Magnetek Flex 8 PRO User manual

Type
User manual

This manual is also suitable for

Flex Pro Transmitter
Radio Control Equipment
Instruction Manual
Part Number: 198-50003 R10
April 2019
©Copyright 2019 Magnetek Material Handling
Flex Pro Transmitter Instruction Manual
April 2019
Page 2 of 25
Page Intentionally Left Blank
Flex Pro Transmitter Instruction Manual
April 2019
Page 3 of 25
Table of Contents
1 Introduction.........................................................................................................................................7
2 Radio and Safety................................................................................................................................. 8
2.1 Critical Installation Considerations ............................................................................................... 9
2.2 General.........................................................................................................................................9
2.3 Persons Authorized to Operate Radio Controlled Cranes............................................................9
2.4 Safety Information and Recommended Training for Radio Controlled Equipment Operators....10
2.5 Transmitter Unit..........................................................................................................................11
2.6 Pre-Operation Test.....................................................................................................................11
2.7 Handling Batteries ...................................................................................................................... 11
2.8 Optional Rechargeable Battery Charging...................................................................................12
2.9 Battery Disposal ......................................................................................................................... 12
2.10 Crane/Lifting Device Specific Warnings .....................................................................................12
2.11 Specific System Warnings..........................................................................................................13
3 General System Information............................................................................................................14
3.1 External Illustration (Pro 12 Configuration) ................................................................................14
3.2 Internal Illustration (Pro 12 Configuration)..................................................................................15
3.3 Types of Buttons ........................................................................................................................ 16
3.4 Adjustable Speed Control (if equipped)......................................................................................16
4 Function Settings ............................................................................................................................. 17
4.1 System Channel Settings ...........................................................................................................17
4.2 Inactivity Time-Out Timer ...........................................................................................................19
4.3 I-CHIP.........................................................................................................................................19
5 Operating Procedure ........................................................................................................................ 20
5.1 General Operating Procedure ....................................................................................................20
5.2 Changing Transmitter Batteries..................................................................................................21
5.3 Status Lights Indicators and Warnings.......................................................................................22
5.4 Push Button Error Table.............................................................................................................23
5.5 Troubleshooting Tips..................................................................................................................24
6 Declaration of Conformity................................................................................................................ 25
Flex Pro Transmitter Instruction Manual
April 2019
Page 4 of 25
Page Intentionally Left Blank
Flex Pro Transmitter Instruction Manual
April 2019
Page 5 of 25
SERVICE CONTACT INFORMATION
Your New Radio Remote Control System
Thank you for your purchase of Magnetek’s Enrange™ Flex Pro radio remote control system. Without a
doubt, our Flex Pro system is the ultimate solution for providing precise, undeterred, and safe control of
your material.
If your product ever needs modification or service, please contact one of our representatives at the
following locations:
U.S. Service Information
For questions regarding service or technical information, contact:
1-866-MAG-SERV
(1-866-624-7378)
International Service
262-783-3500
World Headquarters:
Magnetek, Inc.
N49 W13650 Campbell Drive
Menomonee Falls, WI 53051
Telephone: 800-288-8178
Website: www.magnetek.com
E-mail: mhcustomerse[email protected]
Fax Numbers:
Main: 800-298-3503
Sales: 262-783-3510
Service: 262-783-3508
© 2019 MAGNETEK
All rights reserved. This notice applies to all copyrighted materials included with this product, including, but
not limited to, this manual and software embodied within the product. This manual is intended for the sole
use of the person(s) to whom it was provided, and any unauthorized distribution of the manual or dispersal
of its contents is strictly forbidden. This manual may not be reproduced in whole or in part by any means
whatsoever without the expressed written permission of MAGNETEK.
Canada Service Information:
161 Orenda Road
Unit 1
Brampton, Ontario
L6W 1W3 Canada
Phone: 800-792-7253
Fax: 905-828-5707
416-424-7617 (24/7 Service pager)
EU Market Contact:
Brian Preston
Magnetek (UK) Ltd.
Unit 3 Bedford Business Centre
Mile Road
Bedford, MK42 9TW UK
Phone: +44-1234-349191
Flex Pro Transmitter Instruction Manual
April 2019
Page 6 of 25
PREFACE AND SAFETY
Product Safety Information
Magnetek, Inc. (Magnetek) offers a broad range of radio remote control products, control products and
adjustable frequency drives, and industrial braking systems for overhead material handling applications.
This manual has been prepared by Magnetek to provide information and recommendations for the
installation, use, operation and service of Magnetek’s material handling products and systems (Magnetek
Products). Anyone who uses, operates, maintains, services, installs or owns Magnetek Products should
know, understand and follow the instructions and safety recommendations in this manual for Magnetek
Products.
The recommendations in this manual do not take precedence over any of the following requirements
relating to cranes, hoists and lifting devices:
Instructions, manuals, and safety warnings of the manufacturers of the equipment where the radio
system is used,
Plant safety rules and procedures of the employers and the owners of facilities where the
Magnetek Products are being used,
Regulations issued by the Occupational Health and Safety Administration (OSHA),
Applicable local, state or federal codes, ordinances, standards and requirements, or
Safety standards and practices for the overhead material handling industry.
This manual does not include or address the specific instructions and safety warnings of these
manufacturers or any of the other requirements listed above. It is the responsibility of the owners, users
and operators of the Magnetek Products to know, understand and follow all of these requirements. It is the
responsibility of the employer to make its employees aware of all of the above listed requirements and to
make certain that all operators are properly trained. No one should use Magnetek Products prior to
becoming familiar with and being trained in these requirements and the instructions and safety
recommendations for this manual.
Product Warranty Information
Magnetek, hereafter referred to as Company, assumes no responsibility for improper programming of a
device (such as a drive or radio) by untrained personnel. A device should only be programmed by a trained
technician who has read and understands the contents of the relevant manual(s). Improper programming
of a device can lead to unexpected, undesirable, or unsafe operation or performance of the device. This
may result in damage to equipment or personal injury. Company shall not be liable for economic loss,
property damage, or other consequential damages or physical injury sustained by the purchaser or by any
third party as a result of such programming. Company neither assumes nor authorizes any other person to
assume for Company any other liability in connection with the sale or use of this product.
WARRANTY INFORMATION
FOR INFORMATION ON MAGNETEK’S PRODUCT WARRANTIES BY PRODUCT TYPE, PLEASE
VISIT WWW.MAGNETEK.COM.
Flex Pro Transmitter Instruction Manual
April 2019
Page 7 of 25
1 Introduction
The Flex radio remote control systems are designed for control of industrial equipment and mobile
machinery such as overhead traveling cranes, construction equipment, forestry equipment, mining
equipment, rail equipment, drilling and trenching equipment, agriculture equipment, electric hoists,
winches, monorails, conveyor belts, mining equipment and other material handling equipment where
wireless control is preferred.
Each Flex system consists of a transmitter handset and standard-equipped accessories such as a
transmitter waist belt, spare transmitter power key, clear vinyl pouch, “AA” alkaline batteries, compass
direction decal sheet and user’s manual.
Notable features include:
32 user-programmable channels – Advanced synthesized RF controls with 32 built-in channels;
there are no fixed channel and fragile quartz crystals to break.
Over 1 million unique ID codes (20-bit) – Each and every Flex system has its own unique ID
code; no repeats.
Advanced controlsThe Flex system uses advanced microprocessor controls with 16-bit CRC,
which provides ultra-fast, safe, precise, and error-free encoding and decoding.
Unique I-CHIP design – The I-CHIP functions in a way that is very similar to SIM cards used on
mobile phones, with the ability to transfer system information and settings from one transmitter to
another without the hassle of resetting the spares.
Reliable push buttons – The in-house designed push buttons are rated for more than 1 million
press cycles.
Low power consumption – Requires only two “AA” alkaline batteries for more than 100 hours of
operating time between replacements.
Ultra-durable nylon and fiberglass composite enclosures – Highly resistant to breakage and
deformation even in the most abusive environments.
Full compliance – All systems are fully compliant with the FCC Part-15 Rules, European
Directives (Safety, EMC, RED, and Machinery), and Industry Canada Specifications (IC).
Flex Pro Transmitter Instruction Manual
April 2019
Page 8 of 25
2 Radio and Safety
WARNINGS and CAUTIONS
Throughout this document WARNING and CAUTION statements have been deliberately placed to
highlight items critical to the protection of personnel and equipment.
NOTE: A NOTE statement is used to notify people of installation, operation, programming, or
maintenance information that is important, but not hazard-related.
WARNINGS and CAUTIONS SHOULD NEVER BE DISREGARDED.
The safety rules in this section are not intended to replace any rules or regulations of any applicable local, state, or
federal governing organizations. Always follow your local lockout and tagout procedure when maintaining any radio
equipment. The following information is intended to be used in conjunction with other rules or regulations already in
existence. It is important to read all of the safety information contained in this section before installing or operating the
Radio Control System.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury. It may also be used to alert against unsafe practices.
Flex Pro Transmitter Instruction Manual
April 2019
Page 9 of 25
2.1 Critical Installation Considerations
2.2 General
Radio controlled material handling equipment operates in several directions. Cranes, hoists, lifting devices
and other material handling equipment can be large and can operate at high speeds. The equipment is
often operated in areas where people are working in close proximity to the material handling equipment.
The operator must exercise extreme caution at all times. Workers must constantly be alert to avoid
accidents. The following recommendations have been included to indicate how careful and thoughtful
actions may prevent injuries, prevent damage to equipment, or even save a life.
2.3 Persons Authorized to Operate Radio Controlled
Cranes
Only properly trained persons designated by management should be permitted to operate radio controlled
equipment.
Radio controlled cranes, hoists, lifting devices and other material handling equipment should not be
operated by any person who cannot read or understand signs, notices and operating instructions that
pertain to the equipment.
WARNING
Prior to installation and operation of this equipment, read and develop an understanding of the contents
of this manual and the operation manual of the equipment or device to which this equipment will be
interfaced. Failure to follow this warning could result in serious injury or death and damage to
equipment.
All equipment must have a mainline contactor installed and all tracked cranes, hoists, lifting devices
and similar equipment must have a brake installed. Failure to follow this warning could result in serious
injury or death and damage to equipment.
An audible and/or visual warning means must be provided on all remote controlled equipment as
required by code, regulation, or industry standard. These audible and/or visual warning devices must
meet all governmental requirements. Failure to follow this warning could result in serious injury or
death and damage to equipment.
Follow your local lockout tagout procedure before maintaining any remote controlled equipment.
Always remove all electrical power from the crane, hoist, lifting device or similar equipment before
attempting any installation procedures. De-energize and tagout all sources of electrical power before
touch-testing any equipment. Failure to follow this warning could result in serious injury or death and
damage to equipment.
The direct outputs of this product are not designed to interface directly to two state safety critical
maintained functions, i.e., magnets, vacuum lifts, pumps, emergency equipment, etc. A mechanically
locking intermediate relay system with separate power considerations must be provided. Failure to
follow this warning could result in serious injury or death or damage to equipment.
Flex Pro Transmitter Instruction Manual
April 2019
Page 10 of 25
Radio controlled equipment should not be operated by any person with insufficient eyesight or hearing or
by any person who may be suffering from a disorder or illness that may cause them to lose control of the
equipment, is taking any medication that may cause loss of equipment control, or is under the influence of
alcohol or drugs.
2.4 Safety Information and Recommended Training for
Radio Controlled Equipment Operators
Anyone being trained to operate radio controlled equipment should possess as a minimum the following
knowledge and skills before using the radio controlled equipment.
The operator should:
have knowledge of hazards pertaining to equipment operation
have knowledge of safety rules for radio controlled equipment
have the ability to judge distance of moving objects
know how to properly test prior to operation
be trained in the safe operation of the radio transmitter as it pertains to the equipment being
operated
have knowledge of the use of equipment warning lights and alarms
have knowledge of the proper storage space for a radio control transmitter when not in use
be trained in transferring a radio control transmitter to another person
be trained how and when to report unsafe or unusual operating conditions
test the transmitter emergency stop and all warning devices prior to operation; testing should be
done on each shift, without a load
be thoroughly trained and knowledgeable in proper and safe operation of the equipment that
utilizes the radio control
know how to keep the operator and other people clear of hazardous areas
know and follow the local lockout and tagout procedures when servicing radio controlled
equipment
know and follow all applicable operating and maintenance manuals, safety procedures, regulatory
requirements, and industry standards and codes
The operator shall not:
operate the equipment if the direction of travel or function engaged does not agree with what is
indicated on the controller
operate any damaged or malfunctioning equipment
change any settings or controls without authorization and proper training
remove or obscure any warning or safety labels or tags
leave power on the radio controlled equipment when the equipment is not in operation
operate any equipment using a damaged controller because the unit may be unsafe
operate manual motions with other than manual power
operate radio controlled equipment when low battery indicator is on
Flex Pro Transmitter Instruction Manual
April 2019
Page 11 of 25
2.5 Transmitter Unit
Transmitter switches should never be mechanically blocked on or off. When the unit is not in use, the
operator should turn the transmitter off. A secure storage space should be provided for the transmitter unit,
and the transmitter unit should always be placed there when not in use. This precaution will help prevent
unauthorized people from operating the material handling equipment.
Spare transmitters should be stored in a secure storage space and only removed from the storage space
after the current transmitter in use has been turned off, taken out of the service area and secured.
2.6 Pre-Operation Test
At the start of each work shift, or when a new operator takes control of the equipment, operators
should do, as a minimum, the following steps before making lifts with any equipment:
Test all warning devices.
Test all functions.
Test the transmitter machine stop.
2.7 Handling Batteries
Use only batteries approved by Magnetek for the specific product.
Do not dispose of a battery pack in fire; it may explode.
Do not attempt to open the battery pack.
Do not short-circuit the battery.
Keep the battery pack environment cool (for example, not in direct sunlight or close to a heating source)
during storage.
WARNING
The operator should not attempt to repair any radio controller. If any product performance or safety
concerns are observed, the equipment should immediately be taken out of service and be reported to
the supervisor. Damaged and inoperable radio controller equipment should be returned to Magnetek
for evaluation and repair. Failure to follow this warning could result in serious injury or death and
damage to equipment.
WARNING
Know and follow proper battery handling, charging and disposal procedures. Improper battery
procedures can cause batteries to explode or do other serious damage. Failure to follow this warning
could result in serious injury or death and damage to equipment.
Flex Pro Transmitter Instruction Manual
April 2019
Page 12 of 25
2.8 Optional Rechargeable Battery Charging
For those transmitters equipped with rechargeable batteries and battery chargers, all users shall be
familiar with the instructions of the charger before attempting to use.
Do not attempt to charge non-rechargeable battery packs in the charger.
Avoid charging partially discharged rechargeable batteries to help prolong battery cycle life.
Do not charge batteries in a hazardous environment.
Keep the battery pack environment cool (for example, not in direct sunlight or close to a heating source)
during charging.
Do not short the charger.
Do not attempt to charge a damaged battery.
Use only Magnetek-approved chargers for the appropriate battery pack.
Do not attempt to use a battery that is leaking, swollen or corroded.
Charger units are not intended for outdoor use. Only use charger units indoors.
2.9 Battery Disposal
Before disposing of batteries, consult local and governmental regulatory requirements for proper disposal
procedure.
2.10 Crane/Lifting Device Specific Warnings
WARNING
All equipment must have a mainline contactor installed and all tracked cranes, hoists, lifting devices
and similar equipment must have a brake installed. Failure to follow this warning could result in serious
injury or death and damage to equipment.
An audible and/or visual warning means must be provided on all remote controlled equipment as
required by code, regulation, or industry standard. These audible and/or visual warning devices must
meet all governmental requirements. Failure to follow this warning could result in serious injury or
death and damage to equipment.
The direct outputs of this product are not designed to interface directly to two state safety critical
maintained functions, i.e., magnets, vacuum lifts, pumps, emergency equipment, etc. A mechanically
locking intermediate relay system with separate power considerations must be provided. Failure to
follow this warning could result in serious injury or death or damage to equipment.
Flex Pro Transmitter Instruction Manual
April 2019
Page 13 of 25
Cranes, hoists, lifting devices and other material handling equipment can be large and can operate at high
speeds.
The operator should:
continuously watch and monitor status of lifted loads
know and follow cable and hook inspection procedures
The operator shall not:
lift or move more than the rated load
use the crane, hoist or lifting device to lift, support or transport people
lift or carry any loads over people
operate the crane, hoist or lifting device unless all persons, including the operator, are and remain
clear of the supported load and any potential pinch points
operate a crane, hoist or lifting device when the device is not centered over the load
operate a crane, hoist or lifting device if the chain or wire rope is not seated properly in the
sprockets, drum or sheave
leave any load unattended while lifted
2.11 Specific System Warnings
The following specific operating safety tips should be strictly followed when operating a Flex Pro system:
Check the Status LED on the transmitter for any signs of low battery power (See Section 5.3
Status Lights Indicators and Warnings on page 22).
Check the Status LED on the transmitter for any signs of irregularities (See Section 5.3 Status
Lights Indicators and Warnings on page 22).
Make sure the system is not set to the same channel as any other Flex systems in use within a
distance of 300 meters (900 feet).
Never operate equipment with two transmitter handsets at the same time unless they are
programmed for such use.
Flex Pro Transmitter Instruction Manual
April 2019
Page 14 of 25
3 General System Information
3.1 External Illustration (Pro 12 Configuration)
Fig. 1
NOTE: Push Buttons #9 – #12 are not present on the Flex Pro 8 Module.
E. Emergency STOP Button 9. Pushbutton #9
S. Removable Power Key Switch 10. Pushbutton #10
1. Pushbutton #1 11. Pushbutton #11
2. Pushbutton #2 12. Pushbutton #12
3. Pushbutton #3 SC. Strap Ring
4. Pushbutton #4 SN. System Information
5. Pushbutton #5 RN. System Channel
6. Pushbutton #6 MN. Crane Number
7. Pushbutton #7 FC. FCC Information
8. Pushbutton #8
Flex Pro Transmitter Instruction Manual
April 2019
Page 15 of 25
3.2 Internal Illustration (Pro 12 Configuration)
Fig. 2
NOTE: Flex Pro 8 Module will differ slightly.
1. Encoder Board 5. Function LED Displays
2. Aerial Antenna 6. I-CHIP
3. Transmitting Module 7. Dip-Switch
4. Status LED Display 8. Battery Contact Mechanism
Flex Pro Transmitter Instruction Manual
April 2019
Page 16 of 25
3.3 Types of Buttons
The buttons used on the Flex Pro are fully proportional, stepless push buttons with an output that varies
0 – 100%, based on how far the button is depressed. It is possible to model the stepless buttons as an
ON/OFF momentary switch, an ON/OFF latched switch, a 2-Speed button, or a 3-Speed button. This
modeling is done on the receiver end of the system. Please consult the factory for more information.
3.4 Adjustable Speed Control (if equipped)
The proportional buttons normally operate on a scale from 0-100%, but they can also be scaled down to
operate linearly from 0-75%, 0-50%, or 0-25% over the full motion of the button. This gives the user more
control over lower speeds. To adjust the speed control settings, press and hold the START button and then
press push button 1 or push button 2 to decrement or increment the range percentage. The red LEDs,
which indicate the Speed Setting, will then change to reflect the current setting.
Start + Speed Control Setting
PB1 Decrement Speed Control
PB2 Increment Speed Control
Fig. 3
Fig. 4
Flex Pro Transmitter Instruction Manual
April 2019
Page 17 of 25
4 Function Settings
4.1 System Channel Settings
Set the transmitter channel by adjusting the channel dip-switch located on the backside of the transmitter
encoder board (refer to Fig. 5). Only the first 5 positions of the dip-switch are used for channel
programming (refer to Fig. 6). The system channels table (Table 1 on page 18) describes which dip-switch
setting corresponds to which channel. Once the transmitter channel has been altered, set up the receiver
to recognize the transmitters on its new channel.
The dip-switch setting “1 0 0 1 0” shown in Fig. 6 corresponds to channel 19 in the system channels table
(Table 1 on page 18).
