  • Hello! I am an AI chatbot trained to assist you with the H3C UniServer R6900 G3 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
H3C UniServer R6900 G3 Server
User Guide
New H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: 6W101-20191010
Copyright © 2018-2019, New H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written
consent of New H3C Technologies Co., Ltd.
Trademarks
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this
document are the property of their respective owners.
Notice
The information in this document is subject to change without notice. All contents in this document, including
statements, information, and recommendations, are believed to be accurate, but they are presented without
warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions
contained herein.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage, use,
and disposal of this product must meet the applicable national laws and regulations.
Preface
This preface includes the following topics about the documentation:
• Audience.
• Conventions.
• Documentation feedback.
Audience
This documentation is intended for:
• Network planners.
• Field technical support and servicing engineers.
• Server administrators working with the R6900 G3 Server.
Conventions
The following information describes the conventions used in the documentation.
Command conventions
Convention Description
Boldface Bold
text represents commands and keywords that you enter literally as shown.
Italic
Italic text represents arguments that you replace with actual values.
[ ] Square brackets enclose syntax choices (keywords or arguments) that are optional.
{ x | y | ... }
Braces enclose a set of required syntax choices separated by vertical bars, from which
you select one.
[ x | y | ... ]
Square brackets enclose a set of optional syntax choices separated by vertical bars,
from which you select one or none.
{ x | y | ... } *
Asterisk marked braces enclose a set of required syntax choices separated by vertical
bars, from which you select a minimum of one.
[ x | y | ... ] *
Asterisk marked square brackets enclose optional syntax choices separated by vertical
bars, from which you select one choice, multiple choices, or none.
&<1-n>
The argument or keyword and argument combination before the ampersand (&) sign
can be entered 1 to n times.
# A line that starts with a pound (#) sign is comments.
GUI conventions
Convention Description
Boldface
Window names, button names, field names, and menu items are in Boldface. For
example, the
New User
window opens; click
OK
.
>
Multi-level menus are separated by angle brackets. For example,
File
>
Create
>
Folder
.
Symbols
Convention Description
WARNING!
An alert that calls attention to important information that if not understood or followed
can result in personal injury.
CAUTION:
An alert that calls attention to important information that if not understood or followed
can result in data loss, data corruption, or damage to hardware or software.
IMPORTANT:
An alert that calls attention to essential information.
NOTE:
An alert that contains additional or supplementary information.
TIP:
An alert that provides helpful information.
Network topology icons
Convention Description
Represents a generic network device, such as a router, switch, or firewall.
Represents a routing-capable device, such as a router or Layer 3 switch.
Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that
supports Layer 2 forwarding and other Layer 2 features.
Represents an access controller, a unified wired-WLAN module, or the access
controller engine on a unified wired-WLAN switch.
Represents an access point.
Represents a wireless terminator unit.
Represents a wireless terminator.
Represents a mesh access point.
Represents omnidirectional signals.
Represents directional signals.
Represents a security product, such as a firewall, UTM, multiservice security
gateway, or load balancing device.
Represents a security module, such as a firewall, load balancing, NetStream, SSL
VPN, IPS, or ACG module.
Examples provided in this document
Examples in this document might use devices that differ from your device in hardware model,
configuration, or software version. It is normal that the port numbers, sample output, screenshots,
and other information in the examples differ from what you have on your device.
T
T
T
T




Documentation feedback
You can e-mail your comments about product documentation to [email protected].
We appreciate your comments.
i
Contents
1 Safety information ······································································· 1-1
Safety sign conventions ············································································································ 1-1
Power source recommendations ································································································ 1-1
Installation safety recommendations ··························································································· 1-2
General operating safety ···································································································· 1-2
Electrical safety ················································································································ 1-2
Rack mounting recommendations ························································································ 1-2
ESD prevention ················································································································ 1-3
Cooling performance ········································································································· 1-3
Battery safety ·················································································································· 1-4
2 Preparing for installation ······························································· 2-1
Rack requirements ·················································································································· 2-1
Installation site requirements ····································································································· 2-2
Space and airflow requirements ·························································································· 2-2
Temperature, humidity, and altitude requirements ··································································· 2-3
Cleanliness requirements ··································································································· 2-3
Grounding requirements ···································································································· 2-4
Installation tools ······················································································································ 2-4
3 Installing or removing the server ···················································· 3-1
Installing the server ················································································································· 3-1
Installing the chassis rails and slide rails ················································································ 3-1
Rack-mounting the server ·································································································· 3-1
(Optional) Installing the CMA ······························································································ 3-3
Connecting external cables ······································································································· 3-3
Cabling guidelines ············································································································ 3-3
Connecting a mouse, keyboard, and monitor ·········································································· 3-3
Connecting an Ethernet cable ····························································································· 3-5
Connecting a USB device ·································································································· 3-6
Connecting the power cord ································································································· 3-7
Securing cables ··············································································································· 3-9
Removing the server from a rack ······························································································ 3-10
4 Powering on and powering off the server ········································· 4-1
Important information ··············································································································· 4-1
Powering on the server ············································································································ 4-1
Prerequisites ··················································································································· 4-1
Procedure ······················································································································· 4-1
Powering off the server ············································································································ 4-2
Guidelines ······················································································································ 4-2
Procedure ······················································································································· 4-2
5 Configuring the server ································································· 5-1
Configuration flowchart············································································································· 5-1
Powering on the server ············································································································ 5-1
Configuring basic BIOS settings ································································································· 5-2
Setting the server boot order ······························································································· 5-2
Setting the BIOS passwords ······························································································· 5-2
Configuring RAID ···················································································································· 5-2
Installing the operating system and hardware drivers ······································································ 5-2
Installing the operating system ···························································································· 5-2
Installing hardware drivers ·································································································· 5-2
Updating firmware ··················································································································· 5-3
6 Installing hardware options ··························································· 6-1
Installing the security bezel ······································································································· 6-1
ii
Installing SAS/SATA drives ······································································································· 6-1
Installing NVMe drives ············································································································· 6-3
Installing power supplies ··········································································································· 6-4
Installing a compute module ······································································································ 6-5
Installing air baffles·················································································································· 6-7
Installing the low mid air baffle or GPU module air baffle to a compute module ······························ 6-7
Installing the GPU module air baffle to a rear riser card ···························································· 6-9
Installing riser cards and PCIe modules ····················································································· 6-11
Guidelines ···················································································································· 6-11
Installing a riser card and a PCIe module in a compute module ················································ 6-11
Installing riser cards and PCIe modules at the server rear ······················································· 6-13
Installing storage controllers and power fail safeguard modules ······················································ 6-17
Installing GPU modules ·········································································································· 6-21
Guidelines ···················································································································· 6-21
Installing a GPU module in a compute module ······································································ 6-21
Installing a GPU module to a rear riser card ········································································· 6-24
Installing Ethernet adapters ····································································································· 6-24
Guidelines ···················································································································· 6-24
Installing an mLOM Ethernet adapter ·················································································· 6-24
Installing a PCIe Ethernet adapter ······················································································ 6-26
Installing PCIe M.2 SSDs ········································································································ 6-27
Guidelines ···················································································································· 6-27
Installing a PCIe M.2 SSD in a compute module ··································································· 6-27
Installing a PCIe M.2 SSD at the server rear ········································································ 6-29
Installing SD cards ················································································································ 6-29
Installing an NVMe SSD expander module ················································································· 6-31
Installing the NVMe VROC module ··························································································· 6-32
Installing a drive backplane ····································································································· 6-32
Installing a diagnostic panel ···································································································· 6-33
Installing processors ·············································································································· 6-35
Installing DIMMs ··················································································································· 6-39
Guidelines ···················································································································· 6-40
Procedure ····················································································································· 6-43
Installing and setting up a TCM or TPM ····················································································· 6-45
Installation and setup flowchart ························································································· 6-45
Installing a TCM or TPM ·································································································· 6-45
Enabling the TCM or TPM in the BIOS ················································································ 6-47
Configuring encryption in the operating system ····································································· 6-47
7 Replacing hardware options ·························································· 7-1
Replacing the security bezel ······································································································ 7-1
Replacing a SAS/SATA drive ····································································································· 7-1
Replacing an NVMe drive ········································································································· 7-2
Replacing a compute module and its main board ··········································································· 7-3
Removing a compute module ······························································································ 7-3
Removing the main board of a compute module ······································································ 7-4
Installing a compute module and its main board ······································································ 7-5
Verifying the replacement ··································································································· 7-7
Replacing access panels ·········································································································· 7-7
Replacing a compute module access panel ············································································ 7-7
Replacing the chassis access panel ····················································································· 7-8
Replacing a power supply ········································································································· 7-9
Replacing air baffles ·············································································································· 7-11
Replacing air baffles in a compute module ··········································································· 7-11
Replacing the power supply air baffle·················································································· 7-13
Replacing a riser card air baffle ························································································· 7-14
Replacing a riser card and a PCIe module ·················································································· 7-16
Replacing the riser card and PCIe module in a compute module ·············································· 7-16
Replacing a riser card and PCIe module at the server rear ······················································ 7-17
Replacing a storage controller ································································································· 7-19
Guidelines ···················································································································· 7-20
Preparing for replacement ································································································ 7-20
iii
Procedure ····················································································································· 7-20
Verifying the replacement ································································································· 7-21
Replacing the power fail safeguard module for a storage controller ·················································· 7-21
Replacing a GPU module ······································································································· 7-23
Replacing the GPU module in a compute module ·································································· 7-23
Replacing a GPU module at the server rear ········································································· 7-24
Replacing an Ethernet adapter ································································································· 7-24
Replacing an mLOM Ethernet adapter ················································································ 7-25
Replacing a PCIe Ethernet adapter ···················································································· 7-26
Replacing an M.2 transfer module and a PCIe M.2 SSD ································································ 7-26
Replacing the M.2 transfer module and a PCIe M.2 SSD in a compute module ···························· 7-26
Replacing an M.2 transfer module and a PCIe M.2 SSD at the server rear·································· 7-28
Replacing an SD card ············································································································ 7-28
Replacing the dual SD card extended module ············································································· 7-29
Replacing an NVMe SSD expander module ················································································ 7-30
Replacing the NVMe VROC module ·························································································· 7-31
Replacing a fan module ·········································································································· 7-32
Replacing a processor ··········································································································· 7-34
Guidelines ···················································································································· 7-34
Prerequisites ················································································································· 7-34
Removing a processor ····································································································· 7-34
Installing a processor ······································································································ 7-36
Verifying the replacement ································································································· 7-37
Replacing a DIMM················································································································· 7-37
Replacing the system battery ··································································································· 7-38
Removing the system battery ···························································································· 7-39
Installing the system battery ····························································································· 7-39
Verifying the replacement ································································································· 7-40
Replacing drive backplanes ····································································································· 7-40
Replacing the management module ·························································································· 7-41
Removing the management module ··················································································· 7-41
Installing the management module ····················································································· 7-42
Replacing the PDB ················································································································ 7-42
Removing the PDB ········································································································· 7-43
Installing the PDB ··········································································································· 7-44
Replacing the midplane ·········································································································· 7-46
Removing the midplane ··································································································· 7-46
Installing the midplane ····································································································· 7-47
Replacing the diagnostic panel ································································································ 7-48
Replacing chassis ears ·········································································································· 7-48
Replacing the TPM/TCM ········································································································ 7-50
8 Connecting internal cables ···························································· 8-1
Connecting drive cables ··········································································································· 8-1
Connecting drive cables in compute modules ········································································· 8-1
Storage controller cabling in riser cards at the server rear ························································· 8-5
Connecting the flash card on a storage controller ··········································································· 8-8
Connecting the GPU power cord ································································································ 8-9
Connecting the NCSI cable for a PCIe Ethernet adapter ································································ 8-10
Connecting the front I/O component cable from the right chassis ear ··············································· 8-11
Connecting the cable for the front VGA and USB 2.0 connectors on the left chassis ear ······················· 8-11
9 Maintenance ·············································································· 9-1
Guidelines ····························································································································· 9-1
Maintenance tools ··················································································································· 9-1
Maintenance tasks ·················································································································· 9-1
Observing LED status ······································································································· 9-1
Monitoring the temperature and humidity in the equipment room ················································ 9-1
Examining cable connections ······························································································ 9-2
Technical support ··················································································································· 9-2
iv
10 Appendix A Server specifications ··············································· 10-1
Server models and chassis view ······························································································ 10-1
Technical specifications ·········································································································· 10-2
Components ························································································································ 10-3
Front panel ·························································································································· 10-4
Front panel view of the server ··························································································· 10-4
Front panel view of a compute module ················································································ 10-6
LEDs and buttons ··········································································································· 10-7
Ports···························································································································· 10-8
Rear panel ·························································································································· 10-9
Rear panel view ············································································································· 10-9
LEDs ··························································································································· 10-9
Ports··························································································································· 10-11
Main board of a compute module ···························································································· 10-11
Main board components ································································································· 10-11
DIMM slots ··················································································································· 10-12
Management module ············································································································ 10-13
Management module components ···················································································· 10-13
System maintenance switches ························································································· 10-14
PDB ·································································································································· 10-15
11 Appendix B Component specifications ········································ 11-1
About component model names ······························································································· 11-1
Software compatibility ············································································································ 11-1
Processors ·························································································································· 11-1
Intel processors ············································································································· 11-1
Jintide-C series processors ······························································································ 11-3
DIMMs ································································································································ 11-3
DRAM specifications ······································································································· 11-3
DCPMM specifications ···································································································· 11-4
DRAM DIMM rank classification label ················································································· 11-4
HDDs and SSDs ··················································································································· 11-5
Drive specifications ········································································································· 11-5
Drive LEDs ··················································································································· 11-8
Drive configurations and numbering ··················································································· 11-9
PCIe modules ····················································································································· 11-14
Storage controllers ········································································································ 11-15
NVMe SSD expander modules ························································································· 11-20
GPU modules ··············································································································· 11-20
PCIe Ethernet adapters ·································································································· 11-22
FC HBAs ····················································································································· 11-23
mLOM Ethernet adapters ······································································································· 11-26
Riser cards ························································································································· 11-26
Riser card guidelines ······································································································ 11-27
RS-FHHL-G3 ················································································································ 11-27
RS-GPU-R6900-G3 ······································································································· 11-27
RS-4*FHHL-G3 ············································································································· 11-28
RS-6*FHHL-G3-1 ·········································································································· 11-29
RS-6*FHHL-G3-2 ·········································································································· 11-30
Riser card and system board port mapping relationship ························································· 11-31
Fan modules ······················································································································· 11-32
Air baffles ··························································································································· 11-33
Compute module air baffles ····························································································· 11-33
Power supply air baffle ··································································································· 11-34
Rear riser card air baffles ································································································ 11-34
Power supplies ···················································································································· 11-35
800 W power supply ······································································································ 11-35
800 W high-voltage power supply ····················································································· 11-35
1200 W power supply ····································································································· 11-36
1600 W power supply ····································································································· 11-36
850 W high-efficiency Platinum power supply ······································································ 11-37
v
Expander modules ··············································································································· 11-37
Diagnostic panels················································································································· 11-38
Diagnostic panel specifications ························································································· 11-38
Diagnostic panel view ····································································································· 11-38
LEDs ·························································································································· 11-38
Fiber transceiver modules ······································································································ 11-42
Storage options other than HDDs and SDDs ·············································································· 11-42
NVMe VROC modules ·········································································································· 11-42
TPM/TCM modules ·············································································································· 11-42
Compute modules ················································································································ 11-43
Security bezels, slide rail kits, and CMA ···················································································· 11-43
12 Appendix C Managed hot removal of NVMe drives ························ 12-1
Performing a managed hot removal in Windows ·········································································· 12-1
Prerequisites ················································································································· 12-1
Procedure ····················································································································· 12-1
Performing a managed hot removal in Linux ··············································································· 12-2
Prerequisites ················································································································· 12-2
Performing a managed hot removal from the CLI ·································································· 12-2
Performing a managed hot removal from the Intel
®
ASM Web interface ····································· 12-3
13 Appendix D Environment requirements ······································· 13-1
About environment requirements ······························································································ 13-1
General environment requirements ··························································································· 13-1
Operating temperature requirements ························································································· 13-1
14 Appendix E Product recycling ··················································· 14-1
15 Appendix F Glossary ······························································· 15-1
16 Appendix G Acronyms ····························································· 16-1
1-1
1 Safety information
Safety sign conventions
To avoid bodily injury or damage to the server or its components, make sure you are familiar with the
safety signs on the server chassis or its components.
Table 1-1 Safety signs
Sign Description
Circuit or electricity hazards are present. Only H3C authorized or professional
server engineers are allowed to service, repair, or upgrade the server.
WARNING!
To avoid bodily injury or damage to circuits, do not open any components marked
with the electrical hazard sign unless you have authorization to do so.
Electrical hazards are present. Field servicing or repair is not allowed.
WARNING!
To avoid bodily injury, do not open any components with the field-servicing
forbidden sign in any circumstances.
The surface or component might be hot and present burn hazards.
WARNING!
To avoid being burnt, allow hot surfaces or components to cool before touching
them.
The server or component is heavy and requires more than one people to carry or
move.
WARNING!
To avoid bodily injury or damage to hardware, do not move a heavy component
alone. In addition, observe local occupational health and safety requirements and
guidelines for manual material handling.
The server is powered by multiple power supplies.
WARNING!
To avoid bodily injury from electrical shocks, make sure you disconnect all power
supplies if you are performing offline servicing.
Power source recommendations
Power instability or outage might cause data loss, service disruption, or damage to the server in the
worst case.
To protect the server from unstable power or power outage, use uninterrupted power supplies (UPSs)
to provide power for the server.
1-2
Installation safety recommendations
To avoid bodily injury or damage to the server, read the following information carefully before you
operate the server.
General operating safety
To avoid bodily injury or damage to the server, follow these guidelines when you operate the server:
• Only H3C authorized or professional server engineers are allowed to install, service, repair,
operate, or upgrade the server.
• Make sure all cables are correctly connected before you power on the server.
• Place the server on a clean, stable table or floor for servicing.
• To avoid being burnt, allow the server and its internal modules to cool before touching them.
Electrical safety
WARNING!
If you put the server in standby mode (system LED in amber) with the power on/standby button on
the front panel, the power supplies continue to supply power to some circuits in the server. To
remove all power for servicing safety, you must first press the button until the system LED turns into
steady amber, and then remove all power cords from the server.
To avoid bodily injury or damage to the server, follow these guidelines:
• Always use the power cords that came with the server.
• Do not use the power cords that came with the server for any other devices.
• Power off the server when installing or removing any components that are not hot swappable.
Rack mounting recommendations
To avoid bodily injury or damage to the equipment, follow these guidelines when you rack mount a
server:
• Mount the server in a standard 19-inch rack.
• Make sure the leveling jacks are extended to the floor and the full weight of the rack rests on the
leveling jacks.
• Couple the racks together in multi-rack installations.
• Load the rack from the bottom to the top, with the heaviest hardware unit at the bottom of the
rack.
• Get help to lift and stabilize the server during installation or removal, especially when the server
is not fastened to the rails. As a best practice, a minimum of four people are required to safely
load or unload a rack. A fifth person might be required to help align the server if the server is
installed higher than check level.
• For rack stability, make sure only one unit is extended at a time. A rack might get unstable if
more than one server unit is extended.
• Make sure the rack is stable when you operate a server in the rack.
• To maintain correct airflow and avoid thermal damage to the server, use blanks to fill empty rack
units.
1-3
ESD prevention
Electrostatic charges that build up on people and tools might damage or shorten the lifespan of
boards, the midplane, and electrostatic-sensitive components.
Preventing electrostatic discharge
To prevent electrostatic damage, follow these guidelines:
• Transport or store the server with the components in antistatic bags.
• Keep the electrostatic-sensitive components in the antistatic bags until they arrive at an
ESD-protected area.
• Place the components on a grounded surface before removing them from their antistatic bags.
• Avoid touching pins, leads, or circuitry.
• Make sure you are reliably grounded when touching an electrostatic-sensitive component or
assembly.
Grounding methods to prevent electrostatic discharge
The following are grounding methods that you can use to prevent electrostatic discharge:
• Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
• Take adequate personal grounding measures, including wearing antistatic clothing, static
dissipative shoes, and antistatic gloves.
• Use conductive field service tools.
• Use a portable field service kit with a folding static-dissipating work mat.
Cooling performance
Poor cooling performance might result from improper airflow and poor ventilation and might cause
damage to the server.
To ensure good ventilation and proper airflow, follow these guidelines:
• Install blanks if the following module slots are empty:
{ Compute module slots.
{ Drive bays.
{ Rear riser card bays.
{ PCIe slots.
{ Power supply slots.
• Do not block the ventilation openings in the server chassis.
• To avoid thermal damage to the server, do not operate the server for long periods in any of the
following conditions:
{ Access panel open or uninstalled.
{ Air baffles uninstalled.
{ Riser cards uninstalled.
{ PCIe slots, drive bays, or power supply slots empty.
• If the server is stacked in a rack with other devices, make sure there is a minimum clearance of
2 mm (0.08 in) below and above the server.
1-4
Battery safety
The server's management module contains a system battery, which is designed with a lifespan of 5
to 10 years.
If the server no longer automatically displays the correct date and time, you might need to replace
the battery. When you replace the battery, follow these safety guidelines:
• Do not attempt to recharge the battery.
• Do not expose the battery to a temperature higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or
water.
• Dispose of the battery at a designated facility. Do not throw the battery away together with other
wastes.
2-1
2 Preparing for installation
Prepare a rack that meets the rack requirements and plan an installation site that meets the
requirements of space and airflow, temperature, humidity, equipment room height, cleanliness, and
grounding.
Rack requirements
IMPORTANT:
As a best practice to avoid affecting the server chassis, install power distribution units (PDUs) with
the outputs facing backwards. If you install PDUs with the outputs facing the inside of the server,
please perform onsite survey to make sure the cables won't affect the server rear.
The server is 4U high. The rack for installing the server must meet the following requirements:
• A standard 19-inch rack.
• A clearance of more than 50 mm (1.97 in) between the rack front posts and the front rack door.
• A minimum of 1200 mm (47.24 in) in depth as a best practice. For installation limits for different
rack depth, see Table 2-1.
Table 2-1
Installation limits for different rack depths
Rack depth Installation limits
1000 mm
(39.37 in)
• H3C cable management arm (CMA) is not supported.
• A clearance of 60 mm (2.36 in) is reserved from the server rear to the rear rack
door for cabling.
• The slide rails and PDUs might hinder each other. Perform onsite survey to
determine the PDU installation location and the proper PDUs. If the PDUs hinder
the installation and movement of the slide rails anyway, use other methods to
support the server, a tray for example.
1100 mm
(43.31 in)
Make sure the CMA does not hinder PDU installation at the server rear before
installing the CMA. If the CMA hinders PDU installation, use a deeper rack or change
the installation locations of PDUs.
1200 mm
(47.24 in)
Make sure the CMA does not hinder PDU installation or cabling. If the CMA hinders
PDU installation or cabling, change the installation locations of PDUs.
For detailed installation suggestions, see Figure 2-1.
2-2
Figure 2-1 Installation suggestions for a 1200 mm deep rack (top view)
(1) 1200 mm (47.24 in) rack depth
(2) A minimum of 50 mm (1.97 in) between the rack front posts and the front rack door
(3) 830 mm (32.68 in) between the rack front posts and the rear of the chassis, including power supply
handles at the server rear (not shown in the figure)
(4) 830 mm (32.68 in) server depth, including chassis ears
(5) 950 mm (37.40 in) between the front rack posts and the CMA
(6) 860 mm (33.86 in) between the front rack posts and the rear ends of the slide rails
Installation site requirements
Space and airflow requirements
For convenient maintenance and heat dissipation, make sure the following requirements are met:
• The passage for server transport is a minimum of 1500 mm (59.06 in) wide.
• A minimum clearance of 1200 mm (47.24 in) is reserved from the front of the rack to the front of
another rack or row of racks.
• A minimum clearance of 800 mm (31.50 in) is reserved from the back of the rack to the rear of
another rack or row of racks.
• A minimum clearance of 1000 mm (39.37 in) is reserved from the rack to any wall.
2-3
• The air intake and outlet vents of the server are not blocked.
• The front and rear rack doors are adequately ventilated to allow ambient room air to enter the
cabinet and allow the warm air to escape from the cabinet.
• The air conditioner in the equipment room provides sufficient air flow for heat dissipation of
devices in the room.
Figure 2-2 Airflow through the server
(1) to (8) Directions of the airflow into the chassis and power supplies
(9) to (10) Directions of the airflow out of the chassis
Temperature, humidity, and altitude requirements
To ensure correct operation of the server, make sure the room temperature, humidity, and altitude
meet the requirements as described in "Appendix C Environment requirements."
Cleanliness requirements
Mechanically active substances buildup on the chassis might result in electrostatic adsorption, which
causes poor contact of metal components and contact points. In the worst case, electrostatic
adsorption can cause communication failure.
Table 2-2 Mechanically active substance concentration limit in the equipment room
Substance Particle diameter Concentration limit
Dust particles ≥ 5 µm
≤ 3 x 10
4
particles/m
3
(No visible dust on desk in three days)
Dust (suspension) ≤ 75 µm ≤ 0.2 mg/m
3
Dust
(sedimentation)
75 µm to 150 µm ≤ 1.5 mg/(m
2
h)
Sand ≥ 150 µm ≤ 30 mg/m
3
The equipment room must also meet limits on salts, acids, and sulfides to eliminate corrosion and
premature aging of components, as shown in Table 2-3.
2-4
Table 2-3 Harmful gas limits in an equipment room
Gas Maximum concentration (mg/m
3
)
SO
2
0.2
H
2
S 0.006
NO
2
0.04
NH
3
0.05
Cl
2
0.01
Grounding requirements
Correctly connecting the server grounding cable is crucial to lightning protection, anti-interference,
and ESD prevention. The server can be grounded through the grounding wire of the power supply
system and no external grounding cable is required.
Installation tools
Table 2-4 lists the tools that you might use during installation.
Table 2-4 Installation tools
Picture Name Description
T25 Torx screwdriver For captive screws inside chassis ears.
T30 Torx screwdriver
(Electric screwdriver)
For captive screws on processor heatsinks.
T15 Torx screwdriver
(shipped with the server)
For replacing the management module.
T10 Torx screwdriver
(shipped with the server)
For screws on PCIe modules.
Flat-head screwdriver For replacing processors or the management module.
Phillips screwdriver For screws on PCIe M.2 SSDs.
Cage nut insertion/extraction
tool
For insertion and extraction of cage nuts in rack posts.
Diagonal pliers For clipping insulating sleeves.
Tape measure For distance measurement.
2-5
Picture Name Description
Multimeter For resistance and voltage measurement.
ESD wrist strap For ESD prevention when you operate the server.
Antistatic gloves For ESD prevention when you operate the server.
Antistatic clothing For ESD prevention when you operate the server.
Ladder For high-place operations.
Interface cable (such as an
Ethernet cable or optical
fiber)
For connecting the server to an external network.
Monitor (such as a PC) For displaying the output from the server.
3-1
3 Installing or removing the server
Installing the server
As a best practice, install hardware options to the server (if needed) before installing the server in the
rack. For more information about how to install hardware options, see "Installing hardware options."
Installing the chassis rails and slide rails
Install the chassis rails to the server and the slide rails to the rack. For information about installing the
rails, see the installation guide shipped with the rails.
Rack-mounting the server
WARNING!
To avoid bodily injury, slide the server into the rack with caution for the sliding rails might squeeze
your fingers.
1. Remove the screws from both sides of the server, as shown in Figure 3-1.
Figure 3-1 Removing the screws from both sides of the server
2. Remove the security bezel, if any. For more information, see "Replacing the security bezel."
3. (Optional.) Remove the compute modules if the server is too heavy for mounting. For more
information, see "Removing a compute module."
4. Install the chassis handles. For more information, see the labels on the handles.
5. Lift the server and slide the server into the rack along the slide rails, as shown in Figure 3-2.
Remove
the chassis handles as you slide the server into the rack. For more information, see the
labels on the handles.
/