Somecountriesrequiretheuseofassignedratherthannominalprotectionfactors.InformationonassignedcanbefoundinEN529“Respiratory
protectivedevices.Recommendationsforselection,use,careandmaintenance.Guidancedocument”orinyourlocalregulations.
Thesystemisonlyrecommendedforuseinthetemperaturerange-5ºto+55ºCandinconditionswhererelativehumiditydoesnotexceed90%
(<90%RH).
Warning!
• IftheseinstructionsarenotfollowedortheunitisusedincorrectlythesystemmaynotofferprotectiontoEN12941.
• InapoweroffsituationtheheadpieceoffersnorespiratoryprotectionandrapidCO2build-upandoxygendepletionmayalsoresult.
Thisisanabnormalsituation.
• Thetoftheheadpieceshouldbecheckedbeforeuse.Refertothespecicinstructionssuppliedwiththeheadgearfortting&
maintenance instructions.
• Athighworkratesthepressureinsidetheheadpiecemaybecomenegativeatpeakinhalation.
• Thesystemshouldnotbeusedinoxygendecientorenrichedatmospheres.
• Thesystemshouldnotbeusedinareaswherethereisanimmediatedangertohealthorlife(IDLH)
• Theusermustensurethatthenatureofthehazardisidentiedandthatthesystemoffersanadequatelevelofprotection.
• Thisunitshouldnotbeusedwherethenatureofthehazardisunknown.
• ThisunitisNOTintrinsicallysafeandthereforeshouldnotbeusedinexplosiveatmospheres.
• Assembly,maintenanceandttingmustbedoneinacleanairarea.
• Beawarethatthehoseprotrudesfromthebackoftheheadpieceandtakecaretoavoidsnagging.
• Inhighwindvelocitiestheassumedprotectionlevelsmaynotbeachieved.
• Athigheraltitudesabove500metrestheBlockedlteralarmmaysoundprematurely(contactESABforfurtherinformation).
• Usedwiththatlter.TheclassicationforEN12941willbeginwith“TH”
• Filtersshouldonlybettedtothepowerunit,donotattempttotthemdirectlytoahoodorhelmet.
7. PREPARATION FOR USE
Allpreparationsandmaintenanceshouldbecarriedoutinacleanenvironment.
Battery (0700 002 164)
TheAristoairpowerunitisttedwithare-chargeableLi-ion(Lithiumion)batterypack.
Batteriesaresuppliedinadischargedcondition,andmustinitiallybechargedbeforeuse.
Allrechargeablebatteriesdeteriorateovertimeandshouldbereplacedwhentheynolongerlasttherequiredduration.
Thebatterymayrequiremorethanonefullchargebeforereachingoptimumcapacity.
Thebatterieshaveanexpectedlifeof500chargeswhenchargedinaccordancewiththeseinstructions.
ThesebatteriesmustonlybeusedonAristoAirpowerunit.
Batteriesmustbechargedwithbatterycharger(0700002165)–theuseofanyotherchargermayresultindamagetoboththebatteryand
charger.
Batteriesmaybechargedonorofftheunit.
Exactdurationwilldependonanumberoffactorssuchaslterstate,batteryage/condition,temperatureandairowleveltowhichtheunitis
beendriven.
Typicalbatterydurationfromfullcharge-7-8Hours@210l/min11-12Hours@175l/min
Important:Neverchargeabatteryinanatmosphere,whichis,orcouldbecomepotentiallyexplosive
Battery Charger (0700 002 165)
OPERATION INSTRUCTIONS:
1. Disconnectchargerfromelectricitysupply.
2. Toattachanalternativeplugtype-Pushupswitchmarked“Open”inthedirectionofthearrow,theplugwillpopout.Insertthe
plug(suitablefortheelectricitysupply)intothechargerpushingrmlyuntilit“clickshome”(Fourdifferentchangeableplugsare
suppliedwiththecharger(UK,SAA,EUandUS),onlyusethecorrectplugforyourelectricitysupply.
3. Connectchargertoelectricitysupplyviasuitableelectricalsocket.
4. Connecttheplugofthebatterychargerintothesocketofthebatterypack.
5. TheLED(ontopofthecharger)willilluminateREDtoindicatechargingprocessandwillchangetoGREENwhenthebatterypack
isfullycharged.(Whenthebatterypackisfullycharged,thebatterychargerwillautomaticallyswitchtoaminimummaintenance
charge).
6. Unplugthechargerandremovethebatteriesfromtheunitwhennotinuse
IMPORTANT SAFETY INSTRUCTIONS:
1. UseonlyLithium-ion(Li-ion)batterypacksinthecharger.Donotattempttorechargeanynon-rechargeablebatterypacks.
2. Thischargerisdesignedforindooruseonly.
3. Donotexposethechargertohightemperaturesorallowmoistureorhumidityofanykindtocomeintocontactwiththecharger.Do
notcoverchargeratanytime.
4. Thechargershouldnotbeusedbyminors.
5. Donotattempttoopenthecharger.Repairsshouldonlybecarriedoutbyaqualiedservicecentre.
6. Alwaysdisconnectthechargerifitisnotinuse.
7. Neveruseanextensioncordoranyattachmentifnotrecommendedbymanufacturer.Thismaycauseariskofre,electricshock
orinjurytopersons.
NoteIftheAristoAirpowerunitistobestoredwithoutuseforaperiodoftime,thebatterymustbedetachedfromthepowerunit.
Main lter
WARNING This ARISTO Air power unit offers NO protection unless a Main lter is tted.
Care should be taken when handling lters.
Do not touch the pleated paper lter medium.
Do not use lters with damaged paper lter medium.
Do not use lters after their expiry date.
Do not use lters with no or damaged lter seal.
Do not attempt to clean a lter, once fully loaded they must be replaced.
Filters should be tted as follows:
RemovethefrontcoverbyreleasingtheretainingclipononesideoftheAristoAirunitbyhand(donotusetools).