SMB XDI 8 D User Instructions

Type
User Instructions
Manufacturer : Agent :
SBM
3 cottages de la Norge
21490 CLENAY
FRANCE
http : //www.sbm-international.net
1
GAS INFRARED HEATERS
1312
XDIXDI D HEATERS
USER INSTRUCTIONS
Nr 05000371/7
1. PRODUCT SPECIFICATION
2. SAFETY RECOMMENDATIONS
3. IGNITION
4. SHUT-OFF
5. MAINTENANCE
6. CHANGING THE GAS USED
TR
IE
GB
2
1. PRODUCT SPECIFICATION :
Refer to the rating plate sticked on the side of the heater.
(see example below).
MODEL XDI 8
XDI 8 D
XDI 10
XDI 10 D
XDI 12
XDI 12 D
XDI 16
XDI 16 D
P.I.N. 1312 CQ 6090
Class NOx 4
Weight (kg) 5.75 6.25 7.00 8.25
Net calorific value Qn
(kW) Hi 3.30 3.80 5.10 6.80
Combustion air G20
(m3/h) G31
3.40
3.10
3.90
3.60
5.30
4.80
7.00
6.30
Required air renewal rate
(m3/h) 33 38 51 68
Consumption G20
(m3/h) 0.350 0.400 0.540 0.715
Consumption G31
(kg/h) 0.260 0.300 0.400 0.530
3
2. SAFETY RECOMMENDATIONS :
THESE HEATERS MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED INSTALLER
IN ACCORDANCE WITH THE CURRENTLY APPLICABLE SAFETY REGULATIONS AND
WITH THE SBM INSTALLER INSTRUCTIONS Nr. 05000372.
TO AVOID ABNORMAL MECHANICAL CONSTRAINTS ON THE RADIANT, IT IS
RECOMMENDED THAT IT BE CONNECTED TO THE GAS MAINS BY A FLEXIBLE TUBE.
TO BE INSTALLED IN WELL-VENTILATED PREMISES.
THE XDI-D HEATERS MUST BE INSTALLED ONLY IN A TERRACE (OUTSIDE) AND THE
TERRACE MUST BE SUFFICIENTLY OPEN.
2.1 HEATER INCLINATION
2.2 MINIMUM SAFETY CLEARANCES (INFLAMMABLE MATERIALS: max=70°C)
15°, 25° or 35°
1 m mini.
0.25 m
mini.
0.20 m
mini.
XDI 8 (D) : 0.70 m
XDI 10 (D) : 0.80 m
XDI 12 (D) : 1.00 m
XDI 16 (D) : 1.20 m
HEATED AREA
HEATED AREA
0.20m
4
3. START-UP :
Open the main gas valve.
Switch the power on.
Start the heater ignition cycle by positionning the speed switch on"MAXI"
and the ignition switch on "I / ON".
If the flame is not lit after 30 seconds, the heater goes to safety state.
The sequence of ignition can begin again only after switching the power off.
After 5 seconds, switch the power on.
The heater is on as long as : power supply is on and the valves
are opened.
If the flame is still not lit or goes out, close the main gas valve, switch
the power off and call your SBM installer.
After 5 minutes heating on the maxi speed, it is possible to put the speed
switch on "MINI".
Always light the heaters on the "MAXI" speed.
Do not put the speed "MINI" before 5 minutes heating on
the "MAXI" speed.
4. SHUT OFF :
Put the ignition switch on "O / OFF".
Close the main gas valve.
5. MAINTENANCE :
To be performed once a year by your SBM installer, according to the
SBM INSTALLER INSTRUCTIONS Nr. 05000372.
6. CHANGING THE GAS USED :
For any change in the type of gas used, please contact your SBM
installer.
TO BE DISPLAYED
NEXT TO THE CONTROL SWITCHES
Manufacturer :
SBM
3 cottages de la Norge 21490 CLENAY - FRANCE 1312
Agent :
Installer's stamp :
GAS INFRARED HEATERS
XDIXDI D HEATERS
USER GUIDE
Nr 05000371/7
( TO BE DISPLAYED NEXT TO THE CONTROL SWITCHES )
START-UP :
Open the main gas valve.
Switch the power on.
Start the heater ignition cycle by positionning the speed switch on "MAXI"
and the ignition switch on "I / ON".
If the flame is not lit after 30 seconds, the heater goes to safety state.
The sequence of ignition can begin again only after switching the power off.
After 5 seconds, switch the power on.
The heater is on as long as : power supply is on and the valves are opened.
If the flame is still not lit or goes out, close the main gas valve, switch
the power off and call your SBM installer.
After 5 minutes heating on the maxi speed, it is possible to put the speed
switch on "MINI".
Always light the heaters on the "MAXI" speed. Do not put the speed
"MINI" before 5 minutes heating on the "MAXI" speed.
SHUT OFF :
Put the ignition switch on "O / OFF".
Close the main gas valve.
MAINTENANCE :
To be performed once a year by your SBM installer, according to the
SBM INSTALLER INSTRUCTIONS Nr. 05000372.
  • Page 1 1