Panasonic CUC125KH Operating instructions

Type
Operating instructions

This manual is also suitable for

1
CONTENTS
: FEATURES....................................................................... 3
:
: SAFETY PRECAUTIONS........................................... 4 – 6
Installation Precautions
Operation Precautions
:
: NAME OF EACH PART ........................................... 7 – 10
Indoor Unit
When the front panel is opened
Outdoor Unit
Accessories
Remote Control
When the remote control is opened
How to use the remote control
When the back cover is opened
:
: PREPARATION BEFORE OPERATION ............... 11 – 12
Indoor Unit
Remote Control
Inserting batteries
Setting the clock
About the batteries
:
: HOW TO OPERATE............................................... 13 – 14
Automatic • Cooling • Soft Dry • Fan
Operation details
Adjusting Airflow Direction and Fan Speed
Operation details
:
: SETTING THE TIMER ............................................ 15 – 16
Recommended Setting of Timer
:
Before use
How to use
2
ENGLISH
: CONVENIENCE OPERATION ............................... 17 – 18
Sleep Mode
Operation details
Economy or Powerful Mode
Operation details
:
: CARE AND MAINTENANCE ................................. 19 – 22
Cleaning the Indoor Unit and Remote Control
Cleaning the Air Filter
Cleaning the Front Panel
Removing the front panel
Fixing the front panel
Cleaning the front panel
Replacing the Air Purifying Filters
Removing the air purifying filters
Reinstalling the air purifying filters
Pre-season Inspection
When the Air Conditioner is Not Used for an Extended
Period of Time
Recommended Inspection
:
: TROUBLESHOOTING ........................................... 23 – 24
Normal Operation
Abnormal Operation
Call the Dealer Immediately
:
: HELPFUL INFORMATIONS........................................... 25
:
: ENERGY SAVING AND OPERATION HINTS............... 26
:
If necessary
3
FEATURES
Note:
Before using your air-conditioner, please read
this operating instructions carefully and keep
it for future reference.
Thank you for purchasing a National Room Air
Conditioner.
AUTO RESTART CONTROL
Automatically restart the unit after power
failure.
(Refer page 25)
SELF-ILLUMINATING BUTTON
For your convenience to operate in the dark.
(Refer page 9)
AUTOMATIC OPERATION
Select the optimum mode.
(Refer page 13)
SLEEP MODE
Prevent the room from getting too hot or too cold
while you are sleeping.
(Refer page 17)
ECONOMY MODE
To reduce electrical power consumption.
(Refer page 18)
POWERFUL MODE
Reaches the desired room temperature quickly.
(Refer page 18)
REMOVABLE FRONT PANEL
For quick and easy cleaning (washable).
(Refer page 20)
CATECHIN AIR PURIFYING FILTER
Filter that can trap dust, tabacco smoke and tiny
particles in the room. It can also prevent the
growth of bacteria and viruses trapped in this
filter.
(Refer page 21)
4
ENGLISH
Do not install, remove and reinstall the unit yourself.
Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for
the installation work.
SAFETY PRECAUTIONS
Before operating, please read the following “Safety Precautions” carefully.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified
as follows :
The instructions to be followed are classified by the following symbols :
! Warning /
! Caution /
This symbol (with a white background) denotes
an action that is PROHIBITED.
OFF
These symbols (with a black background)
denote actions that are COMPULSORY.
! Warning /
This sign warns of death or serious injury.
! Caution /
This sign warns of damage to property.
This room air conditioner must be earthed.
Improper grounding could cause electric
shock.
Do not install the unit in a place where there may
be explosive gas leaks.
Gas leaks near the unit could cause fires.
Ensure that the drainage piping is connected
properly.
Otherwise, water will leak out.
Installation Precautions /
5
Do not share outlet.
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
! Warning /
This sign warns of death or
serious injury.
Plug in properly.
Do not operate with wet
hands.
Operation Precautions /
Use specified power cord.
Do not damage or modify
the power cord.
If abnormal condition (burnt smell, etc) occurs, switch off
and unplug the power supply.
OFF
Do not repair by yourself.
Do not expose directly to cool air
for a long period.
Do not insert finger or other objects into the indoor or
outdoor units.
Do not insert plug to operate
the unit. Do not pull out plug
to stop the unit.
6
ENGLISH
Do not wash the unit with water.
Do not use for other purpose such as preservation or etc.
Do not use any combustible equipment at
airflow direction.
Do not sit or place anything on the outdoor unit.
Ventilate the room regularly.
Pay attention as to whether the installation rack is
damaged due to long period of usage.
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
! Caution /
This sign warns of injury.
Do not pull the cord to disconnect the plug.
Switch off the power supply if the unit is not
used for a long period.
OFF
Switch off the power supply before
cleaning it.
7
NAME OF EACH PART
Indoor Unit
Air Intake Vent
Power Supply Cord
Panel Opener
Signal Receptor
Operation Indicators
POWER : Green
SLEEP : Orange
TIMER : Orange
Air Outlet Vent
Horizontal Airflow Direction
Louver (Manually adjusted)
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
Front Panel
When the front panel is opened
Front Panel
Air Filters
Auto Operation Button
Tab for Front Panel
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
Air Purifying Filter
Economy/Powerful Indicators
Economy - Green
Powerful - Orange
Vertical Airflow Direction Louver
8
ENGLISH
Outdoor Unit Accessories
CU-C125KH
Air Intake Vents
(Side)
Piping
Ground Terminal (Inside Cover)
Air Outlet Vents
Air Intake Vents
Ground Terminal
(Inside Cover)
Air Outlet Vents
CU-C75KH
CU-C95KH
(Rear)
Two RO3 dry-cell batteries or
equivalent
Remote Control
Remote Control Holder
Connecting
cable
Drain Hose
Drain Hose
Connecting
cable
Piping
POWERFUL
TEMP
OFF/ON
COOL
AUTO
(Side)
(Rear)
Air Purifying Filters
(Catechin Air Purifying Filter)
9
AIR SWING
TIMER
CLOCK
1
2
3
FAN
COOL
LO
HI
DRY
AUTO
AUTO
ON
AUTO FAN
AIR
SWING
AM PM
OFF
AM PM
MODE
ECONOMY
FAN SPEED
AUTO
MANUAL
ON OFF
SET
CANCEL
SLEEP
Powerful Mode
Operation Button
Operation Display
Signal Transmitter
When the remote control cover is opened
Timer Set Button
ON-TIMER Button
OFF-TIMER Button
Timer Cancellation Button
Sleep Mode
Operation Button
Manual Airflow Direction
Selection Button
Time-Setting Button
Operation Display
Economy Mode
Operation Button
Clock Button
Auto Airflow
Direction Button
Operation Mode Selection Button
Remote Control
Fan Speed
Selection Button
POWERFUL
TEMP
OFF/ON
COOL
AUTO
OFF/ON Button
(Self-illuminating Button)
Room Temperature
Setting Button
(Self-illuminating Button)
10
ENGLISH
When the back cover is opened
How to use the remote control
Maximum distance : 10 m
Make sure it is not obstructed.
OPEN
Notes /
Do not throw or drop
Do not get it wet
Certain type of fluorescent lamps may affect
signal reception. Consult your dealer.
Signal receptor
Signal received sound.
One short beep or one long beep.
Reset points
short to clear the
memory
Aim at the signal receptor.
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Panasonic CUC125KH Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI