DIRECT VENT ZERO CLEARANCE GAS
FIREPLACE HEATER SERIES:
MILLIVOLT (MV)
DVCC(32,36,42)BP32(N,P)-1
INTERMITTENT PILOT (IP)
DVCC(32,36,42)BP72(N,P)-1
UL FILE NO. MH30033
INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
GAS-FIRED
Carton Contents
Accessory Sheet Registration Card
Hardware Pack Receptacle
Junction Box Cover
This appliance may be installed in
an aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by state or local
codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other

WARNING: If not installed, operated and maintained
in accordance with the manufacturers instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
 -
mable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
 
 
not use any phone in your building.
 
     
from a neighbors phone. Follow the
gas suppliers instructions.
 

Installation and service must be per-
     
agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Note: Barrier required, but may be sold separately.
HOT GLASS
DO NOT TOUCH
NEVER
WILL
CAUSE BURNS.
GLASS
UNTIL COOLED.
ALLOW CHILDREN
TO TOUCH GLASS.
WARNING
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
32262-10-0415Page 2
TABLE OF CONTENTS
SECTION PAGE
IMPORTANT SAFETY INFORMATION ......................................................................................... 3
SAFETY INFORMATION FOR USERS OF LP GAS ..................................................................... 4
REQUIREMENTS FOR MASSACHUSETTS ................................................................................ 5
INTRODUCTION ........................................................................................................................... 6
SPECIFICATIONS ......................................................................................................................... 7
ACCESSORIES ............................................................................................................................. 8
FBB10 BLOWER KIT INSTALLATION (OPTIONAL) .............................................................. 9 - 11
VENT SYSTEM IDENTIFICATION .............................................................................................. 12
SPECIAL VENT SYSTEMS ......................................................................................................... 12
FIREPLACE DIMENSIONS ......................................................................................................... 13
CLEARANCES ............................................................................................................................ 14
LOCATING FIREPLACE .............................................................................................................. 15
GAS SUPPLY .............................................................................................................................. 16
INSTALLATION ..................................................................................................................... 17 - 20
VENTING FIREPLACE - TOP ..............................................................................................21 - 24
EXAMPLES - TOP VENT RUN .................................................................................................... 25
VENT TERMINAL CLEARANCES ............................................................................................... 26
FRAMING AND FINISHING ..................................................................................................27 - 28
TERMINATION CLEARANCES ................................................................................................... 29
VERTICAL TERMINATION ................................................................................................... 30 - 31
DVVK-4F FLEX VENT INSTRUCTIONS ..............................................................................32 - 33
MILLIVOLT OPERATING INSTRUCTIONS (BP3 SERIES) .................................................34 - 35
MILLIVOLT STANDING PILOT WIRING DIAGRAM (BP3 SERIES) ........................................... 36
MILLIVOLT STANDING PILOT LIGHTING INSTRUCTIONS (BP3 SERIES) .............................. 37
MILLIVOLT STANDING PILOT TROUBLESHOOTING (BP3 SERIES) ....................................... 38
IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS (BP7 SERIES) .............................. 39
IPI ELECTRONIC SYSTEM WIRING DIAGRAM (BP7 SERIES) ................................................ 40
INTERMITTENT PILOT LIGHTING INSTRUCTIONS (BP7 SERIES) ......................................... 41
INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING (BP7 SERIES) ........42 - 44
MAINTENANCE AND SERVICE ................................................................................................. 45
MILLIVOLT PARTS LIST - DVCC(32,36,42)BP3 ......................................................................... 46
MILLIVOLT PARTS VIEW - DVCC(32,36,42)BP3 ....................................................................... 47
IP PARTS LIST - DVCC(32,36,42)BP7 ........................................................................................ 48
IP PARTS VIEW - DVCC(32,36,42)BP7 ...................................................................................... 49
MASTER PARTS DISTRIBUTOR LIST ....................................................................................... 50
HOW TO ORDER REPAIR PARTS ............................................................................................. 50
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS ...................................................... 51
WARRANTY ................................................................................................................................52
32262-10-0415 Page 3
DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED
Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.
 

draperies.
 
the appliance must be replaced prior to operating

service person.
 
 
 Installation and repair should be done by a
QUALIFIED SERVICE PERSON. The appliance
should be inspected before use and at least annually
by a qualified service person. More frequent
cleaning may be required due to excessive lint from
carpeting, bedding materials, etc. It is imperative
that control compartments, burners and circulating
air passageways of the appliance be kept clean.
 

      
codes and the requirements of the gas supplier.
  keep the appliance area clear and free from

vapors and liquids.
  examine venting system periodically and replace
damaged parts.
 make a periodic visual check of pilot and burners.
Clean and replace damaged parts.
        
tempered glass. If the glass is cracked or damaged in
any way, it should be replaced only with a complete
glass frame assembly from Empire. See parts list
on Pages 46 - 49 for ordering.
 

to inspect the heater and to replace any part of the
control system and any gas control which has been
under water.
 
an appliance must be replaced prior to operating
the appliance.
 
tile or other combustible material other than wood

or wood panel extending the full width and depth
of the appliance.
The base referred to above does not mean the
fireproof base as used on wood stoves. The
protection is for rugs that are extremely thick and
light colored tile.
 
of high surface temperatures and should stay away
to avoid burns or clothing ignition.
 
they are in the same room as the appliance.
 
placed on or near the appliance.
 
proper operation.
 

        

vapor and liquids.
       
(wood, coal, paper or cardboard etc.) be used in
this appliance.
 
be obstructed in any way.
      
when they are in the same room as the appliance.
Toddlers, young children, and others may be sus-
ceptible to accidental contact burns. A physical
barrier is recommended if there are at-risk individ-

or stove, install an adjustable safety gate to keep
toddlers young children, and other at-risk indiv-
icuals out of the room and away from hot surfaces.
 
the hot viewing glass is provided with this appli-
ance and shall be installed for the protection of
children and other at-risk individuals.
 
be replaced with the manufacturers barrier for
this appliance.
 
servicing an appliance must be replaced prior to
operating the appliance.
IMPORTANT SAFETY INFORMATION
32262-10-0415Page 4
SAFETY INFORMATION FOR USERS OF LP GAS

-
less and colorless. You may not know all the following
safety precautions which can protect both you and your
family from an accident. Read them carefully now, then
review them point by point with the members of your
household. Someday when there may not be a minute to
lose, everyone’s safety will depend on knowing exactly
what to do. If, after reading the following information,
you feel you still need more information, please contact
your gas supplier.
LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the
gas because of the odorant put in the LP-Gas. That’s
your signal to go into immediate action!
• Donotoperateelectricswitches,lightmatches,useyour
phone. Do not do anything that could ignite the gas.
• Geteveryoneoutofthebuilding,vehicle,trailer,orarea.
Do that IMMEDIATELY.
• Closeallgastankorcylindersupplyvalves.
• LP-Gasisheavierthanairandmaysettleinlowareas
such as basements. When you have reason to suspect
agasleak,keepoutofbasementsandotherlowareas.
Stayoutuntilreghtersdeclarethemtobesafe.
• Useyourneighbor’sphoneandcallatrainedLP-Gas
service person and the re department. Even though
you may not continue to smell gas, do not turn on the
gas again. Do not re-enter the building, vehicle, trailer,
or area.
• Finally, let the service man and reghters check for
escaped gas. Have them air out the area before you
return. Properly trained LP-Gas service people should
repair the leak, then check and relight the gas appliance
foryou.
NO ODOR DETECTED - ODOR FADE
Some people cannot smell well. Some people cannot
smell the odor of the chemical put into the gas. You

Smoking can decrease your ability to smell. Being around an
odorforatimecanaffectyoursensitivityorabilitytodetect
that odor. Sometimes other odors in the area mask the gas
odor. People may not smell the gas odor or their minds are
on something else. Thinking about smelling a gas odor can
make it easier to smell.
The odorant in LP-Gas is colorless, and it can fade
under some circumstances. For example, if there is an
underground leak, the movement of the gas through soil
canltertheodorant.OdorantsinLP-Gasalsoaresubject
tooxidation.Thisfadingcanoccurifthereisrustinsidethe
storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or
intowalls,masonryandothermaterialsandfabricsinaroom.
Thatwilltakesomeoftheodorantoutofthegas,reducing
its odor intensity.
LP-Gasmaystratifyinaclosedarea,andtheodorintensity
couldvaryatdifferentlevels.Sinceitisheavierthanair,there
may be more odor at lower levels. Always be sensitive to the
slightestgasodor.Ifyoudetectanyodor,treatitasaserious
leak. Immediately go into action as instructed earlier.
SOME POINTS TO REMEMBER
•  Your local LP-
GasDealercangiveyoua“ScratchandSniff”pamphlet.
Useittondoutwhatthepropaneodorsmellslike.If
you suspect that your LP-Gas has a weak or abnormal
odor, call your LP-Gas Dealer.
• Ifyouarenotqualied,donotlightpilotlights,perform
service,ormakeadjustmentstoappliancesontheLP-
Gassystem.Ifyouarequalied,consciouslythinkabout
theodorofLP-Gaspriortoandwhilelightingpilotlights
orperformingserviceormakingadjustments.
• Sometimesabasementoraclosed-uphousehasamusty
smell that can cover up the LP-Gas odor. Do not try to
lightpilotlights,performservice,ormakeadjustments
in an area where the conditions are such that you may
notdetecttheodoriftherehasbeenaleakofLP-Gas.
• Odorfade,duetooxidationbyrustoradsorptiononwalls
ofnewcylindersandtanks,ispossible.Therefore,people
shouldbeparticularlyalertandcarefulwhennewtanks
orcylindersareplacedinservice.Odorfadecanoccur
innewtanks,orreinstalledoldtanks,iftheyarelled
and allowed to set too long before relling. Cylinders
andtankswhichhavebeenoutofserviceforatimemay
developinternalrustwhichwillcauseodorfade.Ifsuch
conditionsaresuspectedtoexist,aperiodicsnifftestof
the gas is advisable. If you have any question about
the gas odor, call your LP-Gas dealer. A periodic sniff
test of the LP-Gas is a good safety measure under
any condition.
• If,atanytime,youdonotsmelltheLP-Gasodorantand
you think you should, assume you have a leak. Then take
thesameimmediateactionrecommendedaboveforthe
occasion when you do detect the odorized LP-Gas.
• Ifyouexperienceacomplete“gasout,”(thecontainer
isundernovaporpressure),turnthetankvalveoffim-
mediately.Ifthecontainervalveislefton,thecontainer
may draw in some air through openings such as pilot light
orices.Ifthisoccurs,somenewinternalrustingcould
occur.Ifthevalveisleftopen,thentreatthecontainer
as a new tank. Always be sure your container is under
vaporpressurebyturningitoffatthecontainerbefore
it goes completely empty or having it relledbeforeitis
completely empty.
32262-10-0415 Page 5
REQUIREMENTS FOR MASSACHUSETTS
Forallsidewallhorizontally ventedgasfueledequipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
sidewall exhaustventtermination islessthan sevenfeet
abovenishedgradeintheareaoftheventing,includingbut
notlimitedtodecksandporches,thefollowingrequirements
shallbesatised:
1. INSTALLATION OF CARBON MONOXIDE
DETECTORS.Atthetimeofinstallationofthesidewall
horizontal vented gas fueled equipment, the installing
plumber or gastter shall observe that a hard wired
carbon monoxide detector with an alarm and battery
back-up is installed on the oor level where the gas
equipment is to be installed. In addition, the installing
plumber or gastter shall observe that a battery
operated or hard wired carbon monoxide detector
with an alarm is installed on each additional level of
the dwelling, building or structure served by the side
wall horizontal vented gas fueled equipment. It shall
be the responsibility of the property owner to secure
theservicesofqualiedlicensedprofessionalsforthe
installationofhardwiredcarbonmonoxidedetectors
a. In the event that the side wall horizontally vented
gasfueledequipmentisinstalledinacrawlspaceor
an attic, the hard wired carbon monoxide detector
with alarm and battery back-up may be installed on
thenextadjacentoorlevel.
b. Intheeventthattherequirementsofthissubdivision
can not be met at the time of completion of
installation,theownershallhaveaperiodofthirty
days to comply with the above requirements;
provided, however, that during said thirty day period,
a battery operated carbon monoxide detector with
an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS.
Each carbon monoxide detector as required in
accordance with the above provisions shall comply
with NFPA 720 and be ANSI/UL 2034 listed and IAS
certied.
3. SIGNAGE.Ametalorplasticidenticationplateshallbe
permanentlymountedtotheexteriorofthebuildingata
minimumheightofeightfeetabovegradedirectlyinline
with the exhaust vent termination for the horizontally
ventedgasfueledheatingapplianceorequipment.The
sign shall read, in print size no less than 1/2 inch in size,
      
ALL OBSTRUCTIONS”.
4. INSPECTION.The state or local gas inspector of the
sidewallhorizontallyventedgasfueledequipmentshall
not approve the installation unless, upon inspection,
the inspector observes carbon monoxide detectors and
signageinstalledin accordancewiththe provisions of
248 CMR 5.08(2)(a) 1 through 4.
(b) EXEMPTIONS:Thefollowingequipmentisexempt
from248CMR5.08(2)(a)1through4:
1. The equipment listed in Chapter 10 entitled
“EquipmentNotRequiredToBeVented”inthe
mostcurrenteditionofNFPA54asadoptedby
the Board; and
2. Product Approved side wall horizontally vented
gas fueled equipment installed in a room or
structureseparatefromthedwelling,buildingor
structureusedinwholeorinpartforresidential
purposes.
(d) MANUFACTURER REQUIREMENTS - GAS
EQUIPMENT VENTING SYSTEM NOT
PROVIDED.When themanufacturerofaProduct
Approvedside wallhorizontallyventedgasfueled
equipmentdoesnotprovidethepartsforventingthe
uegases,butidenties“specialventingsystems”,
thefollowingrequirementsshallbesatisedbythe
manufacturer:
1. The referenced “special venting system”
instructions shall be included with the appliance
or equipment installation instructions; and
2. The“specialventingsystems”shallbeProduct
Approved by the Board, and the instructions
for that system shall include a parts list and
detailed installation instruction.
(e) AcopyofallinstallationinstructionsforallProduct
Approvedside wallhorizontallyventedgasfueled
equipment, all venting instructions, all parts lists
for venting instructions, and/or all venting design
instructions shall remain with the appliance or
equipmentatthecompletionoftheinstallation.
32262-10-0415Page 6
Instructions to Installer
1. Installermustleaveinstructionmanualwithownerafter
installation.
2. Installermusthaveownerlloutandmailwarrantycard
suppliedwiththereplace.
3. Installer should show owner how to start and operate the
replace.
Thisdirectventgasreplaceheaterisdesignedtooperate
withallcombustionairbeingsiphonedfromtheoutsideofthe
buildingandallexhaustgasesexpelledtotheoutsideofthe
building.Theinformationcontainedinthismanualpertainsto
all models and gas control systems unless otherwise noted.

Warning: This unit is not for use with solid fuels.
ThisreplaceisdesigncertiedinaccordancewithAmerican
National Standard/CSA Standard ANSI Z21.88/CSA 2.33 and
by Underwriters Laboratories as a Direct Vent Gas Fireplace
Heater and shall be installed according to these instructions.
Consult your local building code agency, prior to installation,
to ensure compliance with local codes-including permits and
inspections.
Thereplace,wheninstalled,mustbeelectricallygrounded
inaccordancewithlocalcodesor,inabsenceoflocalcodes,
with the National Electric Code ANSI/NFPA 70 or Canadian
Electriccode,CSAC22.1,ifanexternalelectricalsourceis
utilized.
These models may be installed in a bedroom or bed-sitting
room in the U.S.A. and Canada.

Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of
equipmentshallbeperformedonlybyaqualiedagency.The
term“qualiedagency”meansanyindividual,rm,corporation
or company which either in person or through a representative
isengaged inandisresponsible for(a)the installationor
replacementofgaspipingor(b)theconnection,installation,
repairorservicingofequipment,whoisexperiencedinsuch
work,familiarwithallprecautionsrequiredandhascomplied
withalltherequirementsoftheauthorityhavingjurisdiction.
State of Massachusetts: The installation must be made
byalicensedplumberorgastterintheCommonwealth
ofMassachusetts.
Warning:ANYCHANGETOTHISFIREPLACEORITS
CONTROLS CAN BE DANGEROUS.
Improperinstallationoruseofthereplacecancause
seriousinjuryordeathfromre,burns,explosions,or
carbon monoxide poisoning.
The installation must conform with local codes or, in the
absenceoflocal codes, with theNational Fuel Gas Code
ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation
Code, or CSA B149.1 in Canada. *Available from the American
National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036.
Any alteration of the original design, installed other than
as shown in these instructions or use with a type of gas
not shown on the rating plate is the responsibility of the
person and company making the change.
Important
AllcorrespondenceshouldrefertocompleteModelNumber,
SerialNumberandtypeofgas.
High Altitude
Wheninstallingthisunitatanelevationabove2000feet(in
the United States) it may be necessary to decrease the input
ratingbychangingtheexistingburner orice to a smaller
size.Generally,inputshouldbereduced4percentforeach
1000feetabovesealevel.However,iftheheatingvalueof
the gas has been reduced, this general rule may not apply.
CheckwithEmpireComfortSystemsforproperoricesize
identication.
Canadian High Altitude
Altitude:0-4500feet(0-1370m)
Wheninstallingthisunitatanelevationabove4500feet(in
Canada),checkwithEmpireComfortSystems.
Consult your Empire Comfort Systems for assistance in
determiningtheproperoriceforlocation.
Preparation
Thisdirectventgasreplaceanditscomponentsaretested
andsafewheninstalledinaccordancewiththisInstallation
Manual. Report to your dealer any parts damaged in shipment,
specically check glass condition. Do not install unit with
damaged, incomplete, or substitute parts. Read all instructions
before starting installation and follow these instructions
carefullyduringinstallationtoinsuremaximumbenetand
safety.Failuretofollowthemwillvoidyourwarrantyandmay
presentarehazard.
The warranty will be voided by, and the warranter disclaims
anyresponsibilityforthefollowingactions:
• Installation of any damaged replace or vent system
component.
• Modicationofthereplaceordirectventsystem.
• InstallationotherthanasinstructedbyEmpireComfort
Systems, Inc.
• Improperpositioningofthelogs,glassdoorordecorative
rock.
• Installation and/or use of any component part not
manufacturedorapprovedbymanufacturer.
INTRODUCTION
32262-10-0415 Page 7
SPECIFICATIONS
DVCC32NAT DVCC32LP DVCC36NAT DVCC36LP DVCC42NAT DVCC42LP
Input BTU/Hr Maximum 24,000 22,000 26,000 24,000 28,500 26,500
Input BTU/Hr Minimum (millivolt only) 18,000 18,000 19,000 19,000 21,000 22,000
KWH (Maximum) 7.03 6.45 7.62 7.03 8.35 7.77
KWH (Minimum) 5.27 5.27 5.57 5.57 6.15 6.3
Orice 42 54 40 1.45mm 39 1.55mm
Air Shutter Opening 1/4” Full Open 1/4” Full Open 1/4” Full Open
GasInletShutoffValve(Pipe) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
NOTE: Air shutter settingsare factory minimumsettings. Some ventingcongurations mayrequireminor airshutter adjustments for
optimumperformance.
GAS SUPPLY PRESSURES
GAS TYPE MAXIMUM MINIMUM MANIFOLD
NAT 14.0” 4.5” 3.5”
LP 14.0” 10.8” 10.0”
Remote Control Options
& Accessories
Description Models Used On
FRBC Millivolt Battery Remote ON/OFF DVCC(32,36,42)BP(3,7)
FRBTC Millivolt Battery Remote Thermostat DVCC(32,36,42)BP(3,7)
TMW Millivolt Wireless Wall Thermostat DVCC(32,36,42)BP(3,7)
TRW Millivolt Reed Switch Wall Thermostat DVCC(32,36,42)BP(3,7)
FWS-1 Direct Ignition/Millivolt Wall Switch DVCC(32,36,42)BP(3,7)
RVKN-1 Remote Kit, NAT (Stepper Motor) DVCC(32,36,42)BP7N
RVKP-1 Remote Kit, LP (Stepper Motor) DVCC32,36,42)BP7P
Venting Options Description
 Top vent kit (horizontal) - 4½" to 6" (114.3 mm to 152 mm) wall thickness
 Top vent kit (horizontal) - 8" to 12" (203 mm to 305 mm) wall thickness
 Vertical vent kit
DVVK-4F Horizontalexventkit(4'FLEX)
SD46DVA-FCFX7 FlexAdaptorCollar(mustbeusedwithexkits)
FIREPLACE BARRIER SCREENS
SCREEN MODEL DESCRIPTION FIREPLACE MODELS USED ON
DVFB32MBL Fireplace Barrier Screen, Matte Black DVCC32BP
DVFB36MBL Fireplace Barrier Screen, Matte Black DVCC36BP
DVFB42MBL Fireplace Barrier Screen, Matte Black DVCC42BP
Note:Arescreenisrequiredforoperationoftheappliance,butaresoldseparately.Followtheinstructionsthatcomewithyourrescreen
forproperinstallation.
32262-10-0415Page 8
Model Number Description
FBB10 Blower, Auto Variable-Speed
LK6 Lighting Kit, 120 V
DG1BKP Decorative Glass, Crushed, Black
DG1BUC Decorative Glass, Crushed, Blue
DG1CLF Decorative Glass, Crushed, Clear

interior. Contact your Empire Comfort Systems Dealer (see Page 50) for further information. Do not operate the

ThefollowingaccessorypartscanbeobtainedfromyourEmpireComfortSystemsdealer.Ifyouneedadditionalinforma-
tion beyond what your dealer can furnish, contact Empire Comfort Systems Inc., 918 FreeburgAve., Belleville, Illinois
62220-2623.
ACCESSORIES
32262-10-0415 Page 9

BENCH INSTALLATION (BEFORE INSTALLED IN WALL)
1. With Power completely turned off, Remove plate and four
screwsfromrightpanel.See Figure 1.
Figure 1
2. Install the blower onto the prebent brackets on the blower
plate. Ensure the Velcro connects to secure the blower in
place. See Figure 2.
Figure 2
3. Route wiring through opening.
4. Secure blower assembly into place per step 2 with velcro.
5. Install thermo disc by snapping into valve bracket burner as-
sembly. See Figure 3.
Figure 3
6. Connect Power source into outlet.
BLOWER INSTALLATION (AFTER INSTALLED IN WALL)
1. Makesurepoweristurnedoffpriortoanyremoval.Liftand
pullpaneltoremovefrombottomassembly.See Figure 4.
Figure 4
2. Undotwolatchesatbottomofburnerassembly.See Figure
5.
Figure 5
32262-10-0415Page 10

3. Disengage Glass Frame by pulling in upward swinging
position. See Figure 6.
Figure 6
4. Remove grate by disassembling and removing the three
screws on top panel. See Figure 7.
Figure 7
5. Remove log support by removing the two screws securing the
metal plate to log support. See Figure 8.
Figure 8
6. Remove the four screws securing burner and slide to right
thenliftburneroff.See Figure 9.
Figure 9
7. Removesevenscrewsandliftfireboxassembly.See Figure
10.
Figure 10
8. Removethefour#10x1/2screwssecuringthelatchassem-
blytotheundersideofthereboxandsetaside.See Figure
11.
Figure 11
32262-10-0415 Page 11
9. Installblowerthroughreboxcutout.See Figure 12.
Figure 12
10. Install the blower onto the prebent brackets on the blower
plate. Ensure the Velcro connects to secure the blower in
place. See Figure 13.
Figure 13
11. Reinstall the latch assembly removed in step 8.
See Figure 11.
12. Reinstall the burner assembly and seven screws removed in
step 7. See Figure 10.
13. Reinstalltheburnerandfourscrewsremovedinstep6.
See Figure 9.
14. Reinstall the log support and secure it with the metal plate and
two screws removed in step 5. See Figure 8.
15. Reinstall the grate three screws removed in step 4.
See Figure 7.
16. Install thermo disc by snapping into valve bracket burner as-
sembly. See Figure 14.

Figure 14
17. Connect Power source into outlet.
18. Reinstalltheglassframeremovedinstep3.See Figure 6.
19. Reconnectthelatchesatthebottomofthereboxassembly.
See Figure 5.
20. Replace bottom assembly removed in step 1. See Figure 4.
6
2
3
4
1
5
7
BLOWER ASSEMBLY PARTS LIST
INDEX
NO.
PART
NO
DESCRIPTION QTY
1 R2804 BLOWER ASSEMBLY 1
2 R7649 FAN, CONTROL L120-20 1
3 R3529 CORD SET, 30 INCHES 1
4 R4192 RHEOSTAT, KNOB 1
5 R4186 RHEOSTAT, 3.0 AMP 115 VAC 1
6 10088 RHEOSTAT BOX BRACKET 1
7 R11768 WIRE HARNESS, FAN CONTROL 1
32262-10-0415Page 12
Figure 15
Special Venting Components (Simpson Duravent)
SeeEmpireComfortSystemsRetailPriceListforSimpsonDuraventpartnumbers
and pricing.
Special DV Vent Kits
AvailablefromEmpireComfortSystems,Inc.dealers
DVVK-4FV Vertical Flex Vent Kit 4" x 7"

(DVVK-4V)
Direct-Vent Fireplace Vent Kit - Vertical.

(DVVK-4T)
Direct-VentFireplaceVentKitforTopVent,Thru-the-wall,8to
11 inch wall thickness, Includes SD-911, SD-985, SD-990 and
SD-942

(DVVK-4TS)
Direct-VentFireplaceVentKitforTopVent,Thru-the-wall,5to
7 inch wall thickness, Includes SD-908, SD-985, SD-990 and
SD-942
VENT SYSTEM IDENTIFICATION
Thefollowingventsystemsareacceptableforuse:
SimpsonDuravent®GS4"-6⅝"
AmericanMetalProducts4”-6-5/8”
SelkirkDirect-Temp®4”-6-5/8”
SecuritySecureVent®4”-6-5/8”
EmpireFlexventKitDVVK-4F,refertopage32-33.
SPECIAL VENT SYSTEMS
Begintheventsysteminstallationbyselectingthetypeofventing
tobeinstalledandthepaththatitwilltake.Verifythatclearances
aremetthroughoutthepathoftheventingsystem.Determineifthe
replaceistobeventedoutthetop.
Determinehowtheventsystemwillbeterminatedoutthesideofthe
houseorthroughtheroof.Verifytheclearancesforthetermination.
NOTE: Unit requires 12 inches of rise before elbow, as well

32262-10-0415 Page 13
FIREPLACE DIMENSIONS
DIMENSIONS
Index Letter DVCC32 DVCC36 DVCC42
A 34”(863mm) 37”(940mm) 43”(1092mm)
B 31”(787mm) 34”(863mm) 40”(1016mm)
C 28-7/8”(733mm) 28-7/8”(733mm) 30-7/8”(784mm)
D 38-3/8”(975mm) 38-3/8”(975mm) 40-3/8”(1025mm)
E 38-1/8”(968mm) 38-1/8”(968mm) 40-1/8”(1019mm)
F 16”(406mm) 16”(406mm) 16”(406mm)
H 6-3/4”(171mm) 6-3/4”(171mm) 6-3/4”(171mm)
I 23-1/8”(587mm) 26-1/8”(663mm) 32-1/8”(816mm)
J 11-9/16”(294mm) 13-1/16”(332mm) 16-1/16”(408mm)
K 9-3/16”(233mm) 9-3/16”(233mm) 9-3/16”(233mm)
L 5”(127mm) 5”(127mm) 5”(127mm)
M 2”(51mm) 2”(51mm) 2”(51mm)
N 2”(51mm) 2”(51mm) 2”(51mm)
O 5-5/16”(135mm) 5-5/16”(135mm) 5-5/16”(135mm)
P 34-3/8”(873mm) 34-3/8”(873mm) 34-3/8”(873mm)
Q 13/16”(21mm) 13/16”(21mm) 13/16”(21mm)
32262-10-0415Page 14
CLEARANCES
Clearance to Combustibles
Back 0" (0 mm)
Side 0" (0 mm)
Floor 0" (0 mm)
TopStand-off 0" (0 mm)
Top Framing Edge 3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTEL DEPTH
NAILING
FLANGES
GLASS FRONT
TOP
FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTEL CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOPOF
FIREPLACE
NAILING
FLANGES
STAND OFF
ABOVE TOP
FIREPLACE
Figure 16
Combustible Material
Nogreetingcards,stockingsorornamentationofanytypeshould
be placed on or attached to the replace. The ow of heat can
ignite combustibles.
Note:WhenusingEmpireEMBF,UMC,andUMFSeriesFullMan-
tels,combustibleclearancemaybereducedto1”clearancefrom
topedgeofreplaceface.
FRONT FACE (SIDE)
FIREPLACE
(TOP VIEW)
3
MAX.
PERPENDICULAR
SIDE WALL
45°
6
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED
AREAS
Figure 17
Mantel Chart
FIREPLACE OPENING
INDEX
LETTER
DISTANCE FROM TOP
EDGE OF FIREPLACE
(VERTICAL)
DISTANCE FROM
FIREPLACE FRONT
(HORIZONTAL)
A 18”(457mm) 12”(305mm)
B 18”(457mm) 10”(254mm)
C 16-3/4”(425mm) 8”(203mm)
D 14”(356mm) 6”(152mm)
E 11”(279mm) 3-3/4”(95mm)
F 9”(229mm) 2-1/4”(57mm)
G 6”(152mm) 0”(0mm)
Figure 18
Clearances
Minimumclearancefrombottomfrontedgeofreplacetoceilingis84”
Minimumclearancefromsideofreplacetoadjacentsidewallis6”.
84”
(213cm)
6” (152mm)
Figure 19
32262-10-0415 Page 15
Figure 20
Note:IslandandRoomDividerinstallationispossibleaslongasthehorizontalportionoftheventsystemdoesnotexceed20feetwitha
minimumverticalrunof8feet.SeedetailsinVentingSection.
WhenyouinstallyourDirectVentFireplaceinRoomdividerorFlatonwallcornerpositions,aminimumof6inchesclearancemustbe
maintainedfromtheperpendicularwallandthefrontedgeoftheappliance.
LOCATING FIREPLACE
32262-10-0415Page 16
GAS SUPPLY
Thegaspipelinecanbebroughtinthroughtherightorleftsideof
the appliance. Consult the current National Fuel Gas Code, ANSI
Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
Recommended Gas Pipe Diameter
Pipe Length
Schedule 40 Pipe
Inside Diameter
Tubing, Type L
Outside Diameter
Nat. L.P. Nat. L.P.
0-10feet
0-3 meters
1/2”
12.7 mm
3/8”
9.5 mm
1/2”
12.7 mm
3/8”
9.5 mm
10-40feet
4-12 meters
1/2”
12.7 mm
1/2”
12.7 mm
5/8”
15.9 mm
1/2”
12.7 mm
40-100feet
13-30 meters
1/2”
12.7 mm
1/2”
12.7 mm
3/4”
19 mm
1/2”
12.7 mm
100-150feet
31-46 meters
3/4”
19 mm
1/2”
12.7 mm
7/8”
22.2 mm
3/4”
19 mm
Note:Neveruseplasticpipe.Checktoconrmwhetheryour
local codes allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is
always best to consult your local authority and installation code.
Theuseofthefollowinggasconnectorsisrecommended:
— ANSZ21.24ApplianceConnectorsofCorrugatedMetalTubing
and Fittings.
— ANSZ21.45AssembledFlexibleApplianceConnectorsofOther
Than All-Metal Construction
Theaboveconnectorsmaybeusedifacceptablebytheauthority
having jurisdiction. The state of Massachusetts requires that a
exibleapplianceconnectorcannotexceedthreefeetinlength.
Figure 21
Gas Supply Pressure (inches w.c.)
Minimum Normal Maximum
Natural Gas 4.5" 7.0" 14.0"
LP (Propane) 10.8" 11.0" 14.0"
ManifoldPressure(inchesw.c.)
Normal (HI)
Natural Gas 3.5"
LP (Propane) 10.0"
Installing a New Main Gas Cock (Check Local Code)
Each appliance should have its own manual gas cock.
Amanualmaingascockshouldbelocatedinthevicinityoftheunit.
Where none exists, or where its size or location is not adequate,
contactyourlocalauthorizedinstallerforinstallationorrelocation.
Compoundsusedonthreadedjointsofgaspipingshallberesistant
totheactionofliqueedpetroleumgases.Thegaslinesmustbe
checkedforleaksbytheinstaller.Thisshouldbedonewithasoap
solutionwatchingforbubblesonallexposedconnections,andif
unexposed, a pressure test should be made.

be disconnected from piping at inlet of control valve and pipe
capped or plugged for pressure test. Never pressure test with

NOTE: The millivolt gas controls are equipped with a captured screw
typepressuretestpoint,thereforeitisnotnecessarytoprovidea
1/8inchtestpointupstreamofthecontrol.
Ondirectignitionvalves,hexplugsmaybereplacedwithhosettings
forpressurechecks,thenreinstalledbeforeoperatingreplace.
Whenusingcopperorexconnectoruseonlyapprovedttings.
Theapplianceandit’sindividualshutoffvalvemustbedisconnected
fromsupplypipingsystemduringanypressuretestingofthatsystem
attestpressuresinexcessof1/2psig(3.5kPa).
Theappliancemustbeisolatedfromthegassupplypipingsystem
byclosingitsindividualmanualshutoffvalveduringanypressure
testingofthegassupplypipingsystemattestpressuresequalto
or less than 1/2 psig (3.5 kPa).
Attention! Ifoneoftheproceduresresultsinpressuresinexcess
of1/2psig(14”w.c.)(3.5kPa)onthereplacegasvalve,itwill
result in a hazardous condition.
Checking Manifold Pressures
Both Propane and Natural gas valves have a built-in pressure
regulatorinthegasvalve.Naturalgasmodelswillhaveamanifold
pressureofapproximately3.5”w.c.(.871kPa)atthevalveoutlet
withthe inletpressure to thevalve froma minimumof 4.5” w.c.
(1.120kPa)forthepurposeofinputadjustmenttoamaximumof
14.0”w.c.(3.484kPa).Propanegasmodelswillhaveamanifold
pressure approximately 10.0” w.c. (2.49kPa) at the valve outlet
withtheinletpressuretothevalvefromaminimumof10.8”w.c.
(2.68kPa)forthe purposeofinputadjustment toamaximumof
14.0”w.c.(3.484kPa).
2”
9 3/4
GAS LINE HOLE
FROM FRONT ANGLE
OF APPLIANCE TO
GAS LINE HOLE
Figure 22
32262-10-0415 Page 17
INSTALLATION
Framing and Finishing
1. Choose unit location.
2. Frameinreplacewithaheaderacrossthetop.Itisimportant
toallowfornishedfacewhensettingthedepthoftheframe.
3. Attachreplacetoframeusingadjustableframe.Presetdepth
tosuitfacingmaterial(adjustableto1/2”,5/8”or3/4”depths).
4. Locatethenailingangesonthesidesoftherebox(twoeach
side).
5. Loosen but do not remove the eight screws securing the nailing
angestotherebox.See Figure 23.
Figure 23
6. Measurefromfaceofreplacetofaceofdrywallstriptodetermine
naldepthandadjustnailingangesasshowninFigure 24.
Figure 24
7. Tighten the eight screws loosened in step 5.
8. Bendthenailinganges90degreeasshowninFigure 25.
Figure 25
Figure 26
Vent Pipe Clearance
Note: Maintaintwoinchesofclearancearoundverticalventpipe
onrst12”.See Figure 27.
For horizontal vent, maintain a minimum 1 inch clearance to the
bottomandsidesofthevent,and3inchclearancetocombustibles
above the vent pipe. See Figure 28.
NOTE: Need2inchclearancearoundpipefortherst12inch
above Firebox.
VENT PIPE
2” MINIMUM CLEARANCE AROUND VENT PIPE
Figure 27
Top of Vent
Combustibles NO
T
allowed in shaded
area
1"
1"
3"
(25 mm)
7
Diameter
intake vent
4 Diameter flue
(25 mm)
(76 mm)
Figure 28
32262-10-0415Page 18
INSTALLATION (continued)
Framing
Fireplaceframingcanbebuiltbeforeorafterthereplaceisset
in place. Framing should be positioned to accommodate wall
coveringandreplacefacingmaterial.Thereplaceframingshould
beconstructedof2x4lumber.Theframingheadersmayreston
thereplace standoffs.Refer toFigure 29 for minimumframing
dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
Framing dimension "A" includes a three inch clearance for
   


Note:Fornishingtotopofreplace,refertoFigure 30.
DVCC32 DVCC36 DVCC42
"A" 38-5/8”
(981 mm)
38-5/8”
(981 mm)
40-5/8””
(1032 mm)
"B" 34-5/8”
(879 mm)
37-5/8”
(956 mm)
43-5/8”
(1108 mm)
"C" 15-3/4”
(400 mm)
15-3/4”
(400 mm)
15-3/4”
(400 mm)
Figure 29
Finishing
Finish the walls with the material of your choice. Figure 18 on
page 14 shows the minimum vertical and corresponding maximum
horizontaldimensionsofmantelsorothercombustibleprojections
abovethetopfrontedgeofthereplace.
Only non-combustible materials may be used to cover the black
replacefront.
      
or modify the air inlet/outlet louvers in any manner.
Provide adequate clearances around air openings into the
combustion chamber.
Caution: Ifthejointsbetweenthenishedwallandthereplacesur-
round (top and sides) are sealed, a 300 Degree F minimum sealant
materialmustbeused.Thesejointsarenotrequiredtobesealed.
Only non-combustible material (using 300 Degree F minimum adhe-
siveifneeded),canbeappliedasfacingtothereplacesurround.
Flush Wall Installation
FINISHED WALL
FRONT TRIM OR
NON-COMBUSTIBLE MATERIAL
(INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
2 X 4
HEADER
STAND OFF
Note: Ifinteriorofchaserequiresdrywallperlocalcode,2x4Header
must be reduced to 2 x 2.
Figure 30
NOTE: If the Interior of the chase is required by local code to

with 2 x 2 lumber to meet clearances.
Figure 31
32262-10-0415 Page 19
INSTALLATION (continued)
Combustible Surround Installation
FINISHED WALL
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
MATERIAL (SEALANT IS OPTIONAL)
° C
SEALANT
COMBUSTIBLE SURROUND
MANTELSHELF
2 X 4
HEADER
STAND OFF
Figure 32
Attention: Cold climate installation recommendation: When
installing this unit against a non-insulated exterior wall, it is
recommendedthatthe outer wallsbe insulated toconform to
applicable insulation codes.
Vent Runs
Inplanningtheinstallationforthereplace,itisnecessarytoinstall
certaincomponentsbeforetheapplianceiscompletelypositioned
andinstalled.Theseincludethedirectventsystem,gaspipingfor
theapplianceandtheelectricalwiring.(Ifthefanoptionisused.)
Theappliancecanbemountedonanyofthefollowingsurfaces:
1. Aat,hardcombustible(burnable)surface.
2. Araisedwoodenplatform.
3. Fourcornersupports.(Example:Fourconcretemasonryblocks.)
These supports must be positioned so they contact all four
perimeteredgesonthebottomoftheunit.
VERTICAL, 90 DEGREE ELBOW WITH HORIZONTAL
TERMINATION
3” (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
VENT CAP/
THIMBLE
WALL FIRESTOP
“A”
DISTANCE
TO BOTTOM
OF UNIT
12”Rise
Required
“A” DIMENSION
DVCC32 57-1/2”(146cm)
DVCC36 57-1/2”(146cm)
DVCC42 59-1/8”(151cm)
Figure 33
32262-10-0415Page 20
INSTALLATION (continued)
VERTICAL, 90 DEGREE ELBOW TO HORIZONTAL OUT THE
WALL (12” minimum rise before elbow)
90° ELBOW
“A”
PIPE
LENGTH
VENT CAP
WALL FIRESTOP/
THIMBLE
“B”
“C”
"A" "B" "C"
6"
11-1/4”to12-3/4”
(286mm to 324mm)
4-3/4”to6-1/4”
(121mm to 159mm)
9"
14-1/4”to15-3/4”
(362mm to 400mm)
7-3/4”to9-1/4”
(197mm to 235mm)
12"
17-1/4”to18-3/4”
(438mm to 476mm)
10-3/4”to12-1/4”
(273mm to 311mm)
Figure 34
CORNER INSTALLATION - VERTICAL, 90 DEGREE ELBOW
TO HORIZONTAL OUT THE WALL (12” minimum rise before
elbow)
WALL FIRESTOP/
THIMBLE
VENT
CAP
6” (152 mm)
MINIMUM
9” (229 mm)
MINIMUM
Dim. DVCC32 DVCC36 DVCC42
A
37-3/4”
(959 mm)
39-7/8”
(1012 mm)
44-1/8”
(1121 mm)
B
26-3/4”
(679 mm)
28-3/16”
(716 mm)
31-3/16”
(792 mm)
C
12-3/4”
(324 mm)
13-3/4”
(349 mm)
15-15/16”
(405 mm)
D
53-3/8”
(1356 mm)
56-3/8”
(1432 mm)
62-3/8”
(1584 mm)
Figure 35
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Empire DVCC32BP32N-1 Owner's manual

Category
Fireplaces
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI