De Dietrich Quick user guide DIEMATIC Evolution User guide

Type
User guide
7717732 - v03 - 03/09/2019
1
51,2°C
29,4°C
Not set
None o OFF
OK
I
I
6,7°C
Quick user guide
Icons for accessing menus,
zones and parameters
Information on the selected
icon
Back key
Menu key
Rotary
selection
button
Conrm
button
Status indicator LED
- continuous green = normal operation
- ashing green = warning
- continuous red = shutdown
- ashing red = lockout
Standby screen
To deactivate the standby screen, press , or .
The screen goes into standby if no key is pressed for ve minutes.
Description of the interface
Activate a dierent timer programme
Scheduling
Schedule 2
Schedule 3
Schedule 1
>>>
Zone
I have run out of hot water
Boost the production of domestic hot water for a few hours
Hot water boost
02
00
00
Hour
Minute
03
01
01
>>>
I am away for a few days
Reduce the room temperature and the domestic hot water temperature during this
period of absence
End date holiday
Wished room temperature during holida...
03/01/2019 17:00
Start date holiday
20/12/2018 09:00
Reset
10.0°C
>>>
I want to stop the heating and activate cooling*
Activate Summer mode. Domestic hot water production is maintained.
Force summer mode
Off
Off
On
>>>
* only when a heat pump is used
2 7717732 - v03 - 03/09/2019
51,2°C
Not set
NoneoOFF
OK
I
CIRCA0
CH1
Room temp
--
A2: Comfort
20.0 °C
PH1
until: Tue. 22:00
6,7°C
Description of the selected
icon
Operating mode active in the selected zone:
Timer programme
- PH1 = programme 1
- PH2 = programme 2
- PH3 = programme 3
- PH4 = cooling programme
Manual mode
Temporary override
Holiday mode
Frost protection mode
Heating zones
In your installation, a heating zone is represented by one of the following icons:
Selected icon
I am too hot or too cold
Alter the temperatures used in the timer programmes
Set activity temperatures
>>>
Zone
19.5
20.5
19.0
20.0 °C
Reduced
Away
Morning
Evening
16.0°C
6.0°C
21.0°C
22.0°C
Comfort
20.0°C
Alter the room temperature for a few hours
Short temperature change
03
01
00
Hour
Minute
04
02
01
20.0 °C
19.5
20.5
19.0
>>>
Zone
I have changed my routine
Alter the timer programme (for heating, domestic hot water or cooling)
Tuesday WednesdayMonday
23:00 Reduced 19.0°C
6:00 Comfort 22.0°C
Add time and Activity
Copy to other day
Set Activity Temperatures
Zone configuration
Heating Schedule
Schedule 2
Schedule 3
Schedule 1
...
>>>
Zone
  • Page 1 1