1-3
INSTALLATION AND OPERATING INSTRUCTIONS
TANKLESS WATER HEATER 199
1.2 CODE REQUIREMENTS
TThe Tankless Water Heaterhe Tankless Water Heater is is certiedunderCSA4.3/ANSIZ21.10.3.
Theinstallationmustconformtotherequirementsoftheauthorityhaving
jurisdictionor,intheabsenceofsuchrequirements,totheNational Fuel
Gas Code, ANSI Z223.1/NFPA 54, (latest edition) in the US or Natural Gas
and Propane Installation Code, CSA B149.1 (latest edition) in Canada. The
installation must also conform to the Canadian Electrical Code Part 1 in Canada
or the National Electrical Code ANSI/NFPA 70 (latest edition) in the US.
1.3 LOCATION
TheThe unit is designed and approved for indoor installation. Its venting options
provideexibilityoflocation;forexample,placementinanalcove,basement,
utility room or closet. The unit is approved for installation in a closet (see Table 2
for clearances to combustibles).
Conditions for safe installations
Ensure that the surrounding conditions are between 32°F [0°C] and 122°F [50°C]
and less than 90% relative humidity.
Install the unit in areas where the combustion air source is free of
contamination.
Exposure to corrosive chemical fumes such as chlorinated and/or
uorinated hydrocarbons can reduce the life of a water heater. Cleaners,
bleaches,airfresheners,refrigerants,aerosolpropellants,dry-cleaninguids,
de-greasers and paint-removers contain vapors that can form corrosive acid
compoundswhenburnedinagasame.Alsoavoidairbornechloridessuchas
those released with the use of laundry detergents.
This unit must not be installed in an area where water leakage will result in
damagetotheareasadjacentorbelowtheunit.Whensuchareascannotbe
avoided,asuitabledrainpanwithadequatedrainmustbeinstalledunderthe
unit.
Water heater fastening
Approximate weight for the empty water heater
is
68 lbs / 31 kg. For support
fasteners, use at least two of the four supplied ¼" x 1¾" long lag screws. Installers
must supply 1/4" bolts if metal mounting systems are used. Attach the wall
mounting bracket to a structurally sound wall that is capable of supporting the
combined weight of the unit
and piping components which can exceed 150 lbs.
(68kg).
Water heater clearance
Otherfactorsaectingpotentialmountingsites:
• Ensureminimumclearancerequirementsforcombustiblematerials(see
Table 2)aresatised.
• For ease of access, we recommend a minimum 24" clearance at the front and
24" above. Check local codes for additional access and service clearance
requirements.
•
At a new construction site, or during renovations, protect the unit from
drywall dust or other construction related contaminants. Combustion air
must be drawn from a CLEAN source (e.g. outdoors) and the unit must be
isolated from interior dust sources.
WARNING
- Keep the unit area free
and clear of combustible
materials, gasoline, and other
ammable vapors and liquids.
- C
ombustion air must not be
drawn from areas containing
corrosive air from swimming
pools or spas, including air
directly next to outdoor pools
and spas.
- T
he unit must not be
exposed to water leaks from
piping or components located
overhead. This includes
condensation dropping from
un-insulated cold water lines
overhead.
-
Ensure the gas ignition
system components are
protected from water (dripping,
spraying, rain, etc.) during
appliance operation and when
servicing (pump replacement,
condensate trap servicing,
control replacement, etc.)
-California Proposition 65
This product contains
chemicals known to the
state of California to cause
cancer, birth defects, or other
reproductive harm.