Fig. 5
Fig. 6
Flex Pro Transmitter Instruction Manual
April 2019
Page 18 of 25
Table 1: System Channel Table
NOTE: Frequencies marked with * are approved for use in Australia.
NOTE: Frequencies marked with ^ are approved for use in Singapore.
Channel Frequency
Dip-switch
Setting
Channel Frequency
Dip-switch
Setting
01 433.000 MHZ 00000 17*^ 433.800 MHZ 10000
02*^ 433.050 MHZ 00001 18*^ 433.850 MHZ 10001
03*^ 433.100 MHZ 00010 19*^ 433.900 MHZ 10010
04*^ 433.150 MHZ 00011 20*^ 433.950 MHZ 10011
05*^ 433.200 MHZ 00100 21*^ 434.000 MHZ 10100
06*^ 433.250 MHZ 00101 22*^ 434.050 MHZ 10101
07*^ 433.300 MHZ 00110 23*^ 434.100 MHZ 10110
08*^ 433.350 MHZ 00111 24*^ 434.150 MHZ 10111
09*^ 433.400 MHZ 01000 25*^ 434.200 MHZ 11000
10*^ 433.450 MHZ 01001 26*^ 434.250 MHZ 11001
11*^ 433.500 MHZ 01010 27*^ 434.300 MHZ 11010
12*^ 433.550 MHZ 01011 28*^ 434.350 MHZ 11011
13*^ 433.600 MHZ 01100 29*^ 434.400 MHZ 11100
14*^ 433.650 MHZ 01101 30*^ 434.450 MHZ 11101
15*^ 433.700 MHZ 01110 31* 434.500 MHZ 11110
16*^ 433.750 MHZ 01111 32* 434.550 MHZ 11111
Flex Pro Transmitter Instruction Manual
April 2019
Page 19 of 25
4.2 Inactivity Time-Out Timer
Bits 6 and 7 on the dip-switch allow the user to define a time after which, if no buttons on the transmitter
are pressed, the Flex Pro will send an OFF command to the receiver and power down. To restart the unit,
the user must turn the ON/OFF/START switch to the OFF position and then back to ON again to resume
operation.
4.3 I-CHIP
The I-CHIP functions in a way that is very similar to a SIM card inside a mobile phone, which stores system
information such as your telephone number, account number, phone book and other settings. The I-CHIP
works exactly the same way, as it stores information such as system access code and CAN source
address.
When replacing a transmitter handset, take the I-CHIP out of the old transmitter and install it into the new
one (refer to Fig. 8).
For safety purposes, the system access code stored inside the I-CHIP cannot be changed directly on the
transmitter encoder board. You can change transmitter access code via an external I-CHIP programmer or
duplicator unit available from the factory. Please ask your local dealer for assistance if your system
requires access code adjustments.
Fig. 8
Time Out Dip-switch Setting
Fig. 7
5 minutes 01
10 minutes 10
15 minutes 11
Never shut off 00
WARNING
When opening and closing the unit, take special care to ensure the arms of the microswitch for the
OFF/ON/START switch are not damaged when the printed circuit board is put back into the top
housing. Ensure that the OFF/ON/START switch is in the OFF position before putting the board in the
top housing.
Flex Pro Transmitter Instruction Manual
April 2019
Page 20 of 25
5 Operating Procedure
5.1 General Operating Procedure
1. Reset the red emergency stop button located on the top left hand side of the transmitter
handset by turning it either clockwise or counterclockwise. The red button will pop up.
Fig. 9
2. Turn on the transmitter power by inserting the black-colored key into the power key slot
located on the top right hand side of the transmitter handset, and turn it clockwise to the
ON position.
3. After turning on the transmitter power, check the Status LED on the transmitter handset for
any sign of system irregularities (See Section 5.3 Status Lights Indicators and
Warnings on page 22). If the system is normal, the Status LED will light up green for
2 seconds and then slowly flash green.
4. If there are no signs of any system irregularities, turn the power key further clockwise to
the START position for up to 2 seconds. This will activate the receiver E-Stop. Thereafter,
the same START position will become an auxiliary function with momentary contact.
Fig. 12
Fig. 10
Fig. 11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25

Magnetek Flex 8 PRO User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI