CEM Star Owner's manual

Type
Owner's manual
Corporation
Operation Manual
i
Operation Manual
STAR Plus System 2™
and
STAR Plus System 6™
Copyright 2001 by CEM Corporation
All Rights Reserved
This manual contains proprietary information which shall not be reproduced
or transferred to other documents or disclosed to others
without prior written permission of CEM Corporation.
CEM is a registered trademark of CEM Corporation.
US Patent No. 5,796,080
titled “Microwave Apparatus for Controlling Power Levels
in Individual Multiple Cells”
CEM Corporation
Matthews, North Carolina 28106
(704) 821-7015 FAX: 704-821-7894
MANUFACTURED IN THE
UNITED STATES OF AMERICA
600127
Rev. 0
9/2001
ii
Operating Precautions
The STAR System 2/6 must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by
providing an escape wire for electric current. This instrument is equipped with a cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is properly installed and grounded. Consult a qualifi ed electrician or service
technician if the grounding instructions are not completely understood or if doubt exists as to whether the instrument is properly
grounded. If it is necessary to use an extension cord, use only a 3-wire extension cord that has a 3-blade grounding plug and
a 3-slot receptacle that will accept the plug from the instrument. The marked rating of the extension cord must be equal to or
greater than the electrical rating of the instrument.
The possibility of instrument-induced electromagnetic interference (EMI) is minimal if the instrument is operated as outlined
in this manual. The instrument should not be placed close to any electrical device susceptible to EMI. It is suggested by the
manufacturer that the user post a sign warning pacemaker wearers that a microwave device is in operation. If the instrument is
suspected of inducing EMI, a microwave leakage measurement should be performed as outlined in this manual. Leakage measured
above the legal limit of 5 mW/cm 2 should be reported to the CEM Service Department.
This instrument utilizes high voltages and microwave radiation. Instrument service and repair should be performed only by those
trained in repair and maintenance of high voltage and microwave power systems.
Warnings, cautions and notes are included throughout this manual and should be read thoroughly and strictly followed.
WARNING: A warning is inserted for essential information used to empha-size dangerous or hazardous conditions to the
operation, cleaning and maintenance of the instrument which may result in personal injury.
CAUTION: A caution is inserted for essential information used to emphasize procedures which, if not strictly followed, may
result in damage or destruction to the instrument or improper instrument operation.
NOTE: A note is inserted for emphasis of procedures or conditions which may otherwise be misinterpreted or overlooked and
to clarify possible confusing situations.
This instrument complies with United States Code of Federal Regulations (CFR) Title 21, Part 1030 for microwave leakage.
A veri cation report is on le.
This instrument complies with United States Code of Federal Regulations (CFR) Title 47, Federal Communications Commission
(FCC) Part 18 Industrial, Scienti c and Medical (ISM) Equipment emissions requirements. A veri cation report is on le.
The name Te on is used throughout this manual. Te on is a registered trademark of the E.I. DuPont Company.
iii
Table of Contents
Introduction ....................................................................................................................................................................................... 1
Installation ......................................................................................................................................................................................... 3
Tools Required .................................................................................................................................................................................. 3
Accessories Required......................................................................................................................................................................... 3
Installation.......................................................................................................................................................................................... 3
Unpacking System Components........................................................................................................................................................ 4
Instrument Inspection......................................................................................................................................................................... 6
Instrument Description....................................................................................................................................................................... 7
Instrument.................................................................................................................................................................................... 9
Keyboard ................................................................................................................................................................................... 11
Component Installation.................................................................................................................................................................... 12
General Safety.................................................................................................................................................................................. 16
Compounds Unsuitable for Open Cavity Microwave Digestion ..................................................................................................... 17
System Cautions .............................................................................................................................................................................. 18
Instrument Setup .............................................................................................................................................................................. 19
Reagent Volume......................................................................................................................................................................... 19
Auto Print .................................................................................................................................................................................. 19
Clear Method ............................................................................................................................................................................. 20
Printer Setup .............................................................................................................................................................................. 20
Change Reagent Name .............................................................................................................................................................. 21
Set Clock ................................................................................................................................................................................... 22
Calibrate Temperature ............................................................................................................................................................... 22
Set Overtime.............................................................................................................................................................................. 24
Maximum System Temperature................................................................................................................................................. 24
Software Version........................................................................................................................................................................ 24
Program/Edit Method....................................................................................................................................................................... 25
Reagent Volume......................................................................................................................................................................... 25
Select Vessel .............................................................................................................................................................................. 25
Change Method Name............................................................................................................................................................... 25
Update Initial Reagent............................................................................................................................................................... 25
Reagent Volume......................................................................................................................................................................... 26
Stage .......................................................................................................................................................................................... 27
Evaporation Stage...................................................................................................................................................................... 27
Ramp Time ................................................................................................................................................................................ 28
Temperature Target .................................................................................................................................................................... 28
Time at Temperature.................................................................................................................................................................. 28
Update Reagent ......................................................................................................................................................................... 28
Reagent Volume......................................................................................................................................................................... 29
Prime Method................................................................................................................................................................................... 30
Instrument Operation ....................................................................................................................................................................... 31
Pause Method ............................................................................................................................................................................ 31
Stop Method .............................................................................................................................................................................. 31
Insuf cient Reagent................................................................................................................................................................... 32
Manual Reagent Addition (Must Use for HF) ........................................................................................................................... 32
In-Process Reagent Addition ..................................................................................................................................................... 34
Method Completed .................................................................................................................................................................... 34
Print ........................................................................................................................................................................................... 35
Routine Maintenance, Troubleshooting and Service ....................................................................................................................... 37
Routine Maintenance................................................................................................................................................................. 38
Routine Maintenance Schedule ................................................................................................................................................. 38
Reagent Pump Flush.................................................................................................................................................................. 39
Scrubber Solution Replacement ................................................................................................................................................ 39
Microwave Leakage Measurement............................................................................................................................................ 40
Calibrate Temperature ............................................................................................................................................................... 40
Veri cation of Temperature Calibration .................................................................................................................................... 41
Troubleshooting Chart ............................................................................................................................................................... 44
iv
Table of Contents (Continued)
Error Messages .......................................................................................................................................................................... 47
Service ....................................................................................................................................................................................... 49
Spill Removal....................................................................................................................................................................... 50
Vessel Liner Replacement.................................................................................................................................................... 52
Reagent Delivery Con rmation ........................................................................................................................................... 53
Diaphragm Replacement - Single Head Vacuum Pump ...................................................................................................... 54
Diaphragm & Valve Replacement - Dual Head Vacuum Pump........................................................................................... 56
Pump Replacement .............................................................................................................................................................. 59
Speci cations ................................................................................................................................................................................... 63
Emissions and Safety Approvals ............................................................................................................................................... 64
Warranty .................................................................................................................................................................................... 65
1
Introduction
STAR Plus System 2 and STAR Plus System 6 are designed for laboratory use in digesting, dissolving, hydrolyzing, leaching,
or evaporating a wide range of materials. Their primary purpose is the rapid preparation of samples for analysis by atomic
absorption (AA) and inductively coupled plasma (ICP) emission spectroscopy and gas or liquid chromatography. The STAR
systems are a breakthrough in microwave technology. The technology permits multiple cavities to operate independently with
individual methods and temperature feedback control. Thus, the STAR System 6 can digest up to six samples simultaneously or
with staggered start times. The unique design incorporates a single magnetron, which generates microwave energy for the entire
system. Microwaves are directed through a waveguide with up to six cavities positioned along its length. A microwave slot is
positioned between the waveguide and each cavity. When the slot is open, microwaves enter the cavity; when the slot is closed,
microwaves cannot enter the cavity. Simultaneous temperature feedback is obtained from all cavities; therefore, microwave energy
is supplied to each cavity based on the needs of the sample. The innovative STAR technology systems are either two or six
individual microwave cavities. A sample placed inside a microwave-transparent vessel with a polar liquid or ionic solution
(usually an acid) is subjected to rapid heating, causing the sample to rapidly digest or dissolve. Each cavity is independent,
permitting simultaneous performance of up to six different methods. With the temperature automatically controlled, the STAR
systems ensure consistent and reproducible results for each digestion in each cavity. Large sample sizes can be digested, achieving
lower detection limits and simplifying preparation for trace metals analyses. Other dif cult or problem samples, including highly
reactive materials, can also be readily digested. An automated reagent addition, with up to four reagents, is available as an option.
The reagent addition module eliminates operator handling of the reagents and constant monitoring of the system operation.
WARNING
Do not use the automated reagent addition for pumping hydro uoric acid (HF). HF must be added manually or
with the CEM HF Pumping Station.
Each system is equipped with a vapor containment module to treat the vapors produced during the digestion process.
2
3
Installation
For use with all reagents other than hydro uoric acid, the STAR System 2/6 should be installed on a laboratory work bench
with access to a fume hood or other means of fume disposal. For use with hydro uoric acid, the STAR System must be installed
in a fume hood.
Tools Required
Flat Blade Screwdriver
#2 Phillips Screwdriver
Pliers
Lab Coat
Gloves
Eye Protection
Accessories Required
Waste Container (bottle)
Reagents (i.e. HNO3 , H2 SO4 , H2 O2 , and HCl)
Containers for Reagents (up to 4)
Installation
To install the STAR System 2/6 , follow the procedures outlined below. Choose a location for instrument installation that:
1. provides at least 8 in. (20 cm) open space on each side and 6 in. (15 cm) open space in the rear of the instrument for
ventilation.
2. is free from vibration of large equipment and/or excessive walk-through traf c.
3. provides adequate bench space for sample handling and optional accessories (printer), if applicable.
4. permits the instrument to be connected to a dedicated, grounded outlet. The STAR System 2/6 should be operated on a
stabilized, constant voltage AC power supply, and the voltage must be within ±10% of the speci ed level. (See Speci ca
tions in this manual.)
Note: Measure line voltage to ensure that it meets system speci cations.
CAUTION
Line voltage uctuations greater than 10% will affect instrument performance.
5. provides a temperature range of 60 °F (15 °C) to 104 °F (40 °C) and a humidity range of 10-85 percent relative humidity.
6. provides access to a fume hood or other means of fume disposal.
CAUTION
Do not place the STAR System inside a fume hood unless hydro uoric acid is used. Vent the instrument fumes
into a fume hood by means of the out-put tubing attached to the vacuum pump. Contact CEM Corporation for
information on the proper external air intake.
4
Unpacking System Components
1. Unpack the system components main instrument, vapor containment system (including vacuum pump, reagent
addition module and accessories.
2. Remove all protective materials. Retain all packing and protective materials.
3. Verify that all accessories listed below and illustrated in gure 1 are included.
System 2 System 6
Vessel (Pyrex glass) 2 6
Condenser 2 6
Shield 2 6
Vessel Rack 1 1
Power Cord 1 1
Fuse 2 2
Communication Cable 1 1
Operation Manual 1 1
Boiling Tube (Not Illustrated) 30 30
Fume Exhaust Tubing (1 /4 Te on®) 2 6
(Not Illustrated)
Reagent Waste Tubing (1 /4 Te on®) 2 6
(Not Illustrated)
Vapor Module Plug
STAR System Accessory Kit
In
novators in Microwave
Technolo
gy
Corporation
5
STAR System 6 Main Instrument
STAR System 6 Vapor Collection Module
STAR System 6 Reagent Addition Module STAR System Scrubber
6
Instrument Inspection
1. Inspect the instrument for cracks, dents or warping.
WARNING
If damage is noted, do not attempt instrument startup.
2. If the instrument has been damaged in shipping, contact the freight carrier to report damage and to le a damage report.
Contact the CEM Service Department or local subsidiary or distributor to report damage and to request service information.
CEM Corporation
Service Department
P.O. Box 200
3100 Smith Farm Road
Matthews, NC 28105-0200 USA
Within the continental United States
(800) 726-5551
Outside the United States
Telephone: (704) 821-7015
Fax: (704) 821-7894
Telex: 802118
CEM Ltd. CEM GmbH CEM S.r.l.
Unit 2 Middle Slade Carl-Friedrich-Gauss-Str. 9 Via DellArtigianato, 6/8
Buckingham Ind. Park 47475 Kamp-Lintfort 24055 Cologno al Serio (Bg)
Buckingham MK18 1WA Germany Italy
United Kingdom Tel: (49) 2842-96440 Tel: (39) 35-896224
Tel: (44) 1-280-822873 Fax: (49) 2842-964411 Fax: (39) 35-891661
Fax: (44) 1-280-822342
7
Instrument Description
Vapor Collection
Module
Vapor Collection
Module
Main
Instrument
Main
Instrument
Reagent Addition
Arm
Reagent Addition
Arm
Display &
Keyboard
Display &
Keyboard
Lighted
Window
for Cavity
Lighted
Window
for Cavity
Condenser
Condenser
Vessel
Vessel
STAR System 2 (Front View)
STAR System 6 (Front View)
8
STAR System 6 (Rear View)
STAR System 6 (Side Views)
On/Off
Switch
Computer
Port
Vapor Collection
Port
Printer
Port
Voltage
Selection
Switch
Power
Cord
Receptacle
9
Instrument
Vessel holds the sample during a digestion
Cavity positions the vessel and provides the microwave energy to perform the digestion
Condenser condenses vapors and directs reagents to ow down the sides of the vessel
Vessel Liner directs spillage into the spill tray
Shield prevents contact with reagents should an event occur during a digestion
Reagent Addition Arm routes vapors from vessel and directs reagent(s) to vessel
Vapor Containment System removes vapors and routes them to the fume hood during the digestion process (includes vapor
collection module and vapor scrubber)
Vapor Collection Module directs fumes from the vessel to the vapor scrubber
Vapor Scrubber contains solutions to neutralize vapors during the digestion process
Reagent Addition Module (optional) automatically adds reagents to the cavity in programmed quantities
Reagent Pump Adds one reagent to one cell
Vacuum Pump pulls vapors from vessel through the vapor collection module and directs them into the fume hood
Vessel-in-Position Sensor prevents operation if the vessel is not installed
Temperature Sensor monitors the temperature during the diges-tion and provides feedback control
10
STAR System Reagent Addition Module (Front View)
STAR System Reagent Addition Module (Rear View)
to Star
System
11
Keyboard
Select permits selection of the applicable cavity for setup, editing and/or operation and permits emergency reagent addition
when a cavity is paused during a method
Start/Pause begins the method currently displayed on the selected cavity screen or pauses the operation during any stage
of the method
Stop stops operation of method and returns to the cavity main screen
Edit permits editing of parameters for the method displayed on the selected cavity
Home returns the selected cavity to the main screen
Print permits printing of method data, method program and/or setup parameters
Setup permits editing of system parameters
Change incrementally increases or decreases current parameter displayed on selected cavity (upper case letters, lower case
letters, numbers and symbols) or scrolls through selections such as methods, reagents, etc.
Next advances to the next method parameter during editing or setup menus
Back returns to the previous screen during editing or setup menus
STAR System Keyboard
12
4. Facing the main instrument, place the reagent addition module on the left side and the scrubber module on the right side
of the main instrument.
5. Lift the arm from the receptacle in cell #1; pull it forward and position it over its cell.
6. Carefully pry each side of the cover of cell #1 to release it from the positioning pins on each side of the arm.
7. Lift the front of the cover and slide the cover away from the area.
8. Locate the tubing bundle mounted on the top of the reagent module for cavity #1.
Note: The number of tubes in the bundle is dependent upon the number of reagents being utilized.
9. Slide a tting on the end of the rst length of tubing with approximately 2 of tubing extending beyond the tting.
10. Slide a ferrule on the tubing with the tapered end of the ferrule facing the installed tting. Insert the ferrule into the
tting until it is snug.
11. Insert one length of tubing in the bundle into one of the four ports in the reagent head of arm #1, ensuring that the tubing
extends beyond the head into the chamber of the arm, but not beyond the tip which ts into the vessel.
Installation of Vapor Collection Module on Main Instrument
Component Installation
1. Position the main instrument on the selected installation site (bench area if not using HF or inside a fume hood if adding
HF manually.
2. Ensure that the vessel support ring is properly installed and seated. Using an index nger, position the liner in each cavity so
that the opening in the bottom of the liner is positioned above the opening in the RF stub ( gure 6, page 8). Note: If liners
are not installed, refer to Vessel Liner Replacement, page 75, for procedures for installing vessel liners.
3. Position the vapor collection/reagent addition module on top of the main instrument. Secure the vapor collection
module with the two bolts.
13
12. Tighten the tting nger tight.
13. Install each length of tubing in the bundle for cavity #1 as outlined in steps 10 through 13.
14. Install a plug into each opening of the reagent head that does not contain tubing for a reagent.
Installation of Vapor Collection Module on Main Instrument
15. Once all tubing and/or plugs are installed, position the cover over the arm. Place the 1/8 tubing into the smaller slot in the
back of the cover and the 1/4 tubing in the larger slot. Position the back of the cover over the locator pin on the back of
the arm, ensuring that the tubing is not crimped. Then push the front of the cover into place, ensuring that the locator pins
engage the holes in each side of the cover.
16. Lift the arm assembly and push it toward the back of the instrument and position the tip of the arm into the receptacle.
17. Repeat steps 10 through 17 for each cavity of the instrument.
18. Fill the reagent containers as required.
WARNING
Proper precautions must be taken to avoid contact with reagents or reagent vapors. Protective gear should be worn
as outlined in the users safety program for hazardous materials and the reagent manufacturers material safety
data sheet. Refer to these guidelines for proper handling of the reagent.
19. Place one of the plastic stopers provided in the accessory kit into each reagent container. Position the reagent tubing in the
appropriate reagent containers. Ensure that the tubing is placed into the correct
reagent container so that the proper reagent will be added to the sample as required.
WARNING
Do not use the reagent addition module for pumping HF.
WARNING
The tubing must be secured in the reagent container.
14
20. Connect the tubing extending from the scrubber module to the manifold installed on the vapor collection module.
21. Place a suitable waste container behind the main instrument. Place the tubing labeled waste into the container. Ensure that
the tubing extends suf ciently into the container to prevent it from pulling free, but not far enough to extend into the waste.
The waste level should always be below the tubing.
22. Install the safety shields. Place a vessel in each cell.
23. If using a printer, connect the printer cable into the printer port on the back of the main instrument.
Perform printer setup as outlined in the printer literature.
24. Plug the main instrument into a dedicated electrical outlet.
25. Ensure that the voltage selection switch is in the proper position to parallel electrical line voltage.
26. To position the vapor collection arm on the vessel, lift the arm and pull forward to position the reagent head over the vessel.
15
STAR System 6 Installed on Work Bench
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

CEM Star Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI