WIKA CPT-20 tag:model:CPT-21 Operating instructions

Category
Measuring, testing & control
Type
Operating instructions
Operating Instructions
Process pressure transmitter CPT-2x
Process pressure transmitter CPT-2x
Slave for electronic diî…°erential pressure
With SIL qualiî…²cation
Ceramic sensor
2
Contents
WIKA Operating Instructions - Process pressure transmitter CPT-2x
Contents
1 About this document ............................................................................................................... 4
1.1 Function ........................................................................................................................... 4
1.2 Target group ..................................................................................................................... 4
1.3 Symbols used................................................................................................................... 4
2 For your safety ......................................................................................................................... 5
2.1 Authorised personnel ....................................................................................................... 5
2.2 Appropriate use ................................................................................................................ 5
2.3 Warning about incorrect use ............................................................................................. 5
2.4 General safety instructions ............................................................................................... 5
2.5 EU conformity ................................................................................................................... 6
2.6 SIL qualiî…²cation according to IEC 61508 .......................................................................... 6
2.7 Permissible process conditions ........................................................................................ 6
2.8 Installation and operation in the USA and Canada ........................................................... 6
3 Product description ................................................................................................................. 7
3.1 Conî…²guration .................................................................................................................... 7
3.2 Principle of operation........................................................................................................ 8
3.3 Supplementary cleaning procedures .............................................................................. 13
3.4 Packaging, transport and storage ................................................................................... 13
4 Mounting ................................................................................................................................. 15
4.1 General instructions ....................................................................................................... 15
4.2 Ventilation and pressure compensation .......................................................................... 16
4.3 Combination Master - Slave ........................................................................................... 18
4.4 Level measurement ........................................................................................................ 19
4.5 Diî…°erential pressure measurement ................................................................................ 20
4.6 Interface measurement .................................................................................................. 21
4.7 Density measurement .................................................................................................... 22
4.8 Density-compensated level measurement ..................................................................... 23
4.9 External housing ............................................................................................................ 25
5 Connecting to power supply ................................................................................................. 26
5.1 Preparing the connection ............................................................................................... 26
5.2 Connecting ..................................................................................................................... 26
5.3 Single chamber housing ................................................................................................. 28
5.4 External housing with version IP 68 (25 bar)................................................................... 28
5.5 Connection example ...................................................................................................... 30
6 Functional safety (SIL) .......................................................................................................... 31
6.1 Objective ........................................................................................................................ 31
6.2 SIL qualiî…²cation .............................................................................................................. 31
6.3 Application area ............................................................................................................. 31
6.4 Safety concept of the parameterization .......................................................................... 32
7 Set up with the display and adjustment module ................................................................ 34
7.1 Parameter adjustment .................................................................................................... 34
8 Diagnosis, asset management and service ........................................................................ 48
8.1 Maintenance .................................................................................................................. 48
8.2 Cleaning - hygienic connection with compression nut .................................................... 48
8.3 Rectify faults ................................................................................................................... 49
3
Contents
WIKA Operating Instructions - Process pressure transmitter CPT-2x
8.4 Exchange process module on version IP 68 (25 bar) ..................................................... 49
8.5 Instrument repair ............................................................................................................ 50
9 Dismount................................................................................................................................. 51
9.1 Dismounting steps.......................................................................................................... 51
9.2 Disposal ......................................................................................................................... 51
10 Supplement ............................................................................................................................ 52
10.1 Technical data ................................................................................................................ 52
10.2 Calculation of the total deviation ..................................................................................... 62
10.3 Practical example ........................................................................................................... 63
10.4 Dimensions .................................................................................................................... 66
10.5 Trademark ...................................................................................................................... 74
Safety instructions for Ex areas
Take note of the Ex speciî…²c safety instructions for Ex applications.
These instructions are attached as documents to each instrument
with Ex approval and are part of the operating instructions.
Editing status: 2017-11-23
4
1 About this document
WIKA Operating Instructions - Process pressure transmitter CPT-2x
1 About this document
1.1 Function
This operating instructions provides all the information you need for
mounting, connection and setup as well as important instructions for
maintenance, fault rectiî…²cation, the exchange of parts and the safety
of the user. Please read this information before putting the instrument
into operation and keep this manual accessible in the immediate
vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained personnel.
The contents of this manual must be made available to the qualiî…²ed
personnel and implemented.
1.3 Symbols used
Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or malfunctions can result.
Warning: If this warning is ignored, injury to persons and/or serious
damage to the instrument can result.
Danger: If this warning is ignored, serious injury to persons and/or
destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
•
List
The dot set in front indicates a list with no implied sequence.
→
Action
This arrow indicates a single action.
1 Sequence of actions
Numbers set in front indicate successive steps in a procedure.
Battery disposal
This symbol indicates special information about the disposal of bat-
teries and accumulators.
5
2 For your safety
WIKA Operating Instructions - Process pressure transmitter CPT-2x
2 For your safety
2.1 Authorised personnel
All operations described in this documentation must be carried out
only by trained, qualiî…²ed personnel authorised by the plant operator.
During work on and with the device, the required personal protective
equipment must always be worn.
2.2 Appropriate use
CPT-2x is a slave sensor for electronic diî…°erential pressure measure-
ment.
You can î…²nd detailed information about the area of application in
chapter "Product description".
Operational reliability is ensured only if the instrument is properly
used according to the speciî…²cations in the operating instructions
manual as well as possible supplementary instructions.
2.3 Warning about incorrect use
Inappropriate or incorrect use of this product can give rise to applica-
tion-speciî…²c hazards, e.g. vessel overî…²ll through incorrect mounting
or adjustment. Damage to property and persons or environmental
contamination can result. Also, the protective characteristics of the
instrument can be impaired.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing
regulations and directives. The instrument must only be operated in a
technically î…´awless and reliable condition. The operator is responsi-
ble for the trouble-free operation of the instrument. When measuring
aggressive or corrosive media that can cause a dangerous situation
if the instrument malfunctions, the operator has to implement suitable
measures to make sure the instrument is functioning properly.
During the entire duration of use, the user is obliged to determine the
compliance of the necessary occupational safety measures with the
current valid rules and regulations and also take note of new regula-
tions.
The safety instructions in this operating instructions manual, the na-
tional installation standards as well as the valid safety regulations and
accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
trary conversions or modiî…²cations are explicitly forbidden. For safety
reasons, only the accessory speciî…²ed by the manufacturer must be
used.
To avoid any danger, the safety approval markings and safety tips on
the device must also be observed and their meaning read in this oper-
ating instructions manual.
6
2 For your safety
WIKA Operating Instructions - Process pressure transmitter CPT-2x
2.5 EU conformity
The device fulî…²ls the legal requirements of the applicable EU direc-
tives. By aî…±xing the CE marking, we conî…²rm the conformity of the
instrument with these directives.
2.6 SILqualicationaccordingtoIEC61508
The Safety Integrity Level (SIL) of an electronic system is used to as-
sess the reliability of integrated safety functions.
For detailed speciî…²cation of the safety requirements, multiple SIL
levels are speciî…²ed according to safety standard IEC 61508. You can
î…²nd detailed information in chapter "Functional safety (SIL)" of the
operating instructions.
The instrument meets the speciî…²cations of IEC 61508: 2010 (Edi-
tion 2). It is qualiî…²ed for single-channel operation up to SIL2. The
instrument can be used homogeneously redundant up to SIL3 in
multi-channel architecture with HFT 1.
2.7 Permissible process conditions
For safety reasons, the instrument must only be operated within the
permissible process conditions. You can î…²nd detailed information on
the process conditions in chapter "Technical data" as well as on the
type label.
The permissible process pressure range is speciî…²ed by "MWP"
(Maximum Working Pressure) on the type label, see chapter "Struc-
ture". The MWP takes the element of the measuring cell and process-
ing î…²tting combination with the weakest pressure into consideration
and may applied permanently. The speciî…²cation refers to a reference
temperature of +20 °C (+68 °F). It also applies when a measuring cell
with a higher measuring range than the permissible pressure range of
the process î…²tting is installed order-related.
In order to prevent damage to the device, the test pressure may only
exceed the speciî…²ed MWP brieî…´y by 1.5 times at reference tempera-
ture. The pressure stage of the process î…²tting as well as the overload
resistance of the measuring cell are taken into consideration here
(see chapter "Technical Data").
In addition, a temperature derating of the process î…²tting, e. g. with
î…´anges, can limit the permissible process pressure range according
to the respective standard.
2.8 Installation and operation in the USA and
Canada
This information is only valid for USA and Canada. Hence the follow-
ing text is only available in the English language.
Installations in the US shall comply with the relevant requirements of
the National Electrical Code (ANSI/NFPA 70).
Installations in Canada shall comply with the relevant requirements of
the Canadian Electrical Code.
7
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
3 Product description
3.1 Conguration
The scope of delivery encompasses:
•
Instrument CPT-2x - Slave sensor
•
Ready-made connection cable, unassembled cable gland
•
Documentation
– Quick setup guide CPT-2x
– Safety Manual (SIL)
– Documentation instrument parameters (default values)
– Documentation order-relating instrument parameters (deviation
from default values)
– Test certicate for pressure transmitters
– Instructions for optional instrument features
– Ex-specic "Safety instructions" (with Ex versions)
– If necessary, further certicates
Information:
Optional instrument features are also described in this operating
instructions manual. The respective scope of delivery results from the
order speciî…²cation.
This operating instructions manual applies to the following instrument
versions:
•
Hardware from 1.0.0
•
Software version from 1.0.0
Note:
You can î…²nd the hardware and software version of the instrument as
follows:
•
On the type plate of the electronics module
•
In the adjustment menu under "Info"
The type label contains the most important data for identiî…²cation and
use of the instrument:
Scope of delivery
Scope of this operating
instructions
Type label
8
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
4
1
5
10
12
11
13
14
3
2
6
7
8
9
Fig. 1: Layout of the type label (example)
1 Instrument type
2 Field for approvals
3 Signal output and voltage supply
4 Technical data
5 Product code
6 Order number
7 Serial number of the instrument
8 Symbol of the device protection class
9 ID numbers, instrument documentation
10 Reminder to observe the instrument documentation
11 SILidentication
3.2 Principle of operation
CPT-2x is suitable for applications in virtually all industries. It is used
for the measurement of the following pressure types.
•
Gauge pressure
•
Absolute pressure
•
Vacuum
Measured products are gases, vapours and liquids.
Depending on the process î…²tting and measurement setup, measured
products can be also viscous or contain abrasive substances.
The electronic diî…°erential pressure measurement is suitable for the
measurement of the following process variables:
•
Level
•
Flow
•
Diî…°erential pressure
•
Density
•
Interface
•
Level, density-compensated
The CPT-2x slave sensor is combined with a sensor from the instru-
ment series for electronic diî…°erential pressure measurement.
Application area
Measur
ed products
Measur
ed variables
Electronicdierential
pressure
9
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
1
2
Fig.2:Example,electronicdierentialpressureforlevelmeasurementinpres-
surized vessel
1 CPT-2x
2 CPT-2x, slave sensor
The sensors are connected via a screened four-wire cable. The
measured value from the slave sensor is read in and factored into the
calculations. Power supply and parameter adjustment are carried out
through the master sensor.
Information:
The sensor versions "Relative pressure climate-compensated" as
well as "Double chamber housing" are not suitable for connection of a
slave sensor.
You can î…²nd further information in chapter "Combination Master -
Slave " of this operating instructions.
To reach the Safety Integrity Level (SIL) for the electronic diî…°erential
pressure, both instruments must be SIL-qualiî…²ed.
Sensor element is the measuring cell with robust ceramic diaphragm.
The process pressure deî…´ects the ceramic diaphragm and causes a
capacitance change in the measuring cell. This capacitance change
is converted into an electrical signal and output as measured value
via the output signal.
Measuring system pres-
sure
10
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
16 µm
1
2
3
Fig.3:Congurationoftheceramicmeasuringcell
1 Process diaphragm
2 Glass joint
3 Base element
A temperature sensor in the ceramic diaphragm of the ø 28 mm or on
the ceramic base of the ø 17.5 mm measuring cell detects the actual
process temperature. The temperature value is output via the master
sensor.
Extreme process temperature jumps are also immediately detected
by the ø 28 mm measuring cell. The values are compared with that of
an additional temperature measurement on the ceramic base body.
Within only a few measuring cycles the intelligent sensor electronics
compensates unavoidable measurement deviations due to tempera-
ture shocks. Such shocks cause (depending on the set damping) only
slight, brief changes to the output signal.
Relative pressure: the measuring cell is open to the atmosphere.
The ambient pressure is detected in the measuring cell and compen-
sated. It thus has no inî…´uence on the measured value.
Absolute pressure: the measuring cell is evacuated and encapsu-
lated. The ambient pressure is not compensated and does hence
inî…´uence the measured value.
The following presentations show examples for the installation of the
ceramic measuring cell into the process î…²tting and the diî…°erent seal
concepts.
The recessed installation is particularly suitable for applications with
gases, vapours and clear liquids. The measuring cell seal is posi-
tioned laterally as well as in addition in front.
Measuring system tem-
per
ature
Pr
essure types
Seal concepts
Recessed installation
11
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
1
2
5
6
3
4
Fig. 4: Recessed installation of the measuring cell (example: manometer con-
nection G½)
1 Measuring cell
2 Seal for the measuring cell
3 Additional, front seal for measuring cell
4 Diaphragm
5 Processtting
6 Sealfortheprocesstting
The front-î…´ush installation is particularly suitable for applications with
viscous and abrasive media and in case of buildup. The measuring
cell seal is positioned laterally.
2
3
4
1
5
Fig.5:Front-ushinstallationofthemeasuringcell(example:threadG1½)
1 Sealfortheprocesstting
2 Measuring cell
3 Seal for the measuring cell
4 Processtting
5 Diaphragm
The completely front-î…´ush mounting is particularly suitable for ap-
plications in the paper industry. The diaphragm is in the pulp î…´ow, is
hence cleaned and protected against buildup.
Front-ushmountingwith
single seal
Completelyfront-ush
mounting with single seal
12
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
1
2
3
4
5
Fig.6:Front-ushinstallationofthemeasuringcell(example:M30x1.5)
1 Measuring cell
2 Seal for the measuring cell
3 Sealfortheprocesstting
4 Processtting
5 Diaphragm
The front-î…´ush installation is particularly suitable for applications with
viscous media. The additional, front sealing protects the glass joint
of the measuring cell against chemical attack and the measuring cell
electronics against diî…°usion of aggressive gases from the process.
1
2
3
4
5
Fig.7:Front-ushinstallationofthemeasuringcellwithdoubleseal(example:
angeconnectionwithextension)
1 Measuring cell
2 Seal for the measuring cell
3 Processtting
4 Additional, front seal for measuring cell
5 Diaphragm
The front-î…´ush, hygienic installation of the measuring cell is particu-
larly suitable for food applications. The sealings are installed gap-free.
The form seal of the measuring cell protects also the glass joint.
1
2
3
4
5
Fig.8:Hygienicinstallationofthemeasuringcell(example:hygienicttingwith
compression nut)
1 Measuring cell
2 Form seal for the measuring cell
3 Gap-freesealforprocesstting
4 Processtting
5 Diaphragm
Front-ushmountingwith
double seal
Installation in hygienic
î…²tting
13
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
The front-î…´ush, hygienic installation of the measuring cell acc. to 3A
is particularly suitable for food applications. The sealings are installed
gap-free. The additional front sealing for the measuring cell protects
also the glass joint. A hole in the process î…²tting is used for leakage
detection.
1
6
2
3
4
5
Fig. 9: Hygienic installation of the measuring cell acc. to 3-A (example: Clamp
connection)
1 Measuring cell
2 Seal for the measuring cell
3 Processtting
4 Additional, front seal for measuring cell
5 Diaphragm
5 Hole for leakage detection
3.3 Supplementary cleaning procedures
The CPT-2x is also available in the version "Oil, grease and silicone-
free". These instruments have passed through a special cleaning
procedure to remove oil, grease and paint-wetting impairment sub-
stances (PWIS).
The cleaning is carried out on all wetted parts as well as on surfaces
accessible from outside. To keep the purity level, the instruments are
immediately packed in plastic foil after the cleaning process. The
purity level remains as long as the instrument is kept in the closed
original packaging.
Caution:
The CPT-2x in this version may not be used in oxygen applications.
For this purpose, instruments are available in the special version "Oil
and grease-free for oxygen applications".
3.4 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging of standard instruments consists of environment-
friendly, recyclable cardboard. For special versions, PE foam or PE
foil is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.
Installation in hygienic
ttingacc.to3-A
Packaging
Transport
Transport inspection
14
3 Product description
WIKA Operating Instructions - Process pressure transmitter CPT-2x
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
•
Not in the open
•
Dry and dust free
•
Not exposed to corrosive media
•
Protected against solar radiation
•
Avoiding mechanical shock and vibration
•
Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
•
Relative humidity 20 … 85 %
With instrument weights of more than 18 kg (39.68 lbs) suitable and
approved equipment must be used for lifting and carrying.
Storage
Storage and transpor
t
temperature
Lifting and carrying
15
4 Mounting
WIKA Operating Instructions - Process pressure transmitter CPT-2x
4 Mounting
4.1 General instructions
Make sure before mounting that all parts of the instrument exposed to
the process are suitable for the existing process conditions.
These are mainly:
•
Active measuring component
•
Process î…²tting
•
Process seal
Process conditions in particular are:
•
Process pressure
•
Process temperature
•
Chemical properties of the medium
•
Abrasion and mechanical inî…´uences
You can î…²nd detailed information on the process conditions in chapter
"Technical data" as well as on the type label.
Protect your instrument against moisture ingress through the following
measures:
•
Use a suitable connection cable (see chapter "Connecting to
powersupply")
•
Tighten the cable gland or plug connector
•
When mounting horizontally, turn the housing so that the cable
gland or plug connector point downward
•
Lead the connection cable downward in front of the cable entry or
plug connector
This applies mainly to outdoor installations, in areas where high
humidity is expected (e.g. through cleaning processes) and on cooled
or heated vessels.
To maintain the housing protection, make sure that the housing lid is
closed during operation and locked, if necessary.
Make sure that the degree of contamination speciî…²ed in chapter
"Technical data" meets the existing ambient conditions.
On devices with a threaded î…²tting, the hexagon on the process î…²tting
must be tightened with a suitable wrench.
See chapter "Dimensions" for wrench size.
Warning:
The housing or the electrical connection may not be used for screw-
ing in! Tightening can cause damage, e. g. to the rotation mechanism
of the housing.
If there is strong vibration at the mounting location, the instrument
version with external housing should be used. See chapter "External
housing".
Process conditions
Pr
otection against mois-
ture
Scr
ewing in
Vibrations
16
4 Mounting
WIKA Operating Instructions - Process pressure transmitter CPT-2x
Higher process temperatures often mean also higher ambient
temperatures. Make sure that the upper temperature limits stated in
chapter "Technical data" for the environment of the electronics hous-
ing and connection cable are not exceeded.
1
2
Fig. 10: Temperature ranges
1 Process temperature
2 Ambient temperature
4.2 Ventilation and pressure compensation
The î…²lter element in the electronics housing has the following func-
tions:
•
Ventilation of the electronics housing
•
Atmospheric pressure compensation (with relative pressure meas-
uring ranges)
Caution:
The î…²lter element causes a time-delayed pressure compensation.
When quickly opening/closing the housing cover, the measured value
can change for approx. 5 s by up to 15 mbar.
For an eî…°ective ventilation, the î…²lter element must be always free from
buildup. In case of horizontal mounting, turn the housing so that the
î…²lter element points downward after the instrument is installed. This
provides better protection against buildup.
Caution:
Do not use a high-pressure cleaner. The î…²lter element could be dam-
aged, which would allow moisture into the housing.
The following paragraphs describe how the î…²lter element is arranged
in the diî…°erent instrument versions.
Temperature limits
Filter element - F
unction
17
4 Mounting
WIKA Operating Instructions - Process pressure transmitter CPT-2x
1 2 3
4 4 4
Fig.11:Positionofthelterelement-non-Ex,Ex-iaversion
1 Plastic, stainless steel housing (precision casting)
2 Aluminium housing
3 Stainless steel housing (electropolished)
4 Filter element
With the following instruments a blind plug is installed instead of the
î…²lter element:
•
Instruments in protection IP 66/IP 68 (1 bar) - ventilation via capil-
laries in non-detachable cable
•
Instruments with absolute pressure
→
Turn the metal ring in such a way that the î…²lter element points
downward after installation of the instrument. This provides better
protection against buildup.
1
2
Fig.12:Positionofthelterelement-Ex-dversion
1 Rotatable metal ring
2 Filter element
Instruments with absolute pressure have a blind plug mounted
instead of the î…²lter element.
The process assembly of instruments with Second Line of Defense
(gastight leadthrough) is completely encapsulated. An absolute pres-
sure measuring cell is used so that no ventilation is required.
Filter element - Position
Filter element - Position
Ex-d version
Instruments with Second
Line of De
fense
18
4 Mounting
WIKA Operating Instructions - Process pressure transmitter CPT-2x
1
2
Fig.13:Positionofthelterelement-gastightleadthrough
1 Filter element
1
Fig.14:Positionofthelterelement-IP69Kversion
1 Filter element
Instruments with absolute pressure have a blind plug mounted
instead of the î…²lter element.
4.3 Combination Master - Slave
In principle, any sensor combination within the instrument series is
allowed. The following requirements must be fulî…²lled:
•
Conî…²guration, Master sensor suitable for electronic diî…°erential
pressure
•
Pressure type is identical for both sensors, i.e. relative pressure/
relative pressure or absolute pressure/absolute pressure
•
Master sensor measures the higher pressure
•
Measurement setup as shown in the following chapters
The measuring range of each sensor is selected such that it î…²ts the
measuring loop. For this, the max. recommended turn down must be
noted. See chapter "Technical data". It is absolutely necessary the the
measuring ranges of Master and Slave correspond.
Measurement result = Measured value of Master (total pres-
sure) - measured value of Slave (static pressure)
Depending on the application, individual combinations can result, see
following examples:
Data
Application: Level measurement
Medium: Water
Filter element - Position
IP 69K version
Example - large vessel
19
4 Mounting
WIKA Operating Instructions - Process pressure transmitter CPT-2x
Vessel height: 12 m, hydrostatic pressure = 12 m x 1000 kg/m
3
x
9.81 m/s
2
= 117.7 kPa = 1.18 bar
Superimposed pressure: 1 bar
Total pressure: 1.18 bar + 1 bar = 2.18 bar
Instrument selection
Nominal measuring range Master: 2.5 bar
Nominal measuring range Slave: 1 bar
Turn Down: 2.5 bar/1.18 bar = 2.1 : 1
Data
Application: Level measurement
Medium: Water
Vessel height: 500 mm, hydrostatic pressure = 0.50 m x 1000 kg/m
3
x
9.81 m/s
2
= 4.9 kPa = 0.049 bar
Superimposed pressure: 350 mbar = 0.35 bar
Total pressure: 0.049 bar + 0.35 bar = 0.399 bar
Instrument selection
Nominal measuring range Master: 0.4 bar
Nominal measuring range Slave: 0.4 bar
Turn Down: 0.4 bar /0.049 bar = 8.2 : 1
Data
Application: Diî…°erential pressure measurement
Medium: Gas
Static pressure: 0.8 bar
Diî…°erential pressure on oriî…²ce: 50 mbar = 0.050 bar
Total pressure: 0.8 bar + 0.05 bar = 0.85 bar
Instrument selection
Nominal measuring range Master: 1 bar
Nominal measuring range Slave: 1 bar
Turn Down: 1 bar/0.050 bar = 20 : 1
The measuring result (level, pressure diî…°erence) as well as meas-
ured value Slave (static or superimposed pressure) are output by the
sensor. Depending on the instrument version, output as 4 … 20 mA
signal or digitally via HART, Proî…²bus PA or Foundation Fieldbus.
To reach the Safety Integrity Level (SIL) for the electronic diî…°erential
pressure, both instruments must be SIL-qualiî…²ed.
4.4 Level measurement
The master/slave combination is suitable for level measurement in a
pressurized vessel
Keep the following in mind when setting up the measuring system:
•
Mount the master sensor below the min. level
Example - small vessel
Example-oricein
pipeline
Output measured values
Measurement setup
20
4 Mounting
WIKA Operating Instructions - Process pressure transmitter CPT-2x
•
Do not mount the master sensor close to the î…²lling stream or
emptying area
•
Mount the master sensor so that it is protected against pressure
shocks from the stirrer
•
Mount the slave sensor above the max. level
1
2
Fig. 15: Measurement setup, level measurement in pressurized vessel
1 CPT-2x
2 CPT-2x, slave sensor
4.5 Dierentialpressuremeasurement
The master/slave combination is suitable for diî…°erential pressure
measurement
Take note of the following instructions for the measurement setup, for
example in gases:
•
Mount the instruments above the measuring point
Possible condensation can then drain oî…° into the process line.
Measurement setup
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

WIKA CPT-20 tag:model:CPT-21 Operating instructions

Category
Measuring, testing & control
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI