- WATERFLASH 2003 -
4.
www.actana.fr
Troubleshooting: how to diagnose problems and remedy them.
Problem Cause Solution
Poor evacuation.
The aspiropulsor is connected and the
water supply is open but the evacuation
doesn't work.
1/ The outpipe is blocked or bent.
2/ An inappropriate object has been
thrown in the bowl and is blocking the
turbine.
3/ The condenser on the motor is
malfunctioning.
4/ The thermal security is activated.
5/ The electronic cycle is defectuous
6/ A fuse has blown.
1/ Check the outlet pipe.
3/ Open the inspection hatch and remove the object.
4/ Change the condenser.
5/ Allow the motor to cool for 5 to 10 minutes.
6/ Change the condenser.
Nothing happens when the push-button is
pressed.
1/ The transparent tube is detached.
2/ Power cut.
3/ Problem in the electronic cycle.
4/ The pressostat is malfunctioning.
1/ Verify and reconnect it, verify the connection of the
pneumatic button.
2/ Test the power supply.
3/ Change the timer control.
4/ Change the pressostat..
The aspiropulsor functions but the water
doesn't flow.
1/ Problem in the water inlet
2/ Blocked filter on the turbine
3/ Turbine malfunctioning
4/ Problem in the electronic cycle.
1/ Verify the water supply at the tap.
2/ Unscrew the "stop-shock" tube and clean the filter.
3/ Change the turbine
4/ Change the timer control
The water cycle fails to stop 1/ Turbine malfunctioning.
2/ Defect in the electronic cycle control.
1/ If after disconnecting the power supply the water
continues to flow, change the turbine.
2/ If the water stops flowing, change the timer control.
At the end of the cycle the water level is not
restored
1/ Siphoning 1/ Put on air gape on the waste pipe.
Water leak in the rinsing. 1/ Too much pressure on the water
supply.
1/ Interpose a reducer of pressure to bring the pressure
to 3 bars maxi.
2/ Verify the good fitting of the pipe of rinsing.
The cycle sees out systematically
continuously.
1/ Defective electronic cycle. 1/ Change the timer.
The aspiropulser works only during 1 or 2
seconds.
1/ Defective electronic cycle.
2/ Defective thermic protection.
1/ Change the timer.
2/ Change the aspiropulser.