INTRODUCTION
Forward
Congratulations on your purchase of this thermometer by UEi!
This instrument is a portable, battery operated temperature-
measuring device. It uses thermister probes to provide fast,
accurate measurements with excellent resolution.
Materials Supplied
This package contains:
• TheDT15AorDT20Atemperaturetester
• Animpactresistantrubberboot
• ATT55Athermistorprobe(twoprobesincludedwithDT20A)
• Installedbatteries
• Thisinstructionmanual
SAFETY
Practicing Safety
This instrument is designed for professionals who know the
hazards associated with their trade. While the opportunity to
injure yourself as a direct result of operating this instrument is
nearly non-existent, the equipment you are servicing, as well as
the environment you’re
working in, can be hazardous. These are a few common safety
practices for those working around temperature critical
environments:
• Followthemanufacturer’smaintenanceprocedureswhen
servicing equipment
• PlaceONLYthermistorprobesinthejacks
• Besuretheprobeyouareusingcanwithstandthetempera-
ture extreme it may be exposed to in your service task
• Properlymaintainyourthermometerandcalibrateitregularly
CONTROLS AND INDICATORS
Key:
1. PowerSwitch-Powersinstrumentonandoff
2. Min/Max–Displaysthecapturedminimumandmaximum
values for all parameters.
3. BackLightSwitch-Powersbacklightonandoff
4. HoldSwitch-Freezesscreendata
5. °F/°CModeSelectSwitch-Togglesdisplaydatafrom
degreesCelsiustodegreesFahrenheit.
6. T1-T2Switch(DT20Aonly)-Togglesscreeninformation
betweenT,T2,andT1-T2.
7. ThermistorPorts–1/8”minijackplugsforthethermistor
probesused;T1ontheleftT2ontherightforDT20A
8. LCDDisplay–Displayscreenoffunctionand
data information
9. SecondDisplay(DT20Aonly)–DisplayofT2orT1-T2data
OPERATING INSTRUCTIONS
Functional Description
ThemeterwillmomentarilyflashallLCDsegmentsonthe
display when it is first turned on, emit four quick beeps then
it will go blank for approximately 3 seconds before starting
operation. The instrument will only provide information with
probes plugged in.
TheDT15Ahasasinglescreenofinformationtoviewthe
temperaturein°For°C,recordedminimumormaximum,or
held value.
TheDT20AhasasplitscreentoviewbothT1andT2,or
T1-T2andyourchoiceofeitherT1orT2.Thechoicesfor
formatarethesameaswiththeDT15A.Numerousviewing
combinations are available to ensure you get the information
you need.
• Min/Maxfunctionstartswhenthemeterispoweredon,
and continues to capture values while operating with
probes connected
• TemperaturereadingsareeasilytoggledbetweenFahren-
heit and Celsius
• ThebacklightilluminatestheLCDforviewinginlowlight
areas
• TheHOLDbuttonwillfreezethedisplaydataandsuspend
theMin/Maxfunction
• Thedisplaywillbegintoblinkwhenbatteryvoltageislow.
Note:Ifnoprobesarepluggedin,threedasheswillappearin
the temperature data screens. This will also be recorded as a
Maxuntilthepowerisswitchedoffthenbackon.
This instrument operates and updates silently.
Auto Power Off
Thisinstrumentwillshutoffautomaticallyinapproximately60
minutes.Forrecordingoroperatingoverlongerperiodsof
time you can defeat the auto power off function by holding
down the hold button while turning the unit on. The unit will
start with one solid beep to indicate that auto power off func-
tion is not activated.
Mode Options
Whentheinstrumentisinitiallyturnedon,thePrimaryscreen
displaysT1andtheSecondaryscreendisplaysT2(DT20A).
The following table lists the modes of operation that can be
invoked by pressing the buttons indicated. The table assumes
your instrument has been powered on with temperature
probe(s)installed:
— Continued on reverse —
DT15A/DT20A Controls
DT20Ashown.DT15AdoesnothavedualdisplayorT1-T2button.
DT15A/DT20AMAN9/01
3
4
5
6
8
1
2
7
9
Button Response/Display
On/Off Turnsinstrumenton(Defaultsetting)andoff.
Three beeps emitted at power up.
MIN/MAX PressonceandthedisplayindicatesMIN.
Youarenowabletochangescalestodisplay
minimumindegreesForC,andontheDT20Ayou
areabletocyclethroughT1-T2options.
PressasecondtimetodisplayMAX–Youhave
the same display
Pressagaintoreturntorealtimereadings.
Back Light Pressmomentarilytoactivateorturnoffthe
backlight.
Hold Pressmomentarilytoholdallreadings.Thisalso
stopstherecordingofMin/Maxvalues.
Hold down while turning unit on to disable auto
power off. Confirmed with one solid tone.
˚F / ˚C Pressmomentarilyandtheunittogglesbetween
Fahrenheit(thedefault)andCelsiustemperatures.
The current mode is indicated on the right side of
theLCD.
T1/T2 (DT20A Only) Pressmomentarilytodisplay
T1-T2onthelowerdisplaywithT1onthe
upper display.
PressagaintodisplayT1-T2onthelowerdisplay
withT2ontheupperdisplay.
PressingathirdtimewillreturnthedisplaytoT1
ontheupperdisplayandT2onthelowerdisplay.
MAINTENANCE
Cleaning
Use a damp cloth and mild soap to clean the case of your ther-
mometer.Donotuseharshdetergentsorabrasivesasthese
may mar the finish or damage your unit’s case with an adverse
chemical reaction.
Donotallowmoisturetodirectlycontactthetemperatureprobe
jacks, or enter the instrument’s housing. Remove the instrument
from its boot to ensure moisture is not trapped during cleaning.
Replacing the battery
Replaceyour(3)AAAalkalinebatterieswhen:
• Thedisplaybeginstoblinkonandoff
• Theinstrumentwillnotpoweron
• Useoftheback-lightcausesthedisplaytoblink
Even if the batteries were recently replaced, check their volt-
age level if you get no response from your instrument. Remove
batteries from instruments that you do not plan to use for a
monthormore.Donotleavebatteriesininstrumentsthatmay
be exposed to temperature extremes.
Dispose of batteries in accordance with local land use regula-
tions.
To replace the batteries:
1. Removethetemperatureprobesfromthetopof
the instrument
2. Removetherubberboot,byslidingtheinstrument
out toward the top faceplate cut-out
3.Laytheinstrumentfacedownonaclean,flatsurface.
4. Remove the battery cover by sliding it straight down.
5.Removeandreplacethebatteries,observing
indicated polarity.
Calibration
To ensure your instrument is performing at its peak, send it to
the UEi factory or a qualified instrument calibration facility for
annual calibration.
TROUBLESHOOTING
This instrument contains no user serviceable parts beyond
those listed in this table. In the event your instrument is physi-
cally damaged or does not function properly after taking the
listed action, please return the instrument to UEi following the
warranty and service instructions.
SPECIFICATIONS
Replacement Parts
Batteries:ThreeStandardAAA(NEDA24A,IECLR03)
Alkalinerecommended
TemperatureProbes:ATT55Athermistorprobeimmersionstyle
Optional Accessories
Probes: ATT56AAirprobe
ATT57ASurfaceprobe
AC319SoftCarryingCase
Operating Conditions
32to122°F(0to50°C)at0to85%relativehumidity
(non-condensing)
WARRANTY AND SERVICE
DT15A/DT20A Warranty
Yourthermometeriswarrantedtobefreefromdefectsin
material and workmanship for a period of three years from the
date of
purchase. If, within this warranty period, your thermometer
should become inoperative from such defects, the instrument
will be
repaired or replaced at UEi’s option. This warranty does not
cover batteries, misuse, abuse, alteration, tampering, neglect,
or improper maintenance, or damage resulting from leaking
batteries.Proofofpurchaseisrequiredforwarrantyrepairs.
Service Information
Servicecoveredunderwarrantywillbeprovidedatnocharge.
Instrumentsoutofwarrantywillberepaired,(whenrepairable)
for a service charge. Return the unit postage paid and insured
to:
UEiServiceDepartment
8030SWNimbus•Beaverton,Oregon97008
To receive a free catalog containing our full line of test and
measurementproducts,call(503)644-8723.Visitourfull-feature
web site at ueitest.com.
Autopower
off defeat
Hold function suspends
captureofMIN/MAX
values
Allow5secondsafter
power-on for data to
show up on screen
Instrument turns
off during
recording
Probes
TimeDelay
Dashesappear
in data screen
InsertmissingProbes
Dashesappear
during review
of maximum
recorded value
Followprocedures
outlinedinOperating
Instructions
Hold function
activated
Check for intermittent or
momentarily removed
temperature probe
Replace low batteries
Battery
voltage
Instrument does
not turn on
If I See This
Malfunction
I Should
Check For
Then Take This Corrective
Action
Battery
Polarity
Ensure batteries are
installed as shown in battery
compartment
OpenProbe
Minimumor
Maximumvalue
not captured
Specificationsareforoperatingtemperaturesbetween64and77°F(18to25°C).
Specificationsvalidfor1yearaftercalibration.
Range Resolution Accuracy
-50to-20°F/°C
-19.9to199.9
°F/°C
200to571°F
200to300°C
0.1°
±1%
±1.5°F/°C
GENERAL SPECIFICATIONS
H x W x D
Weight
Thermistor
5.5”x3”x1.25”
.44 lbs.
100k
  • Page 1 1
  • Page 2 2

UEi Test Instruments DT15A User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI