bora PKCH3 1xx Assembly Instructions

  • Hello! I'm the chat assistant, and I've read through the installation instructions for the BORA Professional 3.0 series, including models PKA3, PKA3AB, PKAS3, PKAS3AB, PKFI3, PKI3, PKIW3, PKC3, PKCB3, PKCH3, PKT3 and PKG3. This document provides essential information on the safe installation of your appliances, including electrical and gas connections, along with the required cut-out dimensions. I’m ready to assist you with any questions you might have about the device described in the document.
  • What should I do if I notice damage to any parts of the appliance?
    Can the cooktop extractor be installed above other appliances?
    What is the minimum distance required between the control knobs and the cooktop edge?
EN Installation instructions Professional 3.0
004563-10001
bora.com
2bora.com
Contents
1 General information 3
1.1 Validity of the operating and installation
instructions ................................................................3
1.2 Liability ....................................................................... 3
1.3 Product conformity....................................................3
1.4 Data protection ..........................................................3
1.5 Presentation of information ......................................3
1.5.1 Safety and warning instructions ................................. 3
1.5.2 Figures........................................................................ 3
2 Safety 4
2.1 Intended use ..............................................................4
2.2 General safety instructions .......................................4
2.3 Safety information for installation ............................5
2.3.1 Safety instructions – cooktop extractor installation ... 6
2.3.2 Safety information for cooktop installation................. 6
2.4 Safety instructions – repairs, servicing and spare
parts ...........................................................................7
2.5 Safety instructions – disassembly and disposal ......8
3 Technical data 9
3.1 Cooktop extractor PKA3/PKA3AB ............................9
3.2 Cooktop extractor system with integrated fan
PKAS3/PKAS3AB.......................................................9
3.3 Surface induction cooktop PKFI3............................10
3.4 Induction cooktop PKI3 ...........................................11
3.5 Induction wok cooktop PKIW3................................11
3.6 HiLight cooktop, 3-ring/2-ring PKC3......................12
3.7 HiLight cooktop, 3-ring/roaster PKCB3 .................13
3.8 Hyper cooktop, 1-ring/2-ring PKCH3 .....................14
3.9 Tepan stainless steel grill PKT3 ..............................15
3.10 Gas cooktop PKG3 ...................................................16
3.11 Control knob.............................................................16
4 Installation 17
4.1 General installation instructions.............................17
4.1.1 Operating the cooktop extractor in the exhaust air
mode and where there is a fireplace dependent upon
the air supply in the room......................................... 17
4.2 Checking the scope of delivery ...............................18
4.2.1 Scope of delivery of the cooktop extractor............... 18
4.2.2 Scope of delivery of the cooktops ............................ 18
4.3 Tools and aids ..........................................................18
4.4 Assembly instructions .............................................19
4.4.1 Installation clearances.............................................. 19
4.4.2 Minimum installation dimensions ............................. 19
4.4.3 Worktop.................................................................... 19
4.4.4 Kitchen units............................................................. 19
4.4.5 Special assembly instructions for the gas cooktop... 19
4.4.6 Return flow of recirculated air .................................. 20
4.5 Cut-out dimensions..................................................21
4.5.1 Worktop overhang .................................................... 21
4.5.2 Flush installation....................................................... 21
4.5.3 Surface mounting ..................................................... 22
4.6 Control knob installation .........................................22
4.6.1 Cooktop extractor bore holes ................................... 22
4.6.2 Cooktop bore holes .................................................. 22
4.6.3 Example bore holes .................................................. 23
4.6.4 Fitting the control knob ............................................ 23
4.7 Planning variations for PKA3/PKA3AB...................24
4.7.1 Airflow straight to the side........................................ 24
4.7.2 Airflow towards the left ............................................ 24
4.7.3 Rotating the cover frame by 180° ............................ 25
4.8 Installing the cooktop extractor..............................25
4.8.1 Fitting the cooktop extractor .................................... 25
4.8.2 Securing the cooktop extractor ................................ 26
4.9 Installing the duct system.......................................27
4.9.1 Duct connection dimensions .................................... 27
4.9.2 Preparing for installation .......................................... 28
4.9.3 Connecting the duct system to the appliance........... 28
4.9.4 Standard set-up for PKA3/PKA3AB .......................... 28
4.9.5 Positioning the control unit....................................... 29
4.9.6 Installing the additional fan....................................... 29
4.10 Gas installation ........................................................29
4.10.1 Ventilation ................................................................ 29
4.10.2 Gas connection......................................................... 29
4.10.3 Connecting the gas supply ....................................... 29
4.10.4 Additional installation instructions for Australia and
New Zealand (AU/NZ) .............................................. 29
4.10.5 Changing the gas type .............................................. 30
4.11 Installing the cooktops............................................32
4.11.1 Preparing the cooktop extractor when using the wok
cooktop .................................................................... 32
4.11.2 Installing the cooktop ............................................... 33
4.11.3 Installing the Tepan stainless steel grill .................... 33
4.11.4 Cooktop installation rotated by 180° ....................... 34
4.12 Connecting external switch contacts .....................34
4.12.1 Preparing PKAS3/PKAS3AB ..................................... 34
4.12.2 Preparing the control unit on PKA3/PKA3AB ........... 35
4.12.3 Preparing connection cables for external switching
equipment ................................................................ 35
4.12.4 Installing the external switch device......................... 36
4.13 Establishing communication and power connection
..................................................................................37
4.13.1 Connecting the control knobs................................... 37
4.13.2 Ports on cooktop extractor system PKAS3 ............... 40
4.13.3 Connecting cooktop extractor PKA3......................... 40
4.13.4 Establishing contact between the cooktop extractor
and cooktops............................................................ 41
4.13.5 Connecting the power supply ................................... 41
4.14 Basic configuration..................................................43
4.14.1 Gas configuration ..................................................... 43
4.15 Initial operation........................................................43
4.15.1 Using the gas cooktop for the first time ................... 43
4.16 Sealing the appliances.............................................43
4.17 Handover to user .....................................................44
5 Decommissioning, disassembly and
disposal 45
5.1 Decommissioning ....................................................45
5.2 Disassembly.............................................................45
5.3 Environmentally-friendly disposal...........................45
5.3.1 Disposal of transport packaging ............................... 45
5.3.2 Disposal of accessories ............................................ 45
5.3.3 Disposal of the old appliance.................................... 45
General information EN
bora.com 3
1
General information
These instructions contain important information to protect you from
injury and prevent damage to the appliance. Please read these
instructions carefully before installing or using the appliance for the
first time.
Other documents apply alongside these instructions. Please by all
means adhere to all documents that form part of the scope of
delivery.
Assembly, installation and commissioning must always occur in line
with national laws, regulations and standards. The work must be
performed by qualified specialists who know and comply with the
additional regulations of the local energy supply companies.
All safety and warning information as well as the handling instructions
in the accompanying documents must be observed.
1.1
Validity of the operating and
installation instructions
These instructions apply to several appliance versions. It is therefore
possible that some of the features described do not apply to your
appliance. The details of the figures contained herein may differ from
some appliance versions and are to be understood as schematic
diagrams.
These instructions apply to the Professional 3.0 product range
including the All Black model. To simplify things, the instructions do
not include the product numbers for the different models.
1.2
Liability
. BORA Holding GmbH, BORA Vertriebs GmbH & Co KG, BORA APAC
Pty Ltd and BORA Lüftungstechnik GmbH – hereinafter referred to as
BORA – do not assume any liability for damage arising from disregard
for or non-adherence to the documents included in the scope of
delivery!
Furthermore, BORA shall not be held liable for damage caused by
improper installation or failure to observe the safety and warning
information!
1.3
Product conformity
Directives
The appliances meet the following EU/EC directives:
T
2014/30/EU EMC Directive
T
2014/35/EU Low Voltage Directive
T
2009/125/EC Ecodesign Directive
T
2011/65/EU RoHS Directive
Regulations
Gas appliances meet the following EC directives:
T
(EU) 2016/426 regulation on appliances burning gaseous fuels
1.4
Data protection
During operation your cooktop extractor saves pseudonymised data
such as menu settings entered by you, operating hours of the
individual technical units and the number of functions selected.
Furthermore, your cooktop extractor documents errors in
combination with the number of operating hours. Data can only be
read out manually via your cooktop extractor. This decision is
therefore your responsibility. These saved data then enable a rapid
error search and troubleshooting in the event of servicing.
1.5
Presentation of information
We use standard formatting, numbering, symbols, safety instructions,
terms and abbreviations so that you can work quickly and safely
when using this manual. The article described in these instructions is
hereinafter also referred to as an appliance.
Instructions are indicated with an arrow.
u
Always follow all instructions in the prescribed order.
Enumerations are indicated with a bullet point at the start of the line:
T
Enumeration 1
T
Enumeration 2
Information notes point to special features that must be taken
into account.
1.5.1
Safety and warning instructions
The safety and warning instructions in this manual are emphasised
with symbols and signal words. Safety and warning instructions are
structured as follows:
öDANGER
Type and source of danger
Results of non-compliance
u
Measures to minimise risk
Please note:
T
warning symbols draw attention to a high risk of injury.
T
The signal word indicates the severity of that risk.
Warning
symbol
Signal word Risk
Danger Indicates an immediate, hazardous
situation which causes death or
serious injury if not respected.
Warning Indicates a potentially hazardous
situation which can cause death or
serious injury if not respected.
Caution Indicates a potentially hazardous
situation which can cause death or
serious injury if not respected.
Note Indicates a potentially hazardous
situation which can cause property
damage if not respected.
Tab.1.1 Meaning of the warning symbols and signal words
1.5.2
Figures
All measurements are provided in millimetres.
Safety
EN
4bora.com
2
Safety
The appliance complies with the stipulated safety requirements. The
user is responsible for the safe use of the appliance, cleaning and
maintenance. Improper use can lead to personal injury and damage
to property.
2.1
Intended use
The appliance is solely intended for preparing food in private
households.
This appliance is not intended for:
T
outdoor use
T
heating rooms
T
cooling, ventilating or dehumidifying rooms
T
use in mobile installation sites such as motor vehicles, ships or
aeroplanes
T
use with an external timer or a separate remote control system
(except for emergency shutdown in the case of the cooktop
extractor)
T
use at altitudes of over 2000m (metres above sea level)
T
operation with an extractor hood (where a gas cooktop is installed)
T
use when not fully installed
Any other use or any use that goes beyond that which is described
here is classed as unintended.
BORA does not assume any liability for damages caused by
incorrect installation, improper use or incorrect operation.
All misuse is prohibited!
2.2
General safety instructions
öDANGER
Packaging components are a choking hazard
Packaging components (e.g. film, polystyrene) can
be life-threatening for children.
u
Store all packaging components out of reach of
children.
u
Dispose of the packaging properly and
immediately.
öDANGER
Risk of electric shock or injury from damaged
surfaces
The underlying electronics can be exposed or
damaged due to fissures, fractures or cracks in
appliance surfaces (e.g. damaged glass), particularly
in the vicinity of the operating unit. This can cause
an electrical shock. Furthermore, a damaged
surface can cause injuries.
u
Do not touch the damaged surface.
u
If there are any cracks, fissures or fractures,
switch the appliance off immediately.
u
Securely disconnect the appliance from the
mains using the circuit breaker, fuses, automatic
circuit breakers or contactor.
u
Contact BORA Service.
öWARNING
Risk of injury or damage due to incorrect
components or unauthorised modifications
Incorrect components can lead to personal injury or
damage to the appliance. Modifications, additions or
alterations to the appliance can lead to safety risks.
u
Only use original components.
u
Do not make any modifications, additions or
alterations to the appliance.
öWARNING
Risk of injury due to mechanical damage on the
appliance
Mechanical damage (e.g. cracks, deformation,
separation of adhesive seals, etc.) to the appliance,
as well as to cables and accessories can cause
injuries.
u
Do not operate the appliance.
u
Do not try to repair or replace damaged
components yourself.
u
Contact BORA Service.
CAUTION
Appliance components can cause injury if
dropped
Appliance components can cause injury if you drop
them.
u
Place any appliance components that have been
removed in a safe place near the appliances.
u
Ensure that no components removed from the
appliances can fall on the floor.
Safety EN
bora.com 5
CAUTION
Risk of injury from heavy lifting
If not handled correctly, carrying and installing
appliances can cause injury to the limbs or torso.
u
If necessary, carry and install the appliance with
another person.
u
Use appropriate aids to prevent damage or injury.
CAUTION
Damage from improper use
The appliance surfaces must not be used as work or
storage surfaces. This can damage the appliances
(particularly in the case of hard and sharp objects).
u
Never use the appliances as work or storage
surfaces.
u
Keep hard or sharp objects away from the
appliance surfaces.
PLEASE NOTE
Faults and errors
In the event of faults or incorrect use, error
messages will be displayed.
u
In the case of faults and errors, follow the
instructions in the “Troubleshooting” chapter.
u
In the event of any faults or errors that are not
mentioned, switch the appliance off and contact
BORA Service.
PLEASE NOTE
Appliance damage caused by pets
Pets may damage the appliance or injure
themselves.
u
Keep pets away from the appliance.
2.3
Safety information for
installation
öDANGER
Risk of injury from incorrect assembly
Failure to observe the installation instructions can
lead to injury.
u
The appliance must only be installed and
assembled by trained specialists who are familiar
with and comply with the standard national
regulations and supplementary regulations of the
local utility companies.
u
Work on electrical components must only be
conducted by trained electrical personnel.
u
Conduct all work extremely attentively and
conscientiously.
u
Before handing the appliance or system over to
the end user, ensure that it has been correctly
installed.
öDANGER
Risk of electric shock from damaged appliance
A damaged appliance can cause an electric shock.
u
Check the appliance for visible damage prior to
installation.
u
Do not install or connect any damaged
appliances.
u
Do not operate any damaged appliances.
öDANGER
Risk of electric shock from incorrect stripping
of cables
Incorrect stripping of the connection cable to
external switching devices results in a risk of
electric shock.
u
Ensure that the connection cable is secured with
the strain relief clamp within the control unit.
u
Ensure that the stated stripping lengths are
adhered to.
CAUTION
Risk of burning from control knobs that are not
positioned optimally
If the control knobs are not installed in a suitable
place, during operation there is a risk of sustaining
burns from the cooktop surface.
u
Only install the control knobs in a suitable place,
which is practical and safe.
Safety
EN
6bora.com
PLEASE NOTE
Appliance damage caused by incorrect wiring
The electrical safety of the appliance is only
guaranteed if it is connected to a protective
conductor system that has been installed in line
with regulations.
u
Work on electrical components must only be
conducted by trained electrical personnel.
u
Ensure that this basic safety precaution is met.
The appliance must be suitable for the regional
voltage and frequency.
u
Check the information on the identification plate
and in the event of deviations, do not connect the
appliance.
u
Do not connect the appliance to the mains until
the duct system has been installed or the
recirculation filter has been fitted.
u
Only use the connection cables supplied.
PLEASE NOTE
Appliance damage caused by incorrect
installation clearances
Failure to adhere to installation clearances can lead
to damage to the appliance and kitchen units, as
well as restricted functions.
u
During installation maintain the minimum
clearance stated in the Installation chapter.
2.3.1
Safety instructions – cooktop
extractor installation
öDANGER
Risk of smoke inhalation
When the cooktop extractor is used in exhaust air
mode, it draws in air from the room it is installed in
and from neighbouring rooms. Without sufficient air,
there will be a drop in air pressure. When used at
the same time as a fireplace that is dependent on
the air in the room, noxious gases can be sucked
into the living areas from the chimney or outlet
shaft.
u
Make sure that there is always a sufficient air
supply.
u
Only use reliable, tried-and-tested switching
devices, (e.g. window contact switch, low
pressure warning device) and have them
approved by a qualified expert (certified chimney
sweep).
öWARNING
Risk of injury due to turning fan wheel
There is a risk of injury while the fan is turning.
u
Only install the device with the power
disconnected.
u
Connect both sides of the fan to the duct system
before commissioning.
CAUTION
Risk of injury due to turning fan wheel
The vicinity of the fan can be reached if the exhaust
air system has short, straight ducts.
u
In the case of ducts measuring less than 900
mm, a safety guard must be fitted (available as an
accessory).
2.3.2
Safety information for cooktop
installation
öDANGER
Risk of electric shock from damaged power
supply cable
If the power supply cable is damaged (e.g. during
installation or by coming into contact with hot
cooking surfaces), this can cause an (lethal) electric
shock.
u
Make sure that the connection cable does not
become trapped or damaged.
u
Make sure that the power supply cable does not
come into contact with hot cooking surfaces.
öDANGER
Risk of electric shock from incorrect mains
connection
Connecting the appliance to the mains incorrectly
poses a risk of electric shock.
u
Make sure that the appliance has a fixed
connection to the mains voltage.
u
Make sure that the appliance is connected to a
properly installed protective conductor system.
u
Make sure that technical equipment is provided
to enable all of the appliance’s poles to be
disconnected from the mains with a contact
opening width of at least 3mm (circuit breaker
and automatic circuit breakers, fuses, contactor).
Safety EN
bora.com 7
öDANGER
Risk of explosion and asphyxiation from gas
Leaking gas can lead to an explosion and result in
severe injuries and property damage, or
asphyxiation.
u
Keep sources of ignition (naked flames, electric
fires) away and do not operate any light switches,
or switches on electrical appliances.
u
Do not remove plugs from sockets (risk of
sparking).
u
Close the gas supply immediately and turn off the
mains supply.
u
Ensure there is a good supply of fresh air (open
doors and windows).
u
Plug any leaks immediately.
u
Before connecting the appliance, check that the
appliance settings comply with local connection
requirements (gas type and pressure).
öWARNING
Risk of burns from wrongly placed control
knobs
If control knobs are not fitted according to the
installation instructions, they can become hot.
Touching the hot control knobs can cause burns.
u
Control knobs must be fitted at least 10cm from
the edge of the cooktop.
u
If it is not possible to maintain a distance of at
least 10cm, measures must be put in place to
protect the control knobs from the heat.
öWARNING
Risk of injury from incorrect gas installation
Failure to observe the gas installation instructions
can lead to injury.
u
Gas installation, appliance installation and
replacing the gas nozzles, as well as changing the
gas type and pressure, may only be carried out by
reliable trained specialists, who are familiar with
and comply with the standard national
regulations and supplementary regulations of the
local utility companies.
u
Observe the special instructions on changing the
gas type and pressure and the specifications for
changing the gas nozzles in the nozzle table (see
Operating instructions).
u
BORA gas cooktops must only be used with BORA
cooktop extractors.
2.4
Safety instructions – repairs,
servicing and spare parts
öDANGER
Risk of injury when carrying out repairs
Insufficient expertise can lead to injury when
carrying out repairs.
u
The appliance must only be repaired and serviced
by trained specialists who are familiar with and
comply with the standard national regulations
and supplementary regulations of the local utility
companies.
u
Safely disconnect the appliance from the mains
supply.
u
Work on electrical components must only be
conducted by trained electrical personnel.
u
A damaged power supply cable must be replaced
by a suitable power supply cable.
öWARNING
Risk of injury or damage from improper repairs
Incorrect components can lead to personal injury or
damage to the appliance. Modifications, additions or
alterations to the appliance can lead to safety risks.
u
Only use original spare parts for repairs.
u
Do not make any modifications, additions or
alterations to the appliance.
CAUTION
Risk of injury during repair of gas appliances
Insufficient expertise can lead to injury when
disassembling the appliance.
u
The gas connection must only be worked on by
reliable trained specialists who are familiar with
and comply with the standard national
regulations and supplementary regulations of the
local utility companies.
Safety
EN
8bora.com
2.5
Safety instructions –
disassembly and disposal
öDANGER
Risk of injury during disassembly
Insufficient expertise can lead to injury when
disassembling the appliance.
u
It must only be disassembled by trained
specialists who are familiar with and comply with
the standard national regulations and
supplementary regulations of the local utility
companies.
u
Safely disconnect the appliance from the mains
supply.
u
Work on electrical components must only be
conducted by trained electrical personnel.
öDANGER
Risk of electric shock from incorrect
disconnection
Incorrectly disconnecting the appliance from the
mains results in a risk of electric shock.
u
Safely disconnect the appliance from the mains
supply.
u
Use an authorised measuring device to ensure
that there is no power to the appliance.
u
Do not touch exposed contacts on the electronic
unit as they may contain residual charge.
öDANGER
Risk of electric shock from residual charge
Electrical components in the appliance can contain
residual charge and cause an electric shock.
u
Do not touch any exposed contacts.
CAUTION
Risk of injury during disassembly of gas
appliances
Insufficient expertise can lead to injury when
disassembling the appliance.
u
The gas connection must only be worked on by
reliable trained specialists who are familiar with
and comply with the standard national
regulations and supplementary regulations of the
local utility companies.
Technical data EN
bora.com 9
3
Technical data
3.1
Cooktop extractor PKA3/
PKA3AB
Parameter Value
Supply voltage 220–240V
Frequency 50–60 Hz
Power consumption (incl. additional universal
fans)
550 W
Dimensions (width x depth x height) 482 x 540 x 176 mm
Weight (incl. accessories and packaging) 9.25kg
Cooktop extractor
Power levels 1–9, P
Tab.3.1 Technical data for PKA3/PKA3AB
PKA3/PKA3AB appliance dimensions
Fig.3.1 PKA3/PKA3AB appliance dimensions from above
Fig.3.2 PKA3/PKA3AB appliance dimensions front view
Fig.3.3 PKA3/PKA3AB appliance dimensions side view
Fig.3.4 Control unit dimensions
3.2
Cooktop extractor system with
integrated fan PKAS3/
PKAS3AB
Parameter Value
Supply voltage 220–240V
Frequency 50–60 Hz
Power consumption (incl. additional universal
fans)
550 W
Dimensions (width x depth x height) 468 x 540 x 199mm
Weight (incl. accessories and packaging) 12.5kg
Cooktop extractor
Power levels 1–9, P
Tab.3.2 Technical data for PKAS3/PKAS3AB
Technical data
EN
10 bora.com
PKAS3/PKAS3AB appliance dimensions
Fig.3.5 PKAS3/PKAS3AB appliance dimensions from above
Fig.3.6 PKAS3/PKAS3AB appliance dimensions front view
Fig.3.7 PKAS3/PKAS3AB appliance dimensions side view
3.3
Surface induction cooktop
PKFI3
Parameter Value
Supply voltage 220–240V
Frequency 50–60 Hz
Power consumption 3680 W
Fuse protection 1 x 16A
Cooktop dimensions 370 x 540 x 52 mm
Weight (incl. accessories and packaging) 8.1kg
Cooktop
Power levels 1–9, P
Heat retention levels 3
Front cooking zone size 230 x 230 mm
Front cooking zone output 2100 W
Front cooking zone power setting output 3680 W
Rear cooking zone size 230 x 230 mm
Rear cooking zone output 2100 W
Rear cooking zone power setting output 3680 W
Power consumption (calculated with standard pot sizes)
Front cooking zone (150 mm) 185.0Wh/kg
Rear cooking zone (180 mm) 176.5Wh/kg
Cooking zones bridged (210 mm) 204.4Wh/kg
Total (average) 188.6Wh/kg
Tab.3.3 Technical data for PKFI3
PKFI3 appliance dimensions
Fig.3.8 PKFI3 appliance dimensions from above
Technical data EN
bora.com 11
Fig.3.9 PKFI3 appliance dimensions front view
Fig.3.10 PKFI3 appliance dimensions side view
3.4
Induction cooktop PKI3
Parameter Value
Supply voltage 220–240V
Frequency 50–60 Hz
Power consumption 3680 W
Fuse protection 1 x 16A
Cooktop dimensions 370 x 540 x 52 mm
Weight (incl. accessories and packaging) 8.0kg
Cooktop Value
Power levels 1–9, P
Heat retention levels 3
Front cooking zone size Ø 230 mm
Front cooking zone output 2300 W
Front cooking zone power setting output 3680 W
Rear cooking zone size Ø 165 mm
Rear cooking zone output 1400 W
Rear cooking zone power setting output 2200 W
Power consumption (calculated with standard pot sizes)
Front cooking zone (240 mm) 162.7Wh/kg
Rear cooking zone (180 mm) 169.3Wh/kg
Total (average) 166.0Wh/kg
Tab.3.4 Technical data for PKI3
PKI3 appliance dimensions
Fig.3.11 PKI3 appliance dimensions from above
Fig.3.12 PKI3 appliance dimensions front view
Fig.3.13 PKI3 appliance dimensions side view
3.5
Induction wok cooktop PKIW3
Parameter Value
Supply voltage 220–240V
Frequency 50–60 Hz
Power consumption 3000 W
Fuse protection 1 x 16A
Cooktop dimensions 370 x 540 x 128 mm
Weight (incl. accessories and packaging) 9.5kg
Cooktop
Power levels 1–9, P
Heat retention levels 3
Cooking zone size Ø 310 mm
Cooking zone output 2400 W
Cooking zone power setting output 3000 W
Tab.3.5 Technical data for PKIW3
Technical data
EN
12 bora.com
PKIW3 appliance dimensions
Fig.3.14 PKIW3 appliance dimensions from above
Fig.3.15 PKIW3 appliance dimensions front view
Fig.3.16 PKIW3 appliance dimensions side view
3.6
HiLight cooktop, 3-ring/2-ring
PKC3
Parameter Value
Supply voltage 380–415 V 2N~
Frequency 50–60 Hz
Power consumption 4400 W
Fuse protection 2 x 16A
Cooktop dimensions 370 x 540 x 73 mm
Weight (incl. accessories and packaging) 8.7kg
Cooktop
Power levels 1–9, 2-ring, 3-ring
Heat retention levels 3
Front cooking zone size Ø 120 mm
Front cooking zone output 800 W
Front cooking zone 2-ring additional switching
size
Ø 180 mm
Front cooking zone 2-ring additional switching
output
1600 W
Front cooking zone 3-ring additional switching
size
Ø 235 mm
Front cooking zone 3-ring additional switching
output
2500 W
Rear cooking zone size Ø 120 mm
Rear cooking zone output 800 W
Rear cooking zone 2-ring additional switching
size
Ø 200 mm
Rear cooking zone 2-ring additional switching
output
1900 W
Power consumption (calculated with standard pot sizes)
Front cooking zone (240 mm) 180.1Wh/kg
Rear cooking zone (210 mm) 189.0Wh/kg
Total (average) 184.6Wh/kg
Tab.3.6 Technical data for PKC3
Technical data EN
bora.com 13
PKC3 appliance dimensions
Fig.3.17 PKC3 appliance dimensions from above
Fig.3.18 PKC3 appliance dimensions front view
Fig.3.19 PKC3 appliance dimensions side view
3.7
HiLight cooktop, 3-ring/
roaster PKCB3
Cooktop Value
Supply voltage 380–415 V 2N~
Frequency 50–60 Hz
Power consumption 5100 W
Fuse protection 2 x 16A
Cooktop dimensions 370 x 540 x 73 mm
Weight (incl. accessories and packaging) 8.9kg
Cooktop
Power levels 1–9, 2-ring, 3-ring,
roaster
Heat retention levels 3
Front cooking zone size Ø 120 mm
Front cooking zone output 800 W
Front cooking zone 2-ring additional switching
size
Ø 180 mm
Front cooking zone 2-ring additional switching
output
1600 W
Front cooking zone 3-ring additional switching
size
Ø 235 mm
Front cooking zone 3-ring additional switching
output
2500 W
Rear cooking zone size Ø 165 mm
Rear cooking zone output 1500 W
Cooking zone roaster additional switching size 290 x 165 mm
Cooking zone roaster additional switching
output
2600 W
Power consumption (calculated with standard pot sizes)
Front cooking zone (240 mm) 180.6Wh/kg
Rear cooking zone (180 mm) 189.5Wh/kg
Total (average) 185.1Wh/kg
Tab.3.7 Technical data for PKCB3
Technical data
EN
14 bora.com
PKCB3 appliance dimensions
Fig.3.20 PKCB3 appliance dimensions from above
Fig.3.21 PKCB3 appliance dimensions front view
Fig.3.22 PKCB3 appliance dimensions side view
3.8
Hyper cooktop, 1-ring/2-ring
PKCH3
Parameter Value
Supply voltage 380–415 V 2N~
Frequency 50–60 Hz
Power consumption 5100 W
Fuse protection 2 x 16A
Cooktop dimensions 370 x 540 x 73 mm
Weight (incl. accessories and packaging) 8.7kg
Cooktop
Power levels 1–9, Hyper level, 2-ring
additional switching
Heat retention levels 3
Front cooking zone size Ø 235 mm
Front cooking zone output 2100 W
Hyper level output 3200 W
Rear cooking zone size Ø 120 mm
Rear cooking zone output 800 W
Rear cooking zone 2-ring additional switching
size
Ø 200 mm
Rear cooking zone 2-ring additional switching
output
1900 W
Power consumption (calculated with standard pot sizes)
Front cooking zone (240 mm) 175.9Wh/kg
Rear cooking zone (210 mm) 189.1Wh/kg
Total (average) 182.5Wh/kg
Tab.3.8 Technical data for PKCH3
PKCH3 appliance dimensions
Fig.3.23 PKCH3 appliance dimensions from above
Technical data EN
bora.com 15
Fig.3.24 PKCH3 appliance dimensions front view
Fig.3.25 PKCH3 appliance dimensions side view
3.9
Tepan stainless steel grill PKT3
Parameter Value
Supply voltage 380–415 V 2N~
Frequency 50–60 Hz
Power consumption 4800 W
Fuse protection 2 x 16A
Cooktop dimensions 370 x 540 x 73 mm
Weight (incl. accessories and packaging) 15.8kg
Cooktop
Temperature control (power levels) 80–250°C (250°C = P)
Front cooking zone size 295 x 230 mm
Front cooking zone output 2400 W
Rear cooking zone size 295 x 230 mm
Rear cooking zone output 2400 W
Temperature control range 70 - 250 °C
Tab.3.9 Technical data for PKT3
PKT3 appliance dimensions
Fig.3.26 PKT3 appliance dimensions from above
Fig.3.27 PKT3 appliance dimensions front view
Fig.3.28 PKT3 appliance dimensions side view
Technical data
EN
16 bora.com
3.10
Gas cooktop PKG3
Parameter Value
Supply voltage 220–240V
Frequency 50–60 Hz
Total burner output 5000 W
Power rating 20 W
Fuse protection 1 x 0.5 A
Gas connection 1/2” internal thread
Cooktop dimensions 370 x 540 x 73 mm
High-power burner pan support dimensions 270 x 270 x 25/50 mm
Normal burner pan support dimensions 235 x 235 x 25/50 mm
Weight (incl. accessories and packaging) 11.5 kg
Cooktop
Power levels 1–9, P
Heat retention levels 3
High-power burner 800–3000W
Normal burner 550–2000W
Total nominal connection values
G20/20mbar:
5000 W | 0.449 m³/h
Cooktop energy consumption G20/20mbar
High-power burner 60.0%
Normal burner 60.0%
Cooking zones bridged 60.0%
Tab.3.10 Technical data for PKG3
PKG3 appliance dimensions
Fig.3.29 PKG3 appliance dimensions from above
Fig.3.30 PKG3 appliance dimensions front view
Fig.3.31 PKG3 appliance dimensions side view
3.11
Control knob
Parameter Value
Dimensions (width x depth x height) Ø 49 mm x 92 mm
Tab.3.11 Technical data for control knob
Control knob dimensions
Fig.3.32 Control knob
Fig.3.33 Control knob dimensions
Installation EN
bora.com 17
4
Installation
u
Observe all safety and warning information (see"2Safety").
u
Follow the enclosed manufacturer’s information.
4.1
General installation
instructions
The appliance must not be installed above cooling devices,
dishwashers, stoves, ovens, washing machines or dryers.
The contact surface of the worktops and wall sealing strips
must be made of a heat-resistant material (up to approx.
100°C).
Worktop cut-outs must be moisture-sealed using suitable
means and, where necessary, fitted with a thermal insulator.
External devices may only be connected to the cooktop
extractor connections provided.
Extremely bright lights aimed directly at the appliances can
cause colour variations in the appliances and are thus to be
avoided.
General installation instructions for cooktops
u
Make sure that the area below the cooktop has a sufficient air
supply.
To ensure that the cooktops perform optimally at all times,
there must be sufficient ventilation beneath the cooktops.
The performance of the cooktops is affected or the cooktops
overheat if the warm air beneath the cooktops cannot escape.
In the event of overheating, the cooktop power is reduced or
the appliance is switched off completely.
If cable protection (false floor) is planned beneath the
appliance, this must be fitted so it does not obstruct
ventilation.
Additional installation instructions for Australia and New
Zealand (AU/NZ):
The gas hose must be checked every 5 years and replaced if
necessary. The gas hose must meet the requirements of AS/
NZS 1869.
Restricted functions when using the cooktops without a
cooktop extractor
If cooktops are installed and operated without a cooktop extractor,
only limited functions will be available. The following functions will not
be available:
T
System functions
T
Pause function
T
Short-time timer
T
Child lock
T
All settings/functions in the configuration menu
4.1.1
Operating the cooktop extractor in
the exhaust air mode and where
there is a fireplace dependent
upon the air supply in the room
National and regional laws and regulations must be observed
with regard to the exhaust duct design.
A sufficient air supply must be ensured.
Fireplaces that depend on the air in the room (e.g. gas, oil, wood or
coal-fired heaters, continuous-flow water heaters, instantaneous
water heaters) draw in air from the room in which they are installed
and release the exhaust fumes into the outside air via an exhaust
system (e.g. chimney).
If the cooktop extractor is used in exhaust air mode, it draws in air
from the room in which it is installed as well as from neighbouring
rooms. Without sufficient air, there will be a drop in air pressure.
Toxic gases could be drawn out of the chimney or extraction ducting
and back into the room.
Fig.4.1 Exhaust air installation – not permitted
Fig.4.2 Exhaust air installation – correct
u
If simultaneously operating both a fireplace and the cooktop
extractor in the same room, ensure that:
T
the maximum low pressure is 4Pa (4 x 10–5bar);
T
a safety device (e.g. window contact switch, low pressure warning
device) is used to ensure that a sufficient supply of fresh air is
guaranteed;
T
the exhaust air is not channelled into a chimney that is used for
exhaust gases of appliances operated with gas or other
combustibles;
T
the installation is checked and approved by an authorised certified
engineer (e.g. heating engineer).
Installation
EN
18 bora.com
T
when using a window contact switch, only devices will be installed
which meet the requirements of standard IEC 60730-1:2013 +
AMD1:2015 or EN 60730-1:2016 (or a more recent IEC update or
EN standard) for type 2 control units and devices (e.g. window
contact switch UFKS).
No window contact switches may be installed that separate
the control unit from the power supply (phase separation).
Only the Home In interface is to be used
If the cooktop extractor is used exclusively in recirculation
mode, operation with an open fireplace is possible without
any additional safety measures.
4.2
Checking the scope of delivery
Checking the scope of delivery
u
Make sure the delivery is complete and check it for damage.
u
Immediately inform the BORA Service TeamTeam if parts are
missing or damaged.
u
Do not under any circumstances install parts which are damaged.
u
Dispose of transport packaging in the proper manner
(see"5Decommissioning, disassembly and disposal").
4.2.1
Scope of delivery of the cooktop
extractor
Scope of delivery Quantity
Operating instructions 1
Installation instructions 1
Cooktop extractor 1
Height adjustment plate set 1
Installation clamps 4
Control knob 1
Stainless steel grease filter 1
Filter tray 1
Maintenance tray 1
Cover flap 1
Power supply cable 1
Control knob cable 1
Additional scope of delivery for PKA3/PKA3AB
CAT 5e communication cable 1
Control unit 1
Duct piece 1
Seal 1
Tab.4.1 Scope of delivery
4.2.2
Scope of delivery of the cooktops
Scope of delivery Quantity
Operating instructions 1
Installation instructions 1
Cooktop 1
Height adjustment plate set 1
Fixing screws 4
Mounting brackets 4
Control knob 2
Control knob cable 2
Cooktop-to-cooktop-extractor communication cable 1
Additional scope of delivery for Tepan
Tepan spatula 1
Additional scope of delivery for gas cooktop
Cast-iron pan support 2
Nozzle set G20/20mbar natural gas PKGDS2020 1
Cylindrical/conical transition piece 1
Seal 1
Additional scope of delivery for Australia and New
Zealand:
1.00 kPa gas regulator with test-point adapter for
natural gas (NG)
1
Flexible gas connection hose, length 500 mm, 1/2”
external thread (AS/NZS 1869)
1
Test-point adapter for liquified petroleum gas (LPG) 1
G20/10 mbar nozzle set (NG/1.0 kPa) – pre-installed 1
G31/27.5 mbar nozzle set (ULPG/2.75 kPa) 1
Tab.4.2 Scope of delivery
4.3
Tools and aids
The following tools, among others, are required to correctly install the
cooktop:
T
pencil
T
tape measure or folding metre stick
T
conventional or battery-operated drill
T
Ø50mm centre bit
T
black, heat-resistant silicone sealant
T
slotted screwdriver
T
size 10 Torx screwdriver/key
T
size 20 Torx screwdriver key
Installation EN
bora.com 19
4.4
Assembly instructions
4.4.1
Installation clearances
u
Observe the required clearance around the worktop cut-out.
1
2
*
Fig.4.3 Required clearance
[1] Required clearance
[2] Worktop cut-out
[*] 650 mm in the case of gas cooktops
4.4.2
Minimum installation dimensions
Fig.4.4 Minimum installation dimensions for standard set-up of
PKA3/PKA3AB
Fig.4.5 Appliance installation dimensions for standard set-up of
PKA3/PKA3AB with round silencer
4.4.3
Worktop
u
Create the worktop cut-out taking into account the specified cut-
out dimensions.
u
Make sure that the cut surfaces of the worktops are properly
sealed.
u
Comply with the instructions of the worktop manufacturer.
4.4.4
Kitchen units
T
Cross bars on the kitchen unit in the area of the worktop cut-out
may need to be removed.
T
No false floor is necessary below the cooktop. If cable protection
(false floor) is planned, the following must be taken into account:
T
It must be able to be removed for maintenance work.
T
To ensure sufficient cooktop ventilation, a minimum distance
of 15 mm to the bottom edge of the cooktop extractor is to be
observed.
T
The drawers and/or shelves in the floor unit must be removable.
T
For correct installation, the drawers of the floor unit must be
shortened depending on the installation situation.
4.4.5
Special assembly instructions for
the gas cooktop
Taking into account the applicable valid regulations, the
cooktop must be connected to the gas line with an upstream
stopcock.
The connection between the gas cooktop and the gas
connection must be provided at the installation site.
Installation
EN
20 bora.com
The hose connection must be laid in such a way that it is not
subject to deformation, buckling or abrasion.
The stopcock and gas supply pipe connections must be
accessible.
The pressure regulator must correspond to the set gas type
and set gas pressure and must meet local and legal
requirements.
The gas connection hose line must not come into contact with
smoke or the flue outlet of an oven.
The hose line must not come into contact with hot surfaces
on the cooktop or other devices.
Positioning of the gas cooktop with two cooktop
extractors
If the gas cooktop is used in a model with two cooktop extractors, it
is to be installed at the side. If installed between the cooktop
extractors, the pull of air on both sides may affect the flames.
Fig.4.6 Positioning of the gas cooktop with two cooktop extractors
Air supply for the gas cooktop
To ensure a sufficient air supply, an opening cross-section of at least
50cm² is required in the front of the kitchen unit, or an opening
cross-section of at least 150cm² in the plinth area.
u
Make sure that the area below the cooktop has a sufficient air
supply.
1 2
Fig.4.7 Air supply at front of the unit
[1] Air supply via the front of the unit (opening cross-section ≥50cm²)
[2] Optional cable protection (shortened)
1
2
Fig.4.8 Plinth area air supply
[1] Optional cable protection (shortened)
[2] Air supply via the plinth area (opening cross-section ≥150cm²)
4.4.6
Return flow of recirculated air
In the case of recirculation systems, a return flow aperture must be
provided in the kitchen unit to guide the clean recirculated air out of
the unit and back into the room. The return flow aperture can be
created above a shortened plinth. A slatted plinth with at least the
minimum opening cross-section can also be used.
u
Decrease the height of the plinth panel or create corresponding
openings in the plinth.
u
The cross-section of the return flow aperture must be ≥ 500cm²
(≥ 1000cm² in the case of gas appliances) for each cooktop
extractor.
/