Symmons SLS-6712-MP-1.0 Installation guide

Category
Sanitary ware
Type
Installation guide
Identity
Model Numbers
Single Handle Lavatory Faucet
Operation & Maintenance Manual
SLS-6710-1.5, SLS-6712-1.5
Single handle lavatory faucet features single hole mount,
ceramic cartridge with temperature limit stop, 20" braided
hose connections, 50/50 pop-up drain assembly and
standard 1.5 gpm (5.7 L/min) ow restrictor. Faucet
constructed from brass, plated in standard
polished chrome nish.
Specification
Modifications
Note: Append appropriate -sufx to model number.
SLS-6710-1.5
Single Handle Lavatory Faucet
SLS-6712-1.5
Single Handle Lavatory Faucet with lift rod and
50/50 pop-up drain assembly
Dimensions
Measurements
A Ø 2", 51 mm
B 5-5/16", 135 mm
C
Deck Thickness Ref.
Min. 1-3/4", 44 mm
Max. 2-1/4", 57 mm
D
Hole Size
Ø 1-1/2", 38 mm
E 20", 508 mm
F 6-1/2", 165 mm
G 3", 76 mm
H
Min. 2", 51 mm
I
5-3/8", 137 mm
Note: Dimensions subject to change without notice.
-0.5 0.5 gpm (1.9 L/min) flow restrictor
-1.0 1.0 gpm (3.8 L/min) flow restrictor
-Delete
Suffix 1.5
2.2 gpm (8.3 L/min) flow restrictor
-DP4 4" deck plate for single hole mount faucets
-MP Metal pop-up drain in place of standard
-STN Satin Nickel finish
-VP Vandal resistant aerator
HH
AA
BB
EE
CC
DD
GG
II
FF
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Compliance
-ASME A112.18.1/CSA B125.1
-NSF/ANSI 61.9, NSF/ANSI 372
-WaterSense 1.5 gpm (5.7 L/min)
For California Residents
WARNING: This product contains chemicals known to
the State of California to cause cancer, birth defects, or
other reproductive harm.
Certied by
CSA Group
2
*Note: Append -STN to part number for Satin Nickel
nish.
Replacement Parts
Item Description Part Number
A
B
C
Handle Kit LN-01449*
F Lift Rod RL-280*
G
H
Temperature Limit Stop
Cartridge
RL-276
J
Aerator Kit (2.2)
Aerator Kit (1.5)
Aerator Kit (1.0)
Laminar Flow Kit (2.2)
Laminar Flow Kit (1.5)
Laminar Flow Kit (1.0)
Laminar Flow Kit (0.5)
LN-15*
FLR-110-1.5*
FLR-110-1.0*
RL-019-2.2*
RL-019-1.5*
RL-019-1.0*
RL-019*
N
O
P
Mounting Hardware RL-238
Q
50/50 Pop-Up
Drain Assembly
RL-223*
Tools Required
Adjustable Wrench
Allen Wrench
3/32"
Plumber Putty
Plumber Tape
PLUMBER
PUTTY
Parts Breakdown
A
Q
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q1
Q2
Q3
Q5
Q6
Q7
Q4
Q8
Q9
Q11
Q10
Q12
Q14
Q13
3
Installation
M
L
K
2) Place rubber washer (N), metal
washer (O) onto threaded rods (L).
Secure with nuts (P).
L
N
O
P
2
1
1) Insert supply lines (M) and threaded
rods (L) through escutcheon (K)
and sink hole.
1
3
2
Q1
Q2
Q7
PIVOT
1
Q7
Q8
Q9
Q11
Q10
If replacing an older faucet
ensure water supply is turned
OFF before removing, then
turn faucet control valve ON
to relieve water pressure.
3) Seat ange (Q2) into sink. Install
gasket (Q4), washer (Q5) and nut
(Q6) onto ange from below sink,
but do not secure nut. Screw on
tail piece (Q7) and hand tighten.
2
2
3
1
Q2
Q3
Q5
Q6
Q7
Q4
OPTIONAL
PLUMBER
PUTTY
4) Turn tail piece (Q7) and ange (Q2)
so pivot is facing toward faucet.
Pull assembly down into drain hole.
Secure hardware from below sink.
Install stopper (Q1) in the remov-
able or non-removable position.
5) Attach inner washer (Q8), pivot rod
(Q9) and outer washer (Q10) to tail-
piece (Q7). Hand tighten nut (Q11)
to secure pivot rod (Q9).
6) Connect lift rod (F) to clevis strap (Q13)
and secure with thumb screw (Q14).
Insert pivot rod (Q9) through spring
clip (Q12) and clevis strap (Q13).
Secure with spring clip (Q12) and
adjust linkage if necessary.
3
1
F
Q13
Q9
4
4
Q12
2
Q14
Note: Hoses removed for clarity.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2016 Symmons Industries, Inc. symmons.com [email protected] ZV-3204 REV 0 040416
Installation
7) Attach supply lines (M) to shut-off
valves and hand tighten. Using a
wrench, nish with one-half turn.
DO NOT overtighten.
1
1
M
2
8) Remove ow restrictor (J) and ush
supply lines free of debris. Check
for leaks.
2
2
J
9) Optional: Adjust limit stop washer
to limit handle turn to the hot
position if desirable.
Note: Counterclockwise to lower
temperature, clockwise to increase
temperature.
1
3
2
+
_
Maintenance
1) Turn off water supply. Remove plug
button (B). Loosen and remove the
handle set screw (C), handle (A),
collar (D) and nut (E).
4
3
1
2
5
A
B
C
D
E
2) Remove cartridge (H) and inspect
for debris. Replace cartridge if
necessary.
3) Install cartridge following steps
1 & 2 in reverse.
H
Problem Cause Solution
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Troubleshooting Chart
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Symmons SLS-6712-MP-1.0 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI