CTI 8 Manual V15.2 July 2010.doc Page 5/20
Technical Specification
Power Requirements 9Vdc 500mA
Inputs 2 Wire RS485, 2 Wire RS422 Simplex and 4 Wire Full Duplex (input
protocol switch selectable)
Maximum cable distance: Belden 8723 = 1200m
Outputs 8 x BBV Coax Telemetry
Maximum Cable Distance RG59 = 250m
CT125 = 500m
Facilities LEDs as power & data indication
Boxed Dimensions Supplied in 19” 1 U rack mountable case
Length 425mm
Depth 110mm
Height 43mm
Installation The unit is designed to either be fitted into a 19” rack or wall mounted via
the fixing brackets supplied
CTI/8 Manual & Software Version History
Version 15.2 June 2010 -1. Change to the Test mode page
Version 15A June 2010 -1. Change to the Sensormatic commands on page 9
Version 15 11 December 2009 -1. Added Test feature. Pan Left & Right via dipswitches
Version 1 8 May 2008 -1.
CTI/8 Released
Version 13 15 October 2007 -1. Bug fix for address 27 in Dennard RS485 Protocol
Version 12 10 October 2007 -1. Bug fix for address 2 & 3 in Dennard RS485 Protocol
Version 11 3 September 2007 -1. Updated Support of VCL Telemetry from Maxcom 8 Matrix
-2. Manual Update
Version 10 15 August 2007 -1. Bug fix of VCL Telemetry from Maxcom 8 Matrix
Version 9 10 July 2007 -1. Updated Support of VCL Telemetry from Maxcom 8 Matrix
Version 8 17 March 2007 -1. Updated support of Hash Command release time
-2. Manual update
Version 7 13 February 2007 -1. Added continuous sending of telemetry for legacy coax receivers
Version 6 8 January 2007 - 1. Molynx Protocol Speed table recalibration
Version 5 11 December 2006 - 1. Bug fix for Accumulative Delays in Pelco P & D and Dennard RS485 Routines
- 2. Updated watchdog routine
- 3. Added support for Sensormatic RS422 Protocol
- 4. Added support for Molynx RS485 Protocol
- 5. Added support for Vicon RS485 Protocol variable Baud Rate
Version 4 18 November 2005 - 1. Added support for Pelco P/D Protocol variable Baud Rate & Parity settings
- 2. Added support for Pelco P DM Auxiliary outputs
Version 3 27 June 2005 - 1. Added support for Dennard 2050 Protocol
Version 2 25 May 2005 - 1. Added support for Philips RS485 Protocol
Version 1 11 November 2005 - 1. CTI/16 Released
Support of BBV, Dennard, Philips, Pelco P & D and VCL RS485 input protocols converting to
BBV Coax output protocol