GROHE 3264200A Installation guide

Category
Sanitary ware
Type
Installation guide

GROHE 3264200A is a single-lever faucet that can be used with pressurized storage heaters, thermally controlled instantaneous heaters, and hydraulically controlled instantaneous heaters. Before using the device, the user should remember to open angle stops and check the faucet for correct function.

The faucet is equipped with a flow rate limiter and a temperature limiter, so the user can customize the water flow and temperature to their liking. It also has a non-reversible cartridge, which means that it cannot be installed upside down.

To install the faucet, the user will need to flush the piping system thoroughly before and after installation. The faucet should be mounted on the basin, and the supply hoses should be connected to the angle stops. The hot water supply should be connected on the left side, and the cold water supply should be connected on the right side. Finally, the user should install the pop-up drain and ensure that the flange is sealed.

GROHE 3264200A is a single-lever faucet that can be used with pressurized storage heaters, thermally controlled instantaneous heaters, and hydraulically controlled instantaneous heaters. Before using the device, the user should remember to open angle stops and check the faucet for correct function.

The faucet is equipped with a flow rate limiter and a temperature limiter, so the user can customize the water flow and temperature to their liking. It also has a non-reversible cartridge, which means that it cannot be installed upside down.

To install the faucet, the user will need to flush the piping system thoroughly before and after installation. The faucet should be mounted on the basin, and the supply hoses should be connected to the angle stops. The hot water supply should be connected on the left side, and the cold water supply should be connected on the right side. Finally, the user should install the pop-up drain and ensure that the flange is sealed.

D
.....1
NL
.....6
PL
.....11
P
.....16
BG
.....21
CN
.....26
GB
.....2
S
.....7
UAE
.....12
TR
.....17
EST
.....22
UA
.....27
F
.....3
DK
.....8
GR
.....13
SK
.....18
LV
.....23
RUS
.....28
E
.....4
N
.....9
CZ
.....14
SLO
.....19
LT
.....24
I
.....5
FIN
...10
H
.....15
HR
.....20
RO
.....25
DESIGN + ENGINEERING
GROHE GERMANY
www.grohe.com
32 642
32 643
EUROSMART
99.0243.031/ÄM 230640/09.14
D
.....1
NL
.....2
PL
.....4
P
.....6
BG
.....7
CN
.....9
GB
.....1
S
.....3
UAE
.....4
TR
.....6
EST
.....8
UA
.....9
F
.....1
DK
.....3
GR
.....5
SK
.....6
LV
.....8
RUS
...10
E
.....2
N
.....3
CZ
.....5
SLO
.....7
LT
.....8
I
.....2
FIN
.....4
H
.....5
HR
.....7
RO
.....9
English .....1
Français .....2
Español .....3
I
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Entregue estas instrucciones al usario final de la grifería!
Please pass these instructions on to the end user of the fitting!
32 642
32 643
1
English
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
Max. flow 5.4 L/min or 1.5 gpm/60 psi
Flow pressure
- min. 7.25 psi
- recommended 14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure
reducing valve
Max. operating pressure 145 psi
Test pressure 232 psi
Temperature
- max. (hot water inlet) 158 °F
- thermal desinfection possible 194 °F
Water connection hot - LH
cold - RH
Non reversible cartridge
Note
Major pressure differences between hot and cold
water supply should be avoided.
Installation
Flush piping system prior and after installation of
faucet thoroughly!
Mount faucet on basin
See dimensional drawing on fold-out page I.
For installation, see fold-out page III, Fig. [1].
Lift rod (A) must be inserted into the mixer body during
installation.
Connect faucet
For this purpose the supply hoses must be connected
to the angle stops (or other supply points), see Figs. [3]
and [4].
The hot water supply should be connected on the left,
the cold water supply on the right side.
Avoid cross connection. The cartridge is not
reversible.
Fit pop-up drain (28 957), see Fig. [2] and fold-out
page II, ensure that flange of pop-up drain is sealed.
Open angle stops and check faucet for correct
function, see fold-out page III, Fig. [5].
Lift lever = open (water flow)
Press lever down = closed (off)
Move lever to right = cold water
Move lever to left = hot water
Check connections for leakage.
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
For commissioning see “replacing the cartridge”
point 1 to 3, Figs. [6] and [7].
Temperature limiter
On delivery, the temperature limiter (fitted as standard)
is inoperative.
For commissioning see “replacing the cartridge”
point 1 to 3, Fig. [6].
Remove temperature limiter (G) and depending on the
maximum temperature required, turn clockwise and
refit.
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off the hot and cold water supply!
I. Replacing the cartridge, see Fig. [6].
1.Lever out plug (D).
2.Remove set screw (C) using a 3mm socket wrench
and pull off lever (B).
3.Pull off cap (E).
4.Turn out screwing (F) with key 32mm.
5.Change complete cartridge (H).
Assemble in reverse order.
Observe the correct installation position!
Screw in and tighten screwing (F).
II. Flow control, see fold-out page II.
Unscrew and clean flow regulator (48 159).
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.
2014/03/21
www.grohe.com
D
&
+49 571 3989 333
impressum@grohe.de
A
&
+43 1 68060
info-at@grohe.com
AUS
Argent Sydney
&
+(02) 8394 5800
Argent Melbourne
&
+(03) 9682 1231
B
&
+32 16 230660
info.be@grohe.com
BG
&
+359 2 9719959
grohe-bulgaria@grohe.com
CAU
&
+99 412 497 09 74
CDN
&
+1 888 6447643
CH
&
+41 448777300
CN
&
+86 21 63758878
CY
&
+357 22 465200
CZ
&
+420 277 004 190
grohe-cz@grohe.com
DK
&
+45 44 656800
E
&
+34 93 3368850
EST
&
+372 6616354
F
&
+33 1 49972900
marketing-fr@grohe.com
FIN
&
+358 10 8201100
teknocalor@teknocalor.fi
GB
&
+44 871 200 3414
GR
&
+30 210 2712908
nsapountzis@ath.forthnet.gr
H
&
+36 1 2388045
HK
&
+852 2969 7067
I
&
+39 2 959401
IND
&
+91 124 4933000
IS
&
+354 515 4000
J
&
+81 3 32989730
KZ
&
+7 727 311 07 39
LT
&
+372 6616354
LV
&
+372 6616354
grohe@grohe.ee
MAL
&
+1 800 80 6570
info-singapore@grohe.com
N
&
+47 22 072070
grohe@grohe.no
NL
&
+31 79 3680133
NZ
&
+09/373 4324
P
&
+351 234 529620
PL
&
+48 22 5432640
RI
&
+62 21 2358 4751
info-singapore@grohe.com
RO
&
+40 21 2125050
info-ro@grohe.com
ROK
&
+82 2 559 0790
info-singapore@grohe.com
RP
&
+63 2 8041617
RUS
&
+7 495 9819510
info@grohe.ru
S
&
+46 771 141314
SGP
&
+65 6 7385585
info-singapore@grohe.com
&
+420 277 004 190
&
+66 2610 3685
info-singapore@grohe.com
&
+90 216 441 23 70
&
+38 44 5375273
info-ua@grohe.com
&
+1 800 4447643
us-customerservice@grohe.com
&
+84 8 5413 6840
info-singapore@grohe.com
&
+385 1 2911470
Eastern Mediterranean,
Middle East - Africa
Area Sales Office:
&
+357 22 465200
&
+971 4 3318070
grohedubai@grome.com
Far East Area Sales Office:
&
+65 6311 3600
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

GROHE 3264200A Installation guide

Category
Sanitary ware
Type
Installation guide

GROHE 3264200A is a single-lever faucet that can be used with pressurized storage heaters, thermally controlled instantaneous heaters, and hydraulically controlled instantaneous heaters. Before using the device, the user should remember to open angle stops and check the faucet for correct function.

The faucet is equipped with a flow rate limiter and a temperature limiter, so the user can customize the water flow and temperature to their liking. It also has a non-reversible cartridge, which means that it cannot be installed upside down.

To install the faucet, the user will need to flush the piping system thoroughly before and after installation. The faucet should be mounted on the basin, and the supply hoses should be connected to the angle stops. The hot water supply should be connected on the left side, and the cold water supply should be connected on the right side. Finally, the user should install the pop-up drain and ensure that the flange is sealed.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI