Mr. Heater HEATSTAR MH35CLP Operating instructions

Category
Space heaters
Type
Operating instructions

This manual is also suitable for

04/12 Rev12A 28835MR. HEATER, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
WARNING:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
An LP cylinder not connected for use shall not be stored in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light appliance.
Extinguish any open flame.
Shut off gas to appliance.
Service must be performed by a qualified service agency.
This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used.
Adequate combustion and ventilation air must be provided. Refer to page E-3.
FORCED AIR PROPANE
CONSTRUCTION HEATER
LANGUAGES
ENGLISH
Pages E1 — E10
SPANISH
Pages S1 — S10
FRENCH
Pages F1 — F10
If the information in this manual is not followed exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
For model serial numbers,
see page E10.
MH60CLP
OPERATING INSTRUCTIONS

 Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
Model #
E-2
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual
SPECIFICATIONS
Type of Gas:................................. For use with Propane Only
Gas Supply Pressure
to regulator ............................... Max: 200 psi (1380 kPa)
Min: 5 psi (34.4 kPa)
regulator out ............................. 59" WC (14.70 kPa)
Manifold Pressure: .......................53" WC (13.20 kPa)
Electrical Input: ............................ 110/220V, 50/60 Hz, 1Ø, 2A
Ignition: .......................................Auto Spark/Manual Gas Valve
Primary Flame Control: .................Thermocouple Operated Gas Valve
High Temperature Control: ...........240°F (115°C)
Min. Ambient Temp. Rating 0°F (-17.8°C)
Model: ........................................ MH60Cl P
Rating: .........................................30,000 - 60,000 BTU/hr
(8.79 - 17.58 kW)
Fuel Consumption: .......................2.78 #/hr (1.26 kg/hr)
Fuel Orifice Port Size: ................... 1.55mm
Fan Rating: ..................................135 cfm
CONTENTS
HEATER SPECIFICATIONS ............................................................. E-2
WARNINGS ................................................................................. E-2
OPERATING PRECAUTIONS ......................................................... E-3
SAFETY PRECAUTIONS ................................................................ E-3
ODOR FADE WARNING ............................................................... E-4
PREPARING FOR OPERATION ....................................................... E-5
BATTERY CHARGING PROCEDURE ............................................... E-5
BATTERY INFORMATION ............................................................ E-5
BATTERY RECYCLING INFORMATION .......................................... E-5
HEATER OPERATION ................................................................... E-6
MAINTENANCE AND STORAGE ................................................... E-6
SERVICING ................................................................................. E-6
WIRING SCHEMATIC .................................................................. E-7
PARTS LIST .................................................................................. E-8
SIZE AND CAPACITY OF PROPANE INFORMATION ....................... E-9
WARRANTY INFORMATION .......................................................E-10
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE
AWAY FROM THE HEATER AS RECOMMENDED BY THE
INSTRUCTIONS. NEVER USE THE HEATER IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN-
KNOWN CHEMICALS.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
General Ha Zard warn InG:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX-
IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
THe sTaTe OF Cal IFOrn Ia re QuIres THe FOll OwInG warn InGs:
WARNING: Combustion by-products produced when using this product contain carbon monoxide, a chemical
known to the State of California to cause cancer and birth defects (or other reproductive harm).
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or
other reproductive harm.
E-3
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual
OPERATING PRECAUTIONS
This is a propane, direct-fired, forced air heater. It's intended use
is primarily temporary heating of buildings under construction,
alteration or repair.
Propane is heavier than air. If propane leaks from a connection or
fitting, it sinks to the floor, collecting there with the surrounding
air, forming a potentially explosive mixture. Obviously, propane
leaks should be avoided, so set up the propane supply with utmost
care. Read enclosed Odor Fade and Propane Sheet for additional
information about detecting propane leaks. Leak check new
connections or reconnections with a soap and water solution and
follow all connection instructions herein. Also, ask your propane
dealer for advice on the propane application and supply installation
and ask him to check it if there are any questions.
This heater was designed and certified for use as a construction
heater in accordance with ANSI Standard Z83.7/CGA 2.14. Check
with your local fire safety authority if you have any questions about
your applications. Other standards govern the use of fuel gases and
heat producing products in specific applications. Your local authority
can advise you about these.
Direct-Fired means that all of the combustion products enter the
heated space. Even though this heater operates very close to 100
percent combustion efficiency, it still produces small amounts of
carbon monoxide. Carbon monoxide (called CO) is toxic. We can
tolerate small amounts but not a lot. CO can build up in a heated
space and failure to provide adequate ventilation could result in
death. The symptoms of inadequate ventilation are:
headache
dizziness
burning eyes and nose
nausea
dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating
instructions.
Forced Air means that a blower or fan pushes the air through the
heater. Proper combustion depends upon this air flow; therefore,
the heater must not be revised, modified or operated with
parts removed or missing. Likewise, safety systems must not be
circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people
the user is responsible for properly acquainting those present with
the safety precautions and instructions, and of the hazards involved.

1. Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
2. DO NOT modify the heater or operate a heater which has been
modified from its original condition.
3. Use only propane gas.
4. Use only VAPOR WITHDRAWAL propane supply. If there is any
question about vapor withdrawal, ask your propane dealer.
5. Mount the propane cylinders vertically (shutoff valve up).
Secure them from falling or being knocked over and protect
them from damage.
6. Locate propane containers at least (USA) 7 ft. (2.13m), (Canada)
10 ft. (3m) from the heater and do not direct exhaust toward
containers.
7.  Use only the hose and regulator assembly
provided with the heater. Match the color stripe on the hang
tag attached to the hose assembly with the color on the label
located near the propane inlet fitting on the heater. Inspect
hose assembly before each use of the heater. If there is
excessive abrasion or wear, or hose is cut, replace with hose
assembly listed on parts list before using heater.
8. For indoor use only. Area must be well ventilated. Provide
minimum openings of 1/2 sq. ft. (.046 m²) near the floor
and 1/2 sq. ft. (.046 m²) near the ceiling (also see "Operating
Precautions").
9. If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor fade and Propane
Sheet for additional information about detecting propane leaks.
10. Install the heater such that it is not directly exposed to water
spray, rain and/or dripping water.
11. Maintain minimum clearance from normal combustible material
(like paper) as follows: floor-0 ft. (0 m); outlet-6 ft. (1.83m);
sides-2 ft. (.61m); top-6 ft. (1.83m). Locate 10 ft. (3m) from
canvas or plastic tarpaulins or similar coverings and secure them
to prevent flapping or movement due to wind action.
12. Due to the high surface and exhaust temperatures, adults and
children must observe clearances to avoid burns or clothing
ignition.
13. Operate only on a stable, level surface.
14. Do not use with duct work. Do not restrict inlet or outlet.
15. Use only the electrical power specified. The electrical
connection and grounding must comply with National Electrical
Code - ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical
Code, Part 1 (Canada).
16. Use only a properly grounded 3-prong receptacle or extension
cord (6 ft (1.83m) in length minimum).
17. Do not move, handle or service while hot or burning.
18. Use only in accordance with local codes or, in the absence of
local codes, with the Standard for the Storage and Handling
of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1,
Natural Gas and Propane Installation Code.
E-4
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
• Do not use this heater for heating human living
quarters.
• Do not use in unventilated areas.
• The flow of combustion and ventilation air must not
be obstructed.
• Proper ventilation air must be provided to support
the combustion air requirements of the heater
being used.
• Refer to the specification section of the heater’s
manual, heater dataplate, or contact the factory to
determine combustion air ventilation requirements
of the heater.
• Lack of proper ventilation air will lead to improper
combustion.
• Improper combustion can lead to carbon monoxide
poisoning leading to serious injury or death.
Symptoms of carbon monoxide poisoning can
include headaches dizziness and difficulty in
breathing.


specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel



Do not take any action that could ignite the fuel gas. Do
not operate any electrical switches. Do not pull any power
supply or extension cords. Do not light matches or any
other source of flame. Do not use your telephone.
Get everyone out of the building and away from the area
immediately.
Close all propane (LP) gas tank or cylinder fuel supply
valves, or the main fuel supply valve located at the meter if
you use natural gas.
Propane (LP) gas is heavier than air and may settle in low
areas. When you have reason to suspect a propane leak,
keep out of all low areas.
Use your neighbor’s phone and call your fuel gas supplier
and your fire department. Do not re-enter the building or
area.
Stay out of the building and away from the area until
declared safe by the firefighters and your fuel gas supplier.
FINALLY, let the fuel gas service person and the firefighters
check for escaped gas. Have them air out the building and
area before you return. Properly trained service people
must repair any leaks, check for further leakages, and then
relight the appliance for you.
ODOR FADING - NO ODOR DETECTED
Some people cannot smell well. Some people cannot smell
the odor of the man-made chemical added to propane (LP)
or natural gas. You must determine if you can smell the
odorant in these fuel gases.
Learn to recognize the odor of propane (LP) gas and
natural gas. Local propane (LP) gas dealers will be more
than happy to give you a scratch and sniff pamphlet. Use it
to become familiar with the fuel gas odor.
Smoking can decrease your ability to smell. Being around
an odor for a period of time can affect your sensitivity to
that particular odor. Odors present in animal confinement
buildings can mask fuel gas odor.

colorless and the intensity of its odor can fade under
some circumstances.
If there is an underground leak, the movement of gas
through the soil can filter the odorant.
Propane (LP) gas odor may differ in intensity at different
levels. Since Propane (LP) gas is heavier than air, there may
be more odor at lower levels.
If you
continue to detect any gas odor, no matter how small, treat
it as a serious leak. Immediately go into action as discussed
previously.


Propane (LP) gas has a distinctive odor. Learn to recognize
these odors. (Reference Fuel Gas Odor and Odor Fading
sections above.
Even If you are not properly trained in the service and
repair of the heater, ALWAYS be consciously aware of the
odors of propane (LP) gas and natural gas.
If you have not been properly trained in repair and service
of propane (LP) gas then do not attempt to light heater,
perform service or repairs, or make any adjustments to the
heater on the propane (LP) gas fuel system.
A periodic sniff test around the heater or at the heater’s
joints; i.e. hose, connections, etc., is a good safety practice
under any conditions. If you smell even a small amount of
gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY.
DO NOT WAIT!
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is found,
immediately notify the factory.
2. Charge battery (Refer to Battery Charging Procedure Section).
3. Follow all of the "Precautions".
4. Connect the POL fitting of hose and regulator assembly to the
propane cylinder by rotating the POL nut counterclockwise into
the propane cylinder's valve outlet and securely tighten with a
wrench.
5. Connect the hose to the heater by rotating the hose fitting
clockwise.
E-5
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual
6. Securely tighten all gas connections.
7. Slowly open the cylinder's gas valve and check all gas
connections with a soap and water solution, looking for bubbles
that would indicate a gas leak. Note: if tank valve is not opened
slowly, the excess flow check valve on the propane tank may stop
gas flow. DO NOT USE A FLAME.
8. Close propane cylinder gas valve.









1. Turn off heater.
2. Plug power/charging cord into the power receptacle on the
heater rear guard and directly into a 120V electric outlet. DO
.
*Never carry the heater by the cord. Do not disconnect the
heater from the outlet by pulling the cord.
*Always charge the heater in a dry area protected from the
weather, Do not expose the heater or charger to rain. Do not
charge in wet locations.
*Do not charge the battery when temperature is above 104° F
(40°C) or below 0°F (-17.8°C).
*Charge the heater battery in a well ventilated location.
*Keep the heater and charger away from water, heat sources
(such as radiators, other heaters, stoves, etc.), flames and /
or chemicals. Be careful not to damage the charger cord by
keeping cord away from sharp edges.
WARNING
To reduce the risk of fire, electric shock or personal injury
do not attempt to use this charger with any other product.
Likewise, do not attempt to charge the HERO battery with any
other charger.
3. The green LED light on the on/off switch will begin a slow
continuous flash indicating that the battery is charging.
4. The green LED light will stop blinking and turn off when the
battery is fully charged.
5. It takes approximately 5 hours to charge a completely discharged
battery.
6. The heater is designed to operate and charge the battery at the
same time when plugged into a 120V outlet.
7. Mr Heater recommends continuously charging the battery,
between heater uses, for optimal performance. If constant
maintenance charging is not possible, it is recommended that the
battery be fully charged every 3 months. See Maintenance and
Storage section on page E-6.
8. Low Battery: The heater is equipped with an active battery
monitoring system. When the heater is operating on the
internal battery only, the green LED light on the control panel will
begin to flash when there is approximately 1 hour of operating
time remaining.
9. Low Voltage Shutdown: To prevent battery deep discharge and
prolong battery life, the heater monitors the battery and safely
shuts down when a specified voltage has been reached. The
heater will not restart until it has been plugged into a 120V
power source.




The battery is a 12-volt sealed lead acid system. There is no
liquid contained within the battery and the heater/battery can
therefore be stored in any position without fear of leakage.
* For optimal performance, the battery should be completely
charged before the heater's initial operation and kept on
constant charge when not in use.
* The battery should be charged in its proper orientation.
* The battery does not need to be fully discharged before
recharging.
* 2 to 3 initial charging cycles may be required after purchase
to achieve maximum run time capacity.
* A fully charged battery can be safely stored down to -17°C
(-0°F).
* The Battery is maintenance free.
* The battery is intended for use in the Mr Heater HERO
heater only and should not be used for any other purpose.

The RBRC™ (Rechargeable Battery Recycling Corporation) seal
on the lead acid battery (or battery pack) indicates that the
costs to recycle the battery (or battery pack) at the end of its
useful life have been paid by ENERCO GROUP INC. In some
areas, it is illegal to place spent lead acid batteries in the trash or
municipal solid waste stream and the RBRC program provides an
environmentally conscious alternative.
RBRC™ in cooperation with ENERCO GROUP INC and other
battery users, has established programs in the United States and
Canada to facilitate the collection of spent lead acid batteries.
Help protect our environment and conserve natural resources
by returning the lead acid battery to your local retailer
for recycling. You may also contact your local
recycling center for information on where to drop
off the spent battery or call (800)251-0001 x3611.

Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual

1. The heater should be inspected before each use, and at least
annually by a qualified person.
2. Before each use, check the soft "O" ring seat at the bullnose
of the POL fitting. If the "O" ring is cut, scuffed, or otherwise
damaged, replace it with part number F273786.
3. Turn off the gas at the LP-gas supply cylinder(s) when the heater
is not in use.
4. When the heater is to be stored indoors, the connection
between the LP-gas supply cylinder(s) and the heater must
be disconnected and the cylinder(s) removed from the heater
and stored out of doors and in accordance with Chapter 5 of
the standard for Storage and Handling of Liquefied Petroleum
Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane
Installation Code.
5. It is recommended that the internal battery be maintained on a
constant maintenance charge by leaving it plugged into a 120V
power source. If constant maintenance charging is not possible,
it is recommended that the battery be fully charged every 3
months.
6. The heater may be stored with the charger disconnected if all of
the following conditions are met.
•The battery is fully charged before storing. (Failure to store fully
charged will shorten battery life.)
•The average temperature of the storage location is below 50°
(10°C).
•Storage duration is less than 6 months.

A hazardous condition may result if a heater is used that has been
modified or is not functioning properly. When the heater is working
properly:
* The flame is contained within the heater.
* The flame is essentially blue with perhaps some yellow tipping.
* There is no strong disagreeable odor, eye burning or other
physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the
heater.
The parts lists and exploded view show the heater as it was
constructed. Do not use a heater which is different from that shown.
In this regard, use only the hose, regulator and cylinder connection
fitting (called a POL fitting) supplied with the heater. 
Match the color stripe on the hangtag attached to the hose assembly
with the color on the label located near the propane inlet fitting on
the heater. Do not use alternates. For this heater, the regulator must
be set as shown in "specifications". If there is any uncertainty about
the regulator setting, have it checked.
A heater which is not working right must be repaired, but only by a
trained, experienced service person.
In-warranty products will be repaired with no charge for either parts
or labor. Please include a brief statement indicating date, place of
purchase, the nature of the problem and proof of purchase.
Out-of-warrranty products will be repaired with a charge for parts,
labor and shipping.
WARNING
FIRE HAZARD—ALWAYS DISCONNECT THE HEATER FROM
THE POWER SUPPLY (WALL OUTLET) BEFORE REMOVING
THE POWER CORD FROM THE HEATER. UNDER CERTAIN
CONDITIONS, WITH THE HEATER PLUGGED INTO THE POWER
SUPPLY, THE EXPOSED CONNECTOR CAN BE SHORTED BY
FOREIGN MATERIAL AND MAY CAUSE A FIRE. FOREIGN
MATERIALS OF A CONDUCTIVE NATURE, SUCH AS, BUT NOT
LIMITED TO, STEEL WOOL, ALUMINUM FOIL, OR ANY BUILD-
UP OF METALLIC PARTICLES, SHOULD BE KEPT FROM THE
CONNECTOR. ALWAYS UNPLUG HEATER BEFORE ATTEMPTING
TO CLEAN.
HEATER OPERATION
START
1. The HERO heater is equipped with a blower fan switch, located
on the control panel of the heater. Press the on/off switch to
start the blower fan. Once the fan has been turned on, the
green LED light on the control panel will turn on solid, indicating
that the fan is operating. The blower fan must be turned on
before the gas/igniter valve is SLOWLY pressed to light the
heater.

cannot be depressed until after the fan has been started.
2. Open propane supply valve on propane tank slowly. Note: If not
opened slowly, excess-flow check valve on propane tank will stop
gas flow. If this happens, close propane supply valve and open
again slowly. Wait 15 seconds before Step 3.
3. After the blower fan has been started, SLOWLY depress the
orange gas/igniter valve button located on the control panel to
ignite the heater. If the heater fails to light, release the orange
button and repeat this step. Keep the valve depressed for 30-60
seconds, after burner lights, then release and the heater will
continue to operate. If the burner shuts off, wait 20 seconds and
repeat these steps.
NOTICE: This heater is equipped with a safety solenoid lockout
that prevents the gas valve being depressed until the heater
is turned on and the fan is operating. This system allows 30
seconds for ignition attempts. After 30 seconds the heater must
be reset for additional attempts. To reset, switch the on/off
switch to off and then back on.

When the heater detects a power source change (connect or
disconnect AC power while operating) it will automatically shut down.
After shut down, the "START" procedure will have to be used to
restart the heater.

This heater is equipped with a low battery voltage lockout
safety system that prevents operation if the battery voltage is too low.
STOP
1. Press the on/off switch to turn off the heater.
2. Turn off gas supply when heater is not in use.
E-7
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual
When service or repair is required, it is recommended that you
take your heater to an authorized Mr Heater Service Center.
When servicing or replacing batteries, please note:
Do not service the heater with battery connected or plugged into
a power outlet.
Do not operate a damaged heater. Replace damaged cords
immediately.
Use only Mr Heater original battery type.
Do not dispose of the batteries in a fire. The cell may explode.
See ”Battery Recycling Information” below.
Do not open or mutilate the batteries. Released electrolyte is
corrosive and may cause damage to the eyes or skin. It may be
toxic if swallowed.
Exercise care in handling batteries in order not to short the
battery with conducting materials such as rings, bracelets and/
or keys. The battery and/or conductor may overheat and cause
burns.
8
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual
re F.# ITeM# des Cr IPTIOn QTY.
19 28823 tubing,assy,gas,burner,inlet,60k 1
20 27930 board,led,off,switch,35k 1
21 28822 orifice,60k 1
22 27939 holder,orifice 1
23 28801 base,upper,plastic,60k 1
24 28806 board,power,supply,clp 1
25 28808 brkt,plastic,board,mount,60k 2
26 28804 cover,battery,60k 1
27 22815 board,control,main,clp 1
28 28830 base,lower,plastic,60k 1
29 28840 cover,wires,obe,60k 1
30 28842 board,battery,connector,obe,60k 1
31 27927 battery,35k 1
32 28803 door,battery,60k 1
33 28839 hose,regulator,assy,60k 1
* 27953 power supply cord 1
* 27954 battery connection wiring harness 1
* Not shown on exploded parts view.
re F.# ITeM# des Cr IPTIOn QTY.
1 28802 guard,rear,plastic,60k 1
2 28817 fan,brushless,dc,60k 1
3 28818 plate,air,restraint,steel,60k 1
4 28815 thermocouple,assy,60k 1
5 28819 burner,assy,main,60k 1
6 27925 handle,carry,35k 1
7 27935 switch,high,limit 1
8 28836 electrode,ignition,60k 1
9 28838 holder,flame,assy,60k 1
10 28812 shield,radiation,assy,60k 1
11 28811 barrel,assy,obe,60k 1
12 27931 receptacle,power,supply 1
13 28805 bracket,valve,60k 1
14 28831 valve,gas,assy,clp,60k 1
15 28843 solenoid,valve,lockout 1
16 27926 knob,valve 1
17 28827 knob,variable,valve 1
18 28809 board,ignition,12v 1
Forced a ir Propane Construction Heater • Model #MH60Cl P
33
E-9
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual


The charts below show the approximate size of the cylinder required
for these heaters. To use the chart:
1. Select the lowest air temperature expected (at the bottom of
the chart).
2. Move straight up to time of operation desired (left side of
chart).
3. Read the cylinder size required.
All heaters should have: full cylinders
good air circulation
no frost on cylinders


We are pleased that you have selected our product and take
this opportunity to assure you that qualified service facilities are
available if required. With the cooperation of independent dealers,
a nationwide network of authorized servicing dealers is available for
your servicing requirements.
Should your product require servicing, read the section of the
manual entitled “Servicing”.
Who gets the warranty? The warranty is limited to the consumer
who originally purchases the product.
What is covered? This limited warranty covers all imperfections in
workmanship and material.
What is not covered? This limited warranty does not cover
damage resulting from accident, misuse or abuse, lack of proper
maintenance, affixing of any attachments not provided with the
products, or loss of parts. IN NO EVENT SHALL ENERGO TECHNICAL
PRODUCTS BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES NOR FOR ANY DAMAGES RESULTING
FROM MISUSE OR MODIFICATION OF THIS PRODUCT.

E-10
Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT
FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.

PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or direct
from the factory

Please call Toll-Free 800-251-0001 • www.mrheater.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all
communication.

The company warrants this product to be free from imperfections in material or workmanship,
under normal and proper use in accordance with instructions of The Company, for a period of
one year from the date of delivery to the buyer. The Company, at its option, will repair or replace
products returned by the buyer to the factory, transportation prepaid within said one year period
and found by the Company to have imperfections in material or workmanship.
If a part is damaged or missing, call our Technical Support Department at 800-251-0001.
Address any Warranty Claims to the Service Department, Mr. Heater Group, Inc., 4560 W. 160th
St., Cleveland, Ohio 44135. Include your name, address and telephone number and include
details concerning the claim. Also, supply us with the purchase date and the name and address
of the dealer from whom you purchased our product.
The foregoing is the full extent of the responsibility of the Company. There are no other
warranties, express or implied. Specifically there is no warranty of fitness for a particular purpose
and there is no warranty of merchantability. In no event shall the Company be liable for delay
caused by imperfections, for consequential damages, or for any charges of the expense of
any nature incurred without its written consent. The cost of repair or replacement shall be the
exclusive remedy for any breach of warranty. There is no warranty against infringement of the
like and no implied warranty arising from course of dealing or usage of trade. This warranty
will not apply to any product which has been repaired or altered outside of the factory in any
respect which in our judgment affects its condition or operation.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This Warranty gives you specific legal
rights, and you may have other rights which vary from state to state.
Mr. Heater Group, Inc.
reserves the right to make changes at any time, without notice or
obligation, in colors, specifications, accessories, materials and models.
Mr. Heater, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
ANSI Z83.7b-2009/CSA 2.14b-2009
 
Number
MH60CLP F228810-12001001
MH60CLP
OPERATING INSTRUCTIONS

 Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
Model #
PRODUCT REGISTRATION: Thank you for your purchase.
Please log in to http://www.egiregistration.com to register your product.
S-2
Calentador de propano a aire forzado para construcción Instrucciones de uso y manual del usuario
ESPECIFICACIONES
Tipo de gas: ........................... Para usar únicamente con gas
propano
Presión del suministro de gas
de entrada al regulador ........ Máx.: 1380 kPa (200 psi)
Mín.: 34,4 kPa (5 psi)
de salida al regulador ........... 149,8 cm.c.a (59" WC) (14,70 kPa)
Presión del colector: ............... 134,6 cm. (53" WC) (13,20 kPa)
Entrada de corriente: ............. 10/220 V, 50/60 Hz, 1Ø, 2A
Encendido:............................. Chispa automática/
válvula de gas manual
Control primario de la llama: .. Válvula de gas operada por
termocupla
Control de alta temperatura: .. 115
o
C (240
o
F)
Temperatura ambiente mínima
Especificaciones -17,8
o
C (0
o
F)
Modelo: ................................ MH60CLP
Especificación: ....................... 30.000 - 60.000 BTU/hr
(8,79 - 17,58 kW)
Consumo de combustible: ..... 2,78 #/hr (1,26 kg/hr)
Tamaño del puerto del
orificio de combustible: ......... 1,55 mm
Especificaciones
para el ventilador: .................. 135 pcm
CONTENIDOS
ESPECIFICACIONES DEL CALENTADOR ........................................ S-2
ADVERTENCIAS ........................................................................... S-2
PRECAUCIONES DE UTILIZACIÓN ................................................ S-3
PRECAUCIONES DE SEGURIDAD.................................................. S-3
ADVERTENCIA DE DISIPACIÓN DEL OLOR .................................... S-4
PREPARATIVOS PARA OPERACIÓN ............................................... S-5
PROCEDIMIENTO DE RECARGA DE BATERÍA ................................ S-5
INFORMACIÓN DE LA BATERÍA .................................................. S-5
INFORMACIÓN DE RECICLAJE DE BATERÍAS ............................... S-5
FUNCIONAMIENTO DEL CALENTADOR ....................................... S-6
MANTENIMIENTO Y ALMACENAMIENTO .................................... S-6
REPARACIÓN .............................................................................. S-6
ESQUEMA DE CABLEADO .......................................................... S-7
LIST
A DE PA
RTES ......................................................................... S-8
INFORMACIÓN SOBRE TAMAÑO Y CAPACIDAD DEL PROPANO ........S-9
INFORMACIÓN DE GARANTÍA ...................................................S-10
ADVERTENCIA:
PELIGRO DE INCENDIO, QUEMADURAS, INHALACIÓN Y
EXPLOSIÓN. MANTENGA LOS COMBUSTIBLES SÓLIDOS
COMO MATERIALES DE CONSTRUCCIÓN, PAPEL O
CARTÓN A UNA DISTANCIA SEGURA DEL CALENTADOR
TAL COMO LO RECOMIENDAN LAS INSTRUCCIONES.
NUNCA USE EL CALENTADOR EN ESPACIOS QUE
CONTIENEN O PODRÍAN CONTENER COMBUSTIBLES
VOLÁTILES O PRODUCTOS COMO GASOLINA,
SOLVENTES, DILUYENTE DE PINTURA O PRODUCTOS
QUÍMICOS DESCONOCIDOS.
ADVERTENCIA:
NO APTO PARA USAR EN EL HOGAR NI EN CASAS
RODANTES.
ADVERTENCIA:
SU SEGURIDAD ES IMPORTANTE PARA USTED Y PARA LOS
DEMÁS. POR ELLO, LEA ESTAS INSTRUCCIONES ANTES DE
UTILIZAR EL CALENTADOR.
ADVERTENCIA GENERAL DE PELIGRO:
EL NO CUMPLIR CON LAS PRECAUCIONES E
INSTRUCCIONES QUE VIENEN CON ESTE CALENTADOR
PUEDE CAUSAR LA MUERTE, LESIONES GRAVES Y
PÉRDIDAS Y DAÑOS MATERIALES DERIVADOS DEL PELIGRO
DE INCENDIO, EXPLOSIÓN, QUEMADURAS, ASFIXIA,
ENVENENAMIENTO CON MONÓXIDO DE CARBONO Y/O
DESCARGAS ELÉCTRICAS.
SOLO LAS PERSONAS QUE ENTIENDAN Y PUEDAN SEGUIR
LAS INSTRUCCIONES DEBEN USAR O MANTENER ESTE
CALENTADOR.
SI NECESITA AYUDA O INFORMACIÓN ACERCA DEL
CALENTADOR, COMO MANUALES DE INSTRUCCIONES,
ETIQUETAS, ETC., PÓNGASE EN CONTACTO CON
EL FABRICANTE.
EL ESTADO DE CALIFORNIA EXIGE LAS SIGUIENTES ADVERTENCIAS:
ADVERTENCIA: Uno de los elementos generados por la combustión al usar este equipo es el monóxido de
carbono, un producto químico que de acuerdo con el estado de California produce cáncer y defectos de nacimiento (u
otros daños reproductivos).
ADVERTENCIA: Este producto contiene sustancias químicas que de acuerdo con el estado de California
producen cáncer y defectos de nacimiento u otros daños reproductivos.
F-2
Appareil de chauffage au propane à air pulsé pour chantier de construction Guide d’utilisation et manuel du propriétaire
SPÉCIFICATIONS
Type de gaz : ......................... Pour une utilisation avec le propane
seulement
Pression de l'alimentation en gaz
au régulateur ....................... Max : 14,6 kg/cm
2
(200 l/po
2
)
(1 380 kPa)
Min : 0,35 kg/cm
2
(5 l/po
2
) (34,4 kPa)
sortie du régulateur ............. 991,44 cm (59 po) CE (14,70 kPa)
Pression du collecteur : .......... 134.6 cm (53 po) CE (13,20 kPa)
Entrée électrique : .................. 110/220 V, 50/60 Hz, 1Ø, 2A
Allumage : ............................. Auto-allumage/Valve manuelle de gaz
Contrôle de la flamme
primaire : ............................... Robinet de gaz à fonctionnement par
thermocouple
Contrôle de haute
température : ......................... 115
o
C (240
o
F)
Temp. ambiante min. Caractéristique
nominale -17,8 °C (0 °F)
Modèle : ............................... MH60CLP
Tension : ................................ 30 000 - 60 000 Btu/h
(8,79 – 17,58 kW)
Consommation
de carburant : ........................ 1,26 kg/h (1,6 no/h)
Taille de l'orifice
de carburant : ........................ 1,55 mm
Régime nominal
du ventilateur : ....................... 3,8 m
3
/min (135 pi
3
/min)
AVERTISSEMENT GÉNÉRAL DE DANGER :
LE NON-RESPECT DES MESURES DE PRÉVENTION ET
DES INSTRUCTIONS FOURNIES AVEC CET APPAREIL
DE CHAUFFAGE RISQUE DE CAUSER LA MORT, DES
BLESSURES GRAVES ET DES DOMMAGES OU DES PERTES
MATÉRIELLES RÉSULTANT D'INCENDIE, D'EXPLOSION, DE
BRÛLURE, D'ASPHYXIE, D'INTOXICATION AU MONOXYDE
DE CARBONE ET/OU D'ÉLECTROCUTION.
SEULES LES PERSONNES APTES À COMPRENDRE ET À
RESPECTER LES INSTRUCTIONS DEVRAIENT UTILISER OU
EFFECTUER LE SERVICE DE CET APPAREIL DE CHAUFFAGE.
SI VOUS AVEZ BESOIN D'ASSISTANCE OU D'INFORMATION
SUR L'APPAREIL DE CHAUFFAGE, COMME UN GUIDE
D'INSTRUCTIONS, DES ÉTIQUETTES, COMMUNIQUEZ AVEC
LE FABRICANT.
AVERTISSEMENT :
DANGER D'INCENDIE, D'INHALATION ET D'EXPLOSION.
GARDEZ LES COMBUSTIBLES SOLIDES TELS QUE LES
MATÉRIAUX DE CONSTRUCTION LE PAPIER ET LE
CARTON À UNE DISTANCE SÉCURITAIRE DE L'APPAREIL
DE CHAUFFAGE TEL QUE RECOMMANDÉ DANS LES
INSTRUCTIONS. N'UTILISEZ JAMAIS L'APPAREIL DE
CHAUFFAGE DANS UN ENDROIT QUI CONTIENT OU
RISQUE DE CONTENIR DES COMBUSTIBLES VOLATILES
OU EN SUSPENSION DANS L'AIR, OU DES PRODUITS
TELS QUE DE L'ESSENCE, DES SOLVANTS, DU DILUANT
À PEINTURE, DES PARTICULES DE POUSSIÈRE OU DES
PRODUITS CHIMIQUES INCONNUS.
AVERTISSEMENT :
NON CONÇU POUR UNE UTILISATION À L'INTÉRIEUR DE
LA MAISON OU DANS UN VÉHICULE RÉCRÉATIF.
AVERTISSEMENT :
VOTRE SÉCURITÉ EST IMPORTANTE POUR VOUS ET
POUR LES AUTRES, PAR CONSÉQUENT VEUILLEZ LIRE
CES DIRECTIVES AVANT DE FAIRE FONCTIONNER CET
APPAREIL DE CHAUFFAGE.
TABLE DES MATIÈRES
SPÉCIFICATIONS DE L'APPAREIL DE CHAUFFAGE ..........................F-2
AVERTISSEMENTS ........................................................................F-2
PRÉCAUTIONS LIÉES AU FONCTIONNEMENT ...............................F-3
PRÉCAUTIONS DE SÉCURITÉ ........................................................F-3
AVERTISSEMENT LIÉ AUX SUBSTANCES ODORANTES ..................F-4
PRÉPARATION POUR LE FONCTIONNEMENT ................................F-5
PROCÉDURE POUR LE CHARGEMENT DE LA BATTERIE .................F-5
INFORMATION CONCERNANT LA BATTERIE .................................F-5
INFORMATION POUR LE RECYCLAGE DE LA BATTERIE ................F-5
FONCTIONNEMENT DE L'APPAREIL DE CHAUFFAGE ....................F-6
ENTRETIEN ET ENTREPOSAGE ......................................................F-6
SERVICE .......................................................................................F-6
SCHÉMA DU CÂBLAGE ................................................................F-7
LISTE DES PIÈCES .........................................................................F-8
INFORMATION CONCERNANT LA TAILLE
ET LA CAPACITÉ DE PROPANE ......................................................F-9
INFORMATION SUR LA GARANTIE .............................................F-10
L'ÉTAT DE CALIFORNIE EXIGE QUE L'AVERTISSEMENT SUIVANT SOIT FOURNI :
AVERTISSEMENT : Les sous-produits de combustion émis lors de l'utilisation de cet appareil contiennent
du monoxyde de carbone, un produit chimique reconnu par l'état de Californie comme pouvant causer le cancer et des
malformations congénitales (ou autres dommages au système reproducteur).
AVERTISSEMENT : Cet appareil contient des produits chimiques reconnus par l'état de Californie comme
pouvant causer le cancer et des malformations congénitales ou autres dommages au système reproducteur.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Mr. Heater HEATSTAR MH35CLP Operating instructions

Category
Space heaters
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI