Ortech ODDMF-6-350-Q ODDMF Silencers ODDMF Inline Fans are suitable for residential, commercial, and industrial ventilation, and even hydroponic ventilation (exhaust and intake). They are powered by an EC motor, feature high static air pressure, aerodynamically-optimized airflow, quiet operation, and extremely high efficiency. Multiple Speed Control Signals are available (Potentiometer; PWM; 0-10V, Tachometer). It is recommended to use a pre-filter on the absorption axis to prevent dust, oil, and other foreign substances from building up on the impeller.

Ortech ODDMF-6-350-Q ODDMF Silencers ODDMF Inline Fans are suitable for residential, commercial, and industrial ventilation, and even hydroponic ventilation (exhaust and intake). They are powered by an EC motor, feature high static air pressure, aerodynamically-optimized airflow, quiet operation, and extremely high efficiency. Multiple Speed Control Signals are available (Potentiometer; PWM; 0-10V, Tachometer). It is recommended to use a pre-filter on the absorption axis to prevent dust, oil, and other foreign substances from building up on the impeller.

WARNING
ODDMF Silencers
MODEL ODDMF-6-350-Q | ODDMF-8-710-Q | ODDMF-10-1065-Q | ODDMF-12-1750-Q
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
Electrical products can cause death or injury, or damage to property.
If in any doubt about the installation or use of this product, consult a competent technician.
CLEANING & MAINTENANCE
WARNING — THE INSTALLATION MUST BE CARRIED OUT BY A QUALIFIED TECHNICIAN.
1. DO NOT open. No user serviceable parts inside
2. ODDMF Silencers are intended for indoor use only
3. Install with duct on inlet and duct and/or fan silencer on exhaust of fan
4. Speed control MUST be connected for the ODDMF Silencers to function
5. Ensure the product is unplugged from the electrical outlet before relocating, servicing or cleaning
Instruction Manual
1-888-543-6473
1-888-541-6474
13376 Comber Way
Surrey BC V3W 5V9
www.ortechindustries.com
375 Admiral Blvd
Mississauga, ON L5T 2N1
APPLICATION NOTICE
For general ventilation use only
Install guard screens if personnel have
access to inlet or exhaust of fan
DO NOT use to exhaust hazardous
explosive materials and vapours
Ensure that the fan is switched off
from the supply mains before
removing guard
Precautions must be taken to avoid the
back-flow of gases, in this case, a check
valve is necessary
To disconnect, first turn the unit off,
grip the plug and pull from the wall
outlet. NEVER pull the plug by the cord
CAUTICAUTION
Wipe the unit and blades with a damp cloth
DO NOT spray water or liquid on or into the fan
DO NOT clean the units with cloths that have metal parts
Clean the unit regularly to ensure the blades can move freely
CAUTION
DO NOT pull the cord too hard as it
could damage and fray. If the supply
cord is damaged, it must be replaced
by the manufacturer, its service agent
or similarly qualified persons in order
to avoid an electrical hazard
DO NOT allow the power cord or any
other parts of the fan to touch hot
surfaces, open flames, cooking or other
heating appliances and DO NOT place
near hot gas or electric burners
Turn the unit off when moving to
another location and before cleaning
DO NOT operate if housing is damaged
CAUTICAUTION
Ensure all the packaging has been
removed and that the voltage used
corresponds to the voltage indicated
on the rating plate
DO NOT cover any openings on the
fan or insert objects or parts of the
body into any of its openings when
fan is on or off
To protect against electric shock, do
not immerse unit, plug or rcord in
water or other liquids
Keep cord away from areas where it
could be walked on or tripped over
CAUTICAUTION
DO NOT use this fan in the following circumstances:
Environment with significant dust
Environmental humidity is above 90%
Operating Temperature is less than -10ºC, or above +60ºC
Places wherre children or pets have easy access to the fan blades
Flammable or hazardous atmosphere, near explosive gases, or chemical dust
TICAUTION
DO NOT use cleaning detergent or chemicals to clean the fan
NEVER immerse in water or let water enter the fan controller outlet
DO NOT clean while the unit switch is on. Turn off and unplug the unit
FEATURES
This EC Mix Flow Silencer is powered by cutting-edge EC motor featuring high static air pressure, aerodynamically-optimized airflow, quiet
operation, and extremely high efficiency. They are ideal for residential, commercial and industrial ventilation, and even hydroponic ventilation
(exhaust and intake). Multiple Speed Control Signals available (Potentionmeter ; PWM; 0-10V , Tachometer)*
Instruction Manual
1-888-543-6473
1-888-541-6474
13376 Comber Way
Surrey BC V3W 5V9
www.ortechindustries.com
375 Admiral Blvd
Mississauga, ON L5T 2N1
OPERATION
WARNING!
MUST CONNECT SECURELY TO SPEED CONTROL BEFORE POWER UP
DO NOT deform fan bracket or fan housing
DO NOT install fan on sheet rock or weak surface
Always install the fan at the height of 2.1m or above
Unpack and check fan for damage. Ensure that the fan impeller
spins freely and not touching fan housing.
Use a pre-filter on the absorption axis to prevent dust, oil and
other foreign substances from building up on the impeller.
Build up of dust and or foreign material can cause out of balance
impeller and excessive vibration.
Excessive vibration will reduce fan lifetime.
INSTALLATION GUIDE
Use the appropriate attachment screws for the surface material
being selected to mount the fan.
Use the supplied mounting bracket or hanger.
After completing the installation, electrical work and duct work,
perform the test operation to confirm if the fan operates normally
After turning the power on, the fan should rotate freely,
and build up speed normally
If there is abnormal noise or no rotation,
check all connections as well as power supply
Wall Mounted Installation
Mark the screw position
on the wall
Punch holes in the wall Screw the fan onto the wall
Connect the ducts onto
two sides with clamps
Connect the speed control to the
fan and make sure the connection
is in place and fastened
Power up the fan
Hang Installation
123
456
ODDMF Silencers
MODEL ODDMF-6-350-Q | ODDMF-8-710-Q | ODDMF-10-1065-Q | ODDMF-12-1750-Q
INSTALLATION GUIDE
Instruction Manual
1-888-543-6473
1-888-541-6474
13376 Comber Way
Surrey BC V3W 5V9
www.ortechindustries.com
375 Admiral Blvd
Mississauga, ON L5T 2N1
PRODUCT CONTENT DIAGRAM
Intake and Exhaust
This fan can be used as either an intake fan or exhaust fan in grow
rooms or tents to achieve optimal whole space ventilation.
Used as the intake fan or opening:
If it is NOT used as a fan, it must be situated at a bottom
corner of your grow space
Used as the exhaust fan:
It must be hung (see the right side diagram) or
mounted at the highest opposite corner
Inlet Ducting
Speed control
interface
Exhaust Ducting
Power Cord
Bracket
FAN CONTROLS
Standard ControlAll EC fans go with a portable variable
speed controller or wall mounted controller
Portable Speed
Controller
Simple & portable
0-100% variable
speed controller by
potentiometer
Wall Mounted
Controller
Fits into the in-wall
installation of
Provides 0-100%
variable speed
control range
ODDMF Inline
Series Silencers
offer a standard
variable speed
controller via
potentionmeter
It can also offer
multiple way to
control the fan
speed, supporting
varies HVACR
system and
compatible with
other controllers by
PWM & 0-10V
ODDMF Silencers
MODEL ODDMF-6-350-Q | ODDMF-8-710-Q | ODDMF-10-1065-Q | ODDMF-12-1750-Q
FAN CONTROLS
Instruction Manual
1-888-543-6473
1-888-541-6474
13376 Comber Way
Surrey BC V3W 5V9
www.ortechindustries.com
375 Admiral Blvd
Mississauga, ON L5T 2N1
DIY 4-Pins Control
EC fan with multi speed control signals is
packed with DIY 4 pins connection cable.
OPTIONAL CONTROLS & ACCESSORY
EC fan with multiple speed control signals offers great flexibility and compatibility of speed control with various accessory:
Smart control, remote control, wall mounted variable control, controller adapters and extension cable.
Smart Controller with Probe
(sold separately)
6 speed controller with thermal probe for
monitoring environmental temperature,
accurate ventilation and energy saving,
supporting control of up to 4 EC fans
simultaneously and mode selection of
manual, auto and alert.
Wireless Remote with Receiver
(sold separately)
Allows you to control your EC fan wirelessly.
6 preset speed levels (15-100% output).
50ft / 15m signal range, which works
through walls, floors and ceilings. Ideal for
fans installed in hard to reach places.
Adapter to Other 3 Pins Controller
(sold separately)
This adapter has a male 3.5MM TRRS Jack
and female 3PINS connector it gives
additional support for using SigilVentus
EC fan controller in the market, e.g. GAS
type No.150 Digital EC fan controller,
GAS type No.501 Digital EC 5 controller
Adapter to Other RJ45 Controllers
(sold separately)
This adapter is with 3.5MM TRRS male
jack and RJ45 female connector it gives
additional support for using SigilVentus
EC fan controller in the market, e.g.
PRIMA KLIMA ECTC-1M display controller
3.5MM TRRS Jack Extension Control Cable
(sold separately)
5 meters long extension cable for flexible
controller installation in a long distance
within 10 meters.
Full Speed Plug
(sold separately)
This plug is useful when no speed control
is required. The fan will work at MAX.
SPEED once plugged.
ORTECH reserves the right to modify at any time, without notice, any or all of our product's
features, designs, components and specifications to meet market changes.
ODDMF Silencers
MODEL ODDMF-6-350-Q | ODDMF-8-710-Q | ODDMF-10-1065-Q | ODDMF-12-1750-Q
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Ortech ODDMF-6-350-Q User manual

Type
User manual
This manual is also suitable for

Ortech ODDMF-6-350-Q ODDMF Silencers ODDMF Inline Fans are suitable for residential, commercial, and industrial ventilation, and even hydroponic ventilation (exhaust and intake). They are powered by an EC motor, feature high static air pressure, aerodynamically-optimized airflow, quiet operation, and extremely high efficiency. Multiple Speed Control Signals are available (Potentiometer; PWM; 0-10V, Tachometer). It is recommended to use a pre-filter on the absorption axis to prevent dust, oil, and other foreign substances from building up on the impeller.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI