Shaw HD83000109, HD83000405, HD83000604, HD83000717, HD83000723, HD83100559, HD83100568, HD83100769, HD83100774 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Shaw HD83000109 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATIONGUIDELINESFORVINYLPLANKANDTILE
TABLEOFCONTENTSSECTION:
1. TESTBEFORESTARTINGINSTALLATIONS
2. MATERIALSTORAGEANDHANDLING
3. SUBSTRATES
4. SHAWADHESIVES
5. INSTALLINGRESILIENTTILE&PLANKPRODUCTS
6. ARRAYGROUT
7. WARRANTY
1.TESTBEFORESTARTINGINSTALLATION
Note:Allsubstratestoreceivemoisturesensitivefloorcoveringmustbetestedformoisture.
CONCRETESUBSTRATES:
AllconcretesubstratesshouldbetestedforIRH(InternalRelativeHumidity)accordingtoASTMF2170.
CalciumChloridetestsmaybeconductedinadditiontoIRHandmustbeperformedperthelatesteditionofASTMF1869.
NEWANDEXISTINGCONCRETESUBFLOORSSHOULDMEETTHEGUIDELINESOFTHELATESTEDITIONOFACI302ANDASTMF710,“STANDARD
PRACTICEFORPREPARINGCONCRETEFLOORSTORECEIVERESILIENTFLOORING”AVAILABLEFROMTHEAMERICANSOCIETYFORTESTINGAND
MATERIALS,100BARRHARBORDRIVE,WESTCONSHOHOCKEN,PA19428;6108329585;HTTP://WWW.ASTM.ORG.
a. Substratesshallbesmooth,structurallysound,permanentlydry,cleanandfreeofallforeignmaterialsuchasdust,wax,solvents,paint,
grease,oils,oldadhesiveresidue,curingandhardening/curingcompounds,sealersandotherforeignmaterialthatmightprevent
adhesivebond.
b. Concretefloorsshallbeflatandsmoothwithin
1/8"in6feetor3/16”in10feet.
c. FNumberSystem:OverallvaluesofFF36/FL20maybeappropriateforresilientfloorcoverings.
d. ASTMF2170IRH(InternalRelativeHumidity)arerequiredfortheShawwarranty.Threetestsmustbeconductedforareasupto
1000SF,
andoneadditionaltest,foreachadditional1000SF.
e. MoistureVaporEmission Rate(MVER)
200&KwikflashAdhesive‐maynotexceed85%RH.
S150&4100Adhesive‐maynotexceed90%RH.
f. UseonlyPortlandbasedpatchingandlevelingcompounds.DonotinstallShawresilient
flooringovergypsumbasedpatching
and/orlevelingcompounds.
g. PerformBondtestingtodeterminecompatibilityofadhesivetothesubstrate.Shaw9050primercanbeutilizedtopromoteadhesion.
h. Workingandopentimesofadhesivesmayvarybasedonjobconditions,substrate,temperature,andhumidity.
i. Areastoreceive
flooringshouldbeadequatelylightedduringallphasesoftheinstallationprocess.
j. Itisrecommendedthatresilientfloorcoveringinstallationshallnotbeginuntilallothertradeshavecompleted.
TEMPERATURE‐AMBIENT:
a. Controlledenvironmentsarecritical.FullyfunctionalHVACsystemsarethebestwaytoensuretemperatureandhumidity
control.
DONOTinstallresilientflooringproductsuntiltheworkareacanbetemperaturecontrolled.
ThepermanentHVACsystemturnedonandsettoaminimumof65°F(20°C)oramaximumof85°F,foraminimumof7days
priorto,during,andafterinstallation.Oncetheinstallation
iscompletethe temperatureshouldnotexceed85°F.
PH:
a. ConcretefloorsmustbetestedperthelatesteditionofASTMF710.
PHreadingmustnotexceed9.0.
Readingsbelow5.0andinexcessof9.0affectresilientflooringandadhesivesnegatively.
Rinsingthesurfacewith
clearwatermayloweralkalinity.“DAMPMOP”
Shaw9050anacrylicsolutioncanbeutilizedtocorrecthighPHreadings.
NOTE:ITMAYNOTBETHEFLOORCOVERINGINSTALLER’SRESPONSIBILITYTOCONDUCTTHESETESTS.ITIS,HOWEVER,THEFLOORCOVERING
INSTALLER’SRESPONSIBILITYTOMAKESURETHESETESTSHAVEBEENCONDUCTED,ANDTHATTHERESULTSAREACCEPTABLEPRIORTO
INSTALLINGTHEFLOORCOVERING.WHENMOISTURETESTSARECONDUCTED,ITINDICATESTHECONDITIONS
ONLYATTHETIMEOFTHETEST.
2.MATERIALSTORAGEANDHANDLING:
a. Flooringmaterialandadhesivemustbeacclimatedtotheinstallationareaforaminimumof48hours priortoinstallation.
b. Storecartonsoftileorplankproductsflatandsquarelyontopofoneanother.Tile
orplankproductsshouldbestackednomorethan6
highandallowforairflowaroundstackswhenunpalletized.Preferably,locatematerialinthe“center”oftheinstallationarea(i.e.away
fromvents,directsunlight,etc.)Storingcartonsindirectsunlightmayaffectproperacclimationbyinducingthermal
expansion/contraction.
c. Whenpalletizingonajobsitevinylplankortilesneedtobestacked2rowshighsidebysidewithnoairspacebetween.Thenquarter
turnedfor2rowssidebyside,nottoexceed12boxeshigh.A5/8”orthickerplywoodmustalsobeplacedonthe
palletfirst.
d. Donotstackpallet’s2highunlessutilizinga1”thickplywoodinbetweenpallets.
3.SUBSTRATES:
Note:Allsubstratestoreceiveresilientflooringshallbedry,clean,smoothandstructurallysound.Theyshallbefreeofdust,solvent,paint,
wax,oil,grease,residualadhesive,adhesiveremovers,curing,sealing,hardening/partingcompounds,alkalinesalts,excessive
carbonation/laitance,mold,mildew,andotherforeignmaterialsthatmightpreventtheadhesive
frombonding.
WOODSUBSTRATES:
Woodsubfloorsmustbestructurallysoundandincompliancewithlocalbuildingcodes.
a. DoubleLayeredAPAratedplywoodsubfloorsshouldbeaminimum1"totalthickness,withatleast18"wellventilatedairspacebeneath.
b. Insulateandprotectcrawlspaceswithavaporbarriercoveringtheground.
c. DONOTinstalloversleeperconstructionsubfloorsorwoodsubfloorsapplieddirectlyoverconcrete.
d. Underlaymentpanelscanonlycorrectminordeficienciesinthesubfloorwhileprovidingasmooth,soundsurfaceonwhichtoadherethe
resilientflooring.
e. Anyfailuresintheperformanceoftheunderlaymentpanel
restwiththepanelmanufacturerandnotwithShawIndustries,Inc.
f. ItisrecommendedthatyourchosenAPAunderlaymentgradepanelsbedesignedforinstallationunderresilientflooring,andcarrya
writtenwarrantycoveringreplacementoftheentireflooringsystem.
g. SHAWresilientflooringisnotrecommendeddirectlyoverfire
retardanttreatedplywoodorpreservativetreatedplywood.
h. Thematerialsusedtotreattheplywoodmaycauseproblemswithadhesivebonding.AnadditionallayerofAPArated1/4"thick
underlaymentshouldbeinstalled.
i. Alwaysfollowtheunderlaymentmanufacturer’sinstallationinstructions.
STRIPPLANKWOODFLOORING:
Duetoexpansion/contractionofindividualboardsduringseasonalchanges,SHAWrecommends1/4"orthickerAPAratedunderlaymentpanelsbe
installedoverthesetypesofsubfloors.
CONCRETE:
NeworexistingconcretesubfloorsmustmeettheguidelinesofthelatesteditionofACI302andASTMF710,“StandardPracticeforPreparing
ConcreteFloorstoReceiveResilientFlooring”.
a. Onorbelowgradeslabsmusthaveaneffectivevaporretarderdirectlyundertheslab.
b. Wetcuring7
daysisthepreferredmethodforcuringnewconcrete.
c. Curingcompounds(DONOTUSE).Ifpresenttheycaninterferewiththebondoftheadhesivetotheconcrete.Seekassistancefroma
substratemanufacturerifcuringagentsaredetected.
d. Removecuringcompounds28daysafterplacement,soconcrete
canbegindrying.
e. Concretefloorsshallbeflatandsmoothwithin1/8"in6feetor3/16”in10feet.
f. FNumberSystem:OverallvaluesofFF36/FL20maybeappropriateforresilientfloorcoverings.
g. AdhesiveMoisturevaporemissionmaynotexceed87%RH(Shaw4100)
or90%(ShawS150).
Note:PerformBondtestingtodeterminecompatibilityofadhesivetothesubstrate.Shaw9050primercanbeutilizedtopromoteadhesion.
Expansionjointsinconcretearedesignedtoallowfortheexpansionandcontractionoftheconcrete.Resilientflooringproductsshouldneverbe
installedoverexpansion
joints.Expansionjointcoversdesignedforusewithresilientflooringsshouldbeused.Controljoints(sawcuts)maybe
patchedandcoveredwithresilientoncetheconcreteisthoroughlycured,dryandacclimated.
LIGHTWEIGHTCONCRETE
Allrecommendationsandguaranteesastothesuitabilityandperformanceoflightweightconcreteunderresilientflooringaretheresponsibilityof
thelightweightconcretemanufacturer.Theinstallerofthelightweightproductmayberequiredtobeauthorizedorcertifiedbythemanufacturer.
Correctonsitemixingratiosandproperlyfunctioning
pumpingequipmentarecritical.Toensurepropermixture,slumptestingisrecommended.
a. Lightweightaggregateconcreteshavingdensitiesgreaterthan90lbs.percubicfootmaybeacceptableunderresilientflooring.
b. Concreteslabswithheavystaticand/ordynamicloadsshouldbedesignedwithhigherstrengthsanddensitiestosupport
suchloads.
c. Surfacemustbepermanentlydry,clean,andsmooth,freeofalldust,andstructurallysound.
d. PerformBondtestingtodeterminecompatibilityofadhesivetothesubstrate.Shaw9050primercanbeutilizedtopromoteadhesion.
RadiantHeat:HydronicOnly
Radiantheatedsubstratesmustnotexceed85°F(29°C)surfacetemperature.
a. Sevendayspriortoinstallingresilientproductsovernewlyconstructedradiantheatedsystems,makesuretheradiantsystemhasbeen
onandoperatingatmaximumtemperaturetoreduceresidualmoisturewithintheconcrete.
b. Threedays
priortoinstallationlowerthetemperatureto65°F.24hoursafterinstallation,graduallyincreasethetemperaturein
incrementsof5°Ftoavoidoverheating.
c. Aftercontinuousoperationoftheradiantsystem,ensurethesurfaceofthefloordoesnotexceed85°F(29°C)
d. Useofaninfloortemperaturesensor
isrecommendedtoavoidoverheating.
WARNING!DONOTSAND,DRYSWEEP,DRYSCRAPE,DRILL,SAW,BEADBLASTORMECHANICALLYCHIPORPULVERIZEEXISTINGRESILIENT
FLOORING,BACKING,LININGFELT,ASPHALTIC“CUTBACK”ADHESIVESOROTHERADHESIVES.Theseproductsmaycontaineitherasbestosfibers
and/orcrystallinesilica.Avoidcreatingdust.Inhalationofsuchdustisacancerandrespiratorytracthazard.Smokingbyindividualsexposedto
asbestosfibersgreatlyincreasestheriskofserious bodilyharm.Unlesspositivelycertainthattheproductisanonasbestoscontainingmaterial,
youmustpresumeitcontainsasbestos.Regulationsmayrequirethatthematerialbetestedtodetermineasbestoscontentandmaygovernthe
removalanddisposalofmaterial.SeecurrenteditionoftheResilientFloorCovering Institute(RFCI)publicationRecommendedWorkPracticesfor
RemovalofResilientFloorCoveringsfordetailedinformationandinstructionsonremovingallresilientcoveringstructures.Forcurrent
informationgotowww.rfci.com
RESILIENTFLOORCOVERING:
a. Mustbesinglelayered,noncushionbacked,fullyadhered,andsmooth.
b. Shownosignsofmoistureoralkalinity.
c. Waxes,polishes,grease,grime,andoilmustberemoved.
d. Cuts,cracks,gouges,dentsandotherirregularitiesintheexistingfloorcoveringmustberepairedorreplaced.
e. Embossinglevelerrecommendedtoaidinproperbondingandtopreventtelegraphing.
f. Donotinstalloverrubberbasedsubstrates.
NOTE:THERESPONSIBILITYOFDETERMININGIFTHEEXISTINGFLOORINGISSUITABLETOBEINSTALLEDOVERTOPOFWITHRESILIENT,RESTS
SOLELYWITHINSTALLER/FLOORINGCONTRACTORONSITE.IFTHEREISANYDOUBTASTOSUITABILITY,THEEXISTINGFLOORINGSHOULDBE
REMOVED,ORANACCEPTABLEUNDERLAYMENTINSTALLEDOVERIT.INSTALLATIONSOVEREXISTINGRESILIENT
FLOORINGMAYBEMORE
SUSCEPTIBLETOINDENTATION.
QuarryTile,Terrazzo,CeramicTile,PouredFloors(Epoxy,Polymeric,Seamless):
a. Mustbetotallycuredandwellbondedtotheconcrete.
b. Mustbefreeofanyresidualsolventsandpetroleumderivatives.
c. Waxes,polishes,grease,grime,andoilmustberemoved.
d. Shownosignsofmoistureoralkalinity.
e.
Cuts,cracks,gouges,dents,andotherirregularitiesintheexistingfloorcoveringmustberepairedorreplaced.
f. Fillanylowspots,holes,chipsandseamsthatmaytelegraphthroughthenewflooring.
g. Grindanyhighlypolishedorirregular/smoothsurfaces.
QuarrytileorCeramictilegroutjointsandtextured
surfacesmustbefilledwithanembossinglevelerorsubstratemanufacturer
approvedmaterial.
OldAdhesiveResidue:
a. Iftheadhesiveresidueisasphaltbased(cutback),oranyothertypeofadhesiveispresent,itmustbedealtwithinoneoftwoways:
1. Itmaybemechanicallyremovedsuchas:beadblastingorscarifying
2. AselflevelingPortlandbasedunderlaymentmay
beappliedoverit.Checkwithasubstratemanufacturerforsuitability,
applicationinstructions,andwarranties.
b. Neverusesolventsorcitrusadhesiveremoverstoremoveoldadhesiveresidue.Solventresidueleftin/onthesubfloormayaffectthe
newadhesiveandfloorcovering.
WARNING:SKIMCOATINGOVEROLDADHESIVEISNOTRECOMMENDED.THEADHESIVEMAYBREAKDOWNANDCOULDLEADTOFAILURE.THE
OLDADHESIVEMAYNOTALLOWTHERESILIENTFLOORINGTORETAINITSDIMENSIONALSTABILITY,POSSIBLYLEADINGTOUNNECESSARY
INDENTATIONS.SOMESOLVENTBASED‘CUTBACK’ASPHALTBASEDADHESIVESMAYCONTAINASBESTOSFIBERSTHAT
ARENOTREADILY
IDENTIFIABLE.DONOTUSEPOWERDEVICES,WHICHCANCREATEASBESTOSDUSTINREMOVINGTHESEADHESIVES.THEINHALATIONOF
ASBESTOSDUSTMAYCAUSEASBESTOSISOROTHERSERIOUSBODILYHARM.
4.SHAWADHESIVES&PRIMER
Refertoadhesivelabelforpropertrowelrequirements,spreadratesandapplication.
Priortoapplicationofadhesivedetermineifthesubstrateisaporousornonporoussubstrate.Followinstructionsontheadhesivelabelforporous
ornonporoussubfloor.
IMPORTANT:Recommendedtoperformabondtestinordertodetermineadhesiveworkingtimeperjobsiteconditions.Thestrengthofthe
bondtest
willindicatewhetherShaw9050floorprimerisnecessary.
5.INSTALLINGRESILIENTTILE&PLANKPRODUCTS
General:
a. Ensurethatmoisturetestshavebeenconductedandthattheresultsdonotexceedtheacceptablemoisturelimitfortheadhesiveused.
b. PHofconcretesubfloorneedstobebetween5&9.
c. ThepermanentHVACsystemisturnedonandsettoaminimumof65°F(20°C))oramaximumof85°F,foraminimumof72hoursprior
to,duringandafterinstallation.Aftertheinstallations,themaximumtemperatureshouldnotexceed85°F.
d. Donotstackmorethan
5cartonshigh.
e. Flooringmaterialandadhesivemustbeacclimatedtotheinstallationareaforaminimumof48hourspriortoinstallation.
f. UseappropriatetrowelsizeregardingsubstrateporosityunlessusingS150SprayAdhesivewherenotrowelisrequired.
g. Materialshouldalwaysbevisuallyinspectedpriorto
installation.Anymaterialinstalledwithvisualdefectswillnotbeconsidereda
legitimateclaimasitpertainstolaborcost.
h. Installtilesrunninginsamedirection.
i. Ensurethatallrecommendationsforsubfloorandjobsiteconditionsaremetpriortobeginning theinstallation.Directionaldesignsare
optional,however,
oncetheinstallationisstarted,youhaveacceptedthoseconditions.
LAYOUTANDINSTALLATIONGENERALRULES:
a. Shawtileandplank‐Installusingconventionaltileandplankinstallationtechniques.Plankproductsshouldhaveaminimumof68"
seamstagger.
b. Carefullydeterminewheretobegintileorplankinstallation.
c. Itiscustomarytocenterroomsandhallwayssobordersarenotlessthanhalfatileorplank.
d. Workingoutofmultipleboxes atatimeisrecommended.
e. Inhallwaysand smallspaces,itmaybesimplertoworklengthwisefromoneendusingacenterreference
lineasaguide.
f. Makesurecutedgesarealwaysagainstthewall.
g. ToproperlycutLVT/LVPproductsscorethetopsideofthematerialwithautilityknife.Bendtheproductandfinishthecutthroughthe
backside.Thiswillensurethecleanestcut.Itmaybe
necessarytouseaheatguntocutaroundverticalobstructions.Allowtheheated
LVT/LVPtoreturntoroomtemperaturebeforeinstallation.
h. Cuttingtheproductintoafinepointmayleadtodelamination. UseanethylcyanoacrylatebasedsupergluetohelpfusetheLVT/LVP
pointtogether.Besureto
cleanallgluefromthetopsurfaceimmediately.Alcoholbasedsupergluesmaycausevinyltoswell.
NOTE:Recommendedtousefloorprotectionafterinstallation.DONOTuseaplasticadhesivebasedprotectionsystem.
INSTALLATIONFORTILE:
LayoutoftheRoomforSquarelyLaidFields
Tosquaretheareato
becovered,firstfindthecenterofoneendofthemainrectangle.Locatethesamepointatthe
otherendwall.Snapachalklinebetweenthesepointstomarkthecenterlineonthefloor.Thenmeasurealongthis
centerlinetofindthemiddle oftheroom.
Atthecenterpoint,markoffalineacrossthe roomatexactlyrightangles
tothefirstline.Thismaybeaccomplishedbythe345‐trianglemethodasshowninFigure 1 .Thenmeasure4feet
towardeachsidewallfromthecenterpoint.Thenmeasure3
feetfromthecenterpointalong thelongerline,
measureexactly5feetfromthe3footmarkonthecenterlinetothe4footmarkonthecrossline.Ifthe5foot
Fi
g
ure1
measurementsdonotcomeoutexactly5feet,thecentercrossinglinesarenotatatruerightangle.Forlargerooms,
multiplesoftheabovedimensionsmaybeusedtoobtaingreateraccuracy.(6810or91215,etc.)
Drylayarowoftilesfromthecenter
linetothesidewalltodeterminethespaceleftfortheborders.Iftheresulting
borderistoosmall,movethestartingpointoverahalftilewidthsothatitstraddlesthecenterline.
Repeatthesameprocedurelengthwiseofthe room.(Thiscanreadilybefiguredout
fromtheroomdimensions
withoutputtingdownthetilesifdesired.)
Figure2
Ifitisdecidedtohavethecenterrowoftilesstraddleeitherorbothofthecenterlines,additionalguidelinesshouldbesnappedonthefloor½tiles
widthononesideofeitherorbothcenterlinesasrequired.(SeeFigure2)Aftertheborderwidthshavebeendeterminedandthecenterstarting
lineshavebeensnappedspreadtherecommendedadhesiveonthecenterlinesleavingportionsofthelinesatcenterandneareachwall
uncoveredasshowninFigure3.
Spreadtheadhesiveoveronehalftheareaandafteritisready,startlayingtilefromtherightangleformedinthe
centeroftheroombycenterlines.
Laytowardthetwocornersoftheroomas shown.Alwaysrefertoyourguidelinesasyouprogresswithlayingtile
sothat
anymistakecanbecorrectedbeforeitistoolate .
Sometimesit’snecessarytocompromiseontherightnessofjointstomakeallowancesforunevennessorwavesof
thesubfloor.
Takecaretoplacetileasaccuratelyaspossiblewithoutslidingthemintoplace.Ifgroutingtilepleaseleave
appropriatespacer
betweentilesandfollowinstructionforuseofArrayGrout.
IMPORTANT:Allflooringmustbyrolledwithaminimum100lbrollerafterinstallation.Useahandrollerinareasnotreachedwitha100lb.
roller.
VERSAILLESPATTERNTILES:
TheVersaillesPattern(Frenchpattern).Properinstallationandlayoutisimportant.Thematerialmusthaveagroutlineof3mmforproper
placement.Useof3mmspacersisrequiredtoachievepropergroutlinesizeandtoensurethetilesarespacedevenly.
a. Thepatterniscomposedof
‐44%16"x16"tiles
‐33%16"x24"
tiles
‐11%8"x16"tiles
‐11%8"x8"tiles
b. InstructionsUsea3mmspacertoseparatethetilesasthepatternisconstructed.
c. Placeone8inchby8inchtileinthecenter.
d. Positiontwo16inchby16inchtileswithone
abovewheretherightedgeofthelargertileisflushwiththe
rightedgeofthesmallertile,andonetotheleftsothatthetopedgeofthesecondlargertileisflushwiththe
topedgeofthesmallertile.
e. Placeone 8inchby
16inchtileonthebottomofthesectionsothatthe8inchedgepressesagainstthe16inchsquaretileandhalfof
the16inchedgeispressedagainstthebaseedgeofthesquaretile.
f. Placea16inchby24inchtileinthecorner
createdbytherectangulartilefromStep3and thesquaretilefromStep1sothatthe16inch
edgerunshorizontally,extendingouttotherightofthestructure.
g. Positiona16inchby16inchtileimmediatelybelowthe16inchby24inchtileso
thattheleftedgeof thesquaretileispressedagainst
theshortedgeoftherectangulartile.
h. Laya16inchby24inchtilewiththe24inchsiderunninghorizontallyimmediatelytotheleftofthetilefromandpressedagainstthe
baseoftherectangulartile
andhalfofthebaseofthefirst16inchsquaretile.
i. Placean8inchsquaretileagainstthelasthalfofthebaseofthefirst16inchtileandagainsttheleftedgeofthe16inchby24inchtile.
j. Placean8inch
squaretileimmediatelyabovethefirst16inchsquaretilewitha16inchsquaretilerightabovethe8inchtile.
k. Positionan8inchby16inchtilewiththe16inchedgepressedagainstthe8inchsquaretileandtheoriginal16inchsquaretile.
l. Positionthelasttile,an8inchsquaretile,sothattherightedgeisflushwiththerightedgeofthetopright16inchby24inchtile.The8
inchtilemustbeontopofthe largerectanglewiththerightedgesflushtocompletethe
overalldesign.
7.ARRAYGROUT:
ArrayGrout,withauniqueformula,offersstainresistancecolorconsistencyandasmoothtextureforeasyspreadingandcleanup.
a. ForGroutingShawgroutabletiles.Canalsobeusedonvitreous,semivitreousorabsorptivetileincludingceramic,mosaic,quarry,
cement,porcelain,brick,
minibrick,precastterrazzoandnaturalstone.
b. Stainresistant,premixed,noshadevariance,resistsmoldandmildew.
c. Useonfloors,countertops,walls,andceilings.
Figure3
d. Forinteriorinstallationsonly.
COVERAGE:
a. 1/16“Groutjointapproximately500sqft/gallon.
b. 1/8“Groutjointapproximately300sqft/gallon.
c. 1/4“Groutjointapproximately140sqft/gallon.
LIMITATIONS:
a. ShawArrayGroutshouldnotbeinstalled,whenambienttemperatureisbelow60°Fandabove90°F.ShawArrayGroutshould
bekept
atroomtemperaturefor24hoursbeforeinstallation.
b. Sometypesofglazedceramictile,marbleandstonecanbescratched,stainedordamagedwhengroutedwithpigmentedorsanded
grouts.Generallywhitegroutisbestsuitedforgroutingwhiteorlightcoloredmarbleorgranite.Followtile
manufacturer’s
recommendations.Testasmallareapriortouse.Certaintilewithhighabsorption,surfaceporosityorroughtexturedsurfacesand
certaintypesofporcelainmayrequiresealingpriortogroutingtopreventstaining.
SURFACEPREPARATION:
a. Tilemustbefirmlyattachedtoasoundsubstrateandsettingmaterialmustbe
curedforaminimumof2448hoursbeforegrouting.
b. Removeallspacers.Groutjointsshouldbeuniformindepthandwidthandfreeofallloosedebris,contaminantsandexcessmortaror
adhesive.
APPLICATION:
Newinstallation:
a. Beforegrouting,soakthegroutspongeinapailofcleancoolwaterandthoroughly wringout.
b. Usethedampenedspongeandlightlywipethetilesurfaceinanareanolargerthan510sq.ft.Aslightlywettilesurfaceallowsthe
grouttoglideeasilyoverthetileandintothegroutjointwhileprovidingforeasier
cleanup.
c. Whiletileisstilldamp,dispensealiberalamountofgroutontothetilesurface.
d. Usingthegroutfloat,pressthegroutintothegroutjointsoverthedampenedareaapplygroutonnomorethan510sq.ft.atatimeto
allowforpromptcleaning;
delayedcleaningmaycausesomecracking.
e. Placethe groutfloatonedgeata45°angleandrakethefloatdiagonallyacrossthetilesurfacewhileexertingadownwardpressure.This
willforcethegroutevenlyintothegroutjoints.
f. Immediatelyremoveallexcessgroutfromthe
tilesurfacebyholdingthegroutflatata90°angletothetileanddrawingitdiagonally
acrossthetile.
g. Cleanbysoakinggroutspongeincleancoolwater .Wringoutexcesswatercompletely.
h. Usedampenedspongeinacircularmotiontosmoothgroutjointsandclean
offanyremainingexcessgrout.
i. Continue rinsingofspongeinclean,coolwaterwillaidincleanup.
j. Avoidexcesswateringroutjoints.Forfinalcleaning/hazeremoval,allowgrouttocurefor24hours.Useadampenedsponge,thensoft
clothtopolishoffresidue.
Repairexistinggrout:
a. Removeexistingoldgroutwithagroutsaw1/8”belowthesurfaceofexistingtile,Sweeporvacuumdustanddebrisfromsurfaceoftile
andgroutjoints.
b. ShawArrayGroutcanbeapplieddirectlyoveroldgrout.Applyenoughtototallycovertheoldgrout.Followdirectionsfor
new
installationasshownabove.
CLEANUP:
Cleantoolsandhandswithcoldwaterbeforematerialdries.
CARE&MAINTENANCE:
MoldandMildewcangrowondirt,food,andsoapscumthatcanaccumulateonthegroutsurface.Routinecleaningwilllimitmoldandmildew
growth.
SAFETY:
Avoideyecontactor
prolongedcontactwithskin.Washthoroughlyafterhandling.Ifeyecontactoccurs,flushwithwaterfor15minutesand
consultaphysician.
INSTALLATIONFORVINYLPLANKS:
LayoutoftheRoom:
a. Findthecenterpointoftheroom.Strikealine.
b. Obtainatrue90’anglebyusing
acarpenter’ssquare.
c. Strikeasecondlinewhichwilldividetheroomintofourequalparts.
d. Measurethedistancefromthecentertothewall,paralleltothedirectionoftheplank.
e. Dividethemeasurementbythewidthoftheplank.Iflessthanhalfremainsas
theborderplank,adjustthe
pointtocompensate.Thiswillgivealargerborderalongthewallandreducethechanceofhavingtocutasmall
sliverofflooringtoplacealongthewall.
LayoutofthePlank:
a. Carefullyplacethefirstpieceofplankatthejunctionofthechalklines.
b. Continuetolaytheplank,makingsureeachplankflushagainstthechalklineandtightagainsttheadjoiningplank.
c. Makesuretheplankiswellseatedintotheadhesivepayingspecialattention,to the edges.Layrow by row, or in a pyramidfashionas
shownbelow.
FittingtheBorder:
a. Measurethedistancefromthelastplankintherowtothewall.
b. Marktheplankandcutitagainstthemark.
c. Laythe
plankinplace,makingsurethatthecutedgeisagainstthewall.
FittingAroundIrregularObjects:
a. Makeapatternoutofheavypapertofitaroundpipesandotherirregularities.
b. Placethepatternontheplank,tracecuttingalongthetracelines.
IMPORTANT:Allflooringmustbyrolledwithaminimum100lbrollerafterinstallation.Useahandrollerinareasnotreachedwitha100lb.
roller.
8.LIMITEDWARRANTY
Forcompletewarrantyinformation,pleasecallShawInformationCenter:1800.441.7429
Shaw Industries Group, Inc., a Berkshire Hathaway Company. Revised10/08/14
/