Twin Eagles Premium Grill Gas Conversion Instruction

Type
Gas Conversion Instruction
In Massachuses: All gas products must be installed using a “Massachuses” licensed plumber
or gas er. A “T” handle type manual gas valve must be installed in the gas supply line to this
appliance. This applies to permanently installed natural gas and propane installaons. This
does not apply to propane portable installaons using a 20 pound tank.
PN: 18567F 04/19
GAS CONVERSION KIT FROM LP TO NG, P/N CKNG-TEBQ
FOR MODELS: TWIN EAGLES GRILLS, TEBQ/TPBQ
1. All gas connecons/conversions should be made by a qualied technician and in
accordance with local codes and ordinances.
2. Before conducng a conversion to a gas appliance, verify that the main gas is shut o and
disconnected from the appliance.
3. Ensure that you have the LP Gas Conversion Kit , as follows:
A. P/N 15110-41, Orice #41, NG, Grill Burner (3 pcs.)
B. P/N 15108-50, Orice #50, Ros/ Small IR, for TEBQ30/TEBQ36/TPBQ30, NG (1 pc.)
C. P/N 15108-48, Orice #48, Ros/ Large IR, for TEBQ42/TPBQ42, NG (1 pc.)
D. P/N 15303, Regulator, Natural Gas (1 pc.)
E. P/N 18351, Label, Conversion, Gas (1 pc.)
4. Replace burner valve orices.
A. Grill Burner:
a. Remove cooking grates
b. Remove briquee trays
c. Remove grill burners
d. Remove grill burner orices, #53 drill size
e. Replace grill burner orices with #41 drill size
f. Adjust the burner shuer for the appropriate gas type. (An “L” and an “N” are
stamped on the air shuer to indicate the appropriate gas type.)
g. Install back the burners, briquee trays & cooking grates. WARNING! IT IS
CRITICAL THAT THE GAS BURNERS ARE PROPERLY INSTALLED WITH THEIR
ORIFICES INSIDE THE BURNERS AIR SHUTTERS. If not properly installed, gas may
leak outside of the burner that could lead to re, potenal damage to your grill
and bodily injury
B. Infrared Rosserie Burner
a. Remove rear hood cover to expose infrared burner gas orice
b. Remove ros burner orice, as follows:
i. # 57 from the 30” grill, TEBQ30/TEBQ36/TPBQ30
ii. # 56 from the 42” grill, TEBQ42/TPBQ42
c. Replace ros burner orice with:
i. Orice # 50 for 30” grill, TEBQ30/TEBQ36/TPBQ30
ii. Orice # 48 for 42” grill, TEBQ42/TPBQ42
d. Replace rear hood cover.
5. Replace the LP regulator with the factory supplied NG regulator.
A. Disconnect regulator and hose from the LP bole
B. Remove the brass coupling from the grill manifold
C. Install regulator directly to grill manifold pipe. Make sure that the arrow mark on the
regulator is poinng towards the grill.
D. Check for gas leaks using soapy water soluon.
6. NEVER USE THE GRILL WITHOUT FIRST LEAK TESTING THE GAS CONNECTION.
A. Prepare a leak tesng soluon of sudsy water by mixing in a spray bole with half
liquid soap and half water.
B. Conrm that all control knobs are in the “OFF” posion.
C. Turn the main gas valve supply “ON”.
D. Apply leak tesng soluon by spraying on the pipe joints, ngs, and hose.
E. A gas leak is detected if;
a. there is a faint gas smell and/or
b. growing bubbles appear on any of the connecon points and/or hose. DO NOT
aempt to ignite the grill and IMMEDIATELY turn o the gas supply valve.
F. When there is a gas leak, call a qualied service technician. DO NOT use the grill unl
the leak is corrected.
7. Calibrate burner low ame seng
A. The grill must be hooked up to the gas supply in order to calibrate burner.
B. Turn on burner and set to low. At low seng, all ports of the burner must remain lit.
If the ames are too high or too low, calibrate burner valve.
C. To calibrate burner valve, pull o valve knob. Insert a skinny at screwdriver into the
valve stem
D. Turn the adjusng screw inside the stem clockwise to decrease ame or counter
clockwise to increase ame.
E. Perform leak test on the valve stem using the soapy water soluon.
8. The conversion is complete. Fill up the Conversion Label. Next, paste it next to the original
Serial Plate.
9. The unit is ready for installaon. Please refer back to the Users Manual to insure safety,
proper care and operaon.
WARNING: CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including carbon monoxide which is known to the
State of California to cause cancer and reproducve harm. To minimize exposure to the by-
products of the burning fuel or from combuson, always operate this unit according to the
use and care manual and provide good venlaon. California law requires businesses to warn
customers of potenal exposure to such substances. For more informaon go to
www.P65Warnings.ca.gov.
AVERTISSEMENT: PROPOSITION 65 DE L’ETAT DE LA CALIFORNIE
Cet appareil peut vous exposer aux produits chimiques et au gaz monoxyde de carbonne
reconnue dans l’Etat de la Californie pour causer le cancer et des problemes de ferlite. Pour
minimiser l’exposion de ces-sous produits combusbles ou de la combuson, uliser toujours
cet appareil en conformitee au manuel d’ulisaon et d’entreen en s’assurant egalement
d’une bonne venlaon. La loi de la Californie exige aux fabricants d’informer leurs clients aux
risques d’exposion potenelle a de telles substances. Pour plus d’informaon, visiter le site
www.P65Warnings.ca.gov
  • Page 1 1

Twin Eagles Premium Grill Gas Conversion Instruction

Type
Gas Conversion Instruction

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages