IMPORTANT
Do not obstruct the front of the heater
for at least 48 in. (1200 mm).
INSTALLATION
INSTRUCTIONS
CAUTION: Usesupplywiressuitablefor90°C(194°F).
- For bathroom use, the heater must be installed so that
switchesandothercontrolscannotbetouchedbyanyone
inthebathorshower.
SURFACE WALL MOUNTING;
1- Locateapproximatelythepowersupplyleadsbehindthe
planned location of the heater. Recommended clearance
below heater base to oor is 4 in. (102 mm) minimum.
Allow4in.(102mm)minimumclearancebetweensides
ofheaterandanyadjacentwalls.Theleadsshallbeatthe
rightofthewallbracket.
2- Leanthebottomofthewallbracketontheoorandmark
with a pencil the height desired (of the heater bottom)
usingthewholeswithincheswrittenontheside.
3- Securewallbracketwiththe4screwssupplied.Thebottom
ofthekeyholesshallbeinlinewiththepreviousmarks.
Trianglemarkonhorizontalbaristhecenteroftheheater.
Beforeinstallingwallsupport,aligncenterofheaterwith
supportcentermarkandmakesuretheheatersidesareat
least4in.(102mm)fromanyadjacentwalls.
4- Untighten wire holder (for Loomex cable) and make
electrical connections by having the heater the nearest
possibletotheelectricalwire.ForBXcable,removeoneof
thetwoknock-outs,installaconnector(notfurnished)and
have6to8in.(15to20cm)offreewireandgetthemout
oftheholeofthewireholderinordertomakeconnections
fromoutside.Donotforgettoconnectthegreenwireto
groundwireinordertohaveasafegroundedheater.
5- Once connections completed, place bottom T slots in the
base part of support, and clip the upper side of the body in
the upper U shape part of the support.
6- Donotlettheexcessofthesupplywirecomeincontact
withthebackoftheheater,aswellasanyotherobject.
7- Putthemainpoweron.
CAUTION:
Hightemperature,riskofre,keepelectricalcords,drapery,
furnishings, and other combustibles at least 36 in. (915 mm)
fromthefrontoftheheaterandawayfromthesides.Toreduce
theriskofre,donotstoreorusegasolineorotherammable
vapors and liquids in the vicinity of the heater.
1 800 463-7043 • www.globalcommander.ca
INSTALLATION INSTRUCTIONS
Convector “CEG” Series
Read carefully these instructions before installation, operation of the
heater. Failure to adhere to the instructions could result in re, electric
shock, serious personal injury, and death or property damage. Review
frequently for continuing safe operation and instruction of future users,
if necessary.
IMPORTANT
INSTRUCTIONS
1- Read all instructions before installing or using this heater.
2- Thisheaterishotwheninuse.To avoid burns, do not let bare skin
touchhotsurfaces.Keepcombustiblematerials,likefurniture,pillows,
bedding, papers, clothes, and curtains at least 36 in. (915 mm) from the
frontoftheheaterandawayfromthesides.
3- Extreme caution is necessary when any heater is used by or near
children or invalids and whenever the heater is left operating and
unattended.
4- Donotoperateanyheaterafteritmalfunctions.Disconnectpower
at service panel and have heater inspected by a reputable electrician
before reusing.
5- Do not use outdoors.
6- Todisconnectheater,turnopowertoheatercircuitatmaindisconnect
panel.
7- Donotinsertorallowforeignobjectstoenteranyexhaustopeningas
thismaycauseanelectric shockorre,ordamagetheheater.
8- Donotblockairintakesorexhaustinanywaywhatsoever.
9- Thisheaterhashotandarcingorsparkingpartsinside.Donotuseitin
areaswheregasoline,paint,orammableliquidsareusedorstored.
10- Use this heater only as described in this manual. Any other use not
recommendedbythemanufacturermaycausere,electricshock,or
injury.
11- AMERICAN VERSION ONLY: Some models (up to 240V) include
avisualalarmtowarnthatpartsoftheheateraregettingexcessively
hot.Ifthelightturnson,immediatelyturntheheateroandinspect
for any objects on or adjacent to the heater that may have blocked
the airow or otherwise caused high temperatures to have occured.
If no obstruction is visible, the heater must be checked by a quali-
ed person. DO NOT OPERATE THE HEATER WHEN THE
ALARM LIGHT IS ON.
12- The thermostat should not be considered an infallible device in cases
where maintaining a temperature is considered critical. Examples:
Hazardous material storage, computer server room, etc. In these
particular cases, it is imperative to add a monitoring system to avoid
the consequences of a thermostat failure.
INS420-201402-03
MAINTENANCE
INSTRUCTIONS
1- Once a year, remove the front panel and use a vacuum cleaner
to remove the dust accumulation inside the heater and through
openings of the front panel.
2- Cleaningshouldbedonewhiletheheaterisdisconnectedfrom
the main service panel. Wait until the housing and heating
element cool before performing maintenance.
3- Replace the front panel before energizing.
4- Any other servicing should be performed by a qualified
technician.
WARRANTY
Pleaserefertothespecicationsheetatwww.globalcommander.ca.
WARNING
Whenusingelectricalappliances,basicprecautionsshouldalwaysbetaken
toreducetheriskofre,electricalshockandinjury,includingthefollowing.
OPERATING
INSTRUCTIONS
- The heater must be properly installed before it is used.
- Turnthepoweronatthecircuitbreakerpanel.
- Electronic thermostat: Set the thermostat temperature at the
wantedroomtemperature
CONTROL:
Modelwithbuilt-inelectronicthermostat:
Theelectronicthermostatshallkeeptheroomtemperatureinarange
of±1°C(±2°F)unlesstheroomisnotwellinsulatedortheheater
istooornotenoughpowerfulfortheroom.
Modelwithoutcontrol:
Maintain room temperature by a line-voltage wall thermostat
approved for residential heating. Even if it is not mandatory, an
electronic thermostat gives better performance than a conventional
thermostat.
4 5
A
4’’
(102 mm)
minimum
4’’ (102 mm)
minimum
4’’
(102 mm)
minimum
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
TOP
HAUT
TOP
HAUT
HAUT - TOP
CENTRE
DETAIL A
Mark
the height
desired
Center mark
Center
3
1 2
THERMOSTAT
L1
L1 L2
L2
Load 1Load 2
Wiring Diagram:
Model with built-in
electronic thermostat
American version only
up to 240V
L2/N
L1
Wiring Diagram:
Model without control
American version only
up to 240V
SAVE THESE INSTRUCTIONS
OPTIONS:
All heating equipment and options must be installed in
accordancewithlocalandnationalcodes.
Built-in relay:
-Refertothediagramincludedwiththerelayoptionfor
connections.
-Refertoinstructionssuppliedwiththeoptionformounting.