessive heat or any caustic solvents
or chemicals.
4. Dull areas and light scratches may be removed by buffing with a light colored automotive rubbing compound and buffing pad. Entire unit can be
waxed with light colored automotive wax. Do not wax bottom of unit.
5. See user maintenance label for more details.
USER MAINTENANCE INSTRUCTIONS
IMPORTANT! Use only recommended cleaners and procedures described herein. Use of other materials and methods may damage
your bath fixture and void the warranty.
1. For normal cleaning: Never use abrasive cleaners such as scouring powders or pads, steel wool, scrapers, sandpaper or anything else that
could scratch or dull the surface of your Aquatic unit. Instead, use warm water and liquid detergents or non-abrasive cleansers, especially
those bathroom cleaners recommended for cleaning fiberglass.
2. To keep your Aquatic bath fixture sparkling clean: Apply a coat of good quality automotive paste wax or polish and buff to a high shine
with a soft cloth or towel. Repeat every six months for easier cleaning and long lasting protection.
NOTE: DO NOT WAX textured, slip-resistant standing surface of the unit bottom. This could result in greater risk of slipping and personal injury.
3. To restore a scratched or dull unit: Use an automotive polishing compound applied with a clean cotton rag. Rub scratches and dull areas
vigorously. Wipe off residues. Follow with automotive wax treatment described above.
4. To remove adhesive: Try 3-M Natural Cleaner, De-Solv-It or similar materials. If residues remain, saturate a small, white, cotton rag with
nail polish remover (naphtha or acetone) and rub vigorously until the adhesive dissolves and disappears. These solvents are highly
flammable and must be used sparingly and with caution. Do not smoke or permit others to do so. Make sure all nearby heating devices
(including pilot lights) are extinguished. Do not allow solvent to go down the drain. Make sure not to contact plastic drain grates or other
synthetic materials.
5. Rubber Mats: If you use a rubber “anti-skid” mat, make sure to remove it from the unit after each use to avoid harm to the surface finish.
6. Hard Water: Water in certain regions, if not wiped up after bathing/showering, may cause fading of some bath fixture colors. This is a
natural occurrence beyond Aquatic ’s control. (See Warranty)
CAUTION: When using any cleaning or polishing materials, make sure to read and follow all package instructions carefully. Wear
rubber gloves at all times and avoid contact with eyes, skin, clothing, rugs and furnishings. Make sure all residues are rinsed off thoroughly.
1521 No. Cooper, Ste. 500
Arlington, TX 76011
PH: 800-945-2726, 817-801-8300
FAX: 866-544-5353
Customer Service | Technical Services | Warranty Services
LITID2907
— 12 —
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 •
TÉLÉCOPIEUR
(714) 998-5340 • www.aquaticbath.com
1521 No. Cooper, Ste. 500
Arlington, TX 76011
Tél.: 800-945-2726, 817-801-8300
TÉLÉCOPIEUR: 866-544-5353
Service à la clientèle
|
Services techniques
|
Services de garantie
LITID2907
Instructions d’installation
Cabines de douche accessibles avec base au niveau
Télécopie sur demande nº
2907
9. Terminer d’établir les raccords aux conduites d’alimentation et au tuyau d’évacuation en respectant la réglementation concernant la
plomberie. Fixer les conduites d’eau et la ou les valves aux montants.
10. Faites couler de l’eau pour vérifier qu’elle s’écoule correctement.
NETTOYAGE
1. Ne retirez pas l’étiquette autocollante de garantie/entretien. Laissez-la sur l’unité pour le propriétaire/occupant, afin de satisfaire
aux exigences du Code.
2. Évitez les taches. Retirez tous les débris avant de tester la plomberie pour des fuites. Utilisez une éponge, de l’eau tiède et un
détergent liquide. Rincez, laissez égoutter et essuyez. N’utilisez pas de nettoyants abrasifs comme les poudres à récurer, la laine
d’acier, les grattoirs métalliques, le papier abrasif ou quoi que ce soit pouvant marquer, abîmer le lustre ou érafler le fini.
3. Le plâtre et les taches de peinture peuvent être enlevés avec de l’eau tiède, un détergent liquide et une brosse douce ou un grattoir
de plastique. Les taches de colle, goudron et émail peuvent être enlevées avec de l’acétone ou un diluant pour peinture. N’utilisez
pas de térébenthine ou de diluant à peinture-laque. Évitez la chaleur excessive et tout solvant caustique ou chimique.
4. Les zones délustrées et petites éraflures peuvent être effacées par polissage avec une pâte à polir pour automobile de couleur
claire et un tampon à lustrer. L’unité entière peut être polie avec de la cire automobile de couleur claire. Ne pas cirer le fond de la
douche.
5. Reportez-vous à l’étiquette d’entretien de l’utilisateur pour obtenir plus de détails.
INSTRUCTIONS D’ENTRETIEN PAR L’UTILISATEUR
IMPORTANT! Ne suivez que les procédures et n’utilisez que les nettoyants recommandés décrits dans ce document. L’utilisation d’autres fournitures,
produits et méthodes pourrait endommager votre accessoire de bain et annuler la garantie.
1. Pour un nettoyage normal: N’utilisez jamais de nettoyants abrasifs comme des poudres ou tampons à récurer, de la laine d’acier,
des grattoirs métalliques, du papier abrasif ou quoi que ce soit pouvant marquer, abîmer le lustre ou érafler le fini de votre unité
Aquatic. En revanche, utilisez de l’eau tiède et des détergents liquides ou non abrasifs, en particulier les produits de nettoyage pour
salle de bain recommandés pour nettoyer la fibre de verre.
2. Pour garder votre accessoire de salle de bain Aquatic d’une propreté étincelante: appliquez une couche de cire en pâte ou poli
pour automobile de bonne qualité et lustrez avec une serviette ou un chiffon doux pour le rendre brillant. Répétez tous les six mois
pour faciliter le nettoyage et prolonger la protection.
REMARQUE: NE CIREZ PAS la surface antidérapante texturée du fond de l’unité où l’on se tient debout. Cela pourrait augmenter
les risques de chutes et de blessures.
3. Pour restaurer une unité éraflée ou abîmée: appliquez de la pâte à polir pour automobile au moyen d’un chiffon propre en coton.
Frottez vigoureusement les éraflures et les zones abîmées. Retirez les résidus. Appliquez ensuite la cire pour automobile, comme
indiqué ci-dessus.
4. Pour enlever l’adhésif: essayez le nettoyant naturel 3-M, le De-solv-it ou des produits comparables. Si vous n’arrivez pas à éliminer
tous les résidus, enduisez un petit chiffon blanc en coton de dissolvant à ongles (naphta ou acétone) et frottez vigoureusement
jusqu’à ce que l’adhésif se dissolve et disparaisse. Ces dissolvants sont très inflammables et ils doivent être utilisés avec prudence et
modération. Ne fumez pas et n’autorisez personne à fumer à proximité. Assurez-vous que tous les appareils chauffants à proximité
(y compris les veilleuses) sont éteints. Ne laissez pas couler de dissolvant dans la canalisation. Veillez à ce que le dissolvant n’entre
pas en contact avec les grilles de canalisation en plastique ni aucun autre matériau synthétique.
5. Paillassons de caoutchouc: si vous utilisez un tapis de caoutchouc antidérapant, assurez-vous de l’enlever de l’unité après chaque
utilisation afin d’éviter d’endommager le fini.
6. Eau dure: dans certaines régions, l’eau peut causer la décoloration des surfaces si elle n’est pas essuyée après le bain ou la
douche. Il s’agit d’un phénomène naturel ne dépendant pas d’Aquatic. (Reportez-vous à la Garantie)
ATTENTION: lisez et suivez attentivement les instructions qui figurent sur l’emballage du produit nettoyant ou de la cire que vous utilisez. Portez des
gants en caoutchouc et évitez tout contact avec les yeux, la peau, les vêtements, les chiffons et le mobilier. Rincez soigneusement pour éliminer tous
les résidus.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Aquatic 1363BFC2P Operating instructions

Category
Faucets
Type
Operating instructions

Ask a question and I''ll find the answer in the document