32
SAFETY WARNINGS
INSTALL IN A SECURE WORKING ENVIRONMENT
• Install the equipment in areas free from gas and inflammable substances (Acetylene, Propane etc.), which could cause explosions of fires.
SWITCH OFF MAIN ELECTRIC SOURCE
• Before inspecting the product, turn the main electric source off by removing the plug from the electric socket or by using the power swit-
ch. Otherwise, it could cause electric shock.
DO NOT TOUCH
• Do not touch moving parts while the main electric source is active, to avoid causing injury to hands.
GROUND PRODUCT WITH A GROUNDING CABLE
• Correctly ground the product with a grounding cable.
ONLY USE FOR SUPPLYING AIR
• Do not use the compressor to supply any type of gas, other than air, to avoid the risk of fires or explosions.
NEVER CONNECT TO RESPIRATORS
• Never connect respirators to compressed air outlet, to avoid serious injury or irreversible damage to the operator.
NEVER USE FOR SUPPLYING AIR TO MEDICAL EQUIPMENT
• Never connect to medical equipment directly. (Connect a protection system when using with medical equipment). Otherwise the health
or life of the operator could be put at risk.
INSTALL IN A SECURE WORKING ENVIRONMENT
• Never install the compressor where it could come into contact with atmospheric elements. The material used to manufacture the pro-
duct is not water resistant. If electrical parts come into contact with water, it could lead to a short circuit and cause fire.
DO NOT TOUCH
• Do not directly touch any part of the system whilst it is in operation, or immediately after, to avoid burns.
OBSERVE THE RECOMMENDED WORKING TEMPERATURE
• The recommended working temperature is between 0~40°C. Use at above or below the recommended temperature could cause mal-
function and damage the equipment.
IMPORTANT SPECIFICATIONS
HOW TO OPERATE
•
First of all, make sure that the electric power switch is switched off (OFF), then connect the electric cable to
to the electric socket.
• Switch the electric power switch on (ON) and make sure that the compressor works correctly.
• Allow it to run for 5 minutes, making sure that it does not create any anomalous noises or vibrations.
Connect the electric power cable plug directly to the electric socket. Use of an extension lead could
create a reduction in voltage, causing the engine to stall. You are advised to refrain, as far possi-
ble,
from using extension leads for the electrical connection.
USE
• Connect the air hose and airbrush to the compressor.
• Make sure that the power switch is switched off (OFF) and connect the electric power cable plug direct-
ly to the electric socket.
• Activate the electric power switch (ON) to operate the compressor.
PRESSURE SETTING
• Use the pressure regulator knob on the compressor to calibrate air pressure. Turn the regulator knob
clockwise to increase pressure and anti-clockwise to reduce pressure.
Make sure that the compressor, air hose and airbrush are securely connected. Accidental disconnection of the air hose whilst in
operation, could cause bodily injury.
Before switching the compressor on, make sure there isn’t any residual pressure inside the air hose. Residual pressure could
cause the engine to stall.
To avoid burns, do not touch the surfaces of the compressor (except the parts necessary to switch it on) whilst in operation.
If you detect any anomalous vibrations or unusual noises caused by product failure, switch the equipment off immediately and
do not switch it on again until the problem has been resolved.
• To disactivate the compressor, switch the power switch off (OFF) and pull the airbrush trigger to completely discharge residual air pres-
sure from the compressor.
Always discharge residual air pressure from the air hose completely, after use. Never direct the air discharge towards the human
body, to avoid inflammation of eyes or skin.
MAINTENANCE AND INSPECTION
• Carry out the following operations periodically to guarantee the correct working order of the equipment.
Before carrying out any maintenance procedures, always disconnect the compressor from the main electric source, by remov-
ing the electric cable plug from the socket, to avoid injury or electric shock.
Before carrying out any maintenance procedures, always discharge residual air pressure from the compressor completely, so
that parts under pressure are not forcefully released during disassembly, causing injury.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
OPERATION PERIODICAL MAINTENANCE REFER TO
Daily Every 100 hours
Every 6 months
Complete inspection X How to operate page 3
Inspect air pressure X How to operate page 3
regulator knob
Check for unusual noises
or vibrations X Problems and Remedies page 4
Check mini filter
anti-condenser X Clean mini filter
Air
outlet
Pressure
regulator
knob
Pressure regulator knob
Power
Switch
Power
switch
-+
Model IS-50 (Silver Jet)
Motor: W 110-140
Max. pressure: bar 1,3
Air flow: L/min 9
Weight: kg 2,9
Dimensions : mm 150 x 155 x 180
Spiral hose: 4 m (code HPA-CH41)
Moisture grip filter: VIMFA450