TECHNICAL DETAILS:
DETAIL SPECIFICATION
INLET CONNECTION 1/2” FEMALE NPT †
INTEGRATED DIVERTER NO
SPOUT REACH 8-1/2” [216mm]
WATER PRESSURE RANGE 20psi [1.5 bar] MIN, 85psi [6.0 bar] MAX
WATER PRESSURE RECOMMENDED 45psi [3.0 bar]
ROUGH-IN:
¾Determine the ideal location for the TUB SPOUT and rough-in a well supported 1/2” NPT
NIPPLE (not supplied) of appropriate length.
REGULATOR WALL MOUNTED TUB SPOUT
STYLES
RGTS01
IMPORTANT:
¾To ensure this product is installed properly, you must read and follow
these guidelines.
¾The owner/user of this product must keep this information for future
reference.
¾This product must be installed by a professional licensed contractor
and must be on-site prior to rough-in. This allows the installer to
visualize the installation.
¾Check TUB measurements to assure the SPOUT projects far enough
into the TUB.
¾Be sure your installation conforms to all federal, state, and local
codes.
Anti-scald protection is the responsibility of the installer and
according to applicable codes.
A water temperature limiting device is the responsibility of the
installer and must be in accordance with ASSE 1070.
In the State of Massachusetts, all installations must comply with
the rules and regulations set forth within 248 CMR.
¾Inspect this product to ensure it is the correct model and you have
all the parts required for proper installation.
¾Product is sold partially assembled but shown fully disassembled
for illustrative and service purposes only.
¾Use only a strap wrench or protected/smooth-jaw wrench on any
finished surface.
¾The use of certain plumber’s putty may stain stone or tile surfaces.
¾If further assistance is required, please contact Product Support at
1-800-927-2120 Monday through Friday, 8am – 6pm EST.
¾Refer to the separate Service Parts Documents for available
replacement parts.
FINISHED
WALL
"A"
FITTINGS
HOLE
"B"
FRONT FACE OF NIPPLE
IN FRONT OF FINISHED WALL
DIMENSION VALUE
A 1-1/4” [32mm]
B 5/8” [16mm]
For INTERNATIONAL USE ONLY,
A 1/2” Male NPT x 1/2” Male BSPP ADAPTER for the SPOUT is provided. The BSPP end
of the ADAPTER may be field cut.
1/2” NPT NIPPLE
[NOT SUPPLIED]
OR
1/2” BSPP ADAPTER
[SUPPLIED -
INTERNATIONAL
USE ONLY]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 2 OF 2 | UPDATED ON 11.10.2023
O-RING
ESCUTCHEON †
SCREW x 4
SPOUT
† An O-RING for the ESCUTCHEON
is provided. If desired, a bead of
caulk or a clear silicone may be
applied where the ESCUTCHEON
contacts the finished wall.
[AESTHETIC ONLY]
AERATOR TOOL
AERATOR
SPOUT
[CHECK FOR LEAKS!]
SPOUT
* TURN ON WATER
AERATOR TOOL
AERATOR
SPOUT
FINISHED WALL
1/2" NPT NIPPLE
[1/2" FEMALE
NPT INLET]
SPOUT
[NOT SUPPLIED]
[1/2" FEMALE
NPT INLET]
O-RING
ESCUTCHEON
[INTERNAL O-RINGS]
SCREW x 4
SPOUT
[AESTHETIC
ONLY]
INSTALLATION GUIDELINES
WALL MOUNTED TUB SPOUT
6. Slide the ESCUTCHEON down the SPOUT until it
contacts the finished wall.
5. Re-install the AERATOR.
NOTE: A replacement AERATOR (STYLE No.
999190) and KEY (STYLE No. 999191) can be
ordered separately.
4. Turn on the water and a diverter/wall valve (sold
separately) to flush out any debris in the supply line
and inspect all connections for leaks then turn the
water off.
3. Using the TOOL provided, remove the AERATOR. 2. Making sure the NIPPLE (not supplied) is properly
roughed-in, thread and securely tighten the SPOUT
onto the NIPPLE.
NOTE: For International installations, a BSPP
ADAPTER, which may be field cut, is provided.
1. Slide the ESCUTCHEON and O-RING onto the
SPOUT.
NOTE: Do NOT remove the 4 SCREWS on the
ESCUTCHEON. They are AESTHETIC only.
  • Page 1 1
  • Page 2 2

WaterWorks RGTS01 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI