Danfoss HC6000 Series Installation guide

Category
Thermostats
Type
Installation guide
TP7000 + RF
GB
Installation Instructions
User Instructions
Instructions d’installation
Instructions d’utilisateur
Installationsanweisungen
Inbetriebnahme-Instruktion
Instrucciones de instalación
Instrucciones del usuario
Instruktions vejledning
Brugervejleding
Electronic 7 day programmable room thermostat
Installatie handleiding
Instructies voor Gebruik
Ïäçãßåò åãêáôÜóôáóçò
Ïäçãßåò ÷ñÞóçò
Instrukcja instalacji
Instrukcja Użytkownika
Montavimo instrukcijos
Informacija Vartotojui
Istruzioni per l’uso
Istruzioni per l’utente
F
D
ES
DK
NL
GR
PL
LT
I
®
Certification Mark
2
INDEX
Installation Instructions 3-6
User Instructions 7-13
Instructions d’installation 14-17
Instructions d’utilisateur 18-23
Installationsanweisungen 24-27
Inbetriebnahme-Instruktion 28-33
Instrucciones de instalación 34-37
Instrucciones del usuario 38-43
Instruktions vejledning 44-47
Brugervejleding 48-53
Installatie handleiding 54-57
Instructies voor Gebruik 58-63
Ïäçãßåò åãêáôÜóôáóçò 64-67
Ïäçãßåò ÷ñÞóçò 68-73
Instrukcja instalacji 74-77
Instrukcja Użytkownika 78-83
Montavimo instrukcijos 84-87
Informacija Vartotojui 88-93
Instruzioni per l’uso 94-97
Instruzioni per l’utente 98-103
GB
F
D
ES
DK
NL
GR
PL
LT
I
3
Thermostat Features TP7000-RF
TP7000
TP7000A
TP7000-M
TP7000-MA
TP7000-M 24
Power supply
2 x AA/MN1500/LR6
alkaline batteries
230v, 50 Hz 24v, 50 Hz
Memory backup
Capacitor during
battery change for 1
minute
Rechargable cell, 24 hrs (*1)
Switching action of output relay N/A 1 x SPDT, Type 1B
Switch rating of relay contact,
voltage and current
N/A 3(1) A, 10-230 volts
Transmitter frequency (RF only) 433.92 MHz N/A
Transmitter range (RF only) 30m max. N/A
Rated Impulse Voltage N/A 2.5Kv
Dimensions (mm) 138 wide x 88 high x 28 deep
Ball Pressure Test 75°C
Temperature Range 5-30°C
Design Standard EN 60730-2-7 (EN300220 for RF)
Control Pollution Situation Degree 2
Time accuracy ± 1 min.
Temperature accuracy ±1°C
*1: Unit must powered up for 6 days to charge cell before full back-up is available
Installation Instructions
Important note RF products: Ensure that there are no large metal objects,
such as boiler cases or other large appliances, in line of sight between the
transmitter and receiver as these will prevent communication between
thermostat and receiver.
Speci cation
Installation Instructions
Please Note:
This product should only be installed by a quali ed electrician
or competent heating installer and should be in accordance with
the current edition of the IEEE wiring regulations.
GB
4
All models
Sw
1
5/2 day programming 7 day programming
Sw
2
Optimum start contoller enabled Optimum start contoller disabled
Sw
3
Chrono-proportional control On/O control
TP7000, M, & RF models with 3/6 cycles per hour option
Sw
4
Chrono-proportional, 6 cycles / hour Chrono-proportional, 3 cycles / hour
Installation
DIL Switch Settings
First remove the wallplate from the back of the unit.
From the top left hand corner of the wallplate, there must be
clearances of at least 140mm to the right, 15mm to the left, 30mm
above and 100mm below in order to mount the plug-in module.
Before mounting the unit ensure the 4 DIL switches on the rear of the
unit have been moved to the required settings (see below). Factory
preset is 7-day, with Optimum Start and Chrono-proportional
control OFF.
NOTE
Use Chrono 3 for high thermal inertia systems, e.g.  oor standing cast iron boilers.
Use Chrono 6 for low thermal inertia systems, e.g. low water content boilers and combi
boilers.
Installation Instructions
GB
5
TP7000 Wiring (not RF models)
7-day - each day can be programmed with di erent times and
temperatures.
5/2 day - one set of times & temperatures for weekdays, and another
set for weekends.
Optimum start control - function which switches the heating on
earlier than the Event 1 programmed time to ensure the required
temperature is achieved by the set time.
Chrono-proportional control - energy saving feature which  res the
boiler at regular intervals to maintain a set temperature, achieving a
constant ambient environment for the user.
Setting Optimum Start Control
-4˚C
-3˚C
-2˚C
-1˚C
A
B
C
120
min.
90
min.
60
min.
30
min.
Event
time
(
D
Set Sw2 to OSC ON
(see DIL settings page 4)
Select OPTIMISER CURVE in
programming mode
A Event 1 Set Point
B Deviation from Set Point
C Switch On Time prior to Event
D Optimiser Curve Setting
1
234567
ELECTRONICS
REMOTE
SENSOR
'A' models
only
COM
ON
OFF
Installation Instructions
GB
B
C
M 24V models onl
y
24V
L
N
M 230V models onl
230V
Note: 1.0mm
2
solid copper cable should be used to connect the remote
sensor to the TP7000A. Please ensure that:
a) the cable length does not exceed 50 metres,
b) to avoid electrical interference the cable should not be run parallel
in close proximity to other cables carrying mains electricity, and where
necessary the cable should cross over mains cabling at right angles.
6
1. TP7000-RF
Press the recessed RESET button, using a non-
metallic object, to reset the unit.
2. Press & hold the recessed LEARN button for 3
seconds, using a non-metallic object.
NOTE: Thermostat now transmits continuously for 5 mins.
3. RX1 - Press and hold buttons PROG and CH1 for
3 seconds until green light  ashes once.
4. RX2 (if applicable)
Stat 1 - perform steps 1-3.
Stat 2 - wait 5 mins, perform steps1-2 and then press PROG and CH2
on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1 – 3.
Stat 2 - wait 5 mins, perform steps 1-2 and then press PROG and CH2
on RX3.
Stat 3 - wait 5 mins, perform steps 1-2 and then press PROG and CH3
on RX3.
5. TP7000-RF - Press or to return the unit to
normal operation.
Commissioning (RF versions only)
If the thermostat and the receiver have been supplied together in
a combined pack, the units have been paired in the factory and no
commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal, follow
steps 1-5 below.
RX1
LEARN
RESET
Receiver Wiring (RF models only)
12
3
4
ELECTRONICS
N
L
COM
ZONE
1 ON
ZONE
1 OFF
A
ELECTRONICS
B
C1
2
345
6
N
L
ZONE
1 ON
ZONE
1 OFF
ZONE
2 ON
ZONE
3 ON
COM
TERMINAL 6
RX3 ONLY
RX1 RX2 & RX3
Note: 1) For mains voltage operated systems link terminal 2 to mains live supply.
2) Power supply to unit must not be switched by timeswitch.
Installation Instructions
GB
7
What is a programmable room thermostat?
... an explanation for householders
A programmable room thermostat is both a programmer and a room
thermostat. A programmer allows you to set ‘On and ‘O time periods
to suit your own lifestyle. A room thermostat works by sensing the air
temperature, switching on the heating when the air temperature falls below
the thermostat setting, and switching it o once this set temperature has
been reached.
So, a programmable room thermostat lets you choose what times you want
the heating to be on, and what temperature it should reach while it is on.
It will allow you to select di erent temperatures in your home at di erent
times of the day (and days of the week) to meet your particular needs.
Turning a programmable room thermostat to a higher setting will not make
the room heat up any faster. How quickly the room heats up depends on the
design of the heating system, for example, the size of boiler and radiators.
Neither does the setting a ect how quickly the room cools down. Turning
a programmable room thermostat to a lower setting will result in the room
being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to  nd the
lowest temperature settings that you are comfortable with at the di erent
times you have chosen, and then leave it alone to do its job. The best way to
do this is to set low temperatures  rst, say 18°C, and then turn them up by
one degree each day until you are comfortable with the temperatures. You
won’t have to adjust the thermostat further. Any adjustments above these
settings will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one
programmable room thermostat to control the whole house. But you can
have di erent temperatures in individual rooms by installing thermostatic
radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you
should choose a temperature that is reasonable for the whole house. If you
do have TRVs, you can choose a slightly higher setting to make sure that
even the coldest room is comfortable, then prevent any overheating in other
rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types have to be
adjusted in spring and autumn at the changes between Greenwich Mean
Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for example,
‘Override, Advance or ‘Boost. These are explained in the manufacturers
instructions.
Programmable room thermostats need a free  ow of air to sense the
temperature, so they must not be covered by curtains or blocked by
furniture. Nearby electric  res, televisions, wall or table lamps may prevent
the thermostat from working properly.
User Instructions
GB
8
User Instructions
Your programmable room thermostat
The TP7000 allows you to programme up to 6 di erent time and
temperature settings for each day of the week, providing complete
exibility. It provides several energy saving features and features
several useful user overrides, including a 99 day holiday mode.
Preset Programmes
Your TP7000 comes ready programmed with a set of operating times and
temperatures which often suit most people.
If you want, you can change any of these settings by following the
instructions on pages 10-11. First follow the steps on page 9 to set your
display preferences and the correct time and date.
Before you start
Open the  ap on the front of your
programmer. Using a non-metallic
object, press the recessed RESET
button, until you hear a click and the
display goes blank.
Weekdays (Mon-Fri) Weekend (Sat-Sun)
Event Time Temp °C Event Time Temp °C
1 06:30 20 1 07:30 20
2 08:30 15 2 09:30 20
3 11:30 20 3 11:30 20
4 13:30 15 4 13:30 20
5 16:30 21 5 16:30 21
6 22:30 15 6 22:30 15
RESET
User Instructions
GB
9
Display preferences
Temperature display (°C or °F)
Press and hold DAY & COPY (for 2-3 seconds)
until display changes.
Clock display (12 or 24 hr)
Press and hold NEXT & DAY (for 2-3 seconds)
until display change.
(AM or PM will appear in 12 hr mode)
Setting the Clock & Day
Press PROG to begin programming.
DAY - Press DAY until correct day is shown
(1=Monday, 2=Tuesday etc).
TIME - Press + and - to change time (press and
hold to change in 10 min increments).
This display will ONLY appear if the OSC function has
been enabled by your installer.
Use the + or - buttons to select the OSC
period. The choices are 0:30 (30 mins), 1:00 (1
hr), 1:30 and 2:00.
The recommended setting is 0:30. If set to
0:00 the function is disabled.
To change DAY
To change TIME
Setting the OSC Period, if enabled (see pg.5)
Accepting the preset programmes
If you are happy to use the preset programmes on page 8, you don’t
need to do anything else. To accept these settings just close the
front cover and after 2 minutes the pre-settings will automatically be
accepted.
User Instructions
GB
10
The unit is now in RUN mode (colon  ashes in
display) and the heating will operate according
to the preset programmes.
a) Press PROG until Event 1  ashes, then press
DAY to move from current day to Day 1.
b) Amend the time and temperature as
follows:
i) Use + and – buttons to alter time
(press and hold to change in 10 min
increments).
ii) Use and buttons to alter
temperature in 0.5°C (1°F) steps.
iii) Press NEXT to advance to next Event.
iv) Repeat steps i,ii & iii above for Events 2,
3, 4, 5 & 6.
Programming in 7-day mode
(separate programmes for each day of the week)
1
Before you change the preset programmes
Your installer will have set your unit to operate in either 7-day mode
or 5/2 day mode. To tell which mode your unit is set press PROG until
Event 1  ashes in the display.
This unit is in 7-day mode and you can programme
di erent settings for each day of the week (see page 10-
11).
This unit is in 5/2 day mode and you can enter one of
set of programmes for weekdays and another set for
weekends (see page 11).
1
1 2 3 4 5
User Instructions
GB
11
c) When all 6 events are correct, press
DAY to programme events for Day 2.
(If you wish to repeat the previous
days programme, simply press
COPY).
d) Repeat steps b & c above to
programme (or COPY) events for Days
3, 4, 5, 6 & 7.
Returning to RUN Mode – press PROG
until colon  ashes in display.
Press PROG until Event 1  ashes, then
press DAY until display shows Day 1-
5.
Follow steps b & c on page 10-11 to
programme times & temperatures for
weekdays.
Press DAY to programme events for
weekend (Day 6-7) or press COPY to
repeat weekday programme.
Returning to RUN Mode – press PROG
until colon  ashes in display.
Programming in 5/2 day mode
(one set of programmes for weekdays, another set for weekends)
1 2 3 4 5
User Instructions
GB
12
To convert to Thermostat mode
Press & hold and together until
display changes to colon blinking &
default temperature (8°C).
Press or to alter temperature as
required.
(If not already in Thermostat Mode, press
& hold and together until display
changes to colon blinking & 8°C).
Press DAY (display will show a suitcase
and :00).
Press + and - to enter number of days of
holiday (max.99).
Use and buttons to alter the constant
temperature, if required.
When selected number of days have elapsed,
the unit will return to normal, controlling
according to your set programmes.
NOTE: Press and buttons together
to exit holiday mode if necessary.
To programme Holiday Mode
(whilst in Thermostat Mode)
The TP7000 can be converted to control at a constant user selected
temperature, instead of following the set programme.
!
NOTE: unit will remain in thermostat mode until the and
buttons are pressed together again.
The TP7000 can control at a constant low temperature while you are away on
holiday, returning to your programmed settings after a speci ed number of
days (maximum 99 days).
User Instructions
GB
13
User Overrides
To temporarily increase or decrease the
programmed temperature.
press or to select the desired
temperature.
Extend Event 1 (i.e. 06.30 20°C) to last all
day (so that heating remains on at a
constant temperature all day).
– press button once as shown.
To extend the current set temperature by
1, 2 or 3 hours.
– press button once for 1 extra hour,
twice for 2 extra hours, 3 times for 3
extra hours, and press 4 times to remove
override.
To alter main LCD display to show either
time or actual room temperature.
press NEXT & COPY together.
Batteries will last in excess of two years.
Low battery indicator will  ash on the LCD
display. The user has 15 days in which to
replace the batteries with high quality
alkaline cells.
Changing Batteries (not TP7000M)
2
Sometimes you may need to change the way you use your heating
temporarily, i.e. due to unusually cold or warm weather. The TP7000 has
several user overrides, which can be selected without a ecting the set
programmes.
User Instructions
GB
104
Part No: 37038v02s1-24 10/07
www.danfoss.com/BusinessAreas/Heating
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

Danfoss HC6000 Series Installation guide

Category
Thermostats
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI