ACTANA WATERFLASH 2003 Technical Manual

Type
Technical Manual
- WATERFLASH 2003 -
1.
www.actana.fr
Technical manual
WATERFLASH 2003
General presentation
WATERFLASH 2003 is only on the range equiped with a watertight motor, available for public
installation, hotel and everywhere with a humidity risk.
WATERFLASH 2003 is composed by :
- a ceramic vitrified pan,
- available in 10 colors,
- equiped with reverse operation.
ACTANA Commercial and manufacture
19, rue de l’industrie - ZI « La Petite Motte »
77220 TOURNAN EN BRIE
Tél. :00.33.1 64 06 43 60
Fax : 00.33.1 64 06 43 66
- WATERFLASH 2003 -
2.
www.actana.fr
Technical characteristics
- Vitreous china
- ASPIROPULSOR
- Choice of 15 colors
- Reverse operation
- Plug of visit
- With seat. cover
- Evacuation, rinsing and restoration of the water level is entirely automatically activated by a simple
touch of the pneumatic control button : cycle time 20 seconds.
TYPE MONOBLOC
Dimensions 490x345x435
Motor Asynchrone
Power 450 Watts
Voltage 230 V.
Intensity 2.8 A
Electronical class Classe II
Weight 34 Kg
Evacuation pressure 1 bar
Inlet water pressure 3 bars maxi
Drainage 50 meters on the same level,
6 meters if pumping vertically in 25mm diameter
tubing.
Vertical evacuation in Ø internal 25 or 26 mm
intérieur
6m
Principle of functionning of WATERFLASH 2003
Synoptic
Automatic command
The WATERFLASH works by pneumatic command, it is enough to press on the small opening in the
middle of the button to start the following cycle:
- Inflow of water of rinsing for about 8 seconds.
- Start on of the aspiropulsor simultaneously with the drainage of the water for 3 seconds (or 6
seconds in the case of a vertical ascent).
The motor is completly water tight.
Rinsing Aspiration and rinsing Add some water
Having lasted 8 s. Having lasted 3 s. oru 6
s
Having lasted 7 s.
- WATERFLASH 2003 -
3.
www.actana.fr
Fragmented sight WATERFLASH 2003
1. Pressostat
2. Support for time switch
3. Timer
4. Aspiropulser
5. Capacitor
6. Turbine
7. Peg
8. Frame
9. Button rivet
10. Frame screw
11. Aspiropulser casing
12. Cable collar
13. Electric cable
14. Hose clip
15. Aspiration pipe
16. Clip
17. Evacuation pipe
18. PVC bend
19. Sleeve
20. Flexible tube
21. Rinsing bend
22. Rinser
23. Linking pipe
24. Electrovanne casing
25. Electrovanne coil
26. Intervention plug
27. Push button
28. Ring
29. Embase
30. Clear tubing
31. Pal nut
32. Rislan clip
33. Time switch screws
34. Corner plate
35. Nylon nut and bolt
36. Bolt on pump casing
37. Rubber joint
38. Click clip
39. Electrovalve wiring
40. Class II
- WATERFLASH 2003 -
4.
www.actana.fr
Troubleshooting: how to diagnose problems and remedy them.
Problem Cause Solution
Poor evacuation.
The aspiropulsor is connected and the
water supply is open but the evacuation
doesn't work.
1/ The outpipe is blocked or bent.
2/ An inappropriate object has been
thrown in the bowl and is blocking the
turbine.
3/ The condenser on the motor is
malfunctioning.
4/ The thermal security is activated.
5/ The electronic cycle is defectuous
6/ A fuse has blown.
1/ Check the outlet pipe.
3/ Open the inspection hatch and remove the object.
4/ Change the condenser.
5/ Allow the motor to cool for 5 to 10 minutes.
6/ Change the condenser.
Nothing happens when the push-button is
pressed.
1/ The transparent tube is detached.
2/ Power cut.
3/ Problem in the electronic cycle.
4/ The pressostat is malfunctioning.
1/ Verify and reconnect it, verify the connection of the
pneumatic button.
2/ Test the power supply.
3/ Change the timer control.
4/ Change the pressostat..
The aspiropulsor functions but the water
doesn't flow.
1/ Problem in the water inlet
2/ Blocked filter on the turbine
3/ Turbine malfunctioning
4/ Problem in the electronic cycle.
1/ Verify the water supply at the tap.
2/ Unscrew the "stop-shock" tube and clean the filter.
3/ Change the turbine
4/ Change the timer control
The water cycle fails to stop 1/ Turbine malfunctioning.
2/ Defect in the electronic cycle control.
1/ If after disconnecting the power supply the water
continues to flow, change the turbine.
2/ If the water stops flowing, change the timer control.
At the end of the cycle the water level is not
restored
1/ Siphoning 1/ Put on air gape on the waste pipe.
Water leak in the rinsing. 1/ Too much pressure on the water
supply.
1/ Interpose a reducer of pressure to bring the pressure
to 3 bars maxi.
2/ Verify the good fitting of the pipe of rinsing.
The cycle sees out systematically
continuously.
1/ Defective electronic cycle. 1/ Change the timer.
The aspiropulser works only during 1 or 2
seconds.
1/ Defective electronic cycle.
2/ Defective thermic protection.
1/ Change the timer.
2/ Change the aspiropulser.
- WATERFLASH 2003 -
5.
www.actana.fr
Pressure switch
Before may 2000 :
Be careful :
Before every modification disconect the electricity supply.
Since may 2000 :
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5