Kenroy Home 50053STST Installation guide

Type
Installation guide
Please
or
s
USE
_
________
_
FL
O
Qu
e
call Kenr
o
s
end ema
i
W
AN
D
_
___________
_
O
OR/
W
e
stions, p
o
y Home
i
l to custo
W
WW.KE
D
CA
R
_
______
_
____
_
W
ALL
F
r
oblems,
m
Custome
r
o
merservi
NROYH
O
R
E G
U
_
___________
_
F
OUN
TA
m
issing p
a
r
Service
a
ce
@
kenr
o
O
ME.C
O
U
IDE
_
___________
A
IN
a
rts?
a
t (904) 6
4
oy
home.
c
O
M
4
2-4340
c
om
MO
D
ASS
E
READ
Read i
n
This fo
u
Make s
u
TOOL
S
Level,
P
PART
S
Wa
Chann
e
(2) W
D
EL:
500
E
MBLY
AND SAV
E
n
structions
a
u
ntain sho
u
u
re all part
s
S
REQUIR
E
P
encil, Phil
l
S
LIST:
Pump (A)
a
ter Diffuse
r
(
e
l & (2) cord
all Spacer P
a
49BRZ/
5
INSTR
U
E
THESE I
a
ll the way
t
u
ld take app
r
s
are firmly
E
D:
l
ips screw
d
(
D)
covers (G)
a
ds (J)
5
0053S
T
U
CTION
N
STRUC
T
t
hrough pri
o
r
oximately
tightened.
r
ive
r
.
Tra
n
B
A bag
o
Pum
p
T
ST
S
T
IONS
o
r to asse
m
15 minutes
n
sformer (B)
B
racket (E)
o
f river stone
p
Connector
(
m
bly.
to assemb
l
s (H)
(
K)
e.
LED Clust
e
L
Water
G
(2) Anchor
s
fo
r
e
r Assembly
(
L
id (F)
G
uiding Pad
r
s & (2) Scre
w
r
cord cove
r
(
C)
(I)
w
s (M)
FOUN
T
1. Re
m
fou
n
2. Re
m
the
3. Att
a
sho
w
4.
Fee
d
tub
e
5.
Pla
c
fou
n
T
AIN ASS
E
m
ove roof f
r
n
tain body.
m
ove plasti
c
top of the
fo
a
ch LED cl
u
w
n.
d
cord fro
m
e
).
c
e roof ont
o
n
tain body.
E
MBLY
r
o
m
the fo
u
c
cover fro
m
fo
untain bo
d
u
ste
r
asse
m
m
LED clus
t
o
the fount
a
u
ntain body
,
m
water dif
f
d
y.
m
bly (C)
b
ra
c
t
er assembl
y
a
in body an
d
,
then remo
v
f
use
r
(D) a
n
cket into m
y
(C) behin
d
d
secure wi
t
v
e water di
f
n
d replace t
h
etal slot on
d
metal bra
c
t
h clips wh
i
f
fuse
r
(D)
fr
h
e water di
f
the back o
f
c
ket (follo
w
ch are atta
c
fr
om top of
t
f
fuse
r
(D)
b
f
fountain b
w
ing the wa
c
hed to bac
k
t
he
b
ack into
o
dy as
t
er
k
of
6.
Pe
e
FOR
W
A1.
L
o
(E
A2.
Ba
s
cons
u
piec
e
fille
d
insta
l
with
insta
l
War
n
dang
e
A3.
Fe
e
li
g
sc
r
A4.
In
s
b
a
e
l paper bac
k
W
ALL MO
U
o
cate desire
d
) to the wa
l
s
ed on yo
u
u
lt local ha
r
e
s to hold
t
d
with wate
r
l
lation of a
n
three scre
w
l
ling.
n
in
g
: Usin
g
erous cond
i
e
d pump (
A
g
ht cord is
r
ew the cap
s
ert pump c
o
sin.
k
ing from t
U
NTED A
P
d
position
o
l
l and mark
u
r specific
r
dware sto
r
t
he weight
r
). Consult
n
chors/scre
w
w
s. The a
n
g
incorrect
i
tion.
A
) power c
o
b
ehind me
to connect
o
o
nnector (
K
h
e wall spa
P
PLICAT
I
o
n the wall.
three mou
n
wall mate
r
e or profes
s
of your fo
u
local hard
w
w
s for wal
l
n
gled part
o
or under
o
rd through
t
al bracket
o
r tightly t
o
K
) into the
h
a
cer pa
d
(J)
I
ONS:
Use a level
n
ting holes.
r
ial (wallb
o
s
ional to d
e
u
ntain (N
O
w
are store
o
l
bracket (
E
o
f the wall
specified
f
the hole in
(Ref: Ste
p
o
gethe
r
.
h
ole of pu
m
and apply t
to draw a l
o
ard, sheet
e
termine th
e
O
TE: This
f
o
r professi
o
E
). Then se
c
bracket (
E
f
asteners c
o
back of th
e
p
#4), then
m
p (A), then
o
back of t
h
i
ne on the
w
rock, pla
s
e
appropria
t
f
ountain is
o
nal for pro
p
ure the bra
c
E
) should b
e
o
uld result
e
fountain b
join the li
g
place the p
u
h
e basin as
s
w
all, place
b
s
ter, concr
e
t
e anchor t
y
about 40 l
b
o
per instruc
t
c
ket (E) to
e on the t
o
in an uns
b
ody. Make
g
ht connec
t
ump (A) in
t
s
hown.
b
racket
e
te etc.),
y
pe for 3
b
s. after
t
ions for
the wall
o
p when
table or
sure the
t
ors and
t
o the
A5. Al
i
se
c
fo
u
A6.
T
o
(
G
dr
y
w
a
th
e
A7. Pl
a
ch
i
gn bracket
c
urely on
b
u
ntain is o
n
o
install the
G
) on the w
a
y
wall, mak
e
a
ll stud whi
l
e
anchor. T
h
a
ce power c
o
annel (G).
(E) on the
b
racket (E)
n
the top of
t
anchors (
M
a
ll and mar
k
e
sure the f
l
l
e installin
g
h
en secure
t
o
rd inside
c
wall with
b
attached
t
t
he wall
b
r
a
M
) for the co
k
two moun
t
l
at side of t
h
g
the ancho
r
t
he cord co
v
c
ord cover
c
b
racket on
t
o the wall
,
a
cket (E).
o
rd cove
r
c
h
t
ing holes.
G
h
e anchor i
s
r
s (M), ple
a
v
er channel
c
hannel (G)
the back o
f
,
make sur
h
annel (G),
p
G
ently tap
o
s
flush with
a
se use the
m
to the wall
and press
c
f
fountain,
h
e
the
b
rac
k
p
lace the c
o
o
r press the
the wall. I
f
m
ounting s
c
with two s
c
c
ord cover
s
h
ang fount
a
k
et on the
o
rd cover c
h
tip into th
e
f
you encou
n
c
rews (M)
w
c
rews (M).
s
ecurely on
t
a
in body
back of
h
annel
e
n
ter a
w
ithout
t
o the
FOR F
B1. Fe
e
lig
h
scr
e
B2. Ins
e
b
as
i
B3. Pla
7. Fill t
h
(The
(Dis
t
8. Test
guid
i
foun
t
LOO
R
A
P
e
d pump (A
h
t cord is
be
e
w the cap
t
e
rt pump c
o
i
n.
ce the foun
t
h
e basin w
i
basin hold
s
t
illed water
the water r
u
i
ng pa
d
(I)
t
t
ain on.
P
PLICATI
O
) power co
r
e
hind the m
e
t
o connect t
h
o
nnecto
r
(
K
t
ain body o
n
i
th enough
w
s
1.7 gallon
is recomm
e
u
nning and
t
o brush th
e
O
NS:
r
d through
t
e
tal bracket
h
e parts tig
h
K
) into the h
o
n
to the des
i
w
ater to co
m
s of water.)
e
nded to re
d
adjust the
w
e
fountain f
a
t
he hole in
b
t
(Ref: Step
h
tly togeth
e
o
le of pum
p
i
red flat flo
o
m
pletely su
b
)
d
uce miner
a
w
ater valve
a
ce to provi
b
ack of the
#4), then j
o
er
.
p
(A), then
p
o
r and aga
b
merse pu
m
a
l deposits
a
on the pu
m
de a better
w
f
ountain b
o
o
in the ligh
t
p
lace the p
u
inst the
w
m
p (A).
a
nd bacteri
a
m
p (A) if ne
e
w
ater flow
w
o
dy. Make s
t
connector
s
u
mp (A) in
t
w
all.
a
buil
d
-up.)
e
ded. Use t
h
when first
t
ure the
s
and
t
o the
h
e water
t
urning
9. Plac
e
The
n
10. Joi
n
par
t
11. Plu
g
Troubl
e
1. If yo
u
inserted
2. Next
c
3. If yo
u
back on
4. If the
(904) 6
4
to the st
o
Splash
i
Splashi
n
Impor
t
Water:
To redu
c
Impor
t
Warni
n
* Once
a
is espec
i
** This
(GFCI).
should i
n
manner,
e
lid (F) int
o
n
place dec
o
n
the conne
c
t
s tightly to
g
g
power co
r
e
shootin
g:
u
r fountain
d
into the wall
c
heck to ma
k
u
reconnecte
d
to help relea
s
fountain still
4
2-4340 or s
e
o
re where yo
u
i
n
g
disclai
m
n
g may occur
t
ant pump
c
e mineral de
p
t
ant safet
y
ng
:
a
week inspe
c
i
ally importa
n
unit must b
e
The GFCI s
h
n
terrupt pow
e
the GFCI is
d
o
basin to c
o
o
rative rive
r
c
tor from p
u
g
ether.
r
d into soc
k
:
d
oes not wo
r
outlet.
k
e sure the ou
d
the pump,
s
s
e air in the l
i
does not wo
r
e
nd email to
c
u
purchased
i
m
er:
when founta
informati
o
p
osits and b
a
instructio
n
c
t fountain,
fl
n
t for humid
e
e
connected
t
h
ould be tes
t
e
r. Push the
r
d
efective.
o
ver the
b
a
s
r
stones (H)
u
mp (A) to
k
et and you
r
r
k, check pl
u
t
let is power
e
s
ometimes t
h
i
ne.
r
k or you are
c
ustomerse
r
i
t, call us for
in is initially
o
n:
Pump m
u
a
cteria build
u
n
s:
This foun
fl
oor and adj
a
e
nvironment
s
t
o a supply
c
t
ed on a rout
i
r
eset button.
P
s
in, make s
u
into the li
d
transforme
r
r
new fount
a
u
g at the so
c
e
d.
h
e water wo
u
unhappy wi
t
r
vice@kenro
a quick reso
l
turned on. P
r
u
st be fully s
u
u
p the use of
n
tain is rated
f
a
cent wall fo
r
s
.
c
ircuit that is
i
ne basis. To
P
ower shoul
d
u
re the ope
n
d
(F).
r
(B) and s
c
a
in is read
y
c
ket. Make s
u
u
ld not flow,
p
t
h anything a
b
yhome.com.
ution.
r
otect surrou
n
u
bmersed in
w
distilled wat
e
f
or indoor an
d
r
moisture b
u
protected b
y
test the GF
C
d
be restored.
n
side facin
g
c
rew the ca
p
for use!
u
re the plug
p
lease turn
o
b
out this pro
d
Please do n
o
n
ding surfac
e
w
ater while o
p
e
r is recomm
e
d
outdoor us
e
i
ld-up and cl
e
y
a ground f
a
C
I, push the
t
If the GFCI
g up.
p
to connec
t
is fully and
o
ff the powe
r
d
uct, call us
a
o
t return yo
u
e
s as needed.
perating.
e
nded.
e
.
ean as neces
s
fa
ult circuit i
n
t
est button.
T
fails to oper
a
t
the
properly
r
and turn
a
t
u
r product
s
ary. This
n
terrupter
T
he GFCI
a
te in this
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Kenroy Home 50053STST Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI