Front Key:
OPERATING MANUAL
LC - 3006
A) Display : 6 Digit display in RED colour indicating current reading of TOTAL METER
During Running mode and MTRS/MIN when shift key is pressed.
These front keys can be used to see and change the current value of
A) Total Meters SET Point (SET) : Set point value is automatically compared with current
Value of Total Meters. A relay is switched ON when set value and total meter are equal. This
Relay output can be used to start or stop machine.
Maximum Range : 99999.9
B) Diameter OF Roller (D): It is the diameter of roller over which the material (thread)
Passesd. MAXIMUM RANGE : 999.99 mm
C) Auto Reset Time (T): It is the auto reset time of relay remains in ON condition.
MAXIMUM RANGE : 99.9 Seconds.
B) LED’S : Three Red LED indicates following status when it glows :
Relay-1 : Relay Operates when total meters are reached.
L : Gives only indication when the total length in meter is seen during running Mode.
S : Gives only indication when the speed in MTRS/MIN is seen during running mode by
Pressing shift key.
44 X 92 mm
230V AC,50Hz,Approx 4VA
Model
Panel Cutout
Dimension
Display
Output
Input
Operating Ambient
Temperature
Supply
Reset
Relative Humidity
48 X 96 X 120 mm
Single Display: 6 digit, 0.4’’,
1 Relay 1C/O, 230V AC, 5A
7 segment, Red LED
LC - 3006
NPN/PNP Proximity Switch
0°C - 55°C
Reset at back terminal
Up to 95 % RH Non Condensing
SET
ENT RESET
LC-3006
LC 3006
9 9 9 9 9. 9
Technical Specification
Displays
Page - 2 www.multispanindia.com
PROCEDURE TO ENTER/CHANGE SET POINT 1:
PROCEDURE TO ENTER/CHANGE DIAMETER OF ROLLER:
PROCEDURE TO ENTER/CHANGE AUTO RESET TIME
PROCEDURE TO SPEED SELECTION
TOTAL METERS = x D x No. of revolution of the Roller.
TOTAL METERS/MINUTE = x D x Roller speed in RPM.
Press key for 2 seconds.
Whenever this instrument is used first time the diameter value of machine roller is to be entered
for that application. From that Diameter the instrument calulates the total length passing over
the roller as explaned below.
Press key for 5 seconds.
Press key for 7 seconds.
Press key for 9 seconds.
Here maximum limit is 99999.9 meter.
Here maximum limit is 999.99 mm
Here maximum limit is 99.9 seconds.
You can change by key to speed selection.
Change current value of set point by following PROCEDURE (4).;
Change current value of set point by following PROCEDURE (4).
Change current value of set point by following PROCEDURE (4).
Display will show SETmtr 1.
Display will show DIAMTR
Display will show tIME
Display will show MEDIUM
Operation:
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
SET
SET
SET
SET
ENT
ENT
ENT
ENT
SET
ENT
PROCEDURE :
The 6 digit setting is done with the help of two keys.
Shift key selects the digit to be modified.
A blinking dot indicates the selected digit.
UP key is used to set the selected digit.
If any key is not pressed for 5 seconds, the previous value of set point is retained and counter goes
in to control mode.
Press key to store set value in memory, Simultaneously count goes in control mode
Shift the dot to a digit you want to change, by key.
Increase the value of selected digit by key.
Shift key and UP Key
*
*
*
*
*
*
*
*
*
D) Speed Selection: (Medium/Slow/Fast) (Speed Selection by key)
E) Decimal Point: 9999.99,99999.9,999999 (DP change by key)
1. Do all connection as shown in connection diagram and turn on the instrument.
2. Set all parameter as per requirement.
3. Display will indicates current reading of TOTAL METERS.
4. When display count equal set count Relay is operated and red led will be ON.
5. Now, Relay remains in ON condition for auto reset time. After completion of auto reset time
Relay turns off.
6. f you set TIME = 00.0 second then it will be in MANUAL MODE and if you set Time = 00.1 To 99.9I
seconds, then it will be in AUTO RESET MODE.
7. If you set the Auto reset Time to 00.0 seconds, then Relay remains in ON condition until Reset key
is Pressed.
8. Press Shift key to see speed in MT/MIN. At this time ‘S’ LED will glow.
9. Press Shift key another time to return into Length mode. In length mode ‘L’ LED will glow.
10. Pressing RESET key display shows set value.
11. If power goes OFF while counting, the TOTAL METER reading at the time of power failure is
stored in non-volatile memory and the counter starts counting from stored value when power
turns ON.
Page - 3 www.multispanindia.com
RESET
NPN PNP
I/P I/P GND
+12V
MICRO SWITCH :- M/S Connection 10 & 12
Sensor : PROXY NPN / PNP
1
9
2
10 11
3 4
12 13 14
5678
NC
RELAY
CNO
LN
230V AC
50Hz, 4VA
Made in India
www.multispanindia.com
!
Connection Diagram
Working
Product improvement and upgrade is a constant procedure. So for more updated operating information and support,
please contact our Helpline : +91-9978991474/76/82 or Email at Ver :-2001ser[email protected]
Page - 4 www.multispanindia.com
All safety related codifications, symbols and instructions that appear in this operating manual
or on the equipment must be strictly followed to ensure the safety of the operating personnel as
well as the instrument.
If all the equipment is not handled in a manner specified by the manufacturer, it might impair the
protection provided by the equipment .
=> Read complete instructions prior to installation and operation of the unit.
WARNING : Risk of electric shock.
3) Cable used for connection to power source, must have a cross section of 1mm or greater. These wires
should have insulations capacity made of at least 1.5kV.
2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of equal size shall
be made with shortest connection.
1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is being supplied.
4) A better anti-noise effect can be expected by using standard power supply cable for the instrument.
1) This equipment, being built-in-type, normally becomes a part of main control panel and such in case the
terminals do not remain accessible to the end user after installation and internal wiring.
2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product
or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
3) Circuit breaker or mains switch must be installed between power source and supply terminal to
facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be
installed at convenient place normally accessible to the operator.
4) Use and store the instrument within the specified ambient temperature and humidity ranges as
mentioned in this manual.
Maintenance
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.
1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent.
3) Fusible resistor must not be replaced by operator.
2
B
AC
D
60mm - 2.36 inches
F
E
MODEL A
48mm 96mm 44mm 92mm 4.5mm 66mm
BC
D E
F
DIMENSIONS
Warning Guidelines
Safety Precautions
Installation Guidelines
Mechanical Installation
LC 3006
9 9 9 9 9. 9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4