LG GCS165SVB User manual

Type
User manual

LG GCS165SVB is a chest freezer with a capacity of 165 liters, ideal for storing frozen food in bulk. It features a direct cooling system, which ensures even cooling throughout the freezer. The freezer also includes a heater defrost system, which helps to prevent frost and ice buildup, making it easy to maintain. Additionally, the freezer comes with a lock and key system, providing extra security for your stored items.

LG GCS165SVB is a chest freezer with a capacity of 165 liters, ideal for storing frozen food in bulk. It features a direct cooling system, which ensures even cooling throughout the freezer. The freezer also includes a heater defrost system, which helps to prevent frost and ice buildup, making it easy to maintain. Additionally, the freezer comes with a lock and key system, providing extra security for your stored items.

CHEST FREEZER
SERVICE MANUAL
CAUTION
BEFORE SERVICING THE UNIT, READ
THE "SAFETY PRECAUTIONS" IN THIS MANUAL.
COLOR: PCM-Super WhiteMODEL: GCS165SV
http:/ /biz.lgservice.com
CONTENTS
-2-
SAFETY PRECAUTIONS
(Page)
SAFETY PRECAUTIONS ............................................................................................................................................................. 2
SERVICING PRECAUTIONS ....................................................................................................................................................... 3
SPECIFICATIONS .......................................................................................................................................................................... 4
DISASSEMBLY ................................................................................................................................................................................ 6
DOOR .............................................................................................................................................................................................. 6
HANDLE ........................................................................................................................................................................................ 6
THERMOSTAT................................................................................................................................................................................ 6
ADJUSTMENT ............................................................................................................................................................................ 7
CIRCUIT DIAGRAM ..................................................................................................................................................................... 8
TROUBLESHOOTING ................................................................................................................................................................... 9
COMPRESSOR AND ELECTRIC COMPONENTS ............................................................................................. ............................................................................................. . 10
PTC .............................................................................................. ................................................................................................... 11
OTHER ELECTRIC COMPONENTS ........................................................................................................................................... 12
EXPLODED VIEW .... . .................................................................................................................................................................. 13
8. Do not open the sealed refrigeration system. It could
9. Curatorial, combustible, explosive, corrosive and volatile
goods cannot be stored in the chest freezer.
11. Chemic reagent is not allowed when washing the chest
freezer. Pls clean it both inside and outside with soft cloth
in litmusless soap water or abluent.
10. Turn off the power and open the door, take the goods to
make defrosting when frost thickness is more than 5mm.
Acuate or hard tools are not allowed to make defrosting.
cause injury or pollute the air. Leave this job to an
autherized servicer with the appropriate refrigerant
recovery equipment.
Please read the following before servicing your
refrigerator.
1. Check if electric leakage occurs in the set.
2. When servicing current applying parts, unplug prior to
servicing.
3. If testing with power on, wear rubber gloves to prevent
electric shock.
4. Be sure to check regular current, voltage, and capacity.
5. Don't touch metal products in a cold freezer compartment
with wet hands. It may cause frostbite or other injury.
6. Prevent water flowing to electric elements in mechanical
parts.
7. When tilting the set, remove any materials on the set,
especially thin plate type (ex,: glass plates or books.)
AIR RECHARGING IN COMPRESSOR
Test the refrigeration system by connecting it electrically before
beginning the refilling operation. This is necessary to ascertain
the function of the motor-compressor and identify defects
immediately. If defects have been found, empty the old system
of R134a residue by breaking off the end of the extension piece
at its narrow point.
(Figure 1) Use the appropriate refrigerant recovery equipment.
Replace the filter and any damaged components. Unsolder and
pull off the piece remaining inside the service tube and then
attach an extension with male Hansen, and last, solder it to the
same tube again. (Figure 2)
POINT TO BE
BROKEN
CHARGE TUBE
EXTENSION
FEMALE
HANSEN
MALE
HANSEN
SOLDERING
POINT
SERVICE TUBE
EXTENSION
Figure 1 Figure 2
SERVICING PRECAUTIONS
-3-
If case that a considerable leakage occurs, it will be necessary
to stop the vacuum pump and add a small quantity of Freon to
the system, if vacuum should not be obtained (pressure gauge
doesn't fall to 1 atmosphere.) Start the refrigeration unit and
find the leakage with a special leak-finder. When the defective
soldering point is visible, repair it after opening the extension
tube valve and reestablishing the normal outside pressure
inside the system.
Because the melted solder is sucked into the tubes and blocks
them, the pressure must be rebalanced when vacuum is in the
system for soldering. As soon as the vacuum operation is over,
add the quantity (in grams) of R134a to the refrigeration
system. Remember that every system has an exact quantity of
R134a with a tolerance of ±5 grams than can be added.
(Figure 5)
TO THE
R-134a CYLINDER
TO THE
REFRIGERATION
SYSTEM
FILLING OR
CHARGE TUBE
VALVE TO BE
OPENED WHEN
REFILLING
TO THE
REFRIGERATION
SYSTEM
TO THE
CHARGE
CYLINDER
VALVE TO BE
CLOSED
AFTER VACUUM
TO THE
VACUUM
PUMP
TO THE
VACUUM
PUMP
PRESSURE
GAUGE
Before performing this operation (if the vacuum pump and
refilling cylinder are connected), make sure that the valve
placed between the vacuum pump and refilling tube are closed
to keep the Freon from adding to the system.(Figure 6)
In addition, check the graduated scale on the cylinder for the
quantity of R134a to be added; for example, if we have 750
grams of Freon in the cylinder and must add 165 grams to the
group, this amount will be reached when R134a has dropped to
585 grams, remembering that the indicator shows a lower limit
of meniscus. Do this after choosing the scale corresponding to
the gas pressure different scales reported as the same gas
pressure indicated by the pressure gauge on the top of the
column.
To make R134a flow into the system, open the valve placed at
the base of the cylinder and connected to the filling tube. The
amount of Freon cannot be added to the system all at once
because it may cause a blocking of motor-compressor.
Therefore, proceed by adding original quantity of about 20-30
grams and close the valve
immediately thereafter.
The pressure rises and the motor-compressor must start,
sucking the gas and making the pressure go down again.
Regulate the valve again, maintaining the same manner until
reaching the quantity of R134a established for the system being
charged. When the system is running, the suction pressure
must be stabilized from 0.10 to 0.4 atmosphere.
It is necessary to execute the soldering operation with valve
open so that the fumes caused by oil residue can come out
freely without blowholes between two tubes during heating the
point to be soldered.
The extension fitted with the male Hansen is connected to the
female fitting of the vacuum pump tube. (Figure 3) Air
evacuating from the system begins as soon as the pump starts.
The refrigeration system must be kept under vacuum until the
reading on the low-pressure gauge indicates vacuum (0
absolute, -1 atm., -760 mm hg.) In any case, it is advisable to
keep the pump running for about 60 minutes. (Figure 4)
Figure 3
Figure 4
Figure 5
-4-
Φ0.8
molecular siever
Door
Leg Adjust
Lock
Machine room
Decor, cover
Thermistor
ITEMS SPECIFICATIONS
DIMENSIONS (mm)
NET WEIGHT (kg)
COOLING SYSTEM Direct Cooling
TEMPERATURE CONTROL
Knob Dial
DEFROSTING SYSTEM
Heater Defrost
Heat preservation
Cyclopentane
REFRIGERANT
R134a(90 g)
ITEMS SPECIFICATIONS
Capillary
Drier
1 EA
LOCK ASSEMBLY
1 EA
Manual owners (1EA)
Card, warranty (1EA)
Key (2EA)
Cover Glass
Manual,assembly owners (1EA)
COMPRESSOR PTC Starting Type
EVAPORATOR Fin Tube Type
CONDENSER
Ref. No: GCS165SV
SPECIFIC A TIONS
-5-
DISASSEMBLY
I. Instruction for removal of the temperature control component
II. Instruction for removal of the hinge components
1. Removal of the upper housing of the hinge: slightly
move the upper housing of the hinge outwards, and lift
upwards to remove.
2. Removal of the lower housing of the hinge: slightly
move the lower housing of the hinge outwards, and
push downwards to remove.
3. Removal of the hinge: screw off the screws for fixing
the hinge with the pneumatic screw driver to remove
the hinge from the case.
1. Removal of the temperature control component:
hold the fixture on the upper part of the temperature
control panel to push the temperature control
component outwards the case from the compressor
cabinet; hold and lift upwards the top of the
temperature control panel to remove the temperature
control component from the case after pushing.
2. Removal of the temperature control knob:
pull the temperature control knob from the
temperature controller directly.
3. Removal of the temperature controller:
Remove the screw which is used to fix the case controller
and controller panel , separate these 2 parts. Loose and
remove the temperature controller fix nut with Φ15mm sleeve,
4. Removal of the indicator lamp:push aside the clamped hook a little ,
pull the indicator lamp outwards and remove it
1
2
3
4
5
6
-6-
ADJUSTMENT
1. COMPRESSOR
1) Role
The compressor intakes low temperature and low
pressure gas evaporated from Evaporator of the
Refrigerator, and condenses this gas to high temperature
and high pressure gas, and then plays delivering role to
Condenser.
2) Composition
The Compressor is Composed of Compressor Apparatus
compressing gas, Compressor Motor moving Compressor
Apparatus and Case protecting Compressor Apparatus
and Motor. There are PTC-Starter, and Over Load
Protector (OLP) in the Compressor outside. On the other
hand, because the Compressor consists of 1/1000mm
processing precision components and is sealed after
production in absence of dust or humidity, deal and repair
with care.
3) Note for Usage
(1) Be careful not to allow over-voltage and over current.
(2) No Strike
If applying forcible power or strike (dropping or
careless dealing), poor operation and noise may occur
(3) Use proper electric components appropriate to the
Compressor.
(4) Note to Keep Compressor.
If Compressor gets wet in the rain and rust in the pin of
Hermetic Terminal, the result may be poor operation
and poor contact may cause.
(5) Be careful that dust, humidity, and flux welding don't
inflow in the Compressor inside in replacing the
Compressor. Dust, humidity, and flux due to welding
which inflows to Cylinder may cause lockage and
noise.
2. PTC-STARTER
1) Composition of PTC-Starter
(1) PTC (Positive Temperature Coefficient) is a no-contact
semiconductor starting device which uses ceramic
material and this material consists of BaTiO3.
(2) The higher the temperature is, the higher becomes the
resistance value. These features are used as starting
device for the Motor.
2) Role of PTC-Starter
(1) PTC is attached to Hermetic Compressor used for
Refrigerator, Show Case and starts Motor.
(2) Compressor for household refrigerator applies to
single-phase induction Motor.
For normal operation of the single-phase induction motor, in
the starting operation flows in both main coil and sub-coil.
After the starting is over, the current in subcoil is cut off. The
proper features of PTC play all the above roles. So, PTC is
used as a motor starting device.
3) PTC-Applied Circuit Diagram
According to Starting Method for the Motor
4) Motor Restarting and PTC Cooling
(1) For restarting after power off during normal
Compressor Motor operation, plug the power cord
after 5 min. for pressure balance of Refrigerating Cycle
and PTC cooling.
(2) During normal operation of the Compressor Motor,
PTC elements generate heat continuously. Therefore,
if PTC isn't cooled for a while after the power has been
shut off, Motor can't operate again.
5) Relation of PTC-Starter and OLP
(1)
If the power is off during operation of Compressor and the
power is on before the PTC is cooled, (instant shut- off within
2 min. or reconnect a power plug due to misconnecting), the
PTC isn't cooled and a resistance value grows. As a result,
current can't flow to the sub- coil and the Motor can't operate
and the OLP operates by flowing over current in only in the
main-coil.
(2)
While the OLP repeats on and off operation about 3-5 times,
PTC is cooled and Compressor Motor performs normal
operation.
If OLP doesn't operate when PTC is not cooled,
Compressor Motor is worn away and causes circuitshort and
fire. Therefore, use a properly fixed OLP without fail.
6) Note to Use PTC-Starter
(1) Be careful not to allow over-voltage and over-current.
(2) No Strike
Don't apply a forcible power or strike.
(3) Keep apart from any liquid.
If liquid such as oil or water away enter the PTC,
PTC materials it may break due to insulation
breakdown of the material itself.
(4) Don't change PTC at your convenience.
Don't disassemble PTC and mold. If the exterior to the
PTC-starter is damaged, resistance value is altered
and it may cause poor starting of the compressor
motor may cause.
(5) Use a properly fixed PTC.
Figure 19
GN/YL
BN
Optional
P.T.CSTARTER Compressor
BL
OVERLOAD
PROTECTOR
C
C
S
M
t
-7-
3. OLP (OVER LOAD PROTECTOR)
1) Definition of OLP
(1) OLP (OVER LOAD PROTECTOR) is attached to the
Hermetic Compressor and protects the Motor by
cutting off current in Compressor Motor in case of
over-rising temperature by Bimetal in the OLP.
(2) When over-voltage flows to Compressor motor, the
Bimetal works by heating the heater inside the OLP,
and the OLP protects Motor by cutting off current
which flows to the Compressor Motor.
2) Role of the OLP
(1) The OLP is attached to the Hermetic Compressor
used for the Refrigerator and Show Case and prevents
the Motor Coil from being started in the Compressor.
(2) Do not turn the Adjust Screw of the OLP in any way for
normal operation of the OLP.(Composition and
connection Diagram of OLP)
CONTACTING
POINT
COVER
BIMETAL
CONTACTING
POINT
HEATER
TERMINALS
ADJUST
SCREW
HEATER
BIMETAL
Figure 20
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
BN:BROWN BL:BLUE RD:RED BK:BLACK GN/YL:GREEN&YELLOW
GN/YL
GN/YL
GN/YL
GN/YL
BL
BL
BL
BL
BN
Optional
P.T.CSTARTER Compressor
BL
BN
BN
L H
THERMOSTAT
C
BK
RD
RD
BK
Power pilot lamp
Fan
Compressor
pilot lamp
OVERLOAD
PROTECTOR
POWER SUPER CORD
C
C
S
M
t
THE PLUG TYPE ON CIRCUIT DIAGRAM IS SUBJECT TO
CHANGE IN DIFFRENT LOCALITIES.
-8 -
TROUBLESHOOTING (Mechanical Part)
1. COMPRESSOR AND ELECTRIC COMPONENTS
1
2
3
4
5
2
5
5
3
4
5
5
1
43
YES
YES
NO
YES
YES
NO
NO
5
YES
NO
YES
Power
Source.
Remove the Relay Assy
from the Compressor
and measure the voltage
between Terminal C of
Compressor and
Terminals M or S of
Relay Assy
No Voltage.
(Rating Voltage
±10%)
±10%)
Replace
Relay Assy
Replace
Relay Assy
O.K.
Advise the customer
to use a regular
Trans.
Replace Compressor.
OLP works within
30 sec. in forcible
OLP operation by
turning instant power
on and off.
Components start in
the voltage of Rating
Voltage ±
Applied voltage isn't
in the range of Rating
Voltage
Check the resistance
among M-C, S-C and
M-S in Motor
Compressor.
Check the resistance of
two terminals in PTC-
Starter.
Check if applying
a regular OLP.
Measure minimum
starting voltage after 5
min. for balancing cycle
pressure and cooling the
PTC.
Check the
resistance of
Motor
Compressor.
Check the
resistance of
PTC-Starter.
Check OLP.
Check
starting state.
10% below
-9-
2. RELAY ASSY (PTC AND OLP)
L N
T
3 2
2
M
C
SM
C
S
YES
NO
Normal operation of
Compressor is
impossible or poor.
Separate the Relay Assy
from Compressor and
measure the resistance
between M and S with a
Tester or Whistone Bridge.
(Figure 21)
Separate the Relay Assy
from the Compressor and
check the resistance value
between two terminals of
OLP with a Tester.
Observation value is
220V/50Hz : 22
Ω±
30%
115V/60Hz : 6.8
Ω±
30%
240V/50Hz : 33
Ω±
30%
127, 220V/60Hz :
22
Ω±
30%
The resistance value is 0
or serveral hundreds Ω.
The value is ∞.
Check another
electric components.
Replace Relay Assy.
Check another
electric
components.
Replace
Relay Assy.
22 erugiF12 erugiF
-10 -
3. ANOTHER ELECTRIC COMPONENTS
Cooling is impossible
Cooling ability is poor
Compressor
doesn't run.
Running state of
Compressor is poor.
Check a starting
voltage.
Check if current flows to
the following
components.
a. Thermistor
b. Starting devices
c. OLP
d. Compressor coil
e. Circuit Parts
Low voltage.
Poor contacting.
Shorted or broken.
Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Poor contacting
and broken.
Shorted.
Lack of capacity.
Coil of motor
Compressor.
Replace
the compressor.
Replace
each component.
Raise the voltage.
Replace
each component.
Cause.
Check if current flows
to starting devices.
Check current flowing
in sub-coil of
Compressor.
Check capacity of OLP.
The items described
above are normal.
Much frost are sticked
to the EVAPORATOR.
Shorted.
Replace
the Heater, Sheath
Replace
each component.
Check current flowing
of the following
components.
• THERMISTOR
• FUSE, MELTING
Check current flowing
of the following
components.
• HEATER, SHEATH
Fan motor
doesn't run.
Poor contacting.
Coil is shorted.
Replace
each component.
Check current flowing
in SWITCH, DOOR.
Check current flowing in the
MOTOR[MECH], FAN.
TROUBLE SHOOTING
-11-
Fault phenomenon Possible cause for faults Inspection scope Removal Notes:
No input
voltage
existing
Poor contact between the plug
and the socket
Inspect whether the plug and the
socket are loose
Repair or replace the socket Call an electrician
for repair
White indicator
lamp not
operating
Poor contact with the white
indicator lamp
Inspect whether the connector
assembly is loose
Insert the connector assembly
tightly
Input voltage
existing
White indicator lamp damaged Remove the white indicator lamp Replace
Poor contact between the pink
indicator lamp and the plug
foot
Inspect whether the connector
assembly is loose
Insert the connector assembly
tightly
opening
pink indicator lamp damaged Remove the pink indicator lamp Replace
Call professional
for repair
No put the temperature
controller to operating state
position
Inspect the temperature controller Put to the operating state position
as per consideration for use
Pink indicator
lamp not
operating
Poor contact with the
temperature controller
Inspect whether the connector
assembly is damaged
Insert the connector assembly
tightly
Compressor set
not opening
Temperature controller
damaged
Inspect whether open circuit
exists in two connector
assemblies
Replace the temperature controller
Too mush frosting on
evaporator
Inspect whether thickness is more
than 2mm
Remove the frost timely
Over-high frequency of
opening the door
Reduce the frequency of opening
the door as much as possible
Too mush articles in the case Inspect whether it is possible to
impact the circulation of cool air.
Take some food out
Over-temperat
ure in the case
Refrigerating fluid leaking Repair in a maintenance point
machine set
operating
continuously
Over-high ambient
temperature and too low
temperature of the temperature
controller
Inspect whether the knob is put
on Positions 2-4” or forced
cooling
Adjust the knob to Positions
“2-4”
Temperature in
the case
reached
Temperature controller fault Replace the temperature controller
Case no keep flat Inspect whether four castor
wheels touch ground
Cushion timely
Retaining screws of the compressor loosening Inspect whether the screws are
screwed down.
Screw the screws down
Call professional
for repair
Pipelines contacting Separate the pipeline
Starting relay and thermal protection
connector assembly loosening
Inspect whether the connector
assembly is damaged
Insert the connector assembly
tightly
Compressor damaged Repair or replace the compressor
Call professional
for repair
Excessive noise,
red and green
indicator lamps
operating, and
compressor not
operating
Voltage less than 187V Inspect supply voltage Connect a voltage stabilizer over
1000V
If the supply cords are damaged, in order to avoid danger, replacement of the supply cords must be carried out by the manufacturer or its maintenance
department
Note: the following phenomenon is not the fault phenomenon
1. Slight gurgle exists in the temperature-changeable freezing refrigerator occasionally;
2 The compressor and the condenser emit heat, even scald hands;
3 It is possible to generate water bubbles outside the refrigerating cabinet when the ambient temperature is higher.
4 The heat of 50 Celsius degree exists outside the temperature outside.
or similar full-time staff, and it is not allowed to replace without authorization.
EXPLODED VIEW
200A
200B
205B
205A
205A
315A
314A
208B
208B
310B
310B
310B
310B
315B
207A
207B
207C
207D
212A
213A
213B
213C
214A
307A
306B
309A
310A
308A
300A
306D
300B
303A
216A
216B
201A
201B
301B
303D
311C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

LG GCS165SVB User manual

Type
User manual

LG GCS165SVB is a chest freezer with a capacity of 165 liters, ideal for storing frozen food in bulk. It features a direct cooling system, which ensures even cooling throughout the freezer. The freezer also includes a heater defrost system, which helps to prevent frost and ice buildup, making it easy to maintain. Additionally, the freezer comes with a lock and key system, providing extra security for your stored items.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI