Kohler 12100-C-0 Installation guide

Type
Installation guide

This manual is also suitable for

Installation Guide
One-Piece Barrier-Free Shower Modules
K-12100, K-12101, K-12102,
K-12103, K-12104, K-12107,
K-12108, K-12109, K-12110,
K-12111, K-12112, K-12113
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de M corresponden a México
(Ej. K-12345M)
Français, page “Français-1”
Español, página “Español-1”
1030529-2-B
Tools and Materials
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before
you start installation. If you encounter any installation or performance problems, please don’t hesitate to
contact us. Our phone numbers and website are listed on the back cover. Thanks again for choosing Kohler
Company.
Before You Begin
CAUTION: Risk of product damage. Install the shower module on an adequately supported, level
subfloor. The shower module requires no additional support when the subfloor is level and square
with the stud framing. Use shims for additional support if the subfloor is uneven. Do not install the
shower module over open floor joists.
CAUTION: Risk of product damage. To avoid rust marks on your product, ensure the large head nails
or screws are galvanized. If using galvanized screws, do not overtighten the screws. Excessive
tightening can damage the wall flange.
Please read these instructions carefully to familiarize yourself with the required tools, materials, and
installation sequences. Follow the sections that pertain to your particular installation. This will help
you to avoid costly mistakes.
Observe all local plumbing and building codes.
A variety of installations are possible. These instructions show suggested installation procedures.
Your particular installation may require other construction techniques.
Avoid flexing the side walls to prevent damage to the module.
Unpack and inspect the shower module for damage. If you find any damage, do not install the
module. Report the specific problem to your dealer immediately. After inspection, return the shower
module to the carton until you are ready to install it.
Insulate all exterior walls before installation.
You must install this shower module to an adequately supported, level subfloor.
Be sure that you have enough access to move the module into the construction area. One-piece
shower modules are too large to fit through standard door openings. Set the module within the
installation area prior to the completion of the framing. Another option is not to install the studs in
one wall or install the studs without nailing, to allow you to move the module into place.
Plus:
• Common Woodworking Tools
and Materials
• Galvanized #6 Large Head
Screws or Nails
• Drop Cloth
• 2x4s or 2x6s and 2x2s
• Water Resistant Wall Material
• Hole Saw
Pencil
Level
Sealant
Screwdriver
Drill
Claw
Hammer
KnifeSquare
Plumbers
Putty
Tape
Measure
Safety
Glasses
1030529-2-B 2 Kohler Co.
Before You Begin (cont.)
Before installation, provide access at the back of the plumbing wall. Because the module is
one-piece, the drain and overflow connections cannot be made by reaching over the end of the
module.
Make sure the installation area is clean and free of all debris. If remodeling, remove all finished wall
material to expose the framing and remove all floor coverings to expose the subfloor.
Consult all applicable instructions for options and accessories before beginning this installation.
Fixture conforms to ANSI Standard Z124.2. All dimensions are nominal.
Kohler Co. reserves the right to make revisions in the design of products without notice, as specified
in the Price Book.
Roughing-In Provisions
IMPORTANT! All dimensions are nominal. The stud opening tolerance is +1/4 (6 mm)/-0. Carefully
measure your fixture before determining enclosure size. Some shimming between the stud frame and the
fixture may be required. If a firewall is required, rough-in dimensions will have to increase according to
the thickness of the firewall material. Stud opening dimensions must be measured toward the exposed
side of the wall material. When a fire-rated wall is specified, dimensions are to the inside of the wall
board. Dimensions given in the rough-in information are crucial for proper installation. Construct the
framing and plumbing accurately.
NOTE: The basin area requires no additional support when the subfloor is level and square with respect to
the framing. Consider using shims for additional support if the subfloor is uneven.
ADA Provisions
These models comply with the Americans with Disabilities Act when installed per the requirements
of the Accessibility Guidelines, Section 4.21 Shower Stalls, of the Act. Consider the user’s physical
limitations when determining the position of the module and the location of the shower control
area(s). To ensure ADA compliance, position the module exactly as shown in the roughing-in
diagram. Locate the shower control areas as illustrated.
Provide clear floor space according to the roughing-in illustrations. You can provide the clear floor
space with either a front or side user access. Consider the path of the wheelchair user when
building the clear floor space. Be sure there is sufficient room for a wheelchair user to enter the
room and maneuver the wheelchair to the module.
When possible, a side entrance to the module should be employed to ensure the easiest wheelchair
accessibility.
If the user will have caregiver assistance, we recommend using a front entrance.
Kohler Co. 3 1030529-2-B
Roughing-In
K-12103 LH Drain
K-12104 RH Drain
K-12102
34-5/8" (87.9 cm)
60-1/4" (153 cm)
*69-1/4" (175.9 cm)
3/8" (1 cm)
2-1/2" (6.4 cm)
Elbow Supply
2-1/2"
(6.4 cm)
9-1/4"
(23.5 cm)
37-1/2"
(95.3 cm)
3/4"
(2 cm)
27"
(68.6 cm)
Max.
*84"
(213.4 cm)
5"
(12.7 cm)
1-5/16"
(3.3 cm)
3-1/4"
(8.3 cm)
C
L Spout
Elbow Supply
5" (12.7 cm)
37" (94 cm)
7/8" (2.2 cm)
9" (22.9 cm)
56" (142.2 cm)
*64-3/4" (164.5 cm)
3/4" (2 cm)
3" (7.6 cm)
2-7/8" (7.3 cm)
19"
(48.3 cm)
1-5/16"
(3.3 cm)
3"
(7.6 cm)
*84"
(213.4 cm)
20"
(50.8 cm)
4" (10.2 cm)
18"
(45.7 cm)
13"
(33 cm)
1-1/2"
OD
4" (10.2 cm)
60" (152.4 cm)
60" (152.4 cm)
Represents control area for faucets
Represents 24" (61 cm) wall mount slide bar.
Represents clear floor space for 48" (121.9 cm) x
60" (152.4 cm) front entrance.
36"
(91.4 cm)
48"
(121.9 cm)
*Recess opening must be 69-1/2" (176.5 cm) x 84-1/4" (214 cm).
60" (152.4 cm)
60" (152.4 cm)
No change in measurements if connected
with drain illustrated. (K-7161-AF)
Represents clear floor
space for 36" (91.4 cm) x
60" (152.4 cm) side
entrance.
Represents clear floor
space for 48" (121.9 cm)
x 60" (152.4 cm) front
entrance.
Represents 24" (61 cm)
wall mount slide bar.
Represents control area
for faucets.
*Recess opening must be 65" (165.1 cm) x
84-1/4" (214 cm).
48"
(121.9 cm)
36"
(91.4 cm)
Represents clear floor space for 36" (91.4 cm) x
60" (152.4 cm) side entrance.
Models K-12102, K-12103, K-12104
1030529-2-B 4 Kohler Co.
Roughing-In
36" (91.4 cm)
*45" (114.3 cm)
2-1/2" (6.4 cm) 1/2" (1.3 cm)
37-3/ 4"
(95.9 cm)
2-1/2" (6.4 cm)
18"
(45.7 cm)
Max
*84"
(213.4 cm)
3-1/4"
(8.3 cm)
1-1/4"
(3.2 cm)
37"
(94 cm)
22-1/2"
(57.2 cm)
3/4"
(1.9 cm)
36" (91.4 cm)
36" (91.4 cm)
Represents control area for faucets
Represents 24" (61 cm) wall mount slide bar.
Represents clear floor space for 36" (91.4cm) x
36" (91.4 cm) side entrance.
Represents clear floor space for 48" (121.9 cm) x
36" (91.4 cm) front entrance.
36"
(91.4 cm)
48"
(121.9 cm)
*Recess opening must be 45-1/4" (114.9 cm) x 84-1/4" (214 cm).
9" (22.9 cm)
36" (91.4 cm)
*45" (114.3 cm)
2-1/2" (6.4 cm) 1/2" (1.3 cm)
2-1/2"
(6.4 cm)
Elbow
Supply
*84"
(213.4 cm)
19"
(48.3 cm)
3-1/4"
(8.3 cm)
1-1/4"
(3.2 cm)
37"
(94 cm)
22-1/2"
(57.2 cm)
3/4" (1.9 cm)
18"
(45.7 cm)
Max
5" (12.7 cm)
Elbow
Supply
5"
(12.7 cm)
9"
(22.9 cm)
K-12100 R Fold-up Seat
K-12101 L Fold-up Seat
K-12107 L Soap Ledge
K-12108 R Soap Ledge
37-3/ 4"
(95.9 cm)
Models K-12100, K-12101, K-12107, K-12108
Kohler Co. 5 1030529-2-B
Roughing-In
43" (109.2 cm)
43" (109.2 cm)
Represents control area for faucets
Represents 24" (61 cm) wall mount slide bar.
Represents clear floor space for 36" (91.4 cm) x 43" (109.2 cm)
side entrance.
Represents clear floor space for 48" (121.9 cm) x 43" (109.2 cm)
front entrance.
36"
(91.4 cm)
48"
(121.9 cm)
*Recess opening must be 52-1/4" (132.7 cm) x 84-1/4" (214 cm).
26" (66 cm)
43" (109.2 cm)
*52" (132.1 cm)
37"
(94 cm)
19"
(48.3 cm)
*84"
(213.4 cm)
3-1/4"
(8.3 cm)
5"
(12.7 cm)
1-1/4"
(3.2 cm)
Elbow Supply
2-1/2"
(6.4 cm)
37-1/2"
(95.3 cm)
9" (22.9 cm)
3/4" (2 cm)
18"
(45.7 cm)
Max
3-1/4" (8.3 cm)
1/2" (1.3 cm)
K-12109 L Seat
K-12110 R Seat
Models K-12109, K-12110
No change in measurements if connected with drain illustrated.
(K-9132)
1030529-2-B 6 Kohler Co.
Roughing-In
K-12111 L Seat
K-12112 R Seat
9" (22.9 cm)
26" (66 cm)
43" (109.2 cm)
*52" (132.1cm)
2-1/2" (6.4 cm)
37-1/2"
(95.3 cm)
3/4" (2 cm)
2-1/2"
(6.4 cm)
Elbow
Supply
1-1/4"
(3.2 cm)
3-1/4"
(8.3 cm)
37"
(94 cm)
18" (45.7 cm) Max
*84"
(213.4 cm)
19"
(48.3 cm)
Elbow Supply
5" (12.7 cm)
1/2" (1.3 cm)
3/4" (2 cm)
3-1/4" (8.3cm)
*52" (132.1 cm)
43" (109.2 cm)
9"
(22.9 cm)
37-1/2"
(95.3 cm)
2-1/2"
(6.4 cm)
26"
(66 cm)
1-1/4"
(3.2 cm)
18"
(45.7 cm)
Max
3-1/4"
(8.3 cm)
*84"
(213.4 cm)
37" (94 cm)
K-12113
43" (109.2 cm)
43" (109.2 cm)
Represents control area for faucets
Represents 24" (61 cm) wall mount slide bar.
Represents clear floor space for 36" (91.4 cm) x 43" (109.2 cm)
side entrance.
Represents clear floor space for 48" (121.9 cm) x 43" (109.2 cm)
front entrance.
36"
(91.4 cm)
48"
(121.9 cm)
No change in measurements if connected with drain illustrated.
(K-9132)
*Recess opening must be 52-1/4" (132.7 cm) x 84-1/4" (214 cm).
1/2"
(1.3 cm)
5" (12.7 cm)
Models K-12111, K-12112, K-12113
Kohler Co. 7 1030529-2-B
1. Install the Pit (Optional)
Concrete Pit Installation
Use a concrete pit installation when a low outside threshold is either required or desired.
The finished floor must be no more than 1/2 (1.3 cm) below the top of the outside threshold. For
the easiest wheelchair entry and exit, the finished floor should be flush with the outside threshold of
the module.
A typical tile installation will require a 3/4 (1.9 cm) minimum pit into the subfloor.
Make sure the subfloor is flat and level.
Wood-Framed Sunken Installation
Framing must be similar to the framing used in a stairwell.
The designer or architect should specify the quantity and size of the reinforcing joists and headers.
Size the joists, subflooring, underlayment, and floor covering to make the finished floor flush with
the module threshold height or a maximum of 1/2 (1.3 cm) below the module threshold height.
Make sure the subfloor is flat and level.
Wheelchair Ramp Alternative
Build a wheelchair ramp above the subfloor up to the outside threshold of the module.
Make sure the subfloor is flat and level.
2" (5.1 cm)
to 3-1/4"
(8.3 cm)
3-1/4"
(8.3 cm)
Tile or Floor
Covering
2" (5.1 cm)
to 3-1/4"
(8.3 cm)
Tile or Floor
Covering
2" (5.1 cm)
to 3-1/4"
(8.3 cm)
Tile or Floor
Covering
Concrete
Underlayment
Subfloor
Floor Joists
Ramp
Subfloor
Module Threshold
Module Threshold
Module Threshold
Concrete Wood-Framed Wheelchair Ramp
1030529-2-B 8 Kohler Co.
2. Prepare the Site
ABCD
K-12100/K-12101 45-1/4 (114.9 cm) 9 (22.9 cm) 37 (94 cm) 22-1/2 (57.2 cm)
K-12102 69-1/2 (176.5 cm) 9-1/4 (23.5 cm) 37-1/2 (95.3 cm) 34-5/8 (90.5 cm)
K-12103/K-12104 65 (165.1 cm) 18 (45.7 cm) 37 (94 cm) 13 (33 cm)
K-12107/K-12108 45-1/4 (114.9 cm) 9 (22.9 cm) 37 (94 cm) 22-1/2 (57.2 cm)
K-12109/K-12110/K-12111/
K-12112/K-12113
52-1/4 (132.7 cm) 9 (22.9 cm) 37-1/2 (95.3 cm) 26 (66 cm)
NOTE: If the unit will be installed against a masonry wall, make provisions for plumbing connections.
Construct a separate frame wall a minimum of 6 (15.2 cm) from the masonry wall.
IMPORTANT! If a shower door will be installed, refer to the shower door installation instructions for any
special framing considerations.
IMPORTANT! Do not install the header and right side of the front frame until the module has been
moved into place.
Make sure the subfloor is level and adequately supported before proceeding.
Construct 2x4 or 2x6 framing according to the roughing-in information for your particular model.
Nail in a 2x2 brace around the recess opening.
Verify that the framing is square and plumb.
Add any bridging or support needed if you are installing grab bars or towel bars. Refer to the
accessory manufacturer’s instructions.
3. Install the Plumbing
NOTE: Provide access at the back of the plumbing wall for servicing the supply and waste piping.
Locate rough plumbing for the drain according to the correct model’s roughing-in dimensions.
Cuta5 (12.7 cm) diameter hole in the floor at the drain location.
NOTE: If plumbing is to be installed on the unfinished stud wall, install the supplies after the module is
installed.
Position the plumbing according to the roughing-in information.
Cap the supplies and check for leaks.
Install a drain pipe according to the roughing-in information.
Strap the supply connections to the stud framing.
84-1/4"
(214 cm)
A
D
C
B
2x2
Brace
Nail the header with a 2x2 brace
to the framing after setting the
module into the recess.
NOTE: The framing shown may not
represent the actual proportions for
your particular model.
6" (15.2cm) Min
2x4 Stud Framing
Masonry Wall
Kohler Co. 9 1030529-2-B
Install the Plumbing (cont.)
Provide access at the back of the plumbing wall to make drain connections to the receptor.
Install the shower valving according to the manufacturer’s instructions. Do not install the trim at
this time.
4. Prepare the Module
CAUTION: Risk of property damage. Make sure a watertight seal exists around the drain. If a
watertight seal on the drain is not obtained, water damage to the subfloor may occur.
Install the drain to the module according to the drain manufacturer’s instructions.
Layout and mark the location of the mixing valve, shower, and the bath spout holes on the back
surface of the module wall.
NOTE: If the supply fittings have been located accurately during rough fitting, a pilot hole template can be
used for multiple installations. Make a pilot hole template of lightweight plywood. Use the pilot hole
template to mark fitting locations on the back side of the module.
Drill 1/4 (6 mm) pilot holes at the marked locations.
Clean the module to reduce the risk of surface damage.
Place a clean drop cloth or other similar material into the bottom of the module.
From the inside of the module (finished surface), use a hole saw of the correct diameter to carefully
drill the fitting holes.
Clean any debris from the module to reduce the risk of surface damage. Be careful not to scratch the
surface of the unit.
1030529-2-B 10 Kohler Co.
5. Position the Module
Move the module into position.
Fit the drain into the trap.
Verify that the bottom of the module is firmly supported by the floor. No additional support is
needed.
Verify proper fit.
Verify the module is plumb and level to ensure proper shower enclosure installation. Make framing
adjustments or shim, if necessary.
Position the right side of the front frame and the header in the recess and nail into place.
Verify that the framing and headers are square and plumb.
Do not secure the nailing-in flanges at this time.
6. Secure the Module
CAUTION: Risk of property damage. Make sure a watertight seal exists around the drain. If a
watertight seal on the drain is not obtained, water damage to the subfloor may occur.
Complete the drain installation according to the instructions packed with the drain.
If not already installed, install the supplies and shower valving at this time. See Install the
Plumbing.
Open the water supplies and check all the connections for leaks.
Run water into the module and check the drain connections for leaks.
Drill holes in the front nailing-in flanges and 2x2 braces at 18 (45.7 cm) centers.
Secure the nailing-in flanges to the 2x2 braces at the pre-drilled locations using #6 large head
galvanized nails or screws. Be careful when nailing, not to damage the finished surfaces.
#6 Large Head
Galvanized Nail
Nailing-In Flange
2x2 Brace
Kohler Co. 11 1030529-2-B
7. Complete the Installation
Flush Installations
Install water-resistant wall material to within 1/4 (6 mm) of the module edge.
Install desired trim (not provided) around the unit to conceal the module edge.
Also install trim along the bottom apron edge.
Alcove Installations
Install water-resistant wall material around the unit to conceal the module edge.
All Installations
Apply a bead of silicone sealant to the nailing-in flanges.
Install water-resistant wall material with the paperbound edge a maximum of 1/4 (6 mm) above
the finished, concave surface of the module.
Tape and mud the wall material.
Seal around the valving and outlets with silicone sealant or plumbers putty.
Install the faucet and drain trim according to the faucet manufacturer’s instructions.
If applicable, install the grab bars and towel bars. Refer to the accessory manufacturer’s instructions
to properly secure the accessory to the wall surround.
If applicable, install the shower door according to the manufacturer’s instructions. Only apply
sealant where instructed to do so.
Clean up with a non-abrasive cleaner.
Flush Installation
(Top Down View)
2x4 Studs
Module
1x2 Brace
Water-Resistant
Wall Material
Tr im
1/4" (6mm) Gap
Alcove Installation
(Top Down View)
Module
1x2 Brace
1/4" (6mm)
Gap
Water-Resistant
Wall Material
2x4 Studs
1030529-2-B 12 Kohler Co.
Plan de raccordement
Drain G K-12103
Drain D K-12104
K-12102
34-5/8" (87,9 cm)
60-1/4" (153 cm)
*69-1/4" (175,9 cm)
3/8" (1 cm)
2-1/2" (6,4 cm)
Alimentation
coude
2-1/2"
(6,4 cm)
9-1/4"
(23,5 cm)
37-1/2"
(95,3 cm)
3/4"
(2 cm)
27"
(68,6 cm)
Max.
*84"
(213,4 cm)
5"
(12,7 cm)
1-5/16"
(3,3 cm)
3-1/4"
(8,3 cm)
C
G Bec
Alimentation
coude
5" (12,7 cm)
37" (94 cm)
7/8" (2,2 cm)
9" (22,9 cm)
56" (142,2 cm)
*64-3/4" (164,5 cm)
3/4" (2 cm)
3" (7,6 cm)
2-7/8" (7,3 cm)
19"
(48,3 cm)
1-5/16"
(3,3 cm)
3"
(7,6 cm)
*84"
(213,4 cm)
20"
(50,8 cm)
4" (10,2 cm)
18"
(45,7 cm)
13"
(33 cm)
Ø Ext.
1-1/2"
4" (10,2 cm)
60" (152,4 cm)
60" (152,4 cm)
Représente la zone de manoeuvre des robinets
Représente une barre coulissante murale de
24" (61 cm).
Représente le dégagement au sol de 48"
(121,9 cm) x 60" (152,4 cm) pour une entrée
frontale.
36"
(91,4 cm)
48"
(121,9 cm)
*L'ouverture de la cavité doit être de 69-1/2" (176,5 cm) x
84-1/4" (214 cm).
60" (152,4 cm)
60" (152,4 cm)
Aucun changement des mesures n'est
nécessaire si connecté au drain illustré.
(K-7161-AF)
Représente le dégagement
au sol de 36" (91,4 cm) x
60" (152,4 cm) pour une
entrée latérale.
Représente le dégagement
au sol de 48" (121,9 cm) x
60" (152,4 cm) pour une
entrée frontale.
Représente une barre
coulissante murale de
24" (61 cm).
Représente la zone de
manoeuvre des robinets.
*L'ouverture de la cavité doit être de 65"
(165,1 cm) x 84-1/4" (214 cm).
48"
(121,9 cm)
36"
(91,4 cm)
Représente le dégagement au sol de 36"
(91,4 cm) x 60" (152,4 cm) pour une entrée
latérale.
Modèles K-12102, K-12103, K-12104
Kohler Co. Français-3 1030529-2-B
Plan de raccordement
36" (91,4 cm)
*45" (114,3 cm)
2-1/2" (6,4 cm) 1/2" (1,3 cm)
37-3/4"
(95,9 cm)
2-1/2" (6,4 cm)
18"
(45,7 cm)
Max.
*84"
(213,4 cm)
3-1/4"
(8,3 cm)
1-1/4"
(3,2 cm)
37"
(94 cm)
22-1/2"
(57,2 cm)
3/4"
(1,9 cm)
36" (91,4 cm)
36" (91,4 cm)
Représente la zone de manoeuvre des robinets
Représente une barre coulissante murale de
24" (61 cm).
Représente le dégagement au sol de 36" (91,4 cm)
x 36" (91,4 cm) pour une entrée latérale.
Représente le dégagement au sol de 48" (121,9 cm)
x 36" (91,4 cm) pour une entrée frontale.
36"
(91,4 cm)
48"
(121,9 cm)
*L'ouverture de la cavité doit être de 45-1/4" (114,9 cm) x 84-1/4"
(214 cm).
9" (22,9 cm)
36" (91,4 cm)
*45" (114,3 cm)
2-1/2" (6,4 cm) 1/2" (1,3 cm)
2-1/2"
(6,4 cm)
Alimentation
coude
*84"
(213,4 cm)
19"
(48,3 cm)
3-1/4"
(8,3 cm)
1-1/4"
(3,2 cm)
37"
(94 cm)
22-1/2"
(57,2 cm)
3/4" (1,9 cm)
18"
(45,7 cm)
Max
5" (12,7 cm)
Alimentation
coude
5"
(12,7 cm)
9"
(22,9 cm)
Siège pliable D K-12100
Siège pliable G K-12101
Rebord pour savon G K-12107
Rebord pour savon D K-12108
37-3/4"
(95,9 cm)
Modèles K-12100, K-12101, K-12107, K-12108
1030529-2-B Français-4 Kohler Co.
Plan de raccordement
Siège G K-12111
Siège D K-12112
9" (22,9 cm)
26" (66 cm)
43" (109,2 cm)
*52" (132,1cm)
2-1/2" (6,4 cm)
37-1/2"
(95,3 cm)
3/4" (2 cm)
2-1/2"
(6,4 cm)
Alimentation
coude
1-1/4"
(3,2 cm)
3-1/4"
(8,3 cm)
37"
(94 cm)
18" (45,7 cm) Max
*84"
(213,4 cm)
19"
(48,3 cm)
Alimentation coude
5" (12,7 cm)
1/2" (1,3 cm)
3/4" (2 cm)
3-1/4" (8,3cm)
*52" (132,1 cm)
43" (109,2 cm)
9"
(22,9 cm)
37-1/2"
(95,3 cm)
2-1/2"
(6,4 cm)
26"
(66 cm)
1-1/4"
(3,2 cm)
18"
(45,7 cm)
Max.
3-1/4"
(8,3 cm)
*84"
(213,4 cm)
37" (94 cm)
K-12113
43" (109,2 cm)
43" (109,2 cm)
Représente la zone de manoeuvre des robinets
Représente une barre coulissante murale de 24" (61 cm).
Représente le dégagement au sol de 36" (91,4 cm) x 43"
(109,2 cm) pour une entrée latérale.
Représente le dégagement au sol de 48" (121,9 cm) x 43"
(109,2 cm) pour une entrée frontale.
36"
(91,4 cm)
48"
(121,9 cm)
Aucun changement des mesures n'est nécessaire si connecté au drain illustré.
(K-9132)
*L'ouverture de la cavité doit être de 52-1/4" (132,7 cm) x 84-1/4" (214 cm).
1/2"
(1,3 cm)
5" (12,7 cm)
Modèles K-12111, K-12112, K-12113
1030529-2-B Français-6 Kohler Co.
Diagrama de instalación
Desagüe a la
izquierda K-12103
Desagüe a la
derecha K-12104
K-12102
34-5/8" (87,9 cm)
60-1/4" (153 cm)
*69-1/4" (175,9 cm)
3/8" (1 cm)
2-1/2" (6,4 cm)
Codo de
suministro
2-1/2"
(6,4 cm)
9-1/4"
(23,5 cm)
37-1/2"
(95,3 cm)
3/4"
(2 cm)
27"
(68,6 cm)
Máx.
*84"
(213,4 cm)
5"
(12,7 cm)
1-5/16"
(3,3 cm)
3-1/4"
(8,3 cm)
Línea central del surtidor
Codo de
suministro
5" (12,7 cm)
37" (94 cm)
7/8" (2,2 cm)
9" (22,9 cm)
56" (142,2 cm)
*64-3/4" (164,5 cm)
3/4" (2 cm)
3" (7,6 cm)
2-7/8" (7,3 cm)
19"
(48,3 cm)
1-5/16"
(3,3 cm)
3"
(7,6 cm)
*84"
(213,4 cm)
20"
(50,8 cm)
4" (10,2 cm)
18"
(45,7 cm)
13"
(33 cm)
1-1/2"
D.E.
4" (10,2 cm)
60" (152,4 cm)
60" (152,4 cm)
Representa el área de control para la grifería
Representa la barra deslizante de montaje a la
pared de 24" (61 cm).
Representa el espacio libre de piso para la
entrada frontal de 48" (121,9 cm) x 60" (152,4 cm).
36"
(91,4 cm)
48"
(121,9 cm)
*La abertura del encajonado debe ser de 69-1/2" (176.5 cm) x
84-1/4" (214 cm).
60" (152,4 cm)
60" (152,4 cm)
No es necesario cambiar las medidas
si se conecta con el desagüe ilustrado.
(K-7161-AF)
Representa el espacio libre
de piso para la entrada
lateral de 36" (91,4 cm) x
60" (152,4 cm).
Representa el espacio libre
de piso para la entrada
frontal de 48" (121,9 cm) x
60" (152,4 cm).
Representa la barra
deslizante de montaje a
la pared de 24" (61 cm).
Representa el área de
control para la grifería.
*La abertura del encajonado debe ser de
65" (165,1 cm) x 84-1/4" (214 cm).
48"
(121,9 cm)
36"
(91,4 cm)
Representa el espacio libre de piso para la
entrada lateral de 36" (91,4 cm) x 60" (152,4 cm).
Modelos K-12102, K-12103, K-12104
1030529-2-B Español-3 Kohler Co.
Diagrama de instalación
36" (91,4 cm)
*45" (114,3 cm)
2-1/2" (6,4 cm) 1/2" (1,3 cm)
37-3/ 4"
(95,9 cm)
2-1/2" (6,4 cm)
18"
(45,7 cm)
Máx
*84"
(213,4 cm)
3-1/4"
(8,3 cm)
1-1/4"
(3,2 cm)
37"
(94 cm)
22-1/2"
(57,2 cm)
3/4"
(1,9 cm)
36" (91,4 cm)
36" (91,4 cm)
Representa el área de control para la grifería
Representa la barra deslizante de montaje a la
pared de 24" (61 cm).
Representa el espacio libre de piso para la entrada
lateral de 36" (91,4 cm) x 36" (91,4 cm).
Representa el espacio libre de piso para la entrada
frontal de 48" (121,9 cm) x 36" (91.4 cm).
36"
(91,4 cm)
48"
(121,9 cm)
*La abertura del encajonado debe ser de 45-1/4" (114.9 cm) x
84-1/4" (214 cm).
9" (22,9 cm)
36" (91,4 cm)
*45" (114,3 cm)
2-1/2" (6,4 cm) 1/2" (1,3 cm)
2-1/2"
(6,4 cm)
Codo de
suministro
*84"
(213,4 cm)
19"
(48,3 cm)
3-1/4"
(8,3 cm)
1-1/4"
(3,2 cm)
37"
(94 cm)
22-1/2"
(57,2 cm)
3/4" (1,9 cm)
18"
(45,7 cm)
Máx
5" (12,7 cm)
Codo de
suministro
5"
(12,7 cm)
9"
(22,9 cm)
Asiento plegable a la derecha K-12100
Asiento plegable a la izquierda K-12101
Reborde para jabón a la izquierda K-12107
Reborde para jabón a la derecha K-12108
37-3/4"
(95,9 cm)
Modelos K-12100, K-12101, K-12107, K-12108
Kohler Co. Español-4 1030529-2-B
Diagrama de instalación
Asiento a la izquierda K-12111
Asiento a la derecha K-12112
9" (22,9 cm)
26" (66 cm)
43" (109,2 cm)
*52" (132,1cm)
2-1/2" (6,4 cm)
37-1/2"
(95,3 cm)
3/4" (2 cm)
2-1/2"
(6,4 cm)
Codo de
suministro
1-1/4"
(3,2 cm)
3-1/4"
(8,3 cm)
37"
(94 cm)
18" (45,7 cm) Máx.
*84"
(213,4 cm)
19"
(48,3 cm)
Codo de suministro
5" (12,7 cm)
1/2" (1,3 cm)
3/4" (2 cm)
3-1/4" (8,3 cm)
*52" (132,1 cm)
43" (109,2 cm)
9"
(22,9 cm)
37-1/2"
(95,3 cm)
2-1/2"
(6,4 cm)
26"
(66 cm)
1-1/4"
(3.2 cm)
18"
(45,7 cm)
Máx
3-1/4"
(8,3 cm)
*84"
(213,4 cm)
37" (94 cm)
K-12113
43" (109.2 cm)
43" (109.2 cm)
Representa el área de control para la grifería
Representa la barra deslizante de montaje a la pared de 24" (61 cm).
Representa el espacio libre de piso para la entrada lateral de
36" (91,4 cm) x 43" (109,2 cm).
Representa el espacio libre de piso para la entrada frontal de
48" (121,9 cm) x 43" (109,2 cm).
36"
(91,4 cm)
48"
(121,9 cm)
No es necesario cambiar las medidas si se conecta con el desagüe ilustrado.
(K-9132)
*La abertura del encajonado debe ser de 52-1/4" (132,7 cm) x 84-1/4" (214 cm).
1/2"
(1,3 cm)
5" (12,7 cm)
Modelos K-12111, K-12112, K-12113
Kohler Co. Español-6 1030529-2-B
USA: 1-800-4-KOHLER
Canada: 1-800-964-5590
México: 001-877-680-1310
kohler.com
©2006 Kohler Co.
1030529-2-B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Kohler 12100-C-0 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